MIB Viewer

SCC-RAID7-MIB

41 objects
No module-level DESCRIPTION found.
OIDNameAccessStatusDescription
1.3.6.1.4.1.1386.2.1.1Noderaid7DriveUpThis trap is sent whenever the state for a drive changes to data or parity from any other value. An equivalent poll would be to poll raid7NumberDrives and raid…
1.3.6.1.4.1.1386.2.1.1Noderaid7Sys
1.3.6.1.4.1.1386.2.1.1.1Scalarraid7SysVersionread-onlymandatoryDescribes the revision level of the running RAID7 Operating System; this is not really an IP address - but the revision is expressed as 4 decimal numbers so th…
1.3.6.1.4.1.1386.2.1.2Noderaid7DriveDownThis trap is sent whenever the state for a drive changes from data or parity to any other value. An equivalent poll would be to poll raid7NumberDrives and raid…
1.3.6.1.4.1.1386.2.1.2Noderaid7Memory
1.3.6.1.4.1.1386.2.1.2.1Scalarraid7TotalMemread-onlymandatoryThe number of kilobytes of memory present
1.3.6.1.4.1.1386.2.1.2.2Scalarraid7GoodMemread-onlymandatoryThe number of kilobytes of memory judged good by self-test
1.3.6.1.4.1.1386.2.1.2.3Scalarraid7MemAvailread-onlymandatoryThe number of kilobytes of memory currently in use.
1.3.6.1.4.1.1386.2.1.2.4Scalarraid7CacheHitPercentread-onlymandatoryThe system-wide percentage of operations satisfied from the RAID7 system cache. This does not include any operations satisfied from cache in channel adapters, …
1.3.6.1.4.1.1386.2.1.2.5Tableraid7BlockTablenot-accessiblemandatoryThis table shows how the host transfer block sizes have been distributed - it can be used to tune system performance (see the RAID 7 User Guide).
1.3.6.1.4.1.1386.2.1.2.5.1Rowraid7BlockEntrynot-accessiblemandatoryInformation specific to blocks of a given size.
1.3.6.1.4.1.1386.2.1.2.5.1.1Columnraid7BlockSizeread-onlymandatorySize of the blocks.
1.3.6.1.4.1.1386.2.1.2.5.1.2Columnraid7NumBlocksread-onlymandatoryNumber of blocks of this size.
1.3.6.1.4.1.1386.2.1.3Noderaid7EnvironmentFailureThis trap is sent when the value of raid7EnvironmentStatus changes to failure.
1.3.6.1.4.1.1386.2.1.3Noderaid7Host
1.3.6.1.4.1.1386.2.1.3.1Scalarraid7NumHostChannelsread-onlymandatoryThe number of functional Host I/O Channels.
1.3.6.1.4.1.1386.2.1.3.2Tableraid7ChannelTablenot-accessiblemandatoryA table describing each of the Host I/O Channels
1.3.6.1.4.1.1386.2.1.3.2.1Rowraid7ChannelEntrynot-accessiblemandatoryInformation specific to a given Host I/O Channel
1.3.6.1.4.1.1386.2.1.3.2.1.1Columnraid7ChannelNumberread-onlymandatoryThe number of this Host I/O Channel
1.3.6.1.4.1.1386.2.1.3.2.1.2Columnraid7ChannelTransferRateread-onlymandatoryA measure of the data transfer speed on this channel during recent transfers (does not include the idle time on the channel between transfers in the calculatio…
1.3.6.1.4.1.1386.2.1.3.2.1.3Columnraid7ChannelTransactionRateread-onlymandatoryA measure of the number I/O operations per second on this channel.
1.3.6.1.4.1.1386.2.1.3.2.1.4Columnraid7ChannelErrorMsgsread-onlymandatoryThe number of error messages on this channel; see the RAID7 console and the User Guide.
1.3.6.1.4.1.1386.2.1.3.2.1.5Columnraid7ChannelLastKeyread-onlymandatoryThe most recently reported SCSI Key value
1.3.6.1.4.1.1386.2.1.3.2.1.6Columnraid7ChannelLastSenseread-onlymandatoryThe last SCSI Sense reported.
1.3.6.1.4.1.1386.2.1.4Noderaid7Drive
1.3.6.1.4.1.1386.2.1.4.1Scalarraid7NumDrivesread-onlymandatoryThe number of drives installed in the RAID7 system
1.3.6.1.4.1.1386.2.1.4.2Scalarraid7NumDataDrivesread-onlymandatoryThe number of drives being used as data drives; this may not be equal to the total of the drives in the following objects.
1.3.6.1.4.1.1386.2.1.4.3Scalarraid7NumParityDrivesread-onlymandatoryThe number of drives being used to store parity information.
1.3.6.1.4.1.1386.2.1.4.4Scalarraid7NumStandbyDrivesread-onlymandatoryThe number of drives available for reconstructing data from a failed drive.
1.3.6.1.4.1.1386.2.1.4.5Scalarraid7NumFailedDrivesread-onlymandatoryThe number of drives whos raid7DriveState is either reconstructing or failed.
1.3.6.1.4.1.1386.2.1.4.6Tableraid7DriveTablenot-accessiblemandatoryA list of drive entries, one for each physical drive; this may be a sparse table.
1.3.6.1.4.1.1386.2.1.4.6.1Rowraid7DriveEntrynot-accessiblemandatoryInformation specific to a single drive.
1.3.6.1.4.1.1386.2.1.4.6.1.1Columnraid7DriveNumberread-onlymandatoryDrive number of this drive.
1.3.6.1.4.1.1386.2.1.4.6.1.2Columnraid7DriveStateread-onlymandatoryState of this drive.
1.3.6.1.4.1.1386.2.1.4.6.1.3Columnraid7DriveActivityread-onlymandatoryThis is letter indicating the most recent operation reported for the drive. See the RAID7 User Guide for values and thier meanings.
1.3.6.1.4.1.1386.2.1.4.6.1.4Columnraid7DriveWritesread-onlymandatoryNumber of write operations to this drive.
1.3.6.1.4.1.1386.2.1.4.6.1.5Columnraid7DriveReadsread-onlymandatoryNumber of read operations to this drive; does not include operations satisfied from RAID7 system or channel cache, but does include those satisfied from any ca…
1.3.6.1.4.1.1386.2.1.4.6.1.6Columnraid7DriveTimeOutsread-onlymandatoryThe number of SCSI operations timed out on the drive.
1.3.6.1.4.1.1386.2.1.4.6.1.7Columnraid7DriveErrorsread-onlymandatoryNumber of errors reported by the drive
1.3.6.1.4.1.1386.2.1.5Noderaid7Env
1.3.6.1.4.1.1386.2.1.5.1Scalarraid7EnvironmentStatusread-onlymandatoryThe 'failure' indicates that one or more power supplies or fans in the unit have failed.