Common parameters of SIAE equipments.
OIDNameAccessStatusDescription
1.3.6.1.4.1.3373.1103.0.109NotificationequipLOMConnectedMonitorcurrentThis event is generated by ALFOHD-NE when equipLOMConnected is set to Monitor mode. The data passed with the event are: 1) equipIpSnmpAgentAddress 2) equipLOMC…
1.3.6.1.4.1.3373.1103.0.110NotificationequipLOMConnectedConfigcurrentThis event is generated by ALFOHD-NE when equipLOMConnected is set to Configuration mode. The data passed with the event are: 1) equipIpSnmpAgentAddress 2) equ…
1.3.6.1.4.1.3373.1103.0.111NotificationequipLOMDisconnectedcurrentThis event is generated by ALFOHD-NE when LOMConnected is cleared. The data passed with the event are: 1) equipIpSnmpAgentAddress 2) equipLOMConnected
1.3.6.1.4.1.3373.1103.0.114NotificationequipConfigChangeStatuscurrentThis event is generated by ALFOHD-NE when equipConfigChange is changed. The data passed with the event are: 1) equipIpSnmpAgentAddress 2) equipConfigChange
1.3.6.1.4.1.3373.1103.0.123NotificationequipManagerWakeUpNotifycurrentThis trap is sent periodically only to the manager specified by the leaf equipManagerWakeUpIpAddr when equipManagerWakeUpAlarmSeverityCode differs from disable…
1.3.6.1.4.1.3373.1103.1IdentityequipmentCommon parameters of SIAE equipments.
1.3.6.1.4.1.3373.1103.1.1ScalarequipMibVersionread-onlycurrentNumerical version of this module. The string version of this MIB have the following format: XX.YY.ZZ so, for example, the value 1 should be interpreted as 00.0…
1.3.6.1.4.1.3373.1103.1.2ScalarequipCurrentTimeread-writecurrentSeconds since 1/1/1970.
1.3.6.1.4.1.3373.1103.1.3ScalarequipUpTimeread-onlycurrentThe time since the system was last re-initialized (in seconds since 1/1/1970).
1.3.6.1.4.1.3373.1103.1.4ScalarequipTyperead-onlycurrentType of SIAE MICROELETTRONICA's equipment
1.3.6.1.4.1.3373.1103.1.6ScalarequipIpEthOsiAddressread-writecurrentIp address of the equipment on Ethernet-OSI interface.
1.3.6.1.4.1.3373.1103.1.7ScalarequipGosipAddressread-writecurrentGOSIP address of the equipment.
1.3.6.1.4.1.3373.1103.1.8ScalarequipIpEthOsiNetMaskread-writecurrentThe subnet Mask associated with the IP address of OSI ethernet interface. The value of the Mask is an IP address with all the network bits set to 1 and all the…
1.3.6.1.4.1.3373.1103.1.9ScalarequipL1L2IsIsRoutingread-writecurrentIt defines the IS-IS routing type: L1 within the same area, L2 among different areas.
1.3.6.1.4.1.3373.1103.1.10ScalarequipStationIDread-writecurrentASCII string assigned by the operator to identify the specific equipment.
1.3.6.1.4.1.3373.1103.1.11ScalarequipLOMConfigEnableread-writecurrentEnables/disables the capabilityto connect a LOM in Configuration Mode.
1.3.6.1.4.1.3373.1103.1.12ScalarequipLOMConnectedread-onlycurrentSignal when the LOM is connected to the NE and if the connection is for monitor or configuration.
1.3.6.1.4.1.3373.1103.1.13ScalarequipLOMConnectedTrapEnableread-writecurrentEnables/disables the trap generation on EquipLOMConnected status change event.
1.3.6.1.4.1.3373.1103.1.14ScalarequipConfigChangeread-writecurrentSet by the NE when the equipment configuration is changed by the local or Remote LOM. The octet string is a bit stream of flags; a set bit is a change on a spe…
1.3.6.1.4.1.3373.1103.1.15ScalarequipConfigChangeTrapEnableread-writecurrentEnables/disables the trap generation on EquipConfigChange status change event.
1.3.6.1.4.1.3373.1103.1.16ScalarequipRequestread-writecurrentForce Equipment Controller restart or change in interface properties.
1.3.6.1.4.1.3373.1103.1.17ScalarequipIpEthAddressread-writecurrentIp address of the equipment on Ethernet interface.
1.3.6.1.4.1.3373.1103.1.18ScalarequipIpEthNetMaskread-writecurrentThe subnet Mask associated with the IP address of ethernet interface. The value of the Mask is an IP address with all the network bits set to 1 and all the hos…
1.3.6.1.4.1.3373.1103.1.19ScalarequipOsiamParameterread-writecurrentIt defines the set-up parameter for OSI stack.
1.3.6.1.4.1.3373.1103.1.20ScalarequipIpSnmpAgentAddressread-writecurrentIp address used by SNMP Agent for mark generated TRAP.
1.3.6.1.4.1.3373.1103.1.21ScalarequipOperationInProgressread-writecurrentA value different from 0 means operation in progress.
1.3.6.1.4.1.3373.1103.1.22ScalarequipManagerWakeUpAlarmread-onlycurrentThis alarm switches on when periodic connection wake-up trap starts. The trap related to this alarm is also sent periodically only to the manager specified by …
1.3.6.1.4.1.3373.1103.1.23ScalarequipManagerWakeUpAlarmSeverityCoderead-writecurrentDefines the severity associated to the equipManagerWakeUpAlarm and enables/disables the trap generation on status change event.
1.3.6.1.4.1.3373.1103.1.24ScalarequipManagerWakeUpTimeoutread-writecurrentThis object defines the time (in minutes) after which the periodic connection wake-up trap is stopped. The maximium value is equivalent to 24 hours. When the t…
1.3.6.1.4.1.3373.1103.1.25ScalarequipManagerWakeUpIpAddrread-writecurrentIp Address of manager wich to send a periodic connection wake-up trap. The periodic trap is sent only if the equipManagerWakeUpAlarmSeverityCode differs from d…
1.3.6.1.4.1.3373.1103.1.26ScalarequipManagerWakeUpGosipAddressread-writecurrentGosip Address of manager wich to send a periodic connection wake-up trap.
1.3.6.1.4.1.3373.1103.1.27ScalarequipManagerWakeUpTrapVersionread-writecurrentTrap version supported by Manager to wake-up.
1.3.6.1.4.1.3373.1103.1.28ScalarequipManager1IpAddrread-writecurrentFirst IP address of a SNMP Manager always logged to this equipment. The address 0.0.0.0 mean that manager is not present.
1.3.6.1.4.1.3373.1103.1.29ScalarequipManager2IpAddrread-writecurrentSecond IP address of a SNMP Manager always logged to this equipment. The address 0.0.0.0 mean that manager is not present.
1.3.6.1.4.1.3373.1103.1.30ScalarequipManager1TrapVersionread-writecurrentTrap version supported by Manager 1 (related to equipManager1IpAddr).
1.3.6.1.4.1.3373.1103.1.31ScalarequipManager2TrapVersionread-writecurrentTrap version supported by Manager 2 (related to equipManager2IpAddr).
1.3.6.1.4.1.3373.1103.1.32ScalarequipDailyPmTimeZoneread-writecurrentReference GMT Time Zone to close the daily P.M. records.
1.3.6.1.4.1.3373.1103.1.33ScalarequipOperationMngtControlread-writecurrentstartOperation means the apply of the 'management parameters set' on the E6165 switch. confirmOperation means the backup of the 'management parameters set'.
1.3.6.1.4.1.3373.1103.1.34ScalarequipOperationMngtInProgressread-onlycurrentA value different from 0 means Mngt operation in progress.
1.3.6.1.4.1.3373.1103.1.35ScalarequipLocationread-writecurrentASCII string assigned by the operator to identify the location of specific equipment.
1.3.6.1.4.1.3373.1103.1.36ScalarequipLongituderead-writecurrentGeographic coordinate that specifies the east-west position of the equipment. In order to calculate the latitude in degrees the formula to be applied is Longit…
1.3.6.1.4.1.3373.1103.1.37ScalarequipLatituderead-writecurrentGeographic coordinate that specifies the north-south position of the equipment. In order to calculate the latitude in degrees the formula to be applied is Lati…
1.3.6.1.4.1.3373.1103.1.38ScalarequipIpEthVlanIdread-writecurrentEthernet vlan id on top of which management is built
1.3.6.1.4.1.3373.1103.1.39ScalarequipIpEthDefGatewayread-writecurrentIp address of the default gateway on Ethernet interface.
1.3.6.1.4.1.3373.1103.1.40ScalarequipIpEthDefGatewayIfIndexread-writecurrentIp address of the default gateway on Ethernet interface.
1.3.6.1.4.1.3373.1103.1.41TableequipMngtTablenot-accessiblecurrentThis is the table that describes the DCN parameters. Two records are created, the first one represents the operational status, the other one represents the adm…
1.3.6.1.4.1.3373.1103.1.41.1RowequipMngtTableEntrynot-accessiblecurrentThe DCN parameters.
1.3.6.1.4.1.3373.1103.1.41.1.1ColumnequipMngtStatusread-onlycurrentThe index to select one of two records of table: the operational record and the administrative record.
1.3.6.1.4.1.3373.1103.1.41.1.2ColumnequipMngtIpAddressread-writecurrentThe IP address of the equipment.
1.3.6.1.4.1.3373.1103.1.41.1.3ColumnequipMngtIpNetMaskread-writecurrentThe network mask associated with the IP address.
1.3.6.1.4.1.3373.1103.1.41.1.4ColumnequipMngtIpDefGatewayread-writecurrentThe IP address of the default gateway.
1.3.6.1.4.1.3373.1103.1.41.1.5ColumnequipMngtIpDefGatewayIfIndexread-writecurrentThe interface selected to reach the default gateway. The special value 1 means that the snmp agent selects the interface whose IP address belongs to the defaul…
1.3.6.1.4.1.3373.1103.1.41.1.6ColumnequipMngtIfTyperead-writecurrentThe type of management interface: - value 1 for physical lan interface, - value 2 for virtual loopback interface, - value 3 for management over vlan interface.…
1.3.6.1.4.1.3373.1103.1.41.1.7ColumnequipMngtIfIdread-writecurrentThe identifier of management interface: - if equipMngtIfType is ethernet: equipMngtIfId is the ifIndex of interface; - if equipMngtIfType is loopback: equipMng…
1.3.6.1.4.1.3373.1103.1.41.1.8ColumnequipMngtIfPortVlanIdread-writecurrentThe ifIndex corresponding to the port registered to vlan ID; it is valid only when equipMngtIfType is vlan, whose value is in equipMngtIfId. This object can be…
1.3.6.1.4.1.3373.1103.1.42ScalarequipLastRestartTyperead-onlycurrentReport the last restart-type performed in the system.