MIB Viewer

SPC200

258 objects
Description
Imported Objects
IF-MIBifIndex interfaces
SNMPv2-CONFAGENT-CAPABILITIES MODULE-COMPLIANCE OBJECT-GROUP
SNMPv2-SMICounter32 Gauge32 Integer32 IpAddress MODULE-IDENTITY OBJECT-IDENTITY OBJECT-TYPE Unsigned32
SNMPv2-TCDisplayString MacAddress RowStatus TEXTUAL-CONVENTION TruthValue
SPIDCOM-MIBspidcom
OIDNameAccessStatusDescription
1.3.6.1.4.1.22764.1Identityspc200MIBDescription
1.3.6.1.4.1.22764.1.1Nodeplc
1.3.6.1.4.1.22764.1.1.1Nodestats
1.3.6.1.4.1.22764.1.1.1.2TableportStatsTablenot-accessiblecurrentThis table gathers all statistic data specific to SPC200 chip relative to plc connection.
1.3.6.1.4.1.22764.1.1.1.2.1RowportStatsEntrynot-accessiblecurrentThis row contains statistic data specific to SPC200 chip relative to a connection.
1.3.6.1.4.1.22764.1.1.1.2.1.1ColumnportStatsBandIndexnot-accessiblecurrentThe band number on which the signal, noise, ber data are collected.
1.3.6.1.4.1.22764.1.1.1.2.1.2ColumnportStatsGroupIndexnot-accessiblecurrentThe group number on which the signal, noise, ber data are collected
1.3.6.1.4.1.22764.1.1.1.2.1.3ColumnportStatsCarrierIndexnot-accessiblecurrentThe group number on which the signal, noise, ber data are collected
1.3.6.1.4.1.22764.1.1.1.2.1.4ColumnportStatsSignalread-onlycurrentThe DB value of the signal associated with the carrier wave entry.
1.3.6.1.4.1.22764.1.1.1.2.1.5ColumnportStatsNoiseread-onlycurrentThe DB value of the noise associated with the carrier wave entry.
1.3.6.1.4.1.22764.1.1.1.3TableportStats2Tablenot-accessiblecurrentThis table gathers all statistic data specific to SPC200 chip relative to plc channels. This table has the same information as the portChannelStatsTable but in…
1.3.6.1.4.1.22764.1.1.1.3.1RowportStats2Entrynot-accessiblecurrentThis row contains statistic data specific to SPC200 chip relative to a connection.
1.3.6.1.4.1.22764.1.1.1.3.1.1ColumnportStats2Signalread-onlycurrentThe values of the signal for all the carrier waves. The expected format is VALUE VALUE VALUE ... VALUE. Each value is coded on two bytes. There is one value fo…
1.3.6.1.4.1.22764.1.1.1.3.1.2ColumnportStats2Noiseread-onlycurrentThe values of the noise for all the carrier waves. The expected format is VALUE VALUE VALUE ... VALUE. Each value is coded on two bytes. There is one value for…
1.3.6.1.4.1.22764.1.1.1.3.1.3ColumnportStats2AvgBandAttread-onlycurrentAverage attenuation per band (dB).
1.3.6.1.4.1.22764.1.1.1.3.1.4ColumnportStats2AvgBandSNRread-onlycurrentAverage SNR per band (dB).
1.3.6.1.4.1.22764.1.1.1.4TableportStats3Tablenot-accessiblecurrentThis table gathers all statistic data specific to SPC200 chip relative to plc channels. This table has the same information as the portChannelStatsTable but in…
1.3.6.1.4.1.22764.1.1.1.4.1RowportStats3Entrynot-accessiblecurrentThis row contains statistic data specific to SPC200 chip relative to a connection.
1.3.6.1.4.1.22764.1.1.1.4.1.1ColumnportStats3AvgAttread-onlycurrentAverage attenuation on the link (dB).
1.3.6.1.4.1.22764.1.1.1.4.1.2ColumnportStats3AvgSNRread-onlycurrentAverage SNR on the link (dB).
1.3.6.1.4.1.22764.1.1.1.5Identitybootstatscurrentboot statistics
1.3.6.1.4.1.22764.1.1.1.5.1ScalarbootstatsBootread-onlycurrentBoot
1.3.6.1.4.1.22764.1.1.1.5.2ScalarbootstatsManualResetread-onlycurrentManual reset
1.3.6.1.4.1.22764.1.1.1.5.3ScalarbootstatsFailureResetread-onlycurrentFailure reset
1.3.6.1.4.1.22764.1.1.2NodeplcObjects
1.3.6.1.4.1.22764.1.1.2.1ScalarplcModeread-writecurrentPlc Mode
1.3.6.1.4.1.22764.1.1.2.2NodeplcTopo
1.3.6.1.4.1.22764.1.1.2.2.1ScalarplcTopoChangesread-onlycurrentThe total number of topology changes detected by this plc bridge since the management entity was last reset or initialized. Such changes concerns only - the pl…
1.3.6.1.4.1.22764.1.1.2.2.2TableplcBasePortTablenot-accessiblecurrentThis table contains the list of plc remote connection
1.3.6.1.4.1.22764.1.1.2.2.2.1RowplcBasePortEntrynot-accessiblecurrentThis row contains plc remote connection information
1.3.6.1.4.1.22764.1.1.2.2.2.1.1ColumnplcBasePortIndexnot-accessiblecurrentThe MAC address of the MAC layer above the plc interface of the remote PLC equipment.
1.3.6.1.4.1.22764.1.1.2.2.2.1.2ColumnplcBasePortAddressread-onlycurrentThe MAC address of the MAC layer above the plc interface of the remote PLC equipment.
1.3.6.1.4.1.22764.1.1.2.2.2.1.3ColumnplcBasePortChannelEstimationread-writecurrentEnable or disable the automatic channel estimation processus.
1.3.6.1.4.1.22764.1.1.2.2.2.1.4ColumnplcBasePortAttenuationread-onlycurrentLink attenuation (dB).
1.3.6.1.4.1.22764.1.1.2.2.3TableplcChannelModulationStringTablenot-accessiblecurrentThis table contains string values for a quick access to the modulation amplitude configurations of all active channels.
1.3.6.1.4.1.22764.1.1.2.2.3.1RowplcChannelModulationStringEntrynot-accessiblecurrentThis row contains string values for a quick access to the modulation amplitude configuration of each active channel of the remote connection referenced by plcB…
1.3.6.1.4.1.22764.1.1.2.2.3.1.1ColumnplcRxChannelModulationread-onlycurrentThe modulation amplitude values for the Rx channel of a given remote connection entry. The expected format is VALUE VALUE VALUE ... VALUE. Each value is an oct…
1.3.6.1.4.1.22764.1.1.2.2.3.1.2ColumnplcRxLastChannelModulationread-onlycurrentThe modulation amplitude values for the Rx Last channel of a given remote connection entry. The expected format is VALUE VALUE VALUE ... VALUE. Each value is a…
1.3.6.1.4.1.22764.1.1.2.2.3.1.3ColumnplcTxChannelModulationread-onlycurrentThe modulation amplitude values for the Tx channel of a given remote connection entry. The expected format is VALUE VALUE VALUE ... VALUE. Each value is an oct…
1.3.6.1.4.1.22764.1.1.2.2.4TableplcChannelModulationTablenot-accessiblecurrentThis table contains the modulation amplitude configuration of all active channels.
1.3.6.1.4.1.22764.1.1.2.2.4.1RowplcChannelModulationEntrynot-accessiblecurrentThis row contains modulation amplitude configuration of the channel, referenced by the plcPortChannelIndex, of the remote connection referenced by plcBasePortI…
1.3.6.1.4.1.22764.1.1.2.2.4.1.1ColumnplcModBandIndexnot-accessiblecurrentThe band number of which the modulations are defined
1.3.6.1.4.1.22764.1.1.2.2.4.1.2ColumnplcModGroup1read-onlycurrentThe modulation amplitude of the first group of the band entry of the channel entry for a given remote connection entry.
1.3.6.1.4.1.22764.1.1.2.2.4.1.3ColumnplcModGroup2read-onlycurrentThe modulation amplitude of the second group of the band entry of the channel entry for a given remote connection entry.
1.3.6.1.4.1.22764.1.1.2.2.4.1.4ColumnplcModGroup3read-onlycurrentThe modulation amplitude of the third group of the band entry of the channel entry for a given remote connection entry.
1.3.6.1.4.1.22764.1.1.2.2.4.1.5ColumnplcModGroup4read-onlycurrentThe modulation amplitude of the fourth group of the band entry of the channel entry for a given remote connection entry.
1.3.6.1.4.1.22764.1.1.2.2.4.1.6ColumnplcModGroup5read-onlycurrentThe modulation amplitude of the fifth group of the band entry of the channel entry for a given remote connection entry.
1.3.6.1.4.1.22764.1.1.2.2.4.1.7ColumnplcModGroup6read-onlycurrentThe modulation amplitude of the sixth group of the band entry of the channel entry for a given remote connection entry.
1.3.6.1.4.1.22764.1.1.2.2.4.1.8ColumnplcModGroup7read-onlycurrentThe modulation amplitude of the seventh group of the band entry of the channel entry for a given remote connection entry.
1.3.6.1.4.1.22764.1.1.2.2.4.1.9ColumnplcModGroup8read-onlycurrentThe modulation amplitude of the eighth group of the band entry of the channel entry for a given remote connection entry.
1.3.6.1.4.1.22764.1.1.2.2.4.1.10ColumnplcModGroup9read-onlycurrentThe modulation amplitude of the nineth group of the band entry of the channel entry for a given remote connection entry.
1.3.6.1.4.1.22764.1.1.2.2.4.1.11ColumnplcModGroup10read-onlycurrentThe modulation amplitude of the tenth group of the band entry of the channel entry for a given remote connection entry.
1.3.6.1.4.1.22764.1.1.2.2.4.1.12ColumnplcModGroup11read-onlycurrentThe modulation amplitude of the eleventh group of the band entry of the channel entry for a given remote connection entry.
1.3.6.1.4.1.22764.1.1.2.2.4.1.13ColumnplcModGroup12read-onlycurrentThe modulation amplitude of the twelveth group of the band entry of the channel entry for a given remote connection entry.
1.3.6.1.4.1.22764.1.1.2.2.4.1.14ColumnplcModGroup13read-onlycurrentThe modulation amplitude of the thirteenth group of the band entry of the channel entry for a given remote connection entry.
1.3.6.1.4.1.22764.1.1.2.2.4.1.15ColumnplcModGroup14read-onlycurrentThe modulation amplitude of the fourteenth group of the band entry of the channel entry for a given remote connection entry.
1.3.6.1.4.1.22764.1.1.2.2.4.1.16ColumnplcModGroup15read-onlycurrentThe modulation amplitude of the fifteenth group of the band entry of the channel entry for a given remote connection entry.
1.3.6.1.4.1.22764.1.1.2.2.4.1.17ColumnplcModGroup16read-onlycurrentThe modulation amplitude of the sixteenth group of the band entry of the channel entry for a given remote connection entry.
1.3.6.1.4.1.22764.1.1.2.2.5NodeplcChannelModulationInput
1.3.6.1.4.1.22764.1.1.2.2.5.1ScalarplcModulationInputAddrread-writecurrentThe MAC address of the MAC layer above the plc interface of the remote PLC equipment for which the modulation value changes are requested.
1.3.6.1.4.1.22764.1.1.2.2.5.2ScalarplcModulationInputChannelread-writecurrentThe channel type of the remote PLC equipment for which the modulation value changes are requested.
1.3.6.1.4.1.22764.1.1.2.2.5.3ScalarplcModulationInputBandread-writecurrentThe band number of which the modulation value changes are requested.
1.3.6.1.4.1.22764.1.1.2.2.5.4ScalarplcInputModulationGroup1read-writecurrentThe new requested modulation amplitude of the first group of the considered band and channel input values.
1.3.6.1.4.1.22764.1.1.2.2.5.5ScalarplcInputModulationGroup2read-writecurrentThe new requested modulation amplitude of the second group of the considered band and channel input values.
1.3.6.1.4.1.22764.1.1.2.2.5.6ScalarplcInputModulationGroup3read-writecurrentThe new requested modulation amplitude of the third group of the considered band and channel input values.
1.3.6.1.4.1.22764.1.1.2.2.5.7ScalarplcInputModulationGroup4read-writecurrentThe new requested modulation amplitude of the fourth group of the considered band and channel input values.
1.3.6.1.4.1.22764.1.1.2.2.5.8ScalarplcInputModulationGroup5read-writecurrentThe new requested modulation amplitude of the fifth group of the considered band and channel input values.
1.3.6.1.4.1.22764.1.1.2.2.5.9ScalarplcInputModulationGroup6read-writecurrentThe new requested modulation amplitude of the sixth group of the considered band and channel input values.
1.3.6.1.4.1.22764.1.1.2.2.5.10ScalarplcInputModulationGroup7read-writecurrentThe new requested modulation amplitude of the seventh group of the considered band and channel input values.
1.3.6.1.4.1.22764.1.1.2.2.5.11ScalarplcInputModulationGroup8read-writecurrentThe new requested modulation amplitude of the eighth group of the considered band and channel input values.
1.3.6.1.4.1.22764.1.1.2.2.5.12ScalarplcInputModulationGroup9read-writecurrentThe new requested modulation amplitude of the nineth group of the considered band and channel input values.
1.3.6.1.4.1.22764.1.1.2.2.5.13ScalarplcInputModulationGroup10read-writecurrentThe new requested modulation amplitude of the tenth group of the considered band and channel input values.
1.3.6.1.4.1.22764.1.1.2.2.5.14ScalarplcInputModulationGroup11read-writecurrentThe new requested modulation amplitude of the eleventh group of the considered band and channel input values.
1.3.6.1.4.1.22764.1.1.2.2.5.15ScalarplcInputModulationGroup12read-writecurrentThe new requested modulation amplitude of the twelveth group of the considered band and channel input values.
1.3.6.1.4.1.22764.1.1.2.2.5.16ScalarplcInputModulationGroup13read-writecurrentThe new requested modulation amplitude of the thirteenth group of the considered band and channel input values.
1.3.6.1.4.1.22764.1.1.2.2.5.17ScalarplcInputModulationGroup14read-writecurrentThe new requested modulation amplitude of the fourteenth group of the considered band and channel input values.
1.3.6.1.4.1.22764.1.1.2.2.5.18ScalarplcInputModulationGroup15read-writecurrentThe new requested modulation amplitude of the fifteenth group of the considered band and channel input values.
1.3.6.1.4.1.22764.1.1.2.2.5.19ScalarplcInputModulationGroup16read-writecurrentThe new requested modulation amplitude of the sixteenth group of the considered band and channel input values.
1.3.6.1.4.1.22764.1.1.2.2.5.20ScalarplcModulationInputProceedread-writecurrentTrue to request a modification of all the modulations associated to a band and a channel of a remote PLC equipment.
1.3.6.1.4.1.22764.1.1.2.2.5.21ScalarplcModulationInputResultread-onlycurrentResult value of the requested modulation value changes.
1.3.6.1.4.1.22764.1.1.2.2.6TableplcPortChannelTablenot-accessiblecurrentThis table contains the list of plc channels
1.3.6.1.4.1.22764.1.1.2.2.6.1RowplcPortChannelEntrynot-accessiblecurrentThis row contains plc channel information
1.3.6.1.4.1.22764.1.1.2.2.6.1.1ColumnplcPortChannelIndexnot-accessiblecurrentThe channel number belongs to the remote connection with plc equipment associated with the plcBasePortIndex value. Only three channels are expected. Index 1 fo…
1.3.6.1.4.1.22764.1.1.2.2.6.1.2ColumnplcPortChannelTyperead-onlycurrentThe channel type.
1.3.6.1.4.1.22764.1.1.2.2.6.1.3ColumnplcPortChannelGainread-writecurrentThe gain associated with the channel.
1.3.6.1.4.1.22764.1.1.2.2.6.1.4ColumnplcPortChannelBandwidthread-onlycurrentThe bandwidth of the channel in Kbit/s.
1.3.6.1.4.1.22764.1.1.2.2.6.1.5ColumnplcPortChannelMaxBandwidthread-onlycurrentThe maximum bandwidth of the channel in Kbit/s.
1.3.6.1.4.1.22764.1.1.2.2.6.1.6ColumnplcPortChannelSynchronizationBandread-onlycurrentThe synchronization band used for this channel.
1.3.6.1.4.1.22764.1.1.2.2.7TableplcChannelPilotStringTablenot-accessiblecurrentThis table contains the string values representing of pilot values of all active channels.
1.3.6.1.4.1.22764.1.1.2.2.7.1RowplcChannelPilotStringEntrynot-accessiblecurrentThis row contains a quick access for pilot values , of the remote connection referenced by plcBasePortIndex.
1.3.6.1.4.1.22764.1.1.2.2.7.1.1ColumnplcRxChannelPilotsread-onlycurrentThe carrier wave numbers which support the pilot waves for the Rx Channel. The expected format is VALUE VALUE VALUE ... VALUE. Each value is a pair of octets r…
1.3.6.1.4.1.22764.1.1.2.2.7.1.2ColumnplcRxLastChannelPilotsread-onlycurrentThe carrier wave numbers which support the pilot waves for the Rx Last Channel. The expected format is VALUE VALUE VALUE ... VALUE. Each value is a pair of oct…
1.3.6.1.4.1.22764.1.1.2.2.7.1.3ColumnplcTxChannelPilotsread-onlycurrentThe carrier wave numbers which support the pilot waves for the Tx Channel. The expected format is VALUE VALUE VALUE ... VALUE. Each value is a pair of octets r…
1.3.6.1.4.1.22764.1.1.2.2.8TableplcChannelPilotsTablenot-accessiblecurrentThis tabel contains pilots configuration for each plc channel.
1.3.6.1.4.1.22764.1.1.2.2.8.1RowplcChannelPilotsEntrynot-accessiblecurrentThis row contains the pilots 1 and 2 configuration for a channel defined by the couple (plcBasePortIndex, plcPortChannelIndex)
1.3.6.1.4.1.22764.1.1.2.2.8.1.1ColumnplcChannelPilotBandIndexnot-accessiblecurrentThe band number on which the pilots are defined.
1.3.6.1.4.1.22764.1.1.2.2.8.1.2ColumnplcChannelPilot1read-onlycurrentThe carrier wave number which supports the first pilot wave for the channel associated with this entry.
1.3.6.1.4.1.22764.1.1.2.2.8.1.3ColumnplcChannePilot2read-onlycurrentThe carrier wave number which supports the second pilot wave for the channel associated with this entry.
1.3.6.1.4.1.22764.1.1.2.2.9NodeplcChannelPilotsInput
1.3.6.1.4.1.22764.1.1.2.2.9.1ScalarplcPilotsInputAddrread-writecurrentThe MAC address of the MAC layer above the plc interface of the remote PLC equipment for which the pilot value changes are requested.
1.3.6.1.4.1.22764.1.1.2.2.9.2ScalarplcPilotsInputChannelread-writecurrentThe channel type of the remote PLC equipment for which the pilot value changes are requested.
1.3.6.1.4.1.22764.1.1.2.2.9.3ScalarplcPilotsInputBandread-writecurrentThe band number of which the pilots value changes are requested.
1.3.6.1.4.1.22764.1.1.2.2.9.4ScalarplcInputChannelPilot1read-writecurrentThe carrier wave number which supports the first pilot wave for the considered band and channel input values.
1.3.6.1.4.1.22764.1.1.2.2.9.5ScalarplcInputChannelPilot2read-writecurrentThe carrier wave number which supports the second pilot wave for the considered band and channel input values.
1.3.6.1.4.1.22764.1.1.2.2.9.6ScalarplcPilotsInputProceedread-writecurrentTrue to request a modification of the first and second pilot associated to a band and a channel of a remote PLC equipment.
1.3.6.1.4.1.22764.1.1.2.2.9.7ScalarplcPilotsInputResultread-onlycurrentResult value of the requested pilot values changes.
1.3.6.1.4.1.22764.1.1.2.3NodeplcNodeConfiguration
1.3.6.1.4.1.22764.1.1.2.3.1ScalarplcNodeNotchesread-onlycurrentThe values of the notches for all the node bands. The expected format is VALUE VALUE VALUE ... VALUE. Each value is an octet representing the 8 notches of each…
1.3.6.1.4.1.22764.1.1.2.3.2TableplcNodeNotchesTablenot-accessiblecurrentThis table contains Notches configuration for the SPC200 chip.
1.3.6.1.4.1.22764.1.1.2.3.2.1RowplcNodeNotchesEntrynot-accessiblecurrentThis row contains Notches configuration for a group. The group is defined by the couple (plcNodeNotchesGroupIndex, plcNodeNotchesBandIndex).
1.3.6.1.4.1.22764.1.1.2.3.2.1.1ColumnplcNodeNotchesBandIndexnot-accessiblecurrentThe band number on which the notches are defined.
1.3.6.1.4.1.22764.1.1.2.3.2.1.2ColumnplcNodeNotchesGroupIndexnot-accessiblecurrentThe group number on which the notches are defined.
1.3.6.1.4.1.22764.1.1.2.3.2.1.3ColumnplcNodeNotchesCarrier1read-onlycurrentTell if the first carrier of the group entry of the band entry is a notch carrier. The true value means the current carrier is a notch.
1.3.6.1.4.1.22764.1.1.2.3.2.1.4ColumnplcNodeNotchesCarrier2read-onlycurrentTell if the second carrier of the group entry of the band entry is a notch carrier. The true value means the current carrier is a notch.
1.3.6.1.4.1.22764.1.1.2.3.2.1.5ColumnplcNodeNotchesCarrier3read-onlycurrentTell if the third carrier of the group entry of the band entry is a notch carrier. The true value means the current carrier is a notch.
1.3.6.1.4.1.22764.1.1.2.3.2.1.6ColumnplcNodeNotchesCarrier4read-onlycurrentTell if the fourth carrier of the group entry of the band entry is a notch carrier. The true value means the current carrier is a notch.
1.3.6.1.4.1.22764.1.1.2.3.2.1.7ColumnplcNodeNotchesCarrier5read-onlycurrentTell if the fifth carrier of the group entry of the band entry is a notch carrier. The true value means the current carrier is a notch.
1.3.6.1.4.1.22764.1.1.2.3.2.1.8ColumnplcNodeNotchesCarrier6read-onlycurrentTell if the sixth carrier of the group entry of the band entry is a notch carrier. The true value means the current carrier is a notch.
1.3.6.1.4.1.22764.1.1.2.3.2.1.9ColumnplcNodeNotchesCarrier7read-onlycurrentTell if the seventh carrier of the group entry of the band entry is a notch carrier. The true value means the current carrier is a notch.
1.3.6.1.4.1.22764.1.1.2.3.2.1.10ColumnplcNodeNotchesCarrier8read-onlycurrentTell if the eighth carrier of the group entry of the band entry is a notch carrier. The true value means the current carrier is a notch.
1.3.6.1.4.1.22764.1.1.2.3.3NodeplcNodeNotchesInput
1.3.6.1.4.1.22764.1.1.2.3.3.1ScalarplcNodeNotchesInputBandread-writecurrentThe band number on which the notches value changes are requested.
1.3.6.1.4.1.22764.1.1.2.3.3.2ScalarplcNodeNotchesInputGroupread-writecurrentThe group number on which the notches value changes are requested.
1.3.6.1.4.1.22764.1.1.2.3.3.3ScalarplcNodeNotchesInputCarrier1read-writecurrentThe first carrier of the considered group and band is a notch carrier. The true value means the current carrier is a notch.
1.3.6.1.4.1.22764.1.1.2.3.3.4ScalarplcNodeNotchesInputCarrier2read-writecurrentThe second carrier of the considered group and band is a notch carrier. The true value means the current carrier is a notch.
1.3.6.1.4.1.22764.1.1.2.3.3.5ScalarplcNodeNotchesInputCarrier3read-writecurrentThe third carrier of the considered group and band is a notch carrier. The true value means the current carrier is a notch.
1.3.6.1.4.1.22764.1.1.2.3.3.6ScalarplcNodeNotchesInputCarrier4read-writecurrentThe fourth carrier of the considered group and band is a notch carrier. The true value means the current carrier is a notch.
1.3.6.1.4.1.22764.1.1.2.3.3.7ScalarplcNodeNotchesInputCarrier5read-writecurrentThe eighth carrier of the considered group and band is a notch carrier. The true value means the current carrier is a notch.
1.3.6.1.4.1.22764.1.1.2.3.3.8ScalarplcNodeNotchesInputCarrier6read-writecurrentThe eighth carrier of the considered group and band is a notch carrier. The true value means the current carrier is a notch.
1.3.6.1.4.1.22764.1.1.2.3.3.9ScalarplcNodeNotchesInputCarrier7read-writecurrentThe seventh carrier of the considered group and band is a notch carrier. The true value means the current carrier is a notch.
1.3.6.1.4.1.22764.1.1.2.3.3.10ScalarplcNodeNotchesInputCarrier8read-writecurrentThe eighth carrier of the considered group and band is a notch carrier. The true value means the current carrier is a notch.
1.3.6.1.4.1.22764.1.1.2.3.3.11ScalarplcNodeNotchesInputProceedread-writecurrentTrue to request a modification of the carrier notches associated to the considered group and band.
1.3.6.1.4.1.22764.1.1.2.3.3.12ScalarplcNodeNotchesInputResultread-onlycurrentResult value of the requested node carrier notches value changes.
1.3.6.1.4.1.22764.1.1.2.3.4ScalarplcNodePilotsread-onlycurrentThe values of the pilot for all the node bands. The expected format is VALUE VALUE VALUE ... VALUE. Each value is a pair of octets representing the pilot value…
1.3.6.1.4.1.22764.1.1.2.3.5TableplcNodePilotsTablenot-accessiblecurrentThis table contains pilot values used by default on all channels.
1.3.6.1.4.1.22764.1.1.2.3.5.1RowplcNodePilotsEntrynot-accessiblecurrentThis row contains pilot values used by default on a band. The band is defined by the index plcNodePilotsBandIndex.
1.3.6.1.4.1.22764.1.1.2.3.5.1.1ColumnplcNodePilotsBandIndexnot-accessiblecurrentThe band number on which the pilot values are defined.
1.3.6.1.4.1.22764.1.1.2.3.5.1.2ColumnplcNodePilot1read-onlycurrentThe default carrier wave number which supports the first pilot wave.
1.3.6.1.4.1.22764.1.1.2.3.5.1.3ColumnplcNodePilot2read-onlycurrentThe default carrier wave number which supports the second pilot wave.
1.3.6.1.4.1.22764.1.1.2.3.6NodeplcNodePilotsInput
1.3.6.1.4.1.22764.1.1.2.3.6.1ScalarplcNodePilotsInputBandread-writecurrentThe band number on which the pilot values changes are requested.
1.3.6.1.4.1.22764.1.1.2.3.6.2ScalarplcInputNodePilot1read-writecurrentThe default carrier wave number which supports the first pilot wave of the considered band.
1.3.6.1.4.1.22764.1.1.2.3.6.3ScalarplcInputNodePilot2read-writecurrentThe default carrier wave number which supports the second pilot wave of the considered band.
1.3.6.1.4.1.22764.1.1.2.3.6.4ScalarplcNodePilotsInputProceedread-writecurrentTrue to request a modification of the pilot values associated to the considered band.
1.3.6.1.4.1.22764.1.1.2.3.6.5ScalarplcNodePilotsInputResultread-onlycurrentResult value of the requested node pilot values changes.
1.3.6.1.4.1.22764.1.1.2.3.7TableplcNodeAdaptsStringTablenot-accessiblecurrentThis table contains string values for a quick access to the adapt configurations of all the carriers.
1.3.6.1.4.1.22764.1.1.2.3.7.1RowplcNodeAdaptsStringEntrynot-accessiblecurrentThis row contains string values for a quick access to the adapt configuration of each carrier of a band.
1.3.6.1.4.1.22764.1.1.2.3.7.1.1ColumnplcNodeAdaptsStringBandIndexnot-accessiblecurrentThe band number on which the adapt values are defined.
1.3.6.1.4.1.22764.1.1.2.3.7.1.2ColumnplcNodeAdaptsStringBandread-onlycurrentThe adapt values of the 128 carriers of a band. The expected format is VALUE VALUE VALUE ... VALUE. Each value is two octets representing one adapt carrier lev…
1.3.6.1.4.1.22764.1.1.2.3.8TableplcNodeAdaptsTablenot-accessiblecurrentThis table contains adapt level configuration for each carrier of the node.
1.3.6.1.4.1.22764.1.1.2.3.8.1RowplcNodeAdaptsEntrynot-accessiblecurrentThis row contains adapt level values for a group of carriers. The group is defined by the couple (plcNodeAdaptsBandIndex,plcNodeAdaptsGroupIndex).
1.3.6.1.4.1.22764.1.1.2.3.8.1.1ColumnplcNodeAdaptsBandIndexnot-accessiblecurrentThe band number on which the adapt values are defined.
1.3.6.1.4.1.22764.1.1.2.3.8.1.2ColumnplcNodeAdaptsGroupIndexnot-accessiblecurrentThe group number on which the adapt values are defined.
1.3.6.1.4.1.22764.1.1.2.3.8.1.3ColumnplcNodeAdaptsCarrier1read-onlycurrentThe adapt level of the first carrier of the group.
1.3.6.1.4.1.22764.1.1.2.3.8.1.4ColumnplcNodeAdaptsCarrier2read-onlycurrentThe adapt level of the second carrier of the group.
1.3.6.1.4.1.22764.1.1.2.3.8.1.5ColumnplcNodeAdaptsCarrier3read-onlycurrentThe adapt level of the third carrier of the group.
1.3.6.1.4.1.22764.1.1.2.3.8.1.6ColumnplcNodeAdaptsCarrier4read-onlycurrentThe adapt level of the fourth carrier of the group.
1.3.6.1.4.1.22764.1.1.2.3.8.1.7ColumnplcNodeAdaptsCarrier5read-onlycurrentThe adapt level of the fifth carrier of the group.
1.3.6.1.4.1.22764.1.1.2.3.8.1.8ColumnplcNodeAdaptsCarrier6read-onlycurrentThe adapt level of the sixth carrier of the group.
1.3.6.1.4.1.22764.1.1.2.3.8.1.9ColumnplcNodeAdaptsCarrier7read-onlycurrentThe adapt level of the seventh carrier of the group.
1.3.6.1.4.1.22764.1.1.2.3.8.1.10ColumnplcNodeAdaptsCarrier8read-onlycurrentThe adapt level of the eighth carrier of the group.
1.3.6.1.4.1.22764.1.1.2.3.9NodeplcNodeAdaptsInput
1.3.6.1.4.1.22764.1.1.2.3.9.1ScalarplcNodeAdaptsInputBandread-writecurrentThe band number on which the adapt level value changes are requested.
1.3.6.1.4.1.22764.1.1.2.3.9.2ScalarplcNodeAdaptsInputGroupread-writecurrentThe group number on which the adapt level value changes are requested.
1.3.6.1.4.1.22764.1.1.2.3.9.3ScalarplcNodeAdaptsInputCarrier1read-writecurrentThe adapt level of the first carrier of the considered group of the chosen band.
1.3.6.1.4.1.22764.1.1.2.3.9.4ScalarplcNodeAdaptsInputCarrier2read-writecurrentThe adapt level of the second carrier of the considered group of the chosen band.
1.3.6.1.4.1.22764.1.1.2.3.9.5ScalarplcNodeAdaptsInputCarrier3read-writecurrentThe adapt level of the third carrier of the considered group of the chosen band.
1.3.6.1.4.1.22764.1.1.2.3.9.6ScalarplcNodeAdaptsInputCarrier4read-writecurrentThe adapt level of the fourth carrier of the considered group of the chosen band.
1.3.6.1.4.1.22764.1.1.2.3.9.7ScalarplcNodeAdaptsInputCarrier5read-writecurrentThe adapt level of the fifth carrier of the considered group of the chosen band.
1.3.6.1.4.1.22764.1.1.2.3.9.8ScalarplcNodeAdaptsInputCarrier6read-writecurrentThe adapt level of the sixth carrier of the considered group of the chosen band.
1.3.6.1.4.1.22764.1.1.2.3.9.9ScalarplcNodeAdaptsInputCarrier7read-writecurrentThe adapt level of the seventh carrier of the considered group of the chosen band.
1.3.6.1.4.1.22764.1.1.2.3.9.10ScalarplcNodeAdaptsInputCarrier8read-writecurrentThe adapt level of the eighth carrier of the considered group of the chosen band.
1.3.6.1.4.1.22764.1.1.2.3.9.11ScalarplcNodeAdaptsInputProceedread-writecurrentTrue to request a modification of the carrier adapt level associated to the considered group and band.
1.3.6.1.4.1.22764.1.1.2.3.9.12ScalarplcNodeAdaptsInputResultread-onlycurrentResult value of the requested node adapt level value changes.
1.3.6.1.4.1.22764.1.1.2.3.10TableplcNodeNetConfigTablenot-accessiblecurrentThis table contains ip and mac addresses of the node.
1.3.6.1.4.1.22764.1.1.2.3.10.1RowplcNodeNetConfigEntrynot-accessiblecurrentThis row contains ip and mac address used by an interface.
1.3.6.1.4.1.22764.1.1.2.3.10.1.1ColumnplcNodeIpAddrread-writecurrentThe IP address of the IP layer above the interface.
1.3.6.1.4.1.22764.1.1.2.3.10.1.2ColumnplcNodeNetMaskread-writecurrentThe IP Subnet mask of the IP layer above the interface.
1.3.6.1.4.1.22764.1.1.2.3.10.1.3ColumnplcNodeMacAddrread-writecurrentThe MAC address of the MAC layer above the interface.
1.3.6.1.4.1.22764.1.1.2.3.10.1.4ColumnplcNodeGatewayread-writecurrentThe Gateway address of the IP layer above the interface.
1.3.6.1.4.1.22764.1.1.2.3.11NodeplcNodeActions
1.3.6.1.4.1.22764.1.1.2.3.11.1NodeplcNodeActionsCommit
1.3.6.1.4.1.22764.1.1.2.3.11.1.1ScalarplcNodeActionsCommitProceedread-writecurrentTrue to request the commit of the configuration changes into the flash memory
1.3.6.1.4.1.22764.1.1.2.3.11.1.2ScalarplcNodeActionsCommitResultread-onlycurrentResult value of the requested flash commit operation.
1.3.6.1.4.1.22764.1.1.2.3.11.2NodeplcNodeActionsReset
1.3.6.1.4.1.22764.1.1.2.3.11.2.1ScalarplcNodeActionsResetProceedread-writecurrentTrue to request the reset of the node. This operation will terminate the communication between the manager and the node
1.3.6.1.4.1.22764.1.1.2.3.11.3NodeplcNodeActionsCarrier
1.3.6.1.4.1.22764.1.1.2.3.11.3.1ScalarplcNodeActionsCarrierFlatProceedread-writecurrentTrue to request the equipment to flat the signal
1.3.6.1.4.1.22764.1.1.2.4NodeplcSNAnalyser
1.3.6.1.4.1.22764.1.1.2.4.1ScalarplcSNAnalyserEnableread-writecurrenttrue if the modem should turn to spectrum analyser mode. In this mode the modem enters a receive only mode, and captures periodic samples of the signal on the …
1.3.6.1.4.1.22764.1.1.2.4.2TableplcSNAnalyserTablenot-accessiblecurrentThis table gathers all statistic data specific to SPC200 chip relative to plc analyser.
1.3.6.1.4.1.22764.1.1.2.4.2.1RowplcSNAnalyserEntrynot-accessiblecurrentThis row contains statistic data specific to SPC200 chip relative to a band.
1.3.6.1.4.1.22764.1.1.2.4.2.1.1ColumnplcSNAnalyserMinSignalread-onlycurrentMinimum signal measured over several samples for the associated carrier wave entry. The value is expressed in Glomer� which can be converted in dBm/Hz using …
1.3.6.1.4.1.22764.1.1.2.4.2.1.2ColumnplcSNAnalyserMaxSignalread-onlycurrentMaximum signal measured on several samples for the associated carrier wave entry. The value is expressed in Glomer� which can be converted in dBm/Hz using th…
1.3.6.1.4.1.22764.1.1.2.4.2.1.3ColumnplcSNAnalyserAvgSignalread-onlycurrentAverage signal measured on several samples for the associated carrier wave entry. The value is expressed in Glomer� which can be converted in dBm/Hz using th…
1.3.6.1.4.1.22764.1.1.2.4.2.1.4ColumnplcSNAnalyserLastSignalread-onlycurrentSignal measured for last sample on the associated carrier wave entry. The value is expressed in Glomer� which can be converted in dBm/Hz using the following …
1.3.6.1.4.1.22764.1.1.2.4.2.1.5ColumnplcSNAnalyserFFTDivread-onlycurrentFFT division factor on the associated band.
1.3.6.1.4.1.22764.1.1.2.4.3ScalarplcSNAnalyserAGCread-onlycurrentGain factor in dB, as used by the Automatic Gain Control last sample
1.3.6.1.4.1.22764.1.1.2.5NodeplcAGCAnalyser
1.3.6.1.4.1.22764.1.1.2.5.1ScalarplcAGCAnalyserEnableread-writecurrent
1.3.6.1.4.1.22764.1.1.2.5.2ScalarplcAGCAnalyserSamplesPart1read-onlycurrent
1.3.6.1.4.1.22764.1.1.2.5.3ScalarplcAGCAnalyserSamplesPart2read-onlycurrent
1.3.6.1.4.1.22764.1.1.2.6NodeplcBssId
1.3.6.1.4.1.22764.1.1.2.6.1ScalarplcMasterBssIdread-writecurrentThe value of the master Bss Id
1.3.6.1.4.1.22764.1.1.2.6.2ScalarplcSlaveBssIdread-writecurrentThe value of the slave Bss Id
1.3.6.1.4.1.22764.1.1.2.7NodeplcSpy
1.3.6.1.4.1.22764.1.1.2.7.1ScalarplcSpyIsDynamicread-writecurrentTrue to set the spy dynamic mode
1.3.6.1.4.1.22764.1.1.2.7.2ScalarplcStaticSpySynchBandNbread-writecurrentThe synchronization band number used for static spy mode
1.3.6.1.4.1.22764.1.1.3NodesoftwareMgnt
1.3.6.1.4.1.22764.1.1.3.1ScalarcurrentSoftwareVersionread-onlycurrentThe name of the current software release.
1.3.6.1.4.1.22764.1.1.3.2ScalarcurrentSoftwareBoardVersionread-onlycurrentThe name of the current software board release.
1.3.6.1.4.1.22764.1.1.3.3ScalarcurrentSoftwareAFEVersionread-onlycurrentThe name of the current software Analog Front End release.
1.3.6.1.4.1.22764.1.1.3.4TablesoftwareTablenot-accessiblecurrentThis table contains the current and reserve softwares of the node.
1.3.6.1.4.1.22764.1.1.3.4.1RowsoftwareEntrynot-accessiblecurrentThis row contains software information.
1.3.6.1.4.1.22764.1.1.3.4.1.1ColumnsoftwareIndexnot-accessiblecurrentThe index number of the software.
1.3.6.1.4.1.22764.1.1.3.4.1.2ColumnsoftwareVersionread-onlycurrentThe name of the software release.
1.3.6.1.4.1.22764.1.1.3.5NodesoftwareUpload
1.3.6.1.4.1.22764.1.1.3.5.1ScalarsoftwareUploadTFTPServerIPread-writecurrentThe IP address of the TFTP serveur
1.3.6.1.4.1.22764.1.1.3.5.2ScalarsoftwareUploadLoginread-writecurrentThe user login on the TFTP server
1.3.6.1.4.1.22764.1.1.3.5.3ScalarsoftwareUploadPasswordread-writecurrentThe user password on the TFTP server. Warning: This field is displayed using 6 * characters
1.3.6.1.4.1.22764.1.1.3.5.4ScalarsoftwareUploadFileNameread-writecurrentThe software file name to upload
1.3.6.1.4.1.22764.1.1.3.5.5ScalarsoftwareUploadProceedread-writecurrentTrue to request the uploading to start
1.3.6.1.4.1.22764.1.1.3.5.6ScalarsoftwareUploadResultread-onlycurrentResult value of the requested uploading
1.3.6.1.4.1.22764.1.1.3.5.7ScalarsoftwareUploadTFTPServerPortread-writecurrentThe service port of the TFTP server
1.3.6.1.4.1.22764.1.1.3.6NodesoftwareAction
1.3.6.1.4.1.22764.1.1.3.6.1ScalarsoftwareActionIndexread-writecurrentThe index of the reserve software
1.3.6.1.4.1.22764.1.1.3.6.2ScalarsoftwareActionTyperead-writecurrentType of the software action software: switch, remove
1.3.6.1.4.1.22764.1.1.3.6.3ScalarsoftwareActionProceedread-writecurrentTrue to request the switch between the current and the reserver software to start
1.3.6.1.4.1.22764.1.1.3.6.4ScalarsoftwareActionResultread-onlycurrentResult value of the requested action
1.3.6.1.4.1.22764.1.1.4NodeplcConformance
1.3.6.1.4.1.22764.1.1.4.1NodeplcCompliances
1.3.6.1.4.1.22764.1.1.4.1.1ComplianceplcCompliancecurrentThe compliance statement for SPC200 chip.
1.3.6.1.4.1.22764.1.1.4.2NodeplcGroups
1.3.6.1.4.1.22764.1.1.4.2.1GroupnodeGroupcurrentA collection of objects providing node configuration information.
1.3.6.1.4.1.22764.1.1.4.2.2GroupinputNodeGroupcurrentA collection of objects used to request node configuration information changes.
1.3.6.1.4.1.22764.1.1.4.2.3GrouptopologyGroupcurrentA collection of objects providing topology configuration.
1.3.6.1.4.1.22764.1.1.4.2.4GroupinputTopologyGroupcurrentA collection of objects used to request topology configuration changes.
1.3.6.1.4.1.22764.1.1.4.2.5GroupstatisticGroupcurrentA collection of objects providing statistic data on node and plc link performances.
1.3.6.1.4.1.22764.1.1.4.2.6GroupsoftwareGroupcurrentA collection of objects providing software management
1.3.6.1.4.1.22764.1.1.4.2.7GroupanalyserGroupcurrentA collection of objects providing spectrum analyser data
1.3.6.1.4.1.22764.1.1.4.3ComplianceagentCapabilitiesnot-implementedcurrentThe SPC200 chip SNMP agent capabilities
1.3.6.1.4.1.22764.1.4IdentityipExtcurrentExtended ip needed for SPiDCOM functionalities
1.3.6.1.4.1.22764.1.4.1ScalaripDynamicread-writecurrentTrue if Ip address is set dynamically
1.3.6.1.4.1.22764.1.4.2GroupipExtGroupcurrentThe fields needed by the SPiDCOM functionalities
Type Definitions
NameSyntaxStatusDescription
AdaptValueInteger32 ( 0 .. 8191 )currentThe adapt level integer value.
BandValueInteger32 ( 1 .. 7 )currentA channel is composed of 7 bands.
CarrierValueInteger32 ( 1 .. 8 )currentA group is composed of 8 carriers.
ChannelBandwidthValueInteger32currentThe channel bandwidth integer value.
EstimationModeINTEGER { automatic ( 1 ) , manual ( 2 ) }currentThe type of Channel estimation process. Two are available: - automatic, the equipment negociates the best configuration with the remote equipment, - manual, the operator defines the configuration.
GroupValueInteger32 ( 1 .. 16 )currentA band is composed of 16 groups.
ModulationValueINTEGER { none ( 1 ) , bpsk ( 2 ) , qpsk ( 3 ) , qam16 ( 4 ) , qam64 ( 5 ) , qam256 ( 6 ) }currentModulation amplitude used by a group of carriers.
PilotValueInteger32 ( 1 .. 128 )currentThe pilot carrier wave can be chosen between the carrier 1 up to carrier 128 inside a band carrier range.
PlcChannelTypeINTEGER { rx ( 1 ) , rxLast ( 2 ) , tx ( 3 ) }currentThe different type of plc channels: rx for the current reception channel, rx last for the last reception channel, tx for the current transmission channel.
PlcModeTypeINTEGER { ad-hoc ( 0 ) , slave ( 1 ) , master ( 2 ) }currentType of software management action.
ResultValueINTEGER { success ( 1 ) , fail ( 2 ) }currentResult value of input vectors.
SoftwareActionResultValueINTEGER { success ( 0 ) , on-going ( 1 ) , fileNotExist ( 2 ) , flashExhausted ( 3 ), flashCorrupted ( 4 ), notEnoughMemory ( 5 ), invalidParameter ( 6 ), genericError ( 7 ) }currentResult value of software action process.
SoftwareActionTypeINTEGER { switch ( 1 ) , remove ( 2 ) }currentType of software management action.
SoftwareIndexInteger32 ( 1 .. 10 )currentThe software index.