SERVERVIEW-DUPLEXDATAMANAGER-MIB
120 objects
No module-level DESCRIPTION found.
Imported Objects
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.231 | Nodesni | |||
| 1.3.6.1.4.1.231.2 | NodesniProductMibs | |||
| 1.3.6.1.4.1.231.2.10 | NodesniExtensions | |||
| 1.3.6.1.4.1.231.2.10.2 | NodesniServerMgmt | |||
| 1.3.6.1.4.1.231.2.10.2.2 | NodesniCommon | |||
| 1.3.6.1.4.1.231.2.10.2.2.9 | NodefscDuplexDataManager | |||
| 1.3.6.1.4.1.231.2.10.2.2.9.1 | NodefscDdmAgentInfo | |||
| 1.3.6.1.4.1.231.2.10.2.2.9.1.1 | ScalarfscDdmAgentId | read-only | mandatory | DuplexDataManager SNMP agent ID. |
| 1.3.6.1.4.1.231.2.10.2.2.9.1.2 | ScalarfscDdmAgentCompany | read-only | mandatory | DuplexDataManager SNMP agent company. |
| 1.3.6.1.4.1.231.2.10.2.2.9.1.3 | ScalarfscDdmAgentVersion | read-only | mandatory | DuplexDataManager SNMP agent version. |
| 1.3.6.1.4.1.231.2.10.2.2.9.1.4 | ScalarfscDdmAgentBuild | read-only | mandatory | DuplexDataManager SNMP agent build date and time. |
| 1.3.6.1.4.1.231.2.10.2.2.9.2 | NodefscDdmStatus | |||
| 1.3.6.1.4.1.231.2.10.2.2.9.2.1 | ScalarfscDdmLastDate | read-only | mandatory | Date of last recent reconfiguration in time_t (seconds since 1/1/1970 00:00:00). |
| 1.3.6.1.4.1.231.2.10.2.2.9.2.2 | ScalarfscDdmCurrentStatus | read-only | mandatory | Overall status of the driver, agent and the underlying objects. Possible values are: OK everything is fine DEGRADED at least one MultiPath or DuplexWrite group… |
| 1.3.6.1.4.1.231.2.10.2.2.9.2.3 | ScalarfscDdmInstallationType | read-only | mandatory | Type of installed DuplexDataManager edition. Possible values are: DDMWIN PRIMERGY DuplexDataManager(R) (Windows) DDEWIN PRIMERGY easyMirror(TM) (Windows) MPWIN… |
| 1.3.6.1.4.1.231.2.10.2.2.9.3 | NodefscDdmDwContainer | |||
| 1.3.6.1.4.1.231.2.10.2.2.9.3.1 | TablefscDdmDwPieceTable | not-accessible | mandatory | Table of all pieces DuplexWrite has detected. |
| 1.3.6.1.4.1.231.2.10.2.2.9.3.1.1 | RowfscDdmDwPiece | not-accessible | mandatory | Entry in table of DuplexWrite pieces. |
| 1.3.6.1.4.1.231.2.10.2.2.9.3.1.1.1 | ColumnfscDdmDwIndex | read-only | mandatory | Unique value for each DuplexWrite piece, starts at 0 and remains unchanged from one re-initialization of the agent to the next. Only used as index. |
| 1.3.6.1.4.1.231.2.10.2.2.9.3.1.1.2 | ColumnfscDdmDwDwPort | read-only | mandatory | Virtual SCSI port number of the DuplexWrite group. |
| 1.3.6.1.4.1.231.2.10.2.2.9.3.1.1.3 | ColumnfscDdmDwDwPath | read-only | mandatory | Virtual SCSI path number of the DuplexWrite group. |
| 1.3.6.1.4.1.231.2.10.2.2.9.3.1.1.4 | ColumnfscDdmDwDwTarget | read-only | mandatory | Virtual SCSI target ID of the DuplexWrite group. |
| 1.3.6.1.4.1.231.2.10.2.2.9.3.1.1.5 | ColumnfscDdmDwDwLun | read-only | mandatory | Virtual SCSI LUN of the DuplexWrite group |
| 1.3.6.1.4.1.231.2.10.2.2.9.3.1.1.6 | ColumnfscDdmDwDwName | read-only | mandatory | Name of the DuplexWrite group. |
| 1.3.6.1.4.1.231.2.10.2.2.9.3.1.1.7 | ColumnfscDdmDwDwGroupNumber | read-only | mandatory | Internal group number of the DuplexWrite group. |
| 1.3.6.1.4.1.231.2.10.2.2.9.3.1.1.8 | ColumnfscDdmDwDwPieceNumber | read-only | mandatory | Internal piece number in the DuplexWrite group. |
| 1.3.6.1.4.1.231.2.10.2.2.9.3.1.1.9 | ColumnfscDdmDwDwSize | read-only | mandatory | Size of the DuplexWrite group in MegaBytes. |
| 1.3.6.1.4.1.231.2.10.2.2.9.3.1.1.10 | ColumnfscDdmDwDwRoot | read-only | mandatory | RootDisk flag of the DuplexWrite group. The RootDisk flag indicates special handling for boot/system disks. Possible values are: ON RootDisk flag is turned on … |
| 1.3.6.1.4.1.231.2.10.2.2.9.3.1.1.11 | ColumnfscDdmDwDwRecoverMode | read-only | mandatory | Recover mode of the DuplexWrite groups. Possible values are: COPY during Recover all blocks are copied from one disk to another VERIFY during Recover blocks ar… |
| 1.3.6.1.4.1.231.2.10.2.2.9.3.1.1.12 | ColumnfscDdmDwDwStatus | read-only | mandatory | Status of the DuplexWrite piece. Possible values are: ONLINE piece is working properly PREFERRED piece is working properly, used for read operations ERROR erro… |
| 1.3.6.1.4.1.231.2.10.2.2.9.3.1.1.13 | ColumnfscDdmDwDwReason | read-only | mandatory | Reason why a status was set for the DuplexWrite piece. Possible values are: READFAILED read error WRITEFAILED write error RESERVATIONCONFLICT piece disabled be… |
| 1.3.6.1.4.1.231.2.10.2.2.9.3.1.1.14 | ColumnfscDdmDwDwActive | read-only | mandatory | Active DuplexWrite piece for Snapshot. Possible values are: ON piece is an active piece for Snapshot OFF piece is not an active piece for Snapshot UNKNOWN none… |
| 1.3.6.1.4.1.231.2.10.2.2.9.3.1.1.15 | ColumnfscDdmDwDwRecoverProgress | read-only | mandatory | Percentage of the Recover progress of the DuplexWrite piece. If no Recover is running the value is 0. |
| 1.3.6.1.4.1.231.2.10.2.2.9.3.1.1.16 | ColumnfscDdmDwDwHidden | read-only | mandatory | Hidden flag for DuplexWrite piece. Possible values are: ON piece is hidden from the operating system (not claimable) OFF piece is not hidden UNKNOWN none of th… |
| 1.3.6.1.4.1.231.2.10.2.2.9.3.1.1.17 | ColumnfscDdmDwDwRecent | read-only | mandatory | Recent flag for DuplexWrite piece. When no piece is Online the Recent flag indicates which piece was Online more recently. Possible values are: ON piece is the… |
| 1.3.6.1.4.1.231.2.10.2.2.9.3.1.1.18 | ColumnfscDdmDwDwForced | read-only | mandatory | Forced flag for DuplexWrite piece. This flag indicates that the driver forced this piece Online during boot although it was not shutdown in status Online. Poss… |
| 1.3.6.1.4.1.231.2.10.2.2.9.3.1.1.19 | ColumnfscDdmDwDwPieceCount | read-only | mandatory | Number of configured pieces in the DuplexWrite group. |
| 1.3.6.1.4.1.231.2.10.2.2.9.3.1.1.20 | ColumnfscDdmDwDwPieceFound | read-only | mandatory | Number of detected pieces in the DuplexWrite group |
| 1.3.6.1.4.1.231.2.10.2.2.9.3.1.1.21 | ColumnfscDdmDwDwBalance | read-only | mandatory | Dynamic Diskload Balancing state of the DuplexWrite group. Possible values are: ON Dynamic Diskload Balancing is turned on OFF Dynamic Diskload Balancing is tu… |
| 1.3.6.1.4.1.231.2.10.2.2.9.3.1.1.22 | ColumnfscDdmDwMpGroupNumber | read-only | mandatory | Internal MultiPath group number of the DuplexWrite piece starting with 0. |
| 1.3.6.1.4.1.231.2.10.2.2.9.3.1.1.23 | ColumnfscDdmDwScPort | read-only | mandatory | Real SCSI port number of the DuplexWrite piece. |
| 1.3.6.1.4.1.231.2.10.2.2.9.3.1.1.24 | ColumnfscDdmDwScPath | read-only | mandatory | Real SCSI path number of the DuplexWrite piece. |
| 1.3.6.1.4.1.231.2.10.2.2.9.3.1.1.25 | ColumnfscDdmDwScTarget | read-only | mandatory | Real SCSI target ID of the DuplexWrite piece. |
| 1.3.6.1.4.1.231.2.10.2.2.9.3.1.1.26 | ColumnfscDdmDwScLun | read-only | mandatory | Real SCSI LUN of the DuplexWrite piece. |
| 1.3.6.1.4.1.231.2.10.2.2.9.3.1.1.27 | ColumnfscDdmDwScDiskNumber | read-only | mandatory | Operating system assigned disk number of the DuplexWrite piece. |
| 1.3.6.1.4.1.231.2.10.2.2.9.3.1.1.28 | ColumnfscDdmDwScSize | read-only | mandatory | Capacity of the DuplexWrite piece in MegaBytes. |
| 1.3.6.1.4.1.231.2.10.2.2.9.3.1.1.29 | ColumnfscDdmDwScSignature | read-only | mandatory | Operating system assigned unique key (signature) of the DuplexWrite piece. If no signature is available the value is -1. |
| 1.3.6.1.4.1.231.2.10.2.2.9.3.1.1.30 | ColumnfscDdmDwScType | read-only | mandatory | The SCSI type of the DuplexWrite piece. Possible values are: DISK direct access device TAPE tape device PRINTER printer device PROCESSOR processor device WORM … |
| 1.3.6.1.4.1.231.2.10.2.2.9.3.1.1.31 | ColumnfscDdmDwScInquiry | read-only | mandatory | SCSI inquiry string (vendor and product id) of the DuplexWrite piece. |
| 1.3.6.1.4.1.231.2.10.2.2.9.3.1.1.32 | ColumnfscDdmDwScResource | read-only | mandatory | Cluster resource name of the DuplexWrite piece. Empty, if the piece is not a cluster resource. |
| 1.3.6.1.4.1.231.2.10.2.2.9.3.1.1.33 | ColumnfscDdmDwScNode | read-only | mandatory | Cluster node name that owns the DuplexWrite piece. Empty, if the piece is not a cluster resource. |
| 1.3.6.1.4.1.231.2.10.2.2.9.3.1.1.34 | ColumnfscDdmDwScPciBus | read-only | mandatory | PCI location of the controller (bus number). -1 if the location cannot be detected. |
| 1.3.6.1.4.1.231.2.10.2.2.9.3.1.1.35 | ColumnfscDdmDwScPciDevice | read-only | mandatory | PCI location of the controller (device number). -1 if the location cannot be detected. |
| 1.3.6.1.4.1.231.2.10.2.2.9.3.1.1.36 | ColumnfscDdmDwScPciFunction | read-only | mandatory | PCI location of the controller (function number). -1 if the location cannot be detected. |
| 1.3.6.1.4.1.231.2.10.2.2.9.3.1.1.37 | ColumnfscDdmDwScDriverName | read-only | mandatory | Name of the driver that handles the controller. |
| 1.3.6.1.4.1.231.2.10.2.2.9.3.1.1.38 | ColumnfscDdmDwScDriverDescription | read-only | mandatory | Description of the driver that handles the controller. Empty, if no description is available. |
| 1.3.6.1.4.1.231.2.10.2.2.9.4 | NodefscDdmMPContainer | |||
| 1.3.6.1.4.1.231.2.10.2.2.9.4.1 | TablefscDdmMpPieceTable | not-accessible | mandatory | Table of all paths MultiPath has detected. |
| 1.3.6.1.4.1.231.2.10.2.2.9.4.1.1 | RowfscDdmMpPiece | not-accessible | mandatory | Entry in table of MultiPath paths. |
| 1.3.6.1.4.1.231.2.10.2.2.9.4.1.1.1 | ColumnfscDdmMpIndex | read-only | mandatory | Unique value for each MultiPath path, starts at 0 and remains unchanged from one re-initialization of the agent to the next. Only used as index. |
| 1.3.6.1.4.1.231.2.10.2.2.9.4.1.1.2 | ColumnfscDdmMpMpPort | read-only | mandatory | Virtual SCSI port number of the MultiPath group. |
| 1.3.6.1.4.1.231.2.10.2.2.9.4.1.1.3 | ColumnfscDdmMpMpPath | read-only | mandatory | Virtual SCSI path number of the MultiPath group. |
| 1.3.6.1.4.1.231.2.10.2.2.9.4.1.1.4 | ColumnfscDdmMpMpTarget | read-only | mandatory | Virtual SCSI target ID of the MultiPath group. |
| 1.3.6.1.4.1.231.2.10.2.2.9.4.1.1.5 | ColumnfscDdmMpMpLun | read-only | mandatory | Virtual SCSI LUN of the MultiPath group. |
| 1.3.6.1.4.1.231.2.10.2.2.9.4.1.1.6 | ColumnfscDdmMpMpGroupNumber | read-only | mandatory | Internal group number of the MultiPath group. |
| 1.3.6.1.4.1.231.2.10.2.2.9.4.1.1.7 | ColumnfscDdmMpMpAutoRecovery | read-only | mandatory | AutoRecovery status of the MultiPath group. When AutoRecovery is turned on a repaired connection returns into a MultiPath group as Active or Standby otherwise … |
| 1.3.6.1.4.1.231.2.10.2.2.9.4.1.1.8 | ColumnfscDdmMpMpAutoFailback | read-only | mandatory | AutoFailback status of the MultiPath group. If AutoFailback is turned on a repaired connection returns into a MultiPath group in the state it was before the er… |
| 1.3.6.1.4.1.231.2.10.2.2.9.4.1.1.9 | ColumnfscDdmMpMpCabinetHandling | read-only | mandatory | Connected storage type. If this cannot be detected the value is UNKNOWN. Possible values are: DEFAULT S40, JBOD CLARIION FibreCAT UNKNOWN none of the above |
| 1.3.6.1.4.1.231.2.10.2.2.9.4.1.1.10 | ColumnfscDdmMpMpStatus | read-only | mandatory | Status of the MultiPath path. Possible values are: ACTIVE the piece can accept I/Os. When LoadBalancing is off only one path of a MultiPath group can be active… |
| 1.3.6.1.4.1.231.2.10.2.2.9.4.1.1.11 | ColumnfscDdmMpMpPreferred | read-only | mandatory | Flag which path of a MultiPath group will be active after an error situation is cleared. This flag is only valid in case of AutoFailback. Possible values are: … |
| 1.3.6.1.4.1.231.2.10.2.2.9.4.1.1.12 | ColumnfscDdmMpDwName | read-only | mandatory | Name of the DuplexWrite group where the MultiPath group is piece of. Empty, if the MultiPath group is not a member of a DuplexWrite group. |
| 1.3.6.1.4.1.231.2.10.2.2.9.4.1.1.13 | ColumnfscDdmMpDwGroupNumber | read-only | mandatory | Internal DuplexWrite group number where the MultiPath group is piece of. -1, if the MultiPath group is not a member of a DuplexWrite group. |
| 1.3.6.1.4.1.231.2.10.2.2.9.4.1.1.14 | ColumnfscDdmMpScPort | read-only | mandatory | Real SCSI port number of the MultiPath path. |
| 1.3.6.1.4.1.231.2.10.2.2.9.4.1.1.15 | ColumnfscDdmMpScPath | read-only | mandatory | Real SCSI path number of the MultiPath path. |
| 1.3.6.1.4.1.231.2.10.2.2.9.4.1.1.16 | ColumnfscDdmMpScTarget | read-only | mandatory | Real SCSI target ID of the MultiPath path. |
| 1.3.6.1.4.1.231.2.10.2.2.9.4.1.1.17 | ColumnfscDdmMpScLun | read-only | mandatory | Real SCSI LUN of the MultiPath path. |
| 1.3.6.1.4.1.231.2.10.2.2.9.4.1.1.18 | ColumnfscDdmMpScDiskNumber | read-only | mandatory | Operating system assigned disk number of the MultiPath path. |
| 1.3.6.1.4.1.231.2.10.2.2.9.4.1.1.19 | ColumnfscDdmMpScSize | read-only | mandatory | Capacity of the MultiPath path in MegaBytes. |
| 1.3.6.1.4.1.231.2.10.2.2.9.4.1.1.20 | ColumnfscDdmMpScSignature | read-only | mandatory | Operating system assigned unique key (signature) of the MultiPath path. If the signature cannot be detected or is not available the value is -1. |
| 1.3.6.1.4.1.231.2.10.2.2.9.4.1.1.21 | ColumnfscDdmMpScType | read-only | mandatory | The SCSI type of the MultiPath path. Possible values are: DISK direct access device TAPE tape device PRINTER printer device PROCESSOR processor device WORM wri… |
| 1.3.6.1.4.1.231.2.10.2.2.9.4.1.1.22 | ColumnfscDdmMpScInquiry | read-only | mandatory | SCSI inquiry string (vendor and product id) of the MultiPath path. |
| 1.3.6.1.4.1.231.2.10.2.2.9.4.1.1.23 | ColumnfscDdmMpScResource | read-only | mandatory | Cluster resource name of the MultiPath path. Empty, if the piece is not a cluster resource. |
| 1.3.6.1.4.1.231.2.10.2.2.9.4.1.1.24 | ColumnfscDdmMpScNode | read-only | mandatory | Cluster node name that owns the MultiPath path. Empty, if the piece is not a cluster resource. |
| 1.3.6.1.4.1.231.2.10.2.2.9.4.1.1.25 | ColumnfscDdmMpScPciBus | read-only | mandatory | PCI location of the controller (bus number). -1 if the location cannot be detected. |
| 1.3.6.1.4.1.231.2.10.2.2.9.4.1.1.26 | ColumnfscDdmMpScPciDevice | read-only | mandatory | PCI location of the controller (device number). -1 if the location cannot be detected. |
| 1.3.6.1.4.1.231.2.10.2.2.9.4.1.1.27 | ColumnfscDdmMpScPciFunction | read-only | mandatory | PCI location of the controller (function number). -1 if the location cannot be detected. |
| 1.3.6.1.4.1.231.2.10.2.2.9.4.1.1.28 | ColumnfscDdmMpScDriverName | read-only | mandatory | Name of the driver that handles the controller. |
| 1.3.6.1.4.1.231.2.10.2.2.9.4.1.1.29 | ColumnfscDdmMpScDriverDescription | read-only | mandatory | Description of the driver that handles the controller. Empty, if no description is available. |
| 1.3.6.1.4.1.231.2.10.2.2.9.10 | NodefscDdmTrapInfo | |||
| 1.3.6.1.4.1.231.2.10.2.2.9.10.1 | ScalarfscDdmTrapServerName | not-accessible | mandatory | Name of the server where the trap occured. |
| 1.3.6.1.4.1.231.2.10.2.2.9.10.2 | ScalarfscDdmTrapTime | not-accessible | mandatory | Time the trap occured (in seconds since 1/1/1970 00:00:00). |
| 1.3.6.1.4.1.231.2.10.2.2.9.10.3 | ScalarfscDdmTrapPort | not-accessible | mandatory | Physical SCSI port number where the change occured. |
| 1.3.6.1.4.1.231.2.10.2.2.9.10.4 | ScalarfscDdmTrapPath | not-accessible | mandatory | Physical SCSI path number where the change occured. |
| 1.3.6.1.4.1.231.2.10.2.2.9.10.5 | ScalarfscDdmTrapTarget | not-accessible | mandatory | Physical SCSI target ID where the change occured. |
| 1.3.6.1.4.1.231.2.10.2.2.9.10.6 | ScalarfscDdmTrapLun | not-accessible | mandatory | Physical SCSI LUN where the change occured. |
| 1.3.6.1.4.1.231.2.10.2.1400 | NodefscDdmNewConfig | The driver has created a new DuplexWrite group or has added a new piece to an existing DuplexWrite group as requested by the user. | ||
| 1.3.6.1.4.1.231.2.10.2.1401 | NodefscDdmPieceRemoved | The driver has removed a piece from a DuplexWrite group as requested by the user. | ||
| 1.3.6.1.4.1.231.2.10.2.1402 | NodefscDdmConfigRemoved | The driver has removed a DuplexWrite group as requested by the user. | ||
| 1.3.6.1.4.1.231.2.10.2.1403 | NodefscDdmStatusSet | The driver has set the status of a DuplexWrite piece as requested by the user. | ||
| 1.3.6.1.4.1.231.2.10.2.1404 | NodefscDdmUpdateStatus | The driver has updated the status of a DuplexWrite piece. | ||
| 1.3.6.1.4.1.231.2.10.2.1405 | NodefscDdmPieceRecovered | The driver has successfully recovered a DuplexWrite group. Both pieces are ONLINE. | ||
| 1.3.6.1.4.1.231.2.10.2.1406 | NodefscDdmRecoverAborted | The driver has aborted the recover process of a DuplexWrite group as requested by the user. | ||
| 1.3.6.1.4.1.231.2.10.2.1407 | NodefscDdmReservationConflict | The driver has detected a reservation conflict. A whole DuplexWrite group is not accessible from now on. This is only an error if it happens during operation (… | ||
| 1.3.6.1.4.1.231.2.10.2.1408 | NodefscDdmConfigChanged | The driver has done a rescan/reread and found a new configuration. | ||
| 1.3.6.1.4.1.231.2.10.2.1409 | NodefscDdmConfigInvalidated | The driver has invalidated the configuration information for a DuplexWrite group. The configuration information is reread before the next access of the DuplexW… | ||
| 1.3.6.1.4.1.231.2.10.2.1410 | NodefscDdmActiveLunChanged | The driver has selected a specified piece of a DuplexWrite group for read commands. | ||
| 1.3.6.1.4.1.231.2.10.2.1411 | NodefscDdmPieceFailed | The driver has detected an error on a DuplexWrite piece. | ||
| 1.3.6.1.4.1.231.2.10.2.1412 | NodefscDdmRootFlagChanged | The driver has changed the root behavior of a DuplexWrite group. | ||
| 1.3.6.1.4.1.231.2.10.2.1413 | NodefscDdmForceActive | The driver has marked a disk of a DuplexWrite group forced active at next boot. The partner disk can be used as Snapshot. | ||
| 1.3.6.1.4.1.231.2.10.2.1414 | NodefscDdmNameChanged | The driver has changed the name of a DuplexWrite group. | ||
| 1.3.6.1.4.1.231.2.10.2.1415 | NodefscDdmPathFailed | The driver has detected an error on one path of a MultiPath group. | ||
| 1.3.6.1.4.1.231.2.10.2.1416 | NodefscDdmRetry | The driver has detected an error on one path of a MultiPath group and the retry of the command was successful on another path. | ||
| 1.3.6.1.4.1.231.2.10.2.1417 | NodefscDdmActivePortChanged | The driver has changed the active path of a MultiPath group. | ||
| 1.3.6.1.4.1.231.2.10.2.1418 | NodefscDdmReconfigured | The driver has detected a MultiPath configuration change. | ||
| 1.3.6.1.4.1.231.2.10.2.1419 | NodefscDdmStatusChanged | The MultiPath status has changed.\nThe user has activated, disabled, ... the MultiPath path, or changed the failover policy.\nThe path has changed as request o… | ||
| 1.3.6.1.4.1.231.2.10.2.1420 | NodefscDdmAutoRecovered | The driver has enabled a path of a MultiPath group (AutoRecovery). | ||
| 1.3.6.1.4.1.231.2.10.2.1421 | NodefscDdmErrorCleared | The error of MultiPath path is cleared and reused (AutoFailback). | ||
| 1.3.6.1.4.1.231.2.10.2.1422 | NodefscDdmPnPRemove | A Plug and Play Removal of an device was detected. | ||
| 1.3.6.1.4.1.231.2.10.2.1423 | NodefscDdmPnPNew | A Plug and Play Add of an device was detected. | ||