MIB Viewer

SONUS-SYSTEM-TIMING-MIB

78 objects
The MIB Module for System Timing management.
OIDNameAccessStatusDescription
1.3.6.1.4.1.2879.2.1.3IdentitysonusSystemTimingMIBThe MIB Module for System Timing management.
1.3.6.1.4.1.2879.2.1.3.1NodesonusSystemTimingMIBObjects
1.3.6.1.4.1.2879.2.1.3.1.1TablesonusStShelfAdmnTablenot-accessiblecurrent
1.3.6.1.4.1.2879.2.1.3.1.1.1RowsonusStShelfAdmnEntrynot-accessiblecurrent
1.3.6.1.4.1.2879.2.1.3.1.1.1.1ColumnsonusStShelfAdmnShelfIndexread-onlycurrentIdentifies the target shelf within the node.
1.3.6.1.4.1.2879.2.1.3.1.1.1.2ColumnsonusStShelfAdmnFailoverGuardTimeread-writecurrentIndicates how long a timing source can be faulting before switchover to another source is initiated
1.3.6.1.4.1.2879.2.1.3.1.1.1.3ColumnsonusStShelfAdmnRecoveryGuardTimeread-writecurrentIndicates how long a timing source must be valid for, after it has faulted, before it will be considered valid again.
1.3.6.1.4.1.2879.2.1.3.1.1.1.4ColumnsonusStShelfAdmnTransmitRemoteAlarmread-writecurrentNot Supported
1.3.6.1.4.1.2879.2.1.3.1.1.1.5ColumnsonusStShelfAdmnRevertRefSwitchingread-writecurrentIf enabled, then a timing source which has failed, but then becomes valid again, will be reconsidered for use. If disabled, then once a timing source fails, it…
1.3.6.1.4.1.2879.2.1.3.1.1.1.6ColumnsonusStShelfAdmnRevertMtaSwitchingread-writecurrentIf enabled, then an MTA which is hot-inserted will automatically be brought on line and made available for use. If disabled, then an MTA which is hot-inserted …
1.3.6.1.4.1.2879.2.1.3.1.1.1.7ColumnsonusStShelfAdmnRevertInsertDelayread-writecurrentMTA warm-up period. When an MTA is hot-inserted, the card will be allowed to warm up and stabilize for this amount of time before being put back into service. …
1.3.6.1.4.1.2879.2.1.3.1.1.1.8ColumnsonusStShelfAdmnFreeRunAlarmread-writecurrentNot Supported
1.3.6.1.4.1.2879.2.1.3.1.1.1.9ColumnsonusStShelfAdmnTimingSourceActionread-writecurrentResequence will cause the timing sequence list to be re-evaluated. This may cause the current active timing source to change.
1.3.6.1.4.1.2879.2.1.3.1.1.1.10ColumnsonusStShelfAdmnRowStatusread-writecurrentThis object indicates the row status for this table.
1.3.6.1.4.1.2879.2.1.3.1.1.1.11ColumnsonusStShelfAdmnSourceReconfigAlgread-writecurrentThis object indicates which algorithm should be used to select timing sources for use as System Synchronized sources. Selecting Ordered_list causes sources to …
1.3.6.1.4.1.2879.2.1.3.1.1.1.12ColumnsonusStShelfAdmnMtaSourceAffinityread-writecurrentThis object works in conjunction with the Source Reconfiguration Algorithm object. If sticky is selected, System Timing Manager will exhaust oll timing sources…
1.3.6.1.4.1.2879.2.1.3.1.2TablesonusStShelfStatTablenot-accessiblecurrent
1.3.6.1.4.1.2879.2.1.3.1.2.1RowsonusStShelfStatEntrynot-accessiblecurrent
1.3.6.1.4.1.2879.2.1.3.1.2.1.1ColumnsonusStShelfStatShelfIndexread-onlycurrent
1.3.6.1.4.1.2879.2.1.3.1.2.1.2ColumnsonusStShelfStatActiveMtaSlotread-onlycurrentIdentifies which MTA is providing the System Synchronized Timing signal.
1.3.6.1.4.1.2879.2.1.3.1.2.1.3ColumnsonusStShelfStatActiveSourceread-onlycurrentIdentifies what timing source the active MTA is using to provide System Synchronized Timing.
1.3.6.1.4.1.2879.2.1.3.1.3TablesonusStMtaAdmnTablenot-accessiblecurrent
1.3.6.1.4.1.2879.2.1.3.1.3.1RowsonusStMtaAdmnEntrynot-accessiblecurrent
1.3.6.1.4.1.2879.2.1.3.1.3.1.1ColumnsonusStMtaAdmnShelfIndexread-onlycurrentIdentifies the target shelf within the node.
1.3.6.1.4.1.2879.2.1.3.1.3.1.2ColumnsonusStMtaAdmnMtaSlotIndexread-onlycurrentIdentifies the target slot within the shelf.
1.3.6.1.4.1.2879.2.1.3.1.3.1.3ColumnsonusStMtaAdmnStateread-writecurrentIf enabled, the MTA can participate in system timing. If disabled, then it will be removed from service and not allowed to participate. All timing sequence ent…
1.3.6.1.4.1.2879.2.1.3.1.3.1.4ColumnsonusStMtaAdmnLineEncodingread-writecurrentSelect AMI or B8ZS line coding for BITS LIU. Select HDB3 for SETS LIU
1.3.6.1.4.1.2879.2.1.3.1.3.1.5ColumnsonusStMtaAdmnSsmChannelBitread-writecurrentMTA 20, E1 support only. Identifies which of the additional spare bits, embedded within the framing pattern, contains the SSM channel
1.3.6.1.4.1.2879.2.1.3.1.3.1.6ColumnsonusStMtaAdmnFramerModeread-writecurrentSelect ESF or D4/SF for BITS framer. ESF should be selected if B8ZS has been selected for the line encoding. D4/SF should be selected if AMI has been selected …
1.3.6.1.4.1.2879.2.1.3.1.3.1.7ColumnsonusStMtaAdmnFramerTransmitYellowAlarmread-writecurrentNot supported
1.3.6.1.4.1.2879.2.1.3.1.3.1.8ColumnsonusStMtaAdmnLiuTransmitAllOnesread-writecurrentNot supported
1.3.6.1.4.1.2879.2.1.3.1.3.1.9ColumnsonusStMtaAdmnActionread-writecurrentSelecting AVAILABLE will cause the MTA to be moved from the Out-Of-Service state to the Available-For-Use state. This command is necessary to manually make an …
1.3.6.1.4.1.2879.2.1.3.1.3.1.10ColumnsonusStMtaAdmnRowStatusread-writecurrentThis object indicates the row status for this table.
1.3.6.1.4.1.2879.2.1.3.1.4TablesonusStMtaStatTablenot-accessiblecurrent
1.3.6.1.4.1.2879.2.1.3.1.4.1RowsonusStMtaStatEntrynot-accessiblecurrent
1.3.6.1.4.1.2879.2.1.3.1.4.1.1ColumnsonusStMtaStatShelfIndexread-onlycurrent
1.3.6.1.4.1.2879.2.1.3.1.4.1.2ColumnsonusStMtaStatMtaSlotIndexread-onlycurrent
1.3.6.1.4.1.2879.2.1.3.1.4.1.3ColumnsonusStMtaStatOperStatread-onlycurrentIndicates the operational status of the MTA
1.3.6.1.4.1.2879.2.1.3.1.4.1.4ColumnsonusStMtaStatMtaHwDescread-onlycurrentDescription of the MTA hardware in the form of 'hwtype_hwRev'.
1.3.6.1.4.1.2879.2.1.3.1.4.1.5ColumnsonusStMtaStatMtaHwTyperead-onlycurrentDescription of the MTA hardware Type only. Entry 5+6 obsolete entry 4.
1.3.6.1.4.1.2879.2.1.3.1.4.1.6ColumnsonusStMtaStatMtaHwTypeRevread-onlycurrentDescription of the MTA hardware type revision. Entry 5+6 obsolete entry 4.
1.3.6.1.4.1.2879.2.1.3.1.4.1.7ColumnsonusStMtaStatMtaSerialNumread-onlycurrentIdentifies the serial number of the server module. This is the serial number assigned to the mta module in manufacturing.
1.3.6.1.4.1.2879.2.1.3.1.4.1.8ColumnsonusStMtaStatMtaPartNumread-onlycurrentIdentifies the part number of the server module. This is the part number assigned to the mta module in manufacturing.
1.3.6.1.4.1.2879.2.1.3.1.5TablesonusStTimingSourceTablenot-accessiblecurrent
1.3.6.1.4.1.2879.2.1.3.1.5.1RowsonusStTimingSourceEntrynot-accessiblecurrent
1.3.6.1.4.1.2879.2.1.3.1.5.1.1ColumnsonusStTimingSourceShelfIndexread-writecurrent
1.3.6.1.4.1.2879.2.1.3.1.5.1.2ColumnsonusStTimingSourceMtaSlotIndexread-writecurrentIndicates which MTA this timing node is bound to.
1.3.6.1.4.1.2879.2.1.3.1.5.1.3ColumnsonusStTimingSourceread-writecurrentIndicates which physical timing source is bound to this node. External BITS sources are used by MTA 10's, in T1 based chassis'. External SETS sources are used …
1.3.6.1.4.1.2879.2.1.3.1.5.1.4ColumnsonusStTimingSourceStateread-writecurrentIf enabled, the source can participate in system timing. If disabled, then it will be removed from service and not be allowed to participate.
1.3.6.1.4.1.2879.2.1.3.1.5.1.5ColumnsonusStTimingSourceSequenceNumread-writecurrentThe timing sequence number is automatically generated
1.3.6.1.4.1.2879.2.1.3.1.5.1.6ColumnsonusStTimingSourceActionread-writecurrentSelecting AVAILABLE will cause the timing source to be moved from the Out-Of-Service state to the Available-For-Use state. This command is necessary to manuall…
1.3.6.1.4.1.2879.2.1.3.1.5.1.7ColumnsonusStTimingSourceRowStatusread-writecurrentThis object indicates the row status for this table.
1.3.6.1.4.1.2879.2.1.3.1.6TablesonusStTimingSourceStatTablenot-accessiblecurrent
1.3.6.1.4.1.2879.2.1.3.1.6.1RowsonusStTimingSourceStatEntrynot-accessiblecurrent
1.3.6.1.4.1.2879.2.1.3.1.6.1.1ColumnsonusStTimingSourceStatShelfIndexread-onlycurrentIndicates shelf.
1.3.6.1.4.1.2879.2.1.3.1.6.1.2ColumnsonusStTimingSourceStatMtaSlotIndexread-onlycurrentIndicates which MTA this timing node is bound to.
1.3.6.1.4.1.2879.2.1.3.1.6.1.3ColumnsonusStTimingSourceStatread-onlycurrentIndicates the physical timing source
1.3.6.1.4.1.2879.2.1.3.1.6.1.4ColumnsonusStTimingSourceStatStateread-onlycurrentIndicates the current overall state of the timing source, including the hardware state, adminitrative mode and shelf configuration
1.3.6.1.4.1.2879.2.1.3.1.6.1.5ColumnsonusStTimingSourceStatTraceabilityread-onlycurrentIndicates the Quality Level of the System Synchronized Timing Source
1.3.6.1.4.1.2879.2.1.3.1.6.1.6ColumnsonusStTimingSourceStatLineStateread-onlycurrentIndicates the current physical status of the timing source
1.3.6.1.4.1.2879.2.1.3.1.7TablesonusStChannelBindingTablenot-accessiblecurrentThis table describes how derived timing sources should be mapped to the MTA hardware
1.3.6.1.4.1.2879.2.1.3.1.7.1RowsonusStChannelBindingEntrynot-accessiblecurrent
1.3.6.1.4.1.2879.2.1.3.1.7.1.1ColumnsonusStChannelBindingShelfIndexread-onlycurrent
1.3.6.1.4.1.2879.2.1.3.1.7.1.2ColumnsonusStChannelBindingSlotIndexread-onlycurrentServer slot number to provide a recovered clock source. The same server can be configured to provide both possible recovered clocks as long as different channe…
1.3.6.1.4.1.2879.2.1.3.1.7.1.3ColumnsonusStChannelBindingChannelread-onlycurrentT1/E1 span or OC12 port number to provide the recovered clock source. T1 span range is 1-12(CNS10), 1-28(CNS30), E1 span range is 1-8(CNS20), OC12 port number(…
1.3.6.1.4.1.2879.2.1.3.1.7.1.4ColumnsonusStChannelBindingRefClkread-onlycurrentBackplane signal the recovered clock source should be bound to. Each REFCLK must only be bound to a single Server slot/span.
1.3.6.1.4.1.2879.2.1.3.1.7.1.5ColumnsonusStChannelBindingRowStatusread-writecurrentThis object indicates the row status for this table.
1.3.6.1.4.1.2879.2.1.3.2NodesonusSystemTimingMIBNotifications
1.3.6.1.4.1.2879.2.1.3.2.0NodesonusSystemTimingMIBNotificationsPrefix
1.3.6.1.4.1.2879.2.1.3.2.0.1NotificationsonusSystemTimingActiveFailedNotificationcurrentThis trap indicates that the currently active System Timing clock source has failed.
1.3.6.1.4.1.2879.2.1.3.2.0.2NotificationsonusSystemTimingActiveSwitchoverNotificationcurrentThis trap indicates that the active System Timing clock source has been switched to another source.
1.3.6.1.4.1.2879.2.1.3.2.0.3NotificationsonusSystemTimingOscillatorActiveNotificationcurrentThis trap indicates that all external sources of System Timing have failed and that the current source of timing is the MTA's internal oscillator.
1.3.6.1.4.1.2879.2.1.3.2.0.4NotificationsonusSystemTimingMTAFailedNotificationcurrentThis trap indicates that the MTA indicated has failed or been removed from the shelf.
1.3.6.1.4.1.2879.2.1.3.2.0.6NotificationsonusSystemTimingMTAOperationalNotificationcurrentThis trap indicates that the specified MTA is now operational.
1.3.6.1.4.1.2879.2.1.3.2.0.7NotificationsonusSystemTimingMTATotalFailureNotificationcurrentThis trap indicates that no MTA's are available for use to provide System Timing. They have either failed, been removed from service or been removed from the s…
1.3.6.1.4.1.2879.2.1.3.2.1NodesonusSystemTimingMIBNotificationsObjects
1.3.6.1.4.1.2879.2.1.3.2.1.1ScalarsonusTimingSourceread-onlycurrent
1.3.6.1.4.1.2879.2.1.3.2.1.2ScalarsonusTimingSource2read-onlycurrent