MIB Viewer

SNMP540-ALARM-MIB

15 objects
No module-level DESCRIPTION found.
OIDNameAccessStatusDescription
1.3.6.1.4.1.498.8.4.1Nodesnmp540AlarmTrapThe Enterprise specific Trap is sent whenever the alarm conditions are set in the network element. Each trap reported has a description of the alarm, the assoc…
1.3.6.1.4.1.498.8.4.10Nodesnmp540Alarm
1.3.6.1.4.1.498.8.4.10.1Scalarsnmp540AlarmMIBversionread-onlymandatoryIdentifies the version of the MIB. The format of the version is x.yzT, where 'x' identifies the major revision number, 'y'identifies the minor revision number,…
1.3.6.1.4.1.498.8.4.10.2Scalarsnmp540AlarmStructureread-writemandatoryThe Alarm Structure configuration object. The default value GDCProprietarySCMStandard(1) uses the alarm reporting structure as compliant to the SCM and the GDC…
1.3.6.1.4.1.498.8.4.10.3Scalarsnmp540AlarmNumberread-onlymandatoryThe number of Alarms Currently being reported by SNMP540 Unit.
1.3.6.1.4.1.498.8.4.10.4Scalarsnmp540GeneralIntegrationTimeread-writemandatoryThis is the DDS Alarm Threshold Interval. It specifies the amount of time, 1 to 15 minutes, in which the threshold setting is to be exceeded for the alarm to o…
1.3.6.1.4.1.498.8.4.10.5Tablesnmp540AlarmTablenot-accessiblemandatoryThe GDC snmp540 Alarm Configuration Table.
1.3.6.1.4.1.498.8.4.10.5.1Rowsnmp540AlarmEntrynot-accessiblemandatoryAn entry in the snmp540 alarm table.
1.3.6.1.4.1.498.8.4.10.5.1.1ColumnalarmNumberread-onlymandatoryThe index number associated with the entry in the Alarm table. The range cannot be specified on the SYNTAX line since it will vary from agent to agent. The ran…
1.3.6.1.4.1.498.8.4.10.5.1.2Columndescriptionread-onlymandatoryThe Description of the alarm generated.
1.3.6.1.4.1.498.8.4.10.5.1.3ColumnseverityLevelread-onlymandatoryThe severity level associated with the alarm in the Alarm table. The value critical(1) is critical for the enterprise functioning. The value major(1), minor(2)…
1.3.6.1.4.1.498.8.4.10.5.1.4Columnclassread-onlymandatoryThe class of the associated alarm in the Alarm table. The value general(1) indicates without the threshold or interval. The value threshold (2) indicates the a…
1.3.6.1.4.1.498.8.4.10.5.1.5Columnmaskread-writemandatoryThe alarm masking control. When the value is mask(1), then the alarm is masked and will not be reported. When the value is unmask(2), then the alarm will be re…
1.3.6.1.4.1.498.8.4.10.5.1.6Columnthresholdread-writemandatoryThis function sets/reads the alarm threshold settings criteria. This threshold is used along with the alarm window to determine the number of instances in a gi…
1.3.6.1.4.1.498.8.4.10.5.1.7Columnstatusread-onlymandatoryThe current status of the alarm. The value inactive(1) indicates that this alarm is currently inactive. The value active(2) indicates that this alarm is curren…