SMARTD-MIB
93 objects
No module-level DESCRIPTION found.
Imported Objects
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.81.27 | NodesmartDevices | |||
| 1.3.6.1.4.1.81.27.1 | NodesmartGeneral | |||
| 1.3.6.1.4.1.81.27.1.1 | ScalarsmartGenSWVersion | read-only | mandatory | ASCII string for description and display of the smart device software version. |
| 1.3.6.1.4.1.81.27.1.2 | ScalarsmartGenOSVersion | read-only | mandatory | ASCII string for description and display of the smart device operating system (kernel) version. |
| 1.3.6.1.4.1.81.27.1.3 | ScalarsmartGenSoftwareDscr | read-only | mandatory | ASCII string for description and display of the smart device software information. |
| 1.3.6.1.4.1.81.27.1.4 | ScalarsmartGenBootVersion | read-only | mandatory | ASCII string for description and display of the smart device boot software version. |
| 1.3.6.1.4.1.81.27.1.5 | ScalarsmartGenReset | read-write | mandatory | Setting the value of this attribute to ON is interpreted as a reset command for the whole device. It initiates a complete re-initialization of the device. |
| 1.3.6.1.4.1.81.27.1.6 | ScalarsmartGenHardwareVersion | read-only | mandatory | ASCII string for description and display of the agent hardware version. |
| 1.3.6.1.4.1.81.27.1.7 | ScalarsmartGenMonitoringPort | read-only | mandatory | Enables a user to fix one port to monitor other segment ports. For the moment, the monitoring port is port 16. In this case, this port doesn't participate to a… |
| 1.3.6.1.4.1.81.27.1.8 | ScalarsmartGenMonitoredPort | read-write | mandatory | Value '0' is illegal when Monitor Mode is on. |
| 1.3.6.1.4.1.81.27.1.9 | ScalarsmartGenLastChange | read-only | mandatory | This attribute contains the value of sysUpTime at the time any change pertaining to the device: The changes are regarding the parameters of this group and any … |
| 1.3.6.1.4.1.81.27.1.10 | ScalarsmartGenMonitorMode | read-write | mandatory | Activates the monitor function. |
| 1.3.6.1.4.1.81.27.1.11 | ScalarsmartGenNetworkPrefix | read-write | mandatory | For ATM devices, the prefix of the switch connected. |
| 1.3.6.1.4.1.81.27.1.12 | ScalarsmartGenConnectMode | read-write | mandatory | Enables the user to configure the ATM interface of the smart device to work in front another ATM port of a smart device: pvc or in front a switch with lane10. |
| 1.3.6.1.4.1.81.27.1.13 | ScalarsmartGenPvcVP | read-only | mandatory | When the smart device is in mode pvc, the VP on which the data is runing. |
| 1.3.6.1.4.1.81.27.1.14 | ScalarsmartGenPvcVC | read-only | mandatory | When the smart device is in mode pvc, the VC on which the data is runing. |
| 1.3.6.1.4.1.81.27.1.15 | ScalarsmartGenSlotNumber | read-only | mandatory | Identifies the location (slot number) of the device in the chassis. The first slot is 1 |
| 1.3.6.1.4.1.81.27.1.16 | ScalarsmartGenHubMgmtIfType | read-only | mandatory | This attribute describes one of the interfaces of agents existing on modules and their type. Value 'none' defines the lack of an interface whose type is recogn… |
| 1.3.6.1.4.1.81.27.1.17 | ScalarsmartGenHubAddr | read-write | mandatory | This attribute defines an unique address by which the agent may be addressed by the management console. The address format should be consistent with the type d… |
| 1.3.6.1.4.1.81.27.2 | NodesmartAgent | |||
| 1.3.6.1.4.1.81.27.2.1 | ScalarsmartAgCoprocCommStatus | read-only | mandatory | Attribute describing the status of the communication between the agent and its coprocessor. |
| 1.3.6.1.4.1.81.27.2.2 | ScalarsmartAgCommDebugMode | read-write | mandatory | Attribute describing the agent mode in which communication problem traps are sent to managers (value 'on') or are not sent to managers (value 'off'). |
| 1.3.6.1.4.1.81.27.2.3 | ScalarsmartAgConfigChangeTraps | read-write | mandatory | The value of this attributes determines whether or not the agent sends Configuration Change traps to the manager. |
| 1.3.6.1.4.1.81.27.2.4 | ScalarsmartAgFaultTraps | read-write | mandatory | The value of this attributes determines whether or not the agent sends Fault traps to the manager. |
| 1.3.6.1.4.1.81.27.2.5 | ScalarsmartAgLaneFaultTraps | read-write | mandatory | The value of this attributes determines whether or not the agent sends Fault traps when it cannot connect to some ELAN to the manager. |
| 1.3.6.1.4.1.81.27.2.6 | ScalarsmartAgSoftwareStatus | read-write | mandatory | Describes configuration of the firmware on this agent. unLoadable(1) - is returned by agents which do not support the Software Download feature; loaded(2) - is… |
| 1.3.6.1.4.1.81.27.3 | NodesmartIfExtension | |||
| 1.3.6.1.4.1.81.27.3.1 | TablesmartIfExtensionTable | not-accessible | mandatory | This table contains additional information concerning physical interfaces. (Ethernet and ATM ports.) |
| 1.3.6.1.4.1.81.27.3.1.1 | RowsmartIfExtensionEntry | not-accessible | mandatory | Additional information |
| 1.3.6.1.4.1.81.27.3.1.1.1 | ColumnsmartIfExtensionEthStatus | read-only | mandatory | Valid for Ethernet Type only |
| 1.3.6.1.4.1.81.27.3.1.1.2 | ColumnsmartIfExtensionActivity | read-write | mandatory | Valid for ATM Type supporting redundancy. |
| 1.3.6.1.4.1.81.27.3.1.1.3 | ColumnsmartIfExtensionViNet | read-write | mandatory | Virtual Net Number. Value '0' for generic mode. The value for not supported is 511. |
| 1.3.6.1.4.1.81.27.3.1.1.4 | ColumnsmartIfExtensionPriorityLevel | read-write | mandatory | This attribute defines the priority levels of Ethernet ports. The highest priority is video. |
| 1.3.6.1.4.1.81.27.3.1.1.5 | ColumnsmartIfExtensionBridgeEnable | read-only | mandatory | Valid for Ethernet port when in sniffer mode. |
| 1.3.6.1.4.1.81.27.3.1.1.6 | ColumnsmartIfExtensionBackPressure | read-write | mandatory | Enables a user to disable the backpressure mechanism. |
| 1.3.6.1.4.1.81.27.3.1.1.7 | ColumnsmartIfExtensionSTAEnable | read-write | mandatory | Allows user to take out a port from the STA. |
| 1.3.6.1.4.1.81.27.4 | NodesmartViNet | |||
| 1.3.6.1.4.1.81.27.4.1 | ScalarsmartViNetMaxNumOfNets | read-only | mandatory | Maximum number of local ViNets supported. |
| 1.3.6.1.4.1.81.27.4.2 | ScalarsmartViNetCurrentBridge | read-write | mandatory | ViNet that is the current owner of the STA group, and forwarding table in the bridge MIB. |
| 1.3.6.1.4.1.81.27.4.3 | TablesmartViNetTable | not-accessible | mandatory | This table contains the number of members belonging to each virtual nets . |
| 1.3.6.1.4.1.81.27.4.3.1 | RowsmartViNetEntry | not-accessible | mandatory | Each Virtual Net will be an isolated entity. The first row of this table is the generic virtual net and is read-only. |
| 1.3.6.1.4.1.81.27.4.3.1.1 | ColumnsmartViNetNumberPlusOne | read-write | mandatory | Correspondance for Virtual Net: ViNet: zero is 'generic' |
| 1.3.6.1.4.1.81.27.4.3.1.2 | ColumnsmartViNetNumOfMembers | read-only | mandatory | Number of members. |
| 1.3.6.1.4.1.81.27.4.4 | TablesmartViNetElanTable | not-accessible | mandatory | This table contains all the information concerning the association between virtual nets and ELAN name. |
| 1.3.6.1.4.1.81.27.4.4.1 | RowsmartViNetElanEntry | not-accessible | mandatory | Each Virtual Net will be associated to an ELAN. The vinet = 0 is the first entry of the device. |
| 1.3.6.1.4.1.81.27.4.4.1.1 | ColumnsmartViNetElanAssociation | read-write | mandatory | The association number. For the first association, this entry is read-only. |
| 1.3.6.1.4.1.81.27.4.4.1.2 | ColumnsmartViNetElanViNet | read-write | mandatory | The virtual net number. For the first row, this entry is read-only. |
| 1.3.6.1.4.1.81.27.4.4.1.3 | ColumnsmartViNetElanName | read-write | mandatory | The ELAN name. For the first row, this entry is 'default' and is read-only. |
| 1.3.6.1.4.1.81.27.4.4.1.4 | ColumnsmartViNetElanEntryStatus | read-write | mandatory | The status of the entry. When the console starts to set the parameters of the row, the agent sets the status to notReady. The status createAndWait is set by th… |
| 1.3.6.1.4.1.81.27.4.4.1.5 | ColumnsmartViNetElanIfIndex | read-only | mandatory | Creating a row in this table causes the agent to add one row in the interface table. Before setting the row status to active, the agent fill this field with th… |
| 1.3.6.1.4.1.81.27.4.5 | TablesmartViNetFdbTable | not-accessible | mandatory | This table is the forwarding table per virtual net. |
| 1.3.6.1.4.1.81.27.4.5.1 | RowsmartViNetFdbEntry | not-accessible | mandatory | The forwarding tables. The smartViNetFdbPlusOne = 1 corresponds to ViNet generic. |
| 1.3.6.1.4.1.81.27.4.5.1.1 | ColumnsmartViNetFdbPlusOne | read-only | mandatory | This table is indexed by the virtual net number plus 1, since the first group is '0'. |
| 1.3.6.1.4.1.81.27.4.5.1.2 | ColumnsmartViNetFdbAddress | read-only | mandatory | A unicast MAC address for which the bridge has forwarding and/or filtering information. |
| 1.3.6.1.4.1.81.27.4.5.1.3 | ColumnsmartViNetFdbPort | read-only | mandatory | Either the value '0', or the port number of the port on which a frame having a source address equal to the value of the corresponding instance of dot1dTpFdbAdd… |
| 1.3.6.1.4.1.81.27.4.5.1.4 | ColumnsmartViNetFdbStatus | read-only | mandatory | see dot1dTpFdbStatus. |
| 1.3.6.1.4.1.81.27.4.6 | TablesmartViNetStpTable | not-accessible | mandatory | This table contains all the information concerning the STA parameters per group. |
| 1.3.6.1.4.1.81.27.4.6.1 | RowsmartViNetStpEntry | not-accessible | mandatory | The bridge will function between each of those entries. |
| 1.3.6.1.4.1.81.27.4.6.1.1 | ColumnsmartViNetStpPlusOne | read-only | mandatory | This table is indexed by the virtual net number plus 1, since the first group is '0'. |
| 1.3.6.1.4.1.81.27.4.6.1.2 | ColumnsmartViNetStpPriority | read-write | mandatory | |
| 1.3.6.1.4.1.81.27.4.6.1.3 | ColumnsmartViNetStpTimeSinceTopologyChange | read-only | mandatory | The time (in hundredths of a second) since the last time a topology change was detected by the bridge entity. |
| 1.3.6.1.4.1.81.27.4.6.1.4 | ColumnsmartViNetStpTopChanges | read-only | mandatory | The total number of topology changes detected by this bridge since the management entity was last reset or initialized. |
| 1.3.6.1.4.1.81.27.4.6.1.5 | ColumnsmartViNetStpDesignatedRoot | read-only | mandatory | The bridge identifier of the root of the spanning tree as determined by the Spanning Tree Protocol as executed by this node. This value is used as the Root Ide… |
| 1.3.6.1.4.1.81.27.4.6.1.6 | ColumnsmartViNetStpRootCost | read-only | mandatory | The cost of the path to the root as seen from this bridge. |
| 1.3.6.1.4.1.81.27.4.6.1.7 | ColumnsmartViNetStpRootPort | read-only | mandatory | The port number of the port which offers the lowest cost path from this bridge to the root bridge. |
| 1.3.6.1.4.1.81.27.4.6.1.8 | ColumnsmartViNetStpMaxAge | read-only | mandatory | The maximum age of Spanning Tree Protocol information learned from the network on any port before it is discarded, in units of hundredths of a second. This is … |
| 1.3.6.1.4.1.81.27.4.6.1.9 | ColumnsmartViNetStpHelloTime | read-only | mandatory | The amount of time between the transmission of Configuration bridge PDUs by this node on any port when it is the root of the spanning tree or trying to become … |
| 1.3.6.1.4.1.81.27.4.6.1.10 | ColumnsmartViNetStpHoldTime | read-only | mandatory | This time value determines the interval length during which no more than two Configuration bridge PDUs shall be transmitted by this node, in units of hundredth… |
| 1.3.6.1.4.1.81.27.4.6.1.11 | ColumnsmartViNetStpForwardDelay | read-only | mandatory | |
| 1.3.6.1.4.1.81.27.4.6.1.12 | ColumnsmartViNetStpBridgeMaxAge | read-write | mandatory | |
| 1.3.6.1.4.1.81.27.4.6.1.13 | ColumnsmartViNetStpBridgeHelloTime | read-write | mandatory | The value that all bridges use for HelloTime when this bridge is acting as the root. The granularity of this timer is specified by 802.1d/D9 to be 1 second. An… |
| 1.3.6.1.4.1.81.27.4.6.1.14 | ColumnsmartViNetStpBridgeForwardDelay | read-write | mandatory | |
| 1.3.6.1.4.1.81.27.4.6.1.15 | ColumnsmartViNetStpLastChange | read-only | mandatory | This attribute contains the value of sysUpTime at the time any change pertaining to the specified STA occurred. |
| 1.3.6.1.4.1.81.27.4.7 | ScalarsmartViNetConsoleManagement | read-write | mandatory | The ViNet to which the console belongs to. |
| 1.3.6.1.4.1.81.27.5 | NodesmartFatherHub | |||
| 1.3.6.1.4.1.81.27.5.1 | ScalarsmartFatherNumberOfMac | read-only | mandatory | Number of MAC Addresses of the box agent. |
| 1.3.6.1.4.1.81.27.5.2 | ScalarsmartFatherMacList | read-only | mandatory | This variable is the list of Mac Addresses of the box agent. |
| 1.3.6.1.4.1.81.27.6 | NodesmartLSFddi | |||
| 1.3.6.1.4.1.81.27.6.1 | TablesmartLSFTable | not-accessible | mandatory | This table contains the MAC addresses of all LSF100 modules on the FDDI ring. This information is needed for LANNET Topology application. |
| 1.3.6.1.4.1.81.27.6.1.1 | RowsmartLSFEntry | not-accessible | mandatory | A table entry containing MAC addresses of all LSF100 modules on the FDDI ring. |
| 1.3.6.1.4.1.81.27.6.1.1.1 | ColumnsmartLSFMACAddr | read-only | mandatory | This item defines the MAC address of an LSF100 connected to the FDDI ring. |
| 1.3.6.1.4.1.81.27.6.1.1.2 | ColumnsmartLSFEntryStatus | read-only | mandatory | Only the status active(1) is relevant to this table. |
| 1.3.6.1.4.1.81.27.6.2 | ScalarmacInFrames | read-only | mandatory | A count of the number of frames received by this MAC. |
| 1.3.6.1.4.1.81.27.6.3 | ScalarmacCopiedFrames | read-only | mandatory | A count of the number of frames addressed to and successfully copied into the station's receive buffers by this MAC. This count does not include MAC frames. |
| 1.3.6.1.4.1.81.27.6.4 | ScalarmacOutFrames | read-only | mandatory | A count of the number of frames trasmitted by this MAC. This count does not include MAC frames. |
| 1.3.6.1.4.1.81.27.6.5 | ScalarmacTokenRcvd | read-only | mandatory | A count of the number of times the station has received a token on this MAC. |
| 1.3.6.1.4.1.81.27.6.6 | ScalarmacErrFrames | read-only | mandatory | A count of the number of frames that were detected in error by this MAC that had not been detected in error by another MAC. |
| 1.3.6.1.4.1.81.27.6.7 | ScalarmacLostFrames | read-only | mandatory | A count of the number of instances that this MAC detected a format error during frame reception, such that the frame was stripped. |
| 1.3.6.1.4.1.81.27.6.8 | ScalarmacNotCopiedFrames | read-only | mandatory | A count of the number of frames addressed to this MAC but were not copied into the station's receive buffers. This count does not include MAC frames. |
| 1.3.6.1.4.1.81.27.6.9 | ScalarmacRingOpState | read-only | mandatory | A count of the number of times the ring has entered the Ring Operational state from the Ring Not Operational state. |
| 1.3.6.1.4.1.81.27.6.10 | ScalarfddiRingUtilization | read-only | mandatory | A utilization of the FDDI ring, attached to the LSF100 modules (or other members in the family). |
Type Definitions
| Name | Syntax | Status | Description |
|---|---|---|---|
| MacAddress | OCTET STRING (SIZE (6)) | ||
| Timeout | INTEGER |