MIB Viewer

SCTE-HMS-HE-RF-SWITCH-MIB

34 objects
Change Log: 1. Added Unsigned32 and Integer32 to IMPORTS 2. Removed TEXTUAL-CONVENTION from IMPORTS 3. Corrected 4 digit date code defined in RFC2578 4. heRFSwitchWaitToRestoreTime is changed to Integer32 instead of INTEGER 5. Corrected object type definition in HeRFSwitchInputEntry sequence 6. Added double quote at the end of heRFSwitchInputExternalControl description 7. Changed Rf to RF 8. Changed OID number of heRFSwitchMIBCompliances to 1 instead of 2 9. Changed the text description of SNMPv2 to SNMP for heRFSwitchBasicCompliance MODULE-COMPLIANCE
OIDNameAccessStatusDescription
1.3.6.1.4.1.5591.1.11.4.2.1IdentityheRFSwitchMIBChange Log: 1. Added Unsigned32 and Integer32 to IMPORTS 2. Removed TEXTUAL-CONVENTION from IMPORTS 3. Corrected 4 digit date code defined in RFC2578 4. heRFSw…
1.3.6.1.4.1.5591.1.11.4.2.1.1NodeheRFSwitchMIBObjects
1.3.6.1.4.1.5591.1.11.4.2.1.1.1TableheRFSwitchUnitTablenot-accessiblecurrentA table containing information about RF Switch used in an indoor environment.
1.3.6.1.4.1.5591.1.11.4.2.1.1.1.1RowheRFSwitchUnitEntrynot-accessiblecurrentList of information about each RF switch.
1.3.6.1.4.1.5591.1.11.4.2.1.1.1.1.1ColumnheRFSwitchModeread-writecurrentThis controls and/or reports the switching mode. If automatic(1), the RF switch will evaluate the RF input status and make the decision to affect the switch st…
1.3.6.1.4.1.5591.1.11.4.2.1.1.1.1.2ColumnheRFSwitchControlread-writecurrentSets the intended state of the RF Switch. The effect of this control will depend on the value of heRFSwitchMode. If heRFSwitchMode is set to automatic, the val…
1.3.6.1.4.1.5591.1.11.4.2.1.1.1.1.3ColumnheRFSwitchRevertEnableread-writecurrentThis controls the use of revert switching. If set to on, the switch will attempt to go back to the preferred settings indicated by heRFSwitchControl if heRFSwi…
1.3.6.1.4.1.5591.1.11.4.2.1.1.1.1.4ColumnheRFSwitchStateread-onlycurrentReports the state of the RF Switch. Not all enumerations must be supported. For example, an A-B RF switch may support only the pathA and pathB enumerations whi…
1.3.6.1.4.1.5591.1.11.4.2.1.1.1.1.5ColumnheRFSwitchFailoverStatusread-onlycurrentThe integral status of both inputs. A value is fault(2), if current switch state heRFSwitchState is different than the preferred setting heRFSwitchControl, oth…
1.3.6.1.4.1.5591.1.11.4.2.1.1.1.1.6ColumnheRFSwitchBothInputStatusread-onlycurrentThe integral status of both inputs. A value is fault(2), if both input levels are below the nominal value; otherwise, it is normal(1). This object must provide…
1.3.6.1.4.1.5591.1.11.4.2.1.1.1.1.7ColumnheRFSwitchHysteresisread-writecurrentControls switch input hysteresis amount. The amount of hysteresis used and the ability to change it is to be determined by the vendor.
1.3.6.1.4.1.5591.1.11.4.2.1.1.1.1.8ColumnheRFSwitchWaitToRestoreTimeread-writecurrentControls hysteresis time in sec. If in automatic switching mode and revert mode is enabled, a switch back to the original side will be delayed for the time spe…
1.3.6.1.4.1.5591.1.11.4.2.1.1.1.1.9ColumnheRFSwitchSensorModeread-writecurrentControls what source will be used for determining input status: A value of internal(1) causes the internal RF detection circuitry to be used. A value of extern…
1.3.6.1.4.1.5591.1.11.4.2.1.1.2TableheRFSwitchInputTablenot-accessiblecurrentA table containing information about each RF Switch input used in an indoor environment.
1.3.6.1.4.1.5591.1.11.4.2.1.1.2.1RowheRFSwitchInputEntrynot-accessiblecurrentList of information about each RF switch input.
1.3.6.1.4.1.5591.1.11.4.2.1.1.2.1.1ColumnheRFSwitchInputIndexnot-accessiblecurrentIndex number corresponding to the RF Input.
1.3.6.1.4.1.5591.1.11.4.2.1.1.2.1.2ColumnheRFSwitchInputRFLevelread-onlycurrentThe measured RF input power for the RF switch.
1.3.6.1.4.1.5591.1.11.4.2.1.1.2.1.3ColumnheRFSwitchSetInputPowerThresholdread-writecurrentInput power switchover point for this input.
1.3.6.1.4.1.5591.1.11.4.2.1.1.2.1.4ColumnheRFSwitchInputStatusread-onlycurrentThe integral status of the input. A value is fault(2), if the input levels are not in the nominal range; otherwise, it is normal(1). This object must provide f…
1.3.6.1.4.1.5591.1.11.4.2.1.1.2.1.5ColumnheRFSwitchInputDescriptionread-onlycurrentA description of the switch input port. The description text is to be determined by the equipment manufacturer. For example, Input A or Side B.
1.3.6.1.4.1.5591.1.11.4.2.1.1.2.1.6ColumnheRFSwitchInputExternalControlread-onlycurrentThis is an external control signal that indicates the status of the associated input. A value is fault(2), if the external control signal level is not in the n…
1.3.6.1.4.1.5591.1.11.4.2.1.1.3TableheRFSwitchOutputTablenot-accessiblecurrentA table containing information about each RF Switch output used in an indoor environment.
1.3.6.1.4.1.5591.1.11.4.2.1.1.3.1RowheRFSwitchOutputEntrynot-accessiblecurrentList of information about each RF switch output.
1.3.6.1.4.1.5591.1.11.4.2.1.1.3.1.1ColumnheRFSwitchOutputIndexnot-accessiblecurrentIndex number corresponding to the RF Output.
1.3.6.1.4.1.5591.1.11.4.2.1.1.3.1.2ColumnheRFSwitchOutputDescriptionread-onlycurrentA description of the switch output port. The description text is to be determined by the equipment manufacturer. For example, Output A or Seconday Output.
1.3.6.1.4.1.5591.1.11.4.2.1.2NodeheRFSwitchMIBConformance
1.3.6.1.4.1.5591.1.11.4.2.1.2.1NodeheRFSwitchMIBCompliances
1.3.6.1.4.1.5591.1.11.4.2.1.2.1.1ComplianceheRFSwitchBasicCompliancecurrentThe compliance statement for SNMP HMS Headend RF Switch entities which implement the SNMP heRFSwitchMIB.
1.3.6.1.4.1.5591.1.11.4.2.1.2.2NodeheRFSwitchMIBGroups
1.3.6.1.4.1.5591.1.11.4.2.1.2.2.1GroupheRFSwitchUnitMandatoryGroupcurrentThe main group defines heRFSwitchUnitTable objects which are mandatory to all indoor RF switch modules.
1.3.6.1.4.1.5591.1.11.4.2.1.2.2.2GroupheRFSwitchInputMandatoryGroupcurrentThe main group defines heRFSwitchInputTable objects which are mandatory to all indoor RF switch modules.
1.3.6.1.4.1.5591.1.11.4.2.1.2.2.3GroupheRFSwitchOutputMandatoryGroupcurrentThe main group defines heRFSwitchOutputTable objects which are mandatory to all indoor RF switch modules.
1.3.6.1.4.1.5591.1.11.4.2.1.2.2.4GroupheRFSwitchUnitGroupcurrentThe collection of heRFSwitchUnitTable objects which are used to represent the indoor RF switch module.
1.3.6.1.4.1.5591.1.11.4.2.1.2.2.5GroupheRFSwitchInputGroupcurrentThe collection of heRFSwitchInputTable objects which are used to represent the indoor RF switch module.