MIB Viewer

SNI-SERVER-CONTROL-MIB

413 objects
No module-level DESCRIPTION found.
OIDNameAccessStatusDescription
1.3.6.1.4.1Nodeenterprises
1.3.6.1.4.1.231Nodesni
1.3.6.1.4.1.231.2NodesniProductMibs
1.3.6.1.4.1.231.2.10NodesniExtensions
1.3.6.1.4.1.231.2.10.2NodesniServerMgmt
1.3.6.1.4.1.231.2.10.2.1NodesniInventory
1.3.6.1.4.1.231.2.10.2.2NodesniCommon
1.3.6.1.4.1.231.2.10.2.2.1NodesniBios
1.3.6.1.4.1.231.2.10.2.2.2NodesniEisa
1.3.6.1.4.1.231.2.10.2.2.3NodesniHd
1.3.6.1.4.1.231.2.10.2.2.4NodesniBus
1.3.6.1.4.1.231.2.10.2.2.5NodesniServerControl
1.3.6.1.4.1.231.2.10.2.2.5.1NodeagentInfo
1.3.6.1.4.1.231.2.10.2.2.5.1.1ScalaragentIdread-onlymandatoryAgent identification string
1.3.6.1.4.1.231.2.10.2.2.5.1.2ScalaragentCompanyread-onlymandatoryAgent's company name
1.3.6.1.4.1.231.2.10.2.2.5.1.3ScalaragentVersionStringread-onlymandatoryAgent's version string <Major>.<Minor> (i.e. 1.05)
1.3.6.1.4.1.231.2.10.2.2.5.1.4ScalaragentBuildread-onlymandatoryCompilation time and date of agent program
1.3.6.1.4.1.231.2.10.2.2.5.1.5ScalaragentVersionMajorread-onlymandatoryAgent's major version (numerical)
1.3.6.1.4.1.231.2.10.2.2.5.1.6ScalaragentVersionMinorread-onlymandatoryAgent's minor version (numerical)
1.3.6.1.4.1.231.2.10.2.2.5.1.7ScalaragentWriteAllowedread-onlymandatoryDefines whether writable objects can be written (except shutdown/power-off operations)
1.3.6.1.4.1.231.2.10.2.2.5.1.8ScalaragentShutdownAllowedread-onlymandatoryDefines whether shutdown/power-off objects can be written
1.3.6.1.4.1.231.2.10.2.2.5.2Nodeenvironment
1.3.6.1.4.1.231.2.10.2.2.5.2.1TabletemperatureSensorsTablenot-accessiblemandatoryTable with data of all configured temperature sensors
1.3.6.1.4.1.231.2.10.2.2.5.2.1.1RowtemperatureSensorsnot-accessiblemandatory
1.3.6.1.4.1.231.2.10.2.2.5.2.1.1.1ColumntempCabinetIdread-onlymandatoryID of the cabinet the temperature sensor is in (index, 0 based)
1.3.6.1.4.1.231.2.10.2.2.5.2.1.1.2ColumntempSensorNumberread-onlymandatoryNumber of the sensor in this cabinet (index, 0 based)
1.3.6.1.4.1.231.2.10.2.2.5.2.1.1.3ColumntempSensorStatusread-onlymandatoryStatus of this temperature sensor (OK, critical or shutdown temperature reached...). The cold and the damage temperature status levels are no longer supported …
1.3.6.1.4.1.231.2.10.2.2.5.2.1.1.4ColumntempSensorPurposeread-onlymandatoryPurpose of this temperature sensor (CPU, ambient, housing...). Purposes disable(2) and not-available(6) are no longer used.
1.3.6.1.4.1.231.2.10.2.2.5.2.1.1.5ColumntempLowerWarningLevelread-onlyobsoleteObject made obsolete - no longer supported
1.3.6.1.4.1.231.2.10.2.2.5.2.1.1.6ColumntempUpperWarningLevelread-onlymandatorySystem sends a temperature warning when temperature rises ABOVE this level (degrees Celsius)
1.3.6.1.4.1.231.2.10.2.2.5.2.1.1.7ColumntempLowerCriticalLevelread-onlyobsoleteObject made obsolete - no longer supported
1.3.6.1.4.1.231.2.10.2.2.5.2.1.1.8ColumntempUpperCriticalLevelread-onlymandatorySystem becomes critical when temperature rises ABOVE this level (degrees Celsius). A system shutdown is performed if object tempCriticalReaction is set to shut…
1.3.6.1.4.1.231.2.10.2.2.5.2.1.1.9ColumntempLowerDamageLevelread-onlyobsoleteObject made obsolete - no longer supported
1.3.6.1.4.1.231.2.10.2.2.5.2.1.1.10ColumntempUpperDamageLevelread-onlyobsoleteObject made obsolete - no longer supported
1.3.6.1.4.1.231.2.10.2.2.5.2.1.1.11ColumntempCurrentValueread-onlymandatoryCurrent temperature value (degrees Celsius; -1: unknown temperature, problem with sensor, see tempSensorStatus)
1.3.6.1.4.1.231.2.10.2.2.5.2.1.1.12ColumntempCriticalReactionread-writemandatoryReaction when a temperature gets critical (shutdown and power-off, continue...). The value unknown(1) cannot be set, a SET will deliver 'badValue'.
1.3.6.1.4.1.231.2.10.2.2.5.2.1.1.13ColumntempSensorDesignationread-onlyoptionalString describing the purpose of each temperature sensor in a housing (e.g. CPU, ambient,...). This object will substitute the tempSensorPurpose object.
1.3.6.1.4.1.231.2.10.2.2.5.2.2TablefansTablenot-accessiblemandatoryTable with data of all configured cooling devices (fans)
1.3.6.1.4.1.231.2.10.2.2.5.2.2.1Rowfansnot-accessiblemandatory
1.3.6.1.4.1.231.2.10.2.2.5.2.2.1.1ColumnfanCabinetIdread-onlymandatoryID of the cabinet the cooling device (fan) is in (index, 0 based)
1.3.6.1.4.1.231.2.10.2.2.5.2.2.1.2ColumnfanNumberread-onlymandatoryNumber of the fan in this cabinet (index, 0 based)
1.3.6.1.4.1.231.2.10.2.2.5.2.2.1.3ColumnfanStatusread-onlymandatoryStatus of this fan (OK, failed...). Status disabled(2) is no longer used. Status prefailure-predicted(5) means the fan will fail in near future. Status redunda…
1.3.6.1.4.1.231.2.10.2.2.5.2.2.1.4ColumnfanPurposeread-onlymandatoryPurpose of this fan (housing, component, CPU on-chip, power supply...). Purpose disabled(2) is currently not used.
1.3.6.1.4.1.231.2.10.2.2.5.2.2.1.5ColumnfanPositionXread-onlyobsoleteFax X position - obsolete; for fan indentifying use fanIdentification object
1.3.6.1.4.1.231.2.10.2.2.5.2.2.1.6ColumnfanPositionYread-onlyobsoleteFax Y position - obsolete; for fan indentifying use fanIdentification object
1.3.6.1.4.1.231.2.10.2.2.5.2.2.1.7ColumnfanPositionZread-onlyobsoleteFax Z position - obsolete; for fan indentifying use fanIdentification object
1.3.6.1.4.1.231.2.10.2.2.5.2.2.1.8ColumnfanCurrentSpeedread-onlymandatoryCurrent speed of the fan (in revolutions per minute, -1 = unknown)
1.3.6.1.4.1.231.2.10.2.2.5.2.2.1.9ColumnfanNominalMaximumSpeedread-onlymandatoryNominal speed of the fan (in revolutions per minute) on maximum power; the speed is measured the first time the agent is installed and than compared daily to t…
1.3.6.1.4.1.231.2.10.2.2.5.2.2.1.10ColumnfanCurrentMaximumSpeedread-onlymandatoryCurrent speed of the fan (in revolutions per minute) on maximum power (-1 = unknown).
1.3.6.1.4.1.231.2.10.2.2.5.2.2.1.11ColumnfanMaximumSpeedCriticalLevelread-onlyobsoleteObsolete - no longer supported.
1.3.6.1.4.1.231.2.10.2.2.5.2.2.1.12ColumnfanMinimumSpeedread-onlyobsoleteObsolete - no longer supported.
1.3.6.1.4.1.231.2.10.2.2.5.2.2.1.14ColumnfanFailReactionread-writemandatoryReaction when a fan has failed (shutdown and power-off, continue...). The value unknown(1) cannot be set, a SET will deliver 'badValue'.
1.3.6.1.4.1.231.2.10.2.2.5.2.2.1.15ColumnfanFailShutdownDelayread-writemandatoryDelay time (in seconds) when shutdown should commit on fan fail (if shutdown-and-off is configured, 0 = immediately, -1 = unknown). The value unknown(-1) canno…
1.3.6.1.4.1.231.2.10.2.2.5.2.2.1.16ColumnfanDesignationread-writeoptionalString describing the purpose of each fan in a housing (e.g. CPU, Power Supply,...). This object will substitute the fanPurpose object.
1.3.6.1.4.1.231.2.10.2.2.5.2.2.1.17ColumnfanIdentificationread-writeoptionalString identifying each fan in a housing (e.g. CPU0, CPU1, PS0...)
1.3.6.1.4.1.231.2.10.2.2.5.2.3ScalarfanDailyTestTimeread-writemandatoryDaily time when to automatically test fan speeds (in minutes since midnight; -1 = unknown, automatic fan test not supported). The value unknown(-1) cannot be s…
1.3.6.1.4.1.231.2.10.2.2.5.2.4ScalarfanStartTestread-writemandatoryStart test of all fans to get the speed at maximum power (this test is normally started automatically once a day). Reading this object just returns the value 0.
1.3.6.1.4.1.231.2.10.2.2.5.3NodeerrorHandling
1.3.6.1.4.1.231.2.10.2.2.5.3.1TableeventLogTablenot-accessiblemandatoryTable with event log entries (can also contain critical errors when an ErrorLog for critical errors is not available)
1.3.6.1.4.1.231.2.10.2.2.5.3.1.1RoweventLognot-accessiblemandatory
1.3.6.1.4.1.231.2.10.2.2.5.3.1.1.1ColumneventLogEntryNumberread-onlymandatoryEntry number in eventLogTable (index, 0 based)
1.3.6.1.4.1.231.2.10.2.2.5.3.1.1.2ColumneventLogMessageDataread-onlymandatoryNon-critical message log entry as described above
1.3.6.1.4.1.231.2.10.2.2.5.3.2ScalareventLogMaxEntriesread-onlymandatoryNumber of EventLog entries (can be used to directly get all table entries with one varbind list)
1.3.6.1.4.1.231.2.10.2.2.5.3.3TableerrorLogTablenot-accessibleoptionalTable with major and critial error log entries (can be missing on some hardware platforms)
1.3.6.1.4.1.231.2.10.2.2.5.3.3.1RowerrorLognot-accessibleoptional
1.3.6.1.4.1.231.2.10.2.2.5.3.3.1.1ColumnerrorLogEntryNumberread-onlymandatoryEntry number in critical errorLogTable (index, 0 based)
1.3.6.1.4.1.231.2.10.2.2.5.3.3.1.2ColumnerrorLogMessageDataread-onlymandatoryMajor/critical message log entry as described above
1.3.6.1.4.1.231.2.10.2.2.5.3.4ScalarerrorLogMaxEntriesread-onlymandatoryNumber of ErrorLog entries (can be used to directly get all table entries with one varbind list)
1.3.6.1.4.1.231.2.10.2.2.5.3.5ScalarhardwareWatchdogStatusread-onlymandatoryStatus of the hardware watchdog (periodically restarted by the server management BIOS). The hardware watchdog is only supported on SMI based management hardwar…
1.3.6.1.4.1.231.2.10.2.2.5.3.6ScalarhardwareWatchdogTimeread-onlyobsoleteTimeout time of the hardware watchdog (in seconds, -1 = unknown)
1.3.6.1.4.1.231.2.10.2.2.5.3.7ScalarhardwareWatchdogEnableread-writemandatoryEnable/disable the hardware watchdog. The value unknown(1) cannot be set, a SET will deliver 'badValue'.
1.3.6.1.4.1.231.2.10.2.2.5.3.8ScalarsoftwareWatchdogStatusread-onlymandatoryStatus of the software watchdog (periodically restarted by the server management agent)
1.3.6.1.4.1.231.2.10.2.2.5.3.9ScalarsoftwareWatchdogTimeread-writemandatoryTimeout time of the software watchdog (in minutes, -1 = unknown). The value unknown(-1) cannot be set, a SET will deliver 'badValue'.
1.3.6.1.4.1.231.2.10.2.2.5.3.10ScalarsoftwareWatchdogEnableread-writemandatoryEnable/disable the software watchdog. The value unknown(-1) cannot be set, a SET will deliver 'badValue'.
1.3.6.1.4.1.231.2.10.2.2.5.3.11ScalarsoftwareWatchdogActionread-writemandatoryBehavior when the software watchdog timeout occurs (reboot, continue...). This value is only used if the watchdog is enabled. If set to continue and the watchd…
1.3.6.1.4.1.231.2.10.2.2.5.3.12ScalarbootWatchdogStatusread-onlymandatoryStatus of the boot watchdog (started at system boot, reset by the server management agent). If the SC agent is not started within the specified time, the manag…
1.3.6.1.4.1.231.2.10.2.2.5.3.13ScalarbootWatchdogTimeread-writemandatoryTimeout time of the boot watchdog (in minutes, -1 = unknown). The value unknown(-1) cannot be set, a SET will deliver 'badValue'.
1.3.6.1.4.1.231.2.10.2.2.5.3.14ScalarbootWatchdogEnableread-writemandatoryEnable/disable the boot watchdog. The value unknown(-1) cannot be set, a SET will deliver 'badValue'.
1.3.6.1.4.1.231.2.10.2.2.5.3.15ScalarbootWatchdogActionread-writemandatoryBehavior when the boot watchdog timeout occurs (reboot, continue...). This value is only used if the watchdog is enabled. If set to continue and the watchdog h…
1.3.6.1.4.1.231.2.10.2.2.5.4NodesystemBoard
1.3.6.1.4.1.231.2.10.2.2.5.4.1TablecpuTablenot-accessiblemandatoryTable with CPU information
1.3.6.1.4.1.231.2.10.2.2.5.4.1.1Rowcpunot-accessiblemandatory
1.3.6.1.4.1.231.2.10.2.2.5.4.1.1.1ColumncpuTableIndexread-onlymandatoryNumber of the CPU in the CpuTable (index, 0 based)
1.3.6.1.4.1.231.2.10.2.2.5.4.1.1.2ColumncpuTyperead-onlymandatoryType of the CPU (486, Pentium, R2000...)
1.3.6.1.4.1.231.2.10.2.2.5.4.1.1.3ColumncpuFrequencyread-onlymandatoryFrequency of the CPU (in MHz, -1 = unknown)
1.3.6.1.4.1.231.2.10.2.2.5.4.1.1.4ColumncpuStepread-onlymandatoryStep (version) of the CPU (-1 = unknown)
1.3.6.1.4.1.231.2.10.2.2.5.4.1.1.6ColumncpuStatusread-onlymandatoryStatus of a CPU: unknown(1) : CPU status could not be evaluated disabled(2) : CPU was manually disabled in BIOS setup ok(3) : CPU is available and operating pr…
1.3.6.1.4.1.231.2.10.2.2.5.4.1.1.7ColumncpuModelread-onlymandatoryModel of the CPU (-1 = unknown)
1.3.6.1.4.1.231.2.10.2.2.5.4.1.1.8ColumncpuNameread-onlymandatoryName of the CPU (e.g. 'Pentium', 'Pentium Pro' ...) as text string
1.3.6.1.4.1.231.2.10.2.2.5.4.1.1.9ColumncpuSocketDesignationread-onlymandatoryString containing the socket designation of a CPU. This is the same text that is written on the system board.
1.3.6.1.4.1.231.2.10.2.2.5.4.1.1.10ColumncpuManufacturerread-onlymandatoryString containing the CPU manufacturer.
1.3.6.1.4.1.231.2.10.2.2.5.4.1.1.11ColumncpuNrLogicalsPerPhysicalread-onlymandatoryNumber of logical CPUs within one physical CPU (for hyper-threading and multi-core CPUs). This is the sum of all cores and all logical CPUs of a hyper-threadin…
1.3.6.1.4.1.231.2.10.2.2.5.4.1.1.12ColumncpuCacheL1Sizeread-onlymandatoryLevel 1 cache size (kByte) of a physical CPU (0 if unknown or not available).
1.3.6.1.4.1.231.2.10.2.2.5.4.1.1.13ColumncpuCacheL2Sizeread-onlymandatoryLevel 2 cache size (kByte) of a physical CPU (0 if unknown or not available).
1.3.6.1.4.1.231.2.10.2.2.5.4.1.1.14ColumncpuCacheL3Sizeread-onlymandatoryLevel 3 cache size (kByte) of a physical CPU (0 if unknown or not available).
1.3.6.1.4.1.231.2.10.2.2.5.4.1.1.15ColumncpuNrCoresPerPhysicalread-onlymandatoryNumber of cores within one physical CPU (for multi-core CPUs).
1.3.6.1.4.1.231.2.10.2.2.5.4.2ScalarsecondLevelCacheSizeread-onlymandatorySize of the second level cache (in kBytes, 0 if not available or disabled, -1 = unknown). Object will be made obsolete in next releases; use cpuCacheL2Size ins…
1.3.6.1.4.1.231.2.10.2.2.5.4.3ScalarsecondLevelCacheWritePolicyread-onlymandatoryWrite policy of the second level cache (write-back, write-through). Object will be made obsolete in next releases (no longer required).
1.3.6.1.4.1.231.2.10.2.2.5.4.4ScalarphysicalMemorySizeread-onlymandatorySize of the whole physical memory on the system board (in MBytes, -1 = unknown)
1.3.6.1.4.1.231.2.10.2.2.5.4.5ScalarbaseMemorySizeread-onlymandatorySize of the base memory (below 1 MB) on the system board (in kBytes, -1 = unknown)
1.3.6.1.4.1.231.2.10.2.2.5.4.6ScalarextendedMemorySizeread-onlymandatorySize of the extended memory (above 1 MB) on the system board (in MBytes, -1 = unknown)
1.3.6.1.4.1.231.2.10.2.2.5.4.7ScalarutilizationMethodread-writeoptionalMethod to get utilization values: take-snapshot-now: get all values and store them to have all values at one certain time (set this object each time you want t…
1.3.6.1.4.1.231.2.10.2.2.5.4.8ScalarutilizationPciLoadread-onlyoptionalLoad on the PCI bus (in percent; -1 if unknown); do no longer use this object for new implementations; object replaced by pciUtilizationTable.
1.3.6.1.4.1.231.2.10.2.2.5.4.9ScalarutilizationEisaLoadread-onlyoptionalLoad on the EISA bus (in percent; -1 if unknown)
1.3.6.1.4.1.231.2.10.2.2.5.4.10TablememoryModulesTablenot-accessiblemandatoryTable with memory module descripitions
1.3.6.1.4.1.231.2.10.2.2.5.4.10.1RowmemoryModulesnot-accessiblemandatory
1.3.6.1.4.1.231.2.10.2.2.5.4.10.1.1ColumnmemModuleNumberread-onlymandatoryModule number (index, 0 based)
1.3.6.1.4.1.231.2.10.2.2.5.4.10.1.2ColumnmemModuleBankread-onlymandatoryBank number the module belongs to (-1 = unknown).
1.3.6.1.4.1.231.2.10.2.2.5.4.10.1.3ColumnmemModuleStatusread-onlymandatoryStatus of the memory module socket (OK, fail, disabled...). unknown(1) : module status could not be evaluated error(2) : module has encountered errors but is s…
1.3.6.1.4.1.231.2.10.2.2.5.4.10.1.4ColumnmemModuleErrorsread-onlymandatoryNumber of (parity) errors in this module since last error count reset (-1 = unknown)
1.3.6.1.4.1.231.2.10.2.2.5.4.10.1.5ColumnmemModuleStartAddressread-onlymandatoryStart address of the bank this memory belongs to (-1 = unknown). This object is obsolete when the main memory size exceeds 2 GByte. Use new object memModuleSta…
1.3.6.1.4.1.231.2.10.2.2.5.4.10.1.6ColumnmemModuleSizeread-onlymandatorySize of this memory module (in bytes, -1 = unknown). This object is obsolete when the module's size exceeds 2 GByte. Use new object memModuleSizeMB instead.
1.3.6.1.4.1.231.2.10.2.2.5.4.10.1.7ColumnmemModuleTyperead-onlymandatoryType of memory module (Parity, NoParity, ECD, EDO...). Will be made obsolete in next agent releases!!! Use memModuleType2 for newer implementations!
1.3.6.1.4.1.231.2.10.2.2.5.4.10.1.8ColumnmemModuleType2read-onlymandatoryInformation about the type of a memory module (Parity, ECC, EDO, SIMM, DIMM...). The type is a combination of one or more bits. Bit field: Bit 0 - Other Bit 1 …
1.3.6.1.4.1.231.2.10.2.2.5.4.10.1.9ColumnmemModuleSocketDesignationread-onlymandatoryString containing the socket designation of a memory module. This is the same text that is written on the system board.
1.3.6.1.4.1.231.2.10.2.2.5.4.10.1.10ColumnmemModuleCorrectableErrorsread-onlymandatoryNumber of correctable errors in this module since last error count reset (-1 = unknown)
1.3.6.1.4.1.231.2.10.2.2.5.4.10.1.11ColumnmemModuleApprovedread-onlymandatoryInformation whether the memory module has been approved by the system vendor. unknown(1) is given when a module is not available or module cannot be accessed; …
1.3.6.1.4.1.231.2.10.2.2.5.4.10.1.12ColumnmemModuleStartAddressMBread-onlymandatoryStart address (in MBytes) of the bank this memory belongs to (-1 = unknown). This object makes the object memModuleStartAddress obsolete (4 GByte limit).
1.3.6.1.4.1.231.2.10.2.2.5.4.10.1.13ColumnmemModuleSizeMBread-onlymandatorySize (in MBytes) of this memory module (-1 = unknown). This object makes the object memModuleSize obsolete (4 GByte limit).
1.3.6.1.4.1.231.2.10.2.2.5.4.11ScalarmemoryErrorCounterResetread-writemandatoryReset the memory module error counters (and set a new start time), reading this object just returns the value 0.
1.3.6.1.4.1.231.2.10.2.2.5.4.12ScalarmemoryErrorCounterStartTimeread-onlymandatoryTime when memory module error counters were started (seconds since 1/1/1970, -1 = unknown)
1.3.6.1.4.1.231.2.10.2.2.5.4.13TablepciUtilizationTablenot-accessiblemandatoryTable with PCI bus utilization data; independent of utilizationMethod object, update method for this table is always get-current-values. The number of entries …
1.3.6.1.4.1.231.2.10.2.2.5.4.13.1RowpciUtilizationnot-accessiblemandatory
1.3.6.1.4.1.231.2.10.2.2.5.4.13.1.1ColumnpciUtilBusNumberread-onlymandatoryPCI bus number (index, 1..n)
1.3.6.1.4.1.231.2.10.2.2.5.4.13.1.2ColumnpciUtilBusLoadread-onlymandatoryPCI bus load (in percent, 0xffffffff if unknown)
1.3.6.1.4.1.231.2.10.2.2.5.4.13.1.3ColumnpciUtilBusTransferRateread-onlymandatoryPCI bus data transfer rate (in MBytes/second, 0xffffffff if unknown)
1.3.6.1.4.1.231.2.10.2.2.5.4.13.1.4ColumnpciUtilBusEfficiencyread-onlymandatoryPCI bus efficiency, ratio of data transfer rate through bus load (in percent); avarage value over all devices on this PCI bus; optimum value is 100 percent (0x…
1.3.6.1.4.1.231.2.10.2.2.5.4.14ScalarsniScBiosVersionStringread-onlymandatoryString containing complete BIOS version, e.g. V4.05 R1.03.887
1.3.6.1.4.1.231.2.10.2.2.5.4.15ScalarsniScNumberCpuSocketsread-onlymandatoryNumber of CPU sockets available on the system board. This is not the number of currently installed CPUs! This object also describes the number of entries in th…
1.3.6.1.4.1.231.2.10.2.2.5.4.16ScalarsniScNumberMemoryModulesread-onlymandatoryNumber of memory module sockets available on the system board (or memory extension board). This is not the number of currently installed memory modules! This o…
1.3.6.1.4.1.231.2.10.2.2.5.4.17ScalarsniScNumberPciBussesread-onlymandatoryNumber of PCI busses available in the system (-1 = unknown).
1.3.6.1.4.1.231.2.10.2.2.5.4.18ScalartotalMemoryUsageread-onlymandatoryTotal system memory usage (virtual and physical, in KBytes, -1 = unknown)
1.3.6.1.4.1.231.2.10.2.2.5.4.19ScalartotalMemoryUsagePercentread-onlymandatoryTotal system memory usage (virtual and physical, in percent, -1 = unknown)
1.3.6.1.4.1.231.2.10.2.2.5.4.20ScalarphysicalMemoryUsageread-onlymandatoryPhysical system memory usage (in KBytes, -1 = unknown)
1.3.6.1.4.1.231.2.10.2.2.5.4.21ScalarphysicalMemoryUsagePercentread-onlymandatoryPhysical system memory usage (in percent, -1 = unknown)
1.3.6.1.4.1.231.2.10.2.2.5.4.22ScalartotalMemoryAvailableread-onlymandatoryTotal system memory available (virtual and physical, in KBytes, -1 = unknown)
1.3.6.1.4.1.231.2.10.2.2.5.4.23ScalarphysicalMemoryAvailableread-onlymandatoryPhysical system memory available (in KBytes, -1 = unknown)
1.3.6.1.4.1.231.2.10.2.2.5.4.24ScalarphysicalMemoryOsSizeread-onlymandatoryTotal size of the whole physical memory available to the operating system; this value is similar to 'physicalMemorySize', but may be less if the system has mir…
1.3.6.1.4.1.231.2.10.2.2.5.5NodepagerSetup
1.3.6.1.4.1.231.2.10.2.2.5.5.1TablepagerUserTablenot-accessiblemandatoryTable with info of the users that should be paged
1.3.6.1.4.1.231.2.10.2.2.5.5.1.1RowpagerUsernot-accessiblemandatory
1.3.6.1.4.1.231.2.10.2.2.5.5.1.1.1ColumnpagerUserIndexread-onlymandatoryIndex into pager user table (0 based)
1.3.6.1.4.1.231.2.10.2.2.5.5.1.1.2ColumnpagerTyperead-writemandatoryType of the installed pager (signal, numeric, alfa-numeric). The value unknown(1) and not-available(2) cannot be set, a SET will deliver 'badValue'.
1.3.6.1.4.1.231.2.10.2.2.5.5.1.1.3ColumnpagerUserNameread-writemandatoryName of the pager user
1.3.6.1.4.1.231.2.10.2.2.5.5.1.1.4ColumnpagerUserDescriptionread-writemandatoryDescription (function, optional) of the pager user
1.3.6.1.4.1.231.2.10.2.2.5.5.1.1.5ColumnpagerActiveread-writemandatoryDescribes whether this pager is active and should be called. The value unknown(1) cannot be set, a SET will deliver 'badValue'.
1.3.6.1.4.1.231.2.10.2.2.5.5.1.1.6ColumnpagerNumberread-writemandatoryUser ID number of the user's pager
1.3.6.1.4.1.231.2.10.2.2.5.5.1.1.7ColumnpagerServiceProviderNumberread-writemandatoryTelephone dial number of the pager service provider (can also contain additional modem dial characters)
1.3.6.1.4.1.231.2.10.2.2.5.5.1.1.8ColumnpagerActivityPromptread-writemandatoryPrompt string that should be received before pager number can be sent
1.3.6.1.4.1.231.2.10.2.2.5.5.1.1.9ColumnpagerTimeModelread-writemandatoryEncoded string containing a pager time model (when should which user be paged); this value is currently not used.
1.3.6.1.4.1.231.2.10.2.2.5.5.2ScalarpagerInitStringread-onlymandatoryInit string that will be sent to the pager modem before the dialing begins
1.3.6.1.4.1.231.2.10.2.2.5.5.3ScalarpagerServerNumberread-writemandatoryNumber of this server. It is sent together with the error number as a message to the user's pager (-1 = unknown). The value unknown(-1) cannot be set, a SET wi…
1.3.6.1.4.1.231.2.10.2.2.5.5.4ScalarpagerComPortread-writemandatoryCOM port number (1...4) the pager modem is connected to. The value unknown(1) cannot be set, a SET will deliver 'badValue'.
1.3.6.1.4.1.231.2.10.2.2.5.5.5ScalarpagerComPortBaudRateread-writemandatoryBaud rate of the pager COM port. Following values are supported: 1200, 2400, 4800, 9600, 19200 (-1 = unknown). The value unknown(-1) cannot be set, a SET will …
1.3.6.1.4.1.231.2.10.2.2.5.5.6ScalarpagerComPortParityread-writemandatoryParity check configuration for the pager COM port. The value unknown(1) cannot be set, a SET will deliver 'badValue'.
1.3.6.1.4.1.231.2.10.2.2.5.5.7ScalarpagerComPortNumBitsread-writemandatoryNumber of bits per byte on the pager COM port (7, 8, -1 = unknown). The value unknown(-1) cannot be set, a SET will deliver 'badValue'.
1.3.6.1.4.1.231.2.10.2.2.5.5.8ScalarpagerComPortFlowControlread-writemandatoryFlow control method of the pager COM port (Hardware, XON/XOFF...). The value unknown(1) cannot be set, a SET will deliver 'badValue'.
1.3.6.1.4.1.231.2.10.2.2.5.5.9ScalarpagerModemNameread-writemandatoryOptional modem name or type; can be used just as info to be displayed.
1.3.6.1.4.1.231.2.10.2.2.5.7NodestandardBiosSetup
1.3.6.1.4.1.231.2.10.2.2.5.7.1ScalarstdSetupPasswordEnableread-onlymandatoryTells whether a password is configured for the standard BIOS (read-only)
1.3.6.1.4.1.231.2.10.2.2.5.7.2ScalarstdSetupBootSourceread-writemandatorySource medium to boot from: Normal system or diagnostic system standard(2): standard boot diag-system(4): boot from alternate diagnostic system The source the …
1.3.6.1.4.1.231.2.10.2.2.5.7.3ScalarstdSetupPostErrorHaltread-writemandatoryDescribes what to do when a POST error has occured (halt on any error, no halt on any error...). The values unknown(1) and other(9) cannot be set, a SET will d…
1.3.6.1.4.1.231.2.10.2.2.5.7.4ScalarstdSetupSerialInterface1read-writemandatoryThe COM port which the on-board serial interface 1 is mapped to (1...4). The value unknown(1) cannot be set, a SET will deliver 'badValue'.
1.3.6.1.4.1.231.2.10.2.2.5.7.5ScalarstdSetupSerialInterface2read-writemandatoryThe COM port which the on-board serial interface 2 is mapped to (1...4). The value unknown(1) cannot be set, a SET will deliver 'badValue'.
1.3.6.1.4.1.231.2.10.2.2.5.7.6ScalarstdSetupParallelInterfaceread-writemandatoryThe LPT port which the on-board parallel interface is mapped to (1...3). The value unknown(1) cannot be set, a SET will deliver 'badValue'.
1.3.6.1.4.1.231.2.10.2.2.5.7.7ScalarstdSetupFloppyControllerread-writemandatoryDescribes whether the floppy controller is enabled. The value unknown(1) cannot be set, a SET will deliver 'badValue'.
1.3.6.1.4.1.231.2.10.2.2.5.7.8ScalarstdSetupHarddiskControllerread-writemandatoryDescribes whether the IDE harddisk controller is enabled. The value unknown(1) cannot be set, a SET will deliver 'badValue'.
1.3.6.1.4.1.231.2.10.2.2.5.7.9ScalarstdSetupMouseControllerread-writemandatoryDescribes whether the mouse port controller is enabled. The value unknown(1) cannot be set, a SET will deliver 'badValue'.
1.3.6.1.4.1.231.2.10.2.2.5.8NodeserverBiosSetup
1.3.6.1.4.1.231.2.10.2.2.5.8.1ScalarsrvSetupCabinetIdread-writemandatoryCabinet ID number of this server (-1 = unknown). The value unknown(-1) cannot be set, a SET will deliver 'badValue'. Use this number as cabinetId for all table…
1.3.6.1.4.1.231.2.10.2.2.5.8.2ScalarsrvSetupServerRackSlotread-writeoptionalSlot number (in a rack) this server is in (only for rack servers; -1 = unknown). The value unknown(-1) cannot be set, a SET will deliver 'badValue'. This objec…
1.3.6.1.4.1.231.2.10.2.2.5.8.3ScalarsrvSetupServerGroupStartread-writeobsoletedeleted
1.3.6.1.4.1.231.2.10.2.2.5.8.4ScalarsrvSetupServerGroupEndread-writeobsoletedeleted
1.3.6.1.4.1.231.2.10.2.2.5.8.5ScalarsrvSetupServerGroupMembersread-writeobsoletedeleted
1.3.6.1.4.1.231.2.10.2.2.5.8.6ScalarsrvSetupSeGroupStartread-writeobsoletedeleted
1.3.6.1.4.1.231.2.10.2.2.5.8.7ScalarsrvSetupSeGroupEndread-writeobsoletedeleted
1.3.6.1.4.1.231.2.10.2.2.5.8.8ScalarsrvSetupSeGroupMembersread-writeobsoletedeleted
1.3.6.1.4.1.231.2.10.2.2.5.8.9ScalarsrvSetupRemoteOnEnableread-writemandatoryDescribes whether remote-on via RI modem line is enabled or not available. The value unknown(1) cannot be set, a SET will deliver 'badValue'.
1.3.6.1.4.1.231.2.10.2.2.5.8.10ScalarsrvSetupMaxRestartRetriesread-writemandatoryMaximum number of retries to reboot/restart the server when a shutdown (and power-off) had occured. After this number of retries the action defined in 'srvSetu…
1.3.6.1.4.1.231.2.10.2.2.5.8.11ScalarsrvSetupRebootFailActionread-writemandatoryDescribes the action on a specified number of failed reboot retries (srvSetupMaxRestartRetries=0): unknown(1) - diagnostic system cannot be determined (cannot …
1.3.6.1.4.1.231.2.10.2.2.5.8.12ScalarsrvSetupRebootFailPagerread-writemandatoryDescribes whether the pager should be activated when reboot after error shutdown had occured. The value unknown(1) cannot be set, a SET will deliver 'badValue'.
1.3.6.1.4.1.231.2.10.2.2.5.8.13ScalarsrvSetupSeGroupNumberread-writemandatoryGroup number for storage extension communication bus. Legal values are 0..9, -1 = unknown. The value unknown(-1) cannot be set, a SET will deliver 'badValue'.
1.3.6.1.4.1.231.2.10.2.2.5.8.14ScalarsrvSetupRestartRetriesDefaultread-writemandatoryDefault number of retries to reboot/restart the server when a shutdown (and power-off) had occured. This value will be copied to object srvSetupMaxRestartRetri…
1.3.6.1.4.1.231.2.10.2.2.5.9NodepowerOnOff
1.3.6.1.4.1.231.2.10.2.2.5.9.1TableonOffTimesTablenot-accessiblemandatoryTable with system power on/off times; power-on will be performed by the real-time clock, power-off (with shutdown) by the operating system (system control serv…
1.3.6.1.4.1.231.2.10.2.2.5.9.1.1RowonOffTimesnot-accessiblemandatory
1.3.6.1.4.1.231.2.10.2.2.5.9.1.1.1ColumnonOffWeekdayread-onlymandatoryDay of the week the times should act upon (index, 1 based); 1 = Sunday, 2 = Monday...
1.3.6.1.4.1.231.2.10.2.2.5.9.1.1.2ColumnonTimeread-writemandatoryTime the system should be switched on (by the real-time clock; in minutes since midnight; -1 = disabled, no on time). Only values -1 and 0..1439 are allowed.
1.3.6.1.4.1.231.2.10.2.2.5.9.1.1.3ColumnoffTimeread-writemandatoryTime the system should be switched off (by the operating system; in minutes since midnight; -1 = disabled, no off time). Only values -1 and 0..1439 are allowed.
1.3.6.1.4.1.231.2.10.2.2.5.9.2ScalarshutdownDelayTimeread-writemandatoryThe delay time (in minutes) the agent should wait before executing a shutdown (with doShutdown); 0 = default = shutdown immediately; -1 = unknown. The value un…
1.3.6.1.4.1.231.2.10.2.2.5.9.3ScalardoShutdownread-writemandatoryExecute a shutdown; argument tells what kind of shutdown: shutdown: wait for user to switch off or reboot shutdown-and-off: switch off after shutdown shutdown-…
1.3.6.1.4.1.231.2.10.2.2.5.9.4ScalarpowerOnCountsread-onlymandatoryTells how often the server was switched on in its life (-1 = unknown)
1.3.6.1.4.1.231.2.10.2.2.5.9.5ScalarpowerOnDurationHoursread-onlymandatoryTells how long the system was switched on in its life (in hours; -1 = unknown)
1.3.6.1.4.1.231.2.10.2.2.5.9.6ScalarpowerOffDurationHoursread-onlymandatoryTells how long the system was switched off in its life (in hours; -1 = unknown)
1.3.6.1.4.1.231.2.10.2.2.5.9.7ScalarerrorOffRestartDelayread-writemandatoryDelay (in minutes) when the system should be automatically switched on again (by real-time clock) after an error power-off (-1 = no switch-on function). The va…
1.3.6.1.4.1.231.2.10.2.2.5.9.8ScalarlastPostStatusread-onlyobsoleteDescribes whether the last (current) POST (power on self test) was errornous. Object is now obsolete - use object systemBootStatus instead!
1.3.6.1.4.1.231.2.10.2.2.5.9.9ScalarlastPowerOffSourceread-onlymandatoryReason why the system was switched off last time
1.3.6.1.4.1.231.2.10.2.2.5.9.10ScalarlastPowerOnSourceread-onlymandatorySource the system was switched on from
1.3.6.1.4.1.231.2.10.2.2.5.9.11ScalarpowerOnTimeread-onlymandatoryTime and Date the system was booted (seconds since 1/1/1970; -1 = unknown)
1.3.6.1.4.1.231.2.10.2.2.5.9.12ScalardoPowerOnOffread-writemandatorySwitch the server on or off; argument tells what kind of action: on: switch power on off: switch power off power-cycle: switch power off and switch power on ag…
1.3.6.1.4.1.231.2.10.2.2.5.9.13ScalarsystemBootResultread-onlymandatoryResult of the last server boot.
1.3.6.1.4.1.231.2.10.2.2.5.9.14ScalarsystemBootStatusread-onlymandatoryStatus of the current boot process.
1.3.6.1.4.1.231.2.10.2.2.5.10NodesystemControlInfo
1.3.6.1.4.1.231.2.10.2.2.5.10.1ScalarnumberCabinetsConfiguredread-onlymandatoryNumber of configured cabinets (server and storage extensions, at least 1: the server itself)
1.3.6.1.4.1.231.2.10.2.2.5.10.2ScalarnumberCabinetsDetectedread-onlymandatoryNumber of detected cabinets (server and storage extensions, at least 1: the server itself). This is also the number of entries in cabinetInfosTable.
1.3.6.1.4.1.231.2.10.2.2.5.10.3TablecabinetInfosTablenot-accessiblemandatoryTable with data of all configured cabinets
1.3.6.1.4.1.231.2.10.2.2.5.10.3.1RowcabinetInfosnot-accessiblemandatory
1.3.6.1.4.1.231.2.10.2.2.5.10.3.1.1ColumncabinetIdread-onlymandatoryCabinet ID number, index into the cabinet table
1.3.6.1.4.1.231.2.10.2.2.5.10.3.1.2ColumncabinetLocationread-writemandatoryThe place where the cabinet is located (user can store any string here to identify the cabinet location)
1.3.6.1.4.1.231.2.10.2.2.5.10.3.1.3ColumncabinetIdentNumberread-writemandatorySystem ident number (serial number) - will be a number like 'XYZZ 12345678'. XYZZ is the cabinet identifier and is mandatory. It will be used to identify the c…
1.3.6.1.4.1.231.2.10.2.2.5.10.3.1.4ColumncabinetSystemNameread-onlymandatorySystem name string (i.e. PCD-5S, Primergy 150...)
1.3.6.1.4.1.231.2.10.2.2.5.10.3.1.5ColumncabinetNumberFansread-onlymandatoryThe number of configured cooling devices (fans) in this cabinet (-1 = unknown)
1.3.6.1.4.1.231.2.10.2.2.5.10.3.1.6ColumncabinetNumberTempSensorsread-onlymandatoryThe number of configured temperature sensors in this cabinet (-1 = unknown)
1.3.6.1.4.1.231.2.10.2.2.5.10.3.1.7ColumncabinetNumberPowerSuppliesread-onlymandatoryThe number of available power supplies in this cabinet (-1 = unknown)
1.3.6.1.4.1.231.2.10.2.2.5.10.3.1.8ColumncabinetPowerSupplySlotsread-onlymandatoryThe number of power supply slots in this cabinet (is the maximum number of installable power supplies; 0 if no hot-plug slots available; -1 = unknown)
1.3.6.1.4.1.231.2.10.2.2.5.10.3.1.9ColumncabinetUpsUsedread-onlymandatoryUninterruptable power supply for this cabinet available: 0: No UPS 1..n: Index in UPS table -1: unknown
1.3.6.1.4.1.231.2.10.2.2.5.10.3.1.10ColumncabinetBoardSerialNumberread-onlymandatorySerial number of the cabinet's system board
1.3.6.1.4.1.231.2.10.2.2.5.10.3.1.11ColumncabinetBoardRevisionread-onlyobsoleteRevision (GS) of the cabinet's system board (-1 = unknown). Value obsolete, use sieScCabinetBoardRevisionString instead!
1.3.6.1.4.1.231.2.10.2.2.5.10.3.1.12ColumncabinetBoardIdread-onlymandatoryIdentifier string of the cabinet's system board
1.3.6.1.4.1.231.2.10.2.2.5.10.3.1.13ColumncabinetManagementControllerTyperead-onlymandatoryType of the cabinet's system management controller (i.e. SNI System Control Board)
1.3.6.1.4.1.231.2.10.2.2.5.10.3.1.14ColumncabinetControllerFirmwareMajorread-onlymandatoryFirmware version (major number) of the cabinet's system management controller (-1 = unknown). This object will be replaced by sieScCabinetControllerFirmware in…
1.3.6.1.4.1.231.2.10.2.2.5.10.3.1.15ColumncabinetControllerFirmwareMinorread-onlymandatoryFirmware version (minor number) of the cabinet's system management controller (-1 = unknown). This object will be replaced by sieScCabinetControllerFirmware in…
1.3.6.1.4.1.231.2.10.2.2.5.10.3.1.16ColumncabinetAttributeread-onlymandatoryAttribute of a cabinet (Primary/secondary server, storage extension...)
1.3.6.1.4.1.231.2.10.2.2.5.10.3.1.17ColumncabinetPowerOnStatusread-onlymandatoryPower-on state of the cabinet
1.3.6.1.4.1.231.2.10.2.2.5.10.3.1.18ColumncabinetStatusSummaryread-onlymandatoryDescribes the status of a cabinet (OK, degraded, error...)
1.3.6.1.4.1.231.2.10.2.2.5.10.3.1.19ColumncabinetLastPoweroffSourceread-onlymandatoryThe source from which the cabinet was powered off last time
1.3.6.1.4.1.231.2.10.2.2.5.10.3.1.20ColumncabinetActionAfterAcFailread-writemandatoryAction on AC power resume after AC has failed. not-available(2) : function not available, behavior is hardware-defined. as-before(3) : server gets the same pow…
1.3.6.1.4.1.231.2.10.2.2.5.10.3.1.21ColumncabinetBbuUsedread-onlymandatoryBattery buffering unit for this cabinet available. The value unknown(1) cannot be set, a SET will deliver 'badValue'.
1.3.6.1.4.1.231.2.10.2.2.5.10.3.1.22ColumncabinetSystemTyperead-onlyobsoleteValue is obsolete. This value should no longer be used for cabinet identification. Use cabinetHousingType to identify the housing type and cabinetSystemName fo…
1.3.6.1.4.1.231.2.10.2.2.5.10.3.1.23ColumncabinetStatusDetailread-onlymandatoryMore detailed status information from this cabinet. The StatusDetail object is set to reflect the new status. ok: (status ok) no failures detected. selftestWar…
1.3.6.1.4.1.231.2.10.2.2.5.10.3.1.24ColumncabinetHousingTyperead-onlymandatoryType string for cabinet housing type (i.e. 'P300' for all PRIMERGY 3xx housings); this object should be used to identify the cabinet instead of using object ca…
1.3.6.1.4.1.231.2.10.2.2.5.10.3.1.25ColumncabinetFrontDoorStatusread-onlymandatoryStatus of the cabinet's front door
1.3.6.1.4.1.231.2.10.2.2.5.10.3.1.26ColumncabinetHousingOpenStatusread-onlymandatoryStatus describing whether the housing is open or closed
1.3.6.1.4.1.231.2.10.2.2.5.10.3.1.27ColumnsieScCabinetNumberVoltagesread-onlymandatoryNumber of entries in power supply voltage table
1.3.6.1.4.1.231.2.10.2.2.5.10.3.1.28ColumnsieScCabinetControllerFirmwareread-onlymandatoryThe cabinet's system management controller firmware version (i.e. '1.1.4.88'). This object will replace the previous objects cabinetControllerFirmwareMinor and…
1.3.6.1.4.1.231.2.10.2.2.5.10.3.1.29ColumnsieScCabinetBoardRevisionStringread-onlymandatoryRevision string (GS, WGS...) of the cabinet's system board. This object replaces the previous object cabinetBoardRevision.
1.3.6.1.4.1.231.2.10.2.2.5.10.3.1.30ColumnsieScCabinetAdministrativeURLread-onlymandatoryProvides a URL that may be used by a front-end to start a web browser and connect it directly to the cabinet's administrative web server (e.g. https://10.0.0.2…
1.3.6.1.4.1.231.2.10.2.2.5.10.3.1.31ColumnsieScRemcsIdread-onlymandatoryREMCS system identification string (binary data): Format of Fujitsu REMCS ID (40byte) Format = TTMMMMMMMMMMMMmmmmmmmmmmmmCCnnnnnnnnnnnn TT : 2byte : Type ID fo…
1.3.6.1.4.1.231.2.10.2.2.5.10.4ScalarstatusSummaryread-onlyobsoleteValue is obsolete
1.3.6.1.4.1.231.2.10.2.2.5.10.5ScalarserverTyperead-onlyobsoleteValue is obsolete. This value should no longer be used for server identification. Use serverHousingType to identify the housing type and cabinetSystemName for …
1.3.6.1.4.1.231.2.10.2.2.5.10.6ScalarserverHousingTyperead-onlymandatoryType string for cabinet housing type (i.e. 'P300' for all PRIMERGY 3xx housings); this object should be used to identify the cabinet instead of using object se…
1.3.6.1.4.1.231.2.10.2.2.5.10.7ScalarserverUUIDread-onlymandatoryUniversal Unique ID (UUID) number - this is a world wide unique ID number of the server. Can be used for identifying a server. This UUID is formatted as specif…
1.3.6.1.4.1.231.2.10.2.2.5.11NodepowerSupply
1.3.6.1.4.1.231.2.10.2.2.5.11.1TablepowerSuppliesTablenot-accessiblemandatoryTable with power supply groups in the cabinets
1.3.6.1.4.1.231.2.10.2.2.5.11.1.1RowpowerSuppliesnot-accessiblemandatory
1.3.6.1.4.1.231.2.10.2.2.5.11.1.1.1ColumnpowerSupplyCabinetIdread-onlymandatoryCabinet ID, index into the power supply table (0 based)
1.3.6.1.4.1.231.2.10.2.2.5.11.1.1.2ColumnpowerSupplyStatusread-onlymandatoryStatus of the cabinet's power supply group; ok: all units OK, number >= minimum degraded: one or more units failed, number OK >= minimum critical: number OK < …
1.3.6.1.4.1.231.2.10.2.2.5.11.1.1.3ColumnpowerSupplyRedundancyread-onlymandatoryNumber of available redundant power supply units (i.e. 2 units minimum, 3 available -> redundancy is 1, -1 = unknown)
1.3.6.1.4.1.231.2.10.2.2.5.11.2TablepowerSupplyUnitsTablenot-accessiblemandatoryTable with info about the configured power supply units
1.3.6.1.4.1.231.2.10.2.2.5.11.2.1RowpowerSupplyUnitsnot-accessiblemandatory
1.3.6.1.4.1.231.2.10.2.2.5.11.2.1.1ColumnpowerSupplyUnitCabinetIdread-onlymandatoryCabinet ID, index into the power supply unit table (0 based)
1.3.6.1.4.1.231.2.10.2.2.5.11.2.1.2ColumnpowerSupplyUnitNumberread-onlymandatoryPower supply unit number, index into power supply unit table (0 based)
1.3.6.1.4.1.231.2.10.2.2.5.11.2.1.3ColumnpowerSupplyUnitStatusread-onlymandatoryStatus of the power supply unit (OK, failed, not present...)
1.3.6.1.4.1.231.2.10.2.2.5.11.2.1.4ColumnpowerSupplyUnitDesignationread-onlymandatoryPower supply unit designation. This string specifies a name/designation for the power supply unit. The designation string may not be available on some platform…
1.3.6.1.4.1.231.2.10.2.2.5.11.4TablesniScVoltageTablenot-accessiblemandatoryTable with power supply voltage information
1.3.6.1.4.1.231.2.10.2.2.5.11.4.1RowsniScVoltagesnot-accessiblemandatory
1.3.6.1.4.1.231.2.10.2.2.5.11.4.1.1ColumnsniScVoltageCabinetNumberread-onlymandatoryCabinet number, index into the power supply voltage table (0 based)
1.3.6.1.4.1.231.2.10.2.2.5.11.4.1.2ColumnsniScVoltageNumberread-onlymandatoryPower supply voltage number, index into power supply voltage table (0 based)
1.3.6.1.4.1.231.2.10.2.2.5.11.4.1.3ColumnsniScVoltageStatusread-onlymandatoryStatus of the power supply voltage; 'not-available' maybe the voltage of an empty CPU socket; 'out-of-range' comes when the voltage is out of range; 'prefailur…
1.3.6.1.4.1.231.2.10.2.2.5.11.4.1.4ColumnsniScVoltageDesignationread-onlymandatoryPower supply voltage designation. This string specifies the voltage by clear text (e.g. 5V, 12V, 3.3V...)
1.3.6.1.4.1.231.2.10.2.2.5.11.4.1.5ColumnsniScVoltageMinimumValueread-onlymandatoryPower supply voltage minimum level (1/100th Volts; -1 = unknown)
1.3.6.1.4.1.231.2.10.2.2.5.11.4.1.6ColumnsniScVoltageMaximumValueread-onlymandatoryPower supply voltage maximum level (1/100th Volts; -1 = unknown)
1.3.6.1.4.1.231.2.10.2.2.5.11.4.1.7ColumnsniScVoltageCurrentValueread-onlymandatoryPower supply voltage current level, negative voltages are reported as negative values (1/100th Volts, e.g. 330 means 3.30 Volts; -177 (0xFFFFFF4F) means -1.77 …
1.3.6.1.4.1.231.2.10.2.2.5.11.4.1.8ColumnsniScVoltageNominalValueread-onlymandatoryPower supply voltage nominal level (1/100th Volts; -1 = unknown)
1.3.6.1.4.1.231.2.10.2.2.5.11.4.1.9ColumnsniScVoltageOutputLoadread-onlymandatoryPower supply output load in percent of maximum load; 0xFFFFFFFF = unknown
1.3.6.1.4.1.231.2.10.2.2.5.12NodeuninterruptablePowerSupply
1.3.6.1.4.1.231.2.10.2.2.5.12.1ScalarupsCountread-onlymandatoryNumber of uninterruptable power supplies (UPS) in this system (-1 = unknown)
1.3.6.1.4.1.231.2.10.2.2.5.12.2TableupsInfosTablenot-accessiblemandatoryTable with uninterruptable power supplies used in this system. The index is the UPS number used in the system. One or more server or storage-extension objects …
1.3.6.1.4.1.231.2.10.2.2.5.12.2.1RowupsInfosnot-accessiblemandatory
1.3.6.1.4.1.231.2.10.2.2.5.12.2.1.1ColumnupsNumberread-onlymandatoryNumber of the UPS in this table (index, 1 based)
1.3.6.1.4.1.231.2.10.2.2.5.12.2.1.2ColumnupsDetectedread-onlymandatoryTells whether the UPS was detected
1.3.6.1.4.1.231.2.10.2.2.5.12.2.1.3ColumnupsDischargeTimeread-onlymandatoryMaximum time this UPS will be discharged, after that a shutdown will be performed (seconds; -1 = unknown)
1.3.6.1.4.1.231.2.10.2.2.5.12.2.1.4ColumnupsVendorread-onlymandatoryVendor name of the UPS
1.3.6.1.4.1.231.2.10.2.2.5.12.2.1.5ColumnupsTyperead-onlymandatoryType of the UPS; can be used to identify an OEM UPS with an OEM agent
1.3.6.1.4.1.231.2.10.2.2.5.12.2.1.6ColumnupsOemAgentread-onlymandatoryObject identifier of an OEM UPS MIB; no agent if empty OID
1.3.6.1.4.1.231.2.10.2.2.5.12.2.1.7ColumnupsOemAgentAddressread-onlymandatoryIP address of an OEM UPS SNMP agent; no agent if empty
1.3.6.1.4.1.231.2.10.2.2.5.12.2.1.8ColumnupsTimeOnBatterySecondsread-onlymandatoryTime (in seconds) the UPS is running on battery since power fail (will be cleared on power recovery)
1.3.6.1.4.1.231.2.10.2.2.5.12.3ScalarspbbuStatusread-onlyoptionalStatus of the service processor's backup battery (not present, OK, recharging)
1.3.6.1.4.1.231.2.10.2.2.5.12.4ScalarspbbuDischargeTimeread-onlyoptionalMaximum time this backup battery will be discharged, after that a shutdown will be performed (seconds; -1 = unknown)
1.3.6.1.4.1.231.2.10.2.2.5.12.5ScalarspbbuTimeOnBatterySecondsread-onlyoptionalTime (in seconds) the backup battery is running on battery since power fail (will be cleared on power recovery)
1.3.6.1.4.1.231.2.10.2.2.5.12.6ScalarspbbuDoChargeCycleread-writeoptionalPerform a discharge/charge cycle on the backup battery. Reading this object just returns the value 0.
1.3.6.1.4.1.231.2.10.2.2.5.12.7ScalarspbbuChargeStatusread-onlyoptionalReads the current charge level of the rechargeable battery (in percent of the maximum capacity).
1.3.6.1.4.1.231.2.10.2.2.5.13Nodediagnostics
1.3.6.1.4.1.231.2.10.2.2.5.13.1ScalarsendTestTrapread-writemandatorySend a trap to the manager application(s) to test connection and trap configuration; trap cannot be disabled. Reading this object just returns the value 0.
1.3.6.1.4.1.231.2.10.2.2.5.14Nodemanagement
1.3.6.1.4.1.231.2.10.2.2.5.14.1TableinterfaceParametersTablenot-accessiblemandatoryTable with the interface parameters of all management channels, which are controlled by this server.
1.3.6.1.4.1.231.2.10.2.2.5.14.1.1RowinterfaceParametersnot-accessiblemandatoryThe interface parameters of the designated management channel interface.
1.3.6.1.4.1.231.2.10.2.2.5.14.1.1.1ColumninterfaceCabinetIdread-onlymandatoryCabinetId of the cabinet where the management channel interface resides.
1.3.6.1.4.1.231.2.10.2.2.5.14.1.1.2ColumninterfaceNumberread-onlymandatoryIndex number of the channel management interface (index, 0 based).
1.3.6.1.4.1.231.2.10.2.2.5.14.1.1.3ColumninterfaceTyperead-onlymandatoryThe interface type of the interface.
1.3.6.1.4.1.231.2.10.2.2.5.14.1.1.4ColumnipAddressread-onlymandatoryThe IP v4 address of the interface.
1.3.6.1.4.1.231.2.10.2.2.5.14.1.1.5ColumnipAdressNetMaskread-onlymandatoryThe IP v4 subnet mask of the interface.
1.3.6.1.4.1.231.2.10.2.2.5.14.1.1.6ColumnphysicalAddressread-onlymandatoryThe interface address of the physical layer of the interface (MAC address).
1.3.6.1.4.1.231.2.10.2.2.5.14.1.1.7ColumnphoneNumberread-onlymandatoryThe telephone dial number of this interface. Only useful if the interfaceType is of type dial-up(3).
1.3.6.1.4.1.231.2.10.2.2.5.14.1.1.8ColumninterfaceChannelTyperead-onlymandatoryThe managegement channel type of the interface: primary: local operating system interface secondary: local management controller LAN interface management-blade…
1.3.6.1.4.1.231.2.10.2.2.5.14.1.1.9ColumndhcpConfiguredread-onlymandatoryDefines if the ip address should be requested by a dhcp service.
1.3.6.1.4.1.231.2.10.2.2.5.14.1.1.10ColumncontrollerTyperead-onlymandatoryThe type of the remote or baseboard management controller (for identification), like 'RSB', 'RSB S2', 'RSB S2 LP'... These names will not be changed if defined…
1.3.6.1.4.1.231.2.10.2.2.5.14.1.1.11ColumncontrollerModelread-onlymandatoryThe model name of the remote management controller (for displaying), like 'Remote Service Board', 'RemoteView Service Board S2'... This name should not be used…
1.3.6.1.4.1.231.2.10.2.2.5.14.1.1.12ColumncontrollerFWVersionread-onlymandatoryThe FW version of the remote or baseboard management controller as string;
1.3.6.1.4.1.231.2.10.2.2.5.14.2TableserviceComponentsTablenot-accessiblemandatoryTable with the components attached to the service processor
1.3.6.1.4.1.231.2.10.2.2.5.14.2.1RowserviceComponentsnot-accessiblemandatoryThe components attached to the service processor
1.3.6.1.4.1.231.2.10.2.2.5.14.2.1.1ColumnserviceComponentProcessorIdread-onlymandatoryId of the service processor this component is attached to (index, 0 based)
1.3.6.1.4.1.231.2.10.2.2.5.14.2.1.2ColumnserviceComponentIdread-onlymandatoryIndex number of the service component (index, 0 based)
1.3.6.1.4.1.231.2.10.2.2.5.14.2.1.3ColumnserviceComponentNameread-onlymandatoryThe name of the component in human readable form
1.3.6.1.4.1.231.2.10.2.2.5.14.2.1.4ColumnserviceComponentTyperead-onlymandatoryThe type of the componen we are dealing with.
1.3.6.1.4.1.231.2.10.2.2.5.14.2.1.5ColumnserviceComponentStatusread-onlymandatoryDescribes the status of the component managed by the service processor. Degraded means that some problems have occurred. Error that the component has reported …
1.3.6.1.4.1.231.2.10.2.2.5.14.3ScalarchannelTyperead-onlymandatoryThe managegement channel type of the currently used management channel.
1.3.6.1.4.1.231.2.10.2.2.5.20NodetrapInfo
1.3.6.1.4.1.231.2.10.2.2.5.20.1ScalartrapServerNamenot-accessiblemandatoryName of server the trap occured
1.3.6.1.4.1.231.2.10.2.2.5.20.2ScalartrapTimenot-accessiblemandatoryTime the trap occured (in seconds since 01/01/1970 00:00h)
1.3.6.1.4.1.231.2.10.2.2.5.20.3ScalartrapCabinetNumbernot-accessiblemandatoryNumber of the cabinet where the trap was generated
1.3.6.1.4.1.231.2.10.2.2.5.20.4ScalartrapObjectNumbernot-accessiblemandatoryNumber of the object that generated the trap (fan, temperature sensor...)
1.3.6.1.4.1.231.2.10.2.2.5.20.5ScalartrapStringnot-accessiblemandatoryAdditional string to be displayed in the trap text
1.3.6.1.4.1.231.2.10.2.2.5.20.6ScalartrapMinutesRemainingnot-accessiblemandatoryThe estimated remaining BBU/UPS capacity in minutes. In the current implementation this is the time remaining until the system will shut down.
1.3.6.1.4.1.231.2.10.2.2.5.20.7ScalartrapSecondsOnBatterynot-accessiblemandatorySee scbUPSSecondsOnBattery/scbBBUSecondsOnBattery.
1.3.6.1.4.1.231.2.10.2.2.5.20.8ScalartrapConfigLowBattTimenot-accessiblemandatoryThe value of trapMinutesRemaining at which a shut down is initiated. In the current implementation this is always 0.
1.3.6.1.4.1.231.2.10.2.2.5.20.9ScalartrapNumValuenot-accessiblemandatoryAdditional numeric value to be displayed in the trap text
1.3.6.1.4.1.231.2.10.2.2.5.20.10ScalartrapManagementInterfaceNumbernot-accessiblemandatoryThe number of the management channel interface.
1.3.6.1.4.1.231.2.10.2.3NodesniPcSpecific
1.3.6.1.4.1.231.2.10.2.4NodesniScb
1.3.6.1.4.1.231.2.10.2.5NodesniOsSpecific
1.3.6.1.4.1.231.2.10.2.5.1NodesniNetware
1.3.6.1.4.1.231.2.10.2.5.2NodesniWinNt
1.3.6.1.4.1.231.2.10.2.5.3NodesniOs2
1.3.6.1.4.1.231.2.10.2.5.4NodesniUnix
1.3.6.1.4.1.231.2.10.2.6NodesniOemComponents
1.3.6.1.4.1.231.2.10.2.6.1NodesniOemDpt
1.3.6.1.4.1.231.2.10.2.6.2NodesniOemMylex
1.3.6.1.4.1.231.2.10.2.6.2.1NodesniMlxDiskArray
1.3.6.1.4.1.231.2.10.2.7NodesniSecurity
1.3.6.1.4.1.231.2.10.2.7.1NodesniSmSecurity
1.3.6.1.4.1.231.2.10.2.8NodesniServerView
1.3.6.1.4.1.231.2.10.2.600NodetestTrapTest trap to verify trap connection.
1.3.6.1.4.1.231.2.10.2.601NodefanErrorThe indicated fan failed.
1.3.6.1.4.1.231.2.10.2.602NodetempOkThe temperature of the indicated sensor has decreased to the normal level.
1.3.6.1.4.1.231.2.10.2.603NodetempWarnThe temperature of the indicated sensor has reached the warning level.
1.3.6.1.4.1.231.2.10.2.604NodetempCriticalThe temperature of the indicated sensor is out of tolerance range. The system will shut down and power off if shutdown is enabled.
1.3.6.1.4.1.231.2.10.2.606NodetrapOnBatteryThe UPS is operating on battery power or the power supply is drawing current from the backup battery unit (BBU). This status is persistent and is resent at one…
1.3.6.1.4.1.231.2.10.2.607NodetrapOnMainsThe mains voltage returned after a power failure.
1.3.6.1.4.1.231.2.10.2.608NodeselftestWarningCurrently the only possible warning is: SCB battery (nearly) empty.
1.3.6.1.4.1.231.2.10.2.609NodeselftestErrorThe Server Management controller failed.
1.3.6.1.4.1.231.2.10.2.610NodesvCommunicationFailureCommunication with the Server Management controller lost.
1.3.6.1.4.1.231.2.10.2.611NodescbUnconfiguredUPSDetectedA UPS has been detected, but no UPS is configured. This trap will be repeated every 60 minutes until the condition is removed.
1.3.6.1.4.1.231.2.10.2.612NodescbUPSNotdetectedA UPS is configured, but no UPS has been detected. This trap will be repeated every 60 minutes until the condition is removed.
1.3.6.1.4.1.231.2.10.2.613NodescbUnconfiguredBBUDetectedA BBU has been detected, but no BBU is configured. This trap will be repeated every 60 minutes until the condition is removed.
1.3.6.1.4.1.231.2.10.2.614NodescbBBUNotdetectedA BBU is configured, but no BBU has been detected. This trap will be repeated every 60 minutes until the condition is removed.
1.3.6.1.4.1.231.2.10.2.615NodenotEnoughCabinetsOne or more storage extensions missing.
1.3.6.1.4.1.231.2.10.2.616NodetooManyCabinetsThe actual number of storage extensions is higher than the configured number.
1.3.6.1.4.1.231.2.10.2.617NodecabinetSwitchedOffThe cabinet has been switched off.
1.3.6.1.4.1.231.2.10.2.618NodecabinetSwitchedOnThe cabinet has been switched on.
1.3.6.1.4.1.231.2.10.2.620NodeinternalErrorThe agent has detected an internal error.
1.3.6.1.4.1.231.2.10.2.621NodeserverShutdownThe server is being shut down.
1.3.6.1.4.1.231.2.10.2.622NodefanCriticalErrorThe indicated fan became critical.
1.3.6.1.4.1.231.2.10.2.623NodecabinetNotConfiguredThe agent has detected a mismatch in the configuration of the server.
1.3.6.1.4.1.231.2.10.2.624NodepowerSupplyRemovedOne hot-replace power supply was removed.
1.3.6.1.4.1.231.2.10.2.625NodepowerSupplyAddedOne hot-replace power supply was added.
1.3.6.1.4.1.231.2.10.2.626NodepowerSupplyFailedOne hot-replace power supply failed.
1.3.6.1.4.1.231.2.10.2.627NodepowerSupplyOkPower supply is working again.
1.3.6.1.4.1.231.2.10.2.628NodepowerSupplyStatusCriticalPower supply status has become critical.
1.3.6.1.4.1.231.2.10.2.629NodefanOkThe indicated fan is OK again.
1.3.6.1.4.1.231.2.10.2.630NodetempSensorBrokenThe indicated temperature sensor is broken.
1.3.6.1.4.1.231.2.10.2.631NodeserverManagementDisabledThe server management BIOS is disabled.
1.3.6.1.4.1.231.2.10.2.632NodetrapAcFailMains failed in the specified cabinet. This can only happen in storage extension cabinets without UPS or BBU. A server will not have time to send this event.
1.3.6.1.4.1.231.2.10.2.633NodetrapDuplicateCabinetIdTwo ore more cabinets (server or storage extension) have the same ID number. The system will not run properly.
1.3.6.1.4.1.231.2.10.2.634NodetrapEventLogAn error message was written into the systemboard's event/error log. This could have happened when an error occured before the agent was running or any error w…
1.3.6.1.4.1.231.2.10.2.635NodetempSensorOkThe indicated broken temperature sensor is OK again.
1.3.6.1.4.1.231.2.10.2.636NodesvCommunicationEstablishedCommunication with the Server Management controller established again.
1.3.6.1.4.1.231.2.10.2.637NodecorrectableMemErrorAddrA correctable memory error at specified address was detected.
1.3.6.1.4.1.231.2.10.2.638NodeuncorrectableMemErrorAddrAn uncorrectable memory error at specified address was detected.
1.3.6.1.4.1.231.2.10.2.639NodecorrectableMemErrorBankA correctable memory error at specified bank was detected.
1.3.6.1.4.1.231.2.10.2.640NodeuncorrectableMemErrorBankAn uncorrectable memory error at specified bank was detected.
1.3.6.1.4.1.231.2.10.2.641NodecorrectableMemErrorModuleA correctable memory error at specified module was detected.
1.3.6.1.4.1.231.2.10.2.642NodeuncorrectableMemErrorModuleAn uncorrectable memory error at specified module was detected.
1.3.6.1.4.1.231.2.10.2.643NodecorrectableMemErrorA correctable memory error at unknown address was detected.
1.3.6.1.4.1.231.2.10.2.644NodeuncorrectableMemErrorAn uncorrectable memory error at unknown address was detected.
1.3.6.1.4.1.231.2.10.2.645NodepowerOffTimeReachedThe power-off time is reached! System will shutdown in after delay.
1.3.6.1.4.1.231.2.10.2.646NodefrontDoorStatusChangedThe front door status has changed.
1.3.6.1.4.1.231.2.10.2.647NodehousingOpenStatusChangedThe housing open status has changed
1.3.6.1.4.1.231.2.10.2.648NodesniScRedundantFanFailedThe indicated redundant fan failed.
1.3.6.1.4.1.231.2.10.2.649NodesniScRedundantPowerSupplyFailedOne redundant hot-replace power supply failed.
1.3.6.1.4.1.231.2.10.2.650NodesniScVoltageOkPower supply voltage is within normal range again.
1.3.6.1.4.1.231.2.10.2.651NodesniScVoltageTooLowPower supply voltage is too low.
1.3.6.1.4.1.231.2.10.2.652NodesniScVoltageTooHighPower supply voltage is too high.
1.3.6.1.4.1.231.2.10.2.653NodesniScFanAddedThe indicated hot-plug fan was inserted.
1.3.6.1.4.1.231.2.10.2.654NodesniScFanRemovedThe indicated hot-plug fan was removed.
1.3.6.1.4.1.231.2.10.2.655NodesniScShutdownCancelledThis event will be sent if a pending server shutdown has been cancelled by the user.
1.3.6.1.4.1.231.2.10.2.656NodesniScCpuSpeedChangedThe CPU clock frequency has been reduced because of a temperature problem.
1.3.6.1.4.1.231.2.10.2.657NodesieScPowerOnThe server has been powered on.
1.3.6.1.4.1.231.2.10.2.658NodesieScNoBootCpuThe system boot failed because no valid boot CPU has been found.
1.3.6.1.4.1.231.2.10.2.659NodesieScPostErrorThis trap will be sent when the system boot fails, because the power on selftest (POST) has reported an error.
1.3.6.1.4.1.231.2.10.2.660NodesieScSetupEnteredThis trap will be sent when the bios setup has been entered.
1.3.6.1.4.1.231.2.10.2.661NodesieScBootErrorThis trap will be sent when no bootable operating system can be found.
1.3.6.1.4.1.231.2.10.2.662NodesieScBootWatchdogExpiredThis trap will be sent when the boot watchdog expires.
1.3.6.1.4.1.231.2.10.2.663NodesieScSoftwareWatchdogExpiredThis trap will be sent when the software watchdog expires.
1.3.6.1.4.1.231.2.10.2.664NodesieScUserAuthenticationFailureThis trap will be sent when an user authentication failure is detected via PPP, FTP, HTTP or telnet fails.
1.3.6.1.4.1.231.2.10.2.665NodesieScDiagnosticBootThis trap will be sent when a server is reset and diagnostic boot is enabled. The value in trapString specifies the primary channel i.e. the server name (from …
1.3.6.1.4.1.231.2.10.2.666NodesieScBootRetryCountZeroThis trap will be sent when a boot retry counter gets zero on power up
1.3.6.1.4.1.231.2.10.2.667NodesieScMessageLogFullThe System Event Log is full. No more messages can be logged. This trap will not occur on wrap-around log types.
1.3.6.1.4.1.231.2.10.2.668NodememErrorModulePrefailureA memory module is predicted to fail (prefailure).
1.3.6.1.4.1.231.2.10.2.669NodememErrorModuleFailingA memory module is failing.
1.3.6.1.4.1.231.2.10.2.670NodememErrorModuleReplacedA memory module had failed and was replaced by a hot-spare module.
1.3.6.1.4.1.231.2.10.2.671NodesniScPowerSupplyRedundancyLostPower supply redundancy no longer available.
1.3.6.1.4.1.231.2.10.2.672NodesieScMessageLogWarningThe warning threshold for the number of System Event Log entries has been exceeded.
1.3.6.1.4.1.231.2.10.2.673NodesieScCpuPrefailureA CPU is predicted to fail (prefailure).
1.3.6.1.4.1.231.2.10.2.674NodesieScPowerFailDC power failed in the specified cabinet. This is the result of the system's power-good sensor monitoring. The system may stop when this condition occurs.
1.3.6.1.4.1.231.2.10.2.675NodesieScBiosSelftestErrorA critical error happend while BIOS selftest. This error needs to be acknowledged to clear the error condition.
1.3.6.1.4.1.231.2.10.2.676NodesieScBiosSelftestWatchdogExpiredThis trap will be sent when the BIOS selftest watchdog expires. This watchdog expires when the BIOS selftest cannot be finished in a certain time period.
1.3.6.1.4.1.231.2.10.2.677NodesniScVoltageFailurePower supply voltage is out of range.
1.3.6.1.4.1.231.2.10.2.678NodesniScBatteryVoltagePrefailureBattery is predicted to fail.
1.3.6.1.4.1.231.2.10.2.679NodesieScSevereSystemErrorThe system was restarted after a severe problem. See server management message log (recovery log) for detailed information.
1.3.6.1.4.1.231.2.10.5NodesniTrapMib
Type Definitions
NameSyntaxStatusDescription
DisplayStringOCTET STRING
PhysAddressOCTET STRING