MIB Viewer

SSG-5000-CHASSIS-MIB

135 objects
This MIB provides a means to monitor the status of a SSG system's health.
Imported Objects
IF-MIBifIndex
SHASTA-MIBshastaExperiment
SNMPv2-CONFMODULE-COMPLIANCE OBJECT-GROUP
SNMPv2-SMICounter32 Counter64 Gauge32 Integer32 IpAddress MODULE-IDENTITY NOTIFICATION-TYPE OBJECT-TYPE
SNMPv2-TCDisplayString TEXTUAL-CONVENTION TruthValue
OIDNameAccessStatusDescription
1.3.6.1.4.1.3199.10.28Identityssg5000ChassisMIBThis MIB provides a means to monitor the status of a SSG system's health.
1.3.6.1.4.1.3199.10.28.1Nodessg5000ChassisMIBObjects
1.3.6.1.4.1.3199.10.28.1.1Nodessg5000ChassisGroup
1.3.6.1.4.1.3199.10.28.1.1.1Scalarssg5000SysStatusread-onlycurrentThis is a bitmask value that indicates the system alarms: Bit Alarm 1 NODE_DEAD_ALARM 2 NODE_REBOOT_ALARM 3 FAN_DEAD_ALARM 4 FAN_FAILURE_ALARM 5 OVERTEMP_ALARM…
1.3.6.1.4.1.3199.10.28.1.1.2Tablessg5000SlotTablenot-accessiblecurrentA list of slot entries.
1.3.6.1.4.1.3199.10.28.1.1.2.1Rowssg5000SlotEntrynot-accessiblecurrentEntry containing information about card status in a slot of the chassis. A slot could contain no card.
1.3.6.1.4.1.3199.10.28.1.1.2.1.1Columnssg5000SlotIndexread-onlycurrentUnique index for indexing the slots.
1.3.6.1.4.1.3199.10.28.1.1.2.1.2Columnssg5000SlotCardTyperead-onlycurrentThe type of card in the slot.
1.3.6.1.4.1.3199.10.28.1.1.2.1.3Columnssg5000SlotCardDescrread-onlycurrentA Description of the card in the slot.
1.3.6.1.4.1.3199.10.28.1.1.2.1.4Columnssg5000SlotAdminStatusread-onlycurrentThe Administrative status of the card.
1.3.6.1.4.1.3199.10.28.1.1.2.1.5Columnssg5000SlotOperStatusread-onlycurrentThe Operational status of the card.
1.3.6.1.4.1.3199.10.28.1.1.2.1.6Columnssg5000SlotCardNumPortsread-onlycurrentThe number of ports equipped in this card.
1.3.6.1.4.1.3199.10.28.1.1.2.1.7Columnssg5000SlotCardHwVersionread-onlycurrentThe hardware version fo the card.
1.3.6.1.4.1.3199.10.28.1.1.2.1.8Columnssg5000SlotCardSerialNumberread-onlycurrentThe serial number of the card.
1.3.6.1.4.1.3199.10.28.1.1.2.1.9Columnssg5000SlotAlarmsread-onlycurrentThe bitmask value that carry card's alarms, Bit Alarm 1 CARD_MISSING_ALARM 2 CARD_INSERTED_ALARM 3 CARD_REMOVED_ALARM 4 CARD_MISMATCH_ALARM 5 CARD_BOOT_ALARM 6…
1.3.6.1.4.1.3199.10.28.1.1.3Tablessg5000SSMStatTablenot-accessiblecurrentTable of SSM port statistics information.
1.3.6.1.4.1.3199.10.28.1.1.3.1Rowssg5000SSMStatEntrynot-accessiblecurrentAn entry in the table, containing information about a SSM port.
1.3.6.1.4.1.3199.10.28.1.1.3.1.1Columnssg5000SSMIndexread-onlycurrentAn arbitrary integer value to uniquely identify a SSM module/port entry in a SSC card.
1.3.6.1.4.1.3199.10.28.1.1.3.1.2Columnssg5000SSMAdminStatusread-onlycurrentA Administrative status of the SSM.
1.3.6.1.4.1.3199.10.28.1.1.3.1.3Columnssg5000SSMOperStatusread-onlycurrentA Operational status of the SSM.
1.3.6.1.4.1.3199.10.28.1.1.3.1.4Columnssg5000SSMCPUIdleTics5Secread-onlycurrentCPU Idle Tics over 5 seconds duration of the SSM.
1.3.6.1.4.1.3199.10.28.1.1.3.1.5Columnssg5000SSMCPUTics5Secread-onlycurrentCPU Tics over 5 seconds duration of the SSM.
1.3.6.1.4.1.3199.10.28.1.1.3.1.6Columnssg5000SSMCPUIdleTicsRebootread-onlycurrentCPU Idle Tics since reboot of the SSM.
1.3.6.1.4.1.3199.10.28.1.1.3.1.7Columnssg5000SSMCPUTicsRebootread-onlycurrentCPU Tics since reboot of the SSM.
1.3.6.1.4.1.3199.10.28.1.1.3.1.8Columnssg5000SSMCPUMemHeapFreeread-onlycurrentFree Memory in the Heap of the the SSM.
1.3.6.1.4.1.3199.10.28.1.1.3.1.9Columnssg5000SSMCPUMemHeapTotalread-onlycurrentTotal Memory in the Heap of the the SSM.
1.3.6.1.4.1.3199.10.28.1.1.3.1.10Columnssg5000SSMCPUMBufClusterFreeread-onlycurrentFree MBuf cluster in the CPU of the SSM.
1.3.6.1.4.1.3199.10.28.1.1.3.1.11Columnssg5000SSMCPUMBufClusterTotalread-onlycurrentTotal MBuf cluster in the CPU of the SSM.
1.3.6.1.4.1.3199.10.28.1.1.3.1.12Columnssg5000SSMActiveAccessConnread-onlycurrentNumber of Active Access connection on this SSM.
1.3.6.1.4.1.3199.10.28.1.1.3.1.13Columnssg5000SSMActiveSubscribersread-onlycurrentNumber of Active subscribers on this SSM.
1.3.6.1.4.1.3199.10.28.1.1.3.1.14Columnssg5000SSMPacketsDroppedread-onlycurrentNumber of packets been dropped from this SSM.
1.3.6.1.4.1.3199.10.28.1.1.3.1.15Columnssg5000SSMPacketsForwardedread-onlycurrentNumber of packets been forwarded from this SSM.
1.3.6.1.4.1.3199.10.28.1.1.3.1.16Columnssg5000SSMAlarmsread-onlycurrentThe bitmask value that carry SSM's alarms, Bit Alarm 1 SSM_FAILED_ALARM 2 SSM_RESET_ALARM 3 SSM_UP_ALARM 4 SSM_DIED_ALARM 5 SSM_DOWN_ALARM
1.3.6.1.4.1.3199.10.28.1.1.4Tablessg5000ALCPortStatTablenot-accessiblecurrentTable of port (ATM Line Card) statistics information, table will list instances of OC3, DS3/E3 not ETH, CT3
1.3.6.1.4.1.3199.10.28.1.1.4.1Rowssg5000ALCPortStatEntrynot-accessiblecurrentAn entry in the table, containing information about an ATM access or trunk port.
1.3.6.1.4.1.3199.10.28.1.1.4.1.1Columnssg5000ALCPortIndexread-onlycurrentThe ALC port index of an ALC card.
1.3.6.1.4.1.3199.10.28.1.1.4.1.2Columnssg5000ALCPortIfIndexread-onlycurrentThe MIBII ifIndex value assigned to this port.
1.3.6.1.4.1.3199.10.28.1.1.4.1.3Columnssg5000ALCPortAdminStatusread-onlycurrentThe Administrative status of the ALC port.
1.3.6.1.4.1.3199.10.28.1.1.4.1.4Columnssg5000ALCPortOperStatusread-onlycurrentThe Operational status of the ALC port.
1.3.6.1.4.1.3199.10.28.1.1.4.1.5Columnssg5000ALCPortActiveAccessConnread-onlycurrentThe Active Access connections on the ALC port.
1.3.6.1.4.1.3199.10.28.1.1.4.1.6Columnssg5000ALCPortActiveTrunkConnread-onlycurrentThe Active Trunk connections on the ALC port.
1.3.6.1.4.1.3199.10.28.1.1.4.1.7Columnssg5000ALCPortCellsReceivedread-onlycurrentThe ATM cells received on this ALC port.
1.3.6.1.4.1.3199.10.28.1.1.4.1.8Columnssg5000ALCPortCellsTransmittedread-onlycurrentThe ATM cells transmitted on this ALC port.
1.3.6.1.4.1.3199.10.28.1.1.4.1.9Columnssg5000ALCPortCellsDroppedread-onlycurrentThe ATM cells dropped on this ALC port.
1.3.6.1.4.1.3199.10.28.1.1.4.1.10Columnssg5000ALCPortAlarmsread-onlycurrentThe bitmask value that carry port's alarms, bitmap [32,... ,9,8,7,6,5,4,3,2,1], refer ALCPortAlarmType for ATM interface alarm acronyms. Bit Alarm 1 ALC_PORT_U…
1.3.6.1.4.1.3199.10.28.1.1.5Tablessg5000ETHPortStatTablenot-accessiblecurrentTable of ETH port information, table will list instances of ETH port.
1.3.6.1.4.1.3199.10.28.1.1.5.1Rowssg5000ETHPortStatEntrynot-accessiblecurrentAn entry in the table, containing information about an Ethernet port.
1.3.6.1.4.1.3199.10.28.1.1.5.1.1Columnssg5000ETHPortIndexread-onlycurrentThe ETH port index.
1.3.6.1.4.1.3199.10.28.1.1.5.1.2Columnssg5000ETHPortAdminStatusread-onlycurrentThe Administrative status of the ETH port.
1.3.6.1.4.1.3199.10.28.1.1.5.1.3Columnssg5000ETHPortOperStatusread-onlycurrentThe Operational status of the ETH port.
1.3.6.1.4.1.3199.10.28.1.1.5.1.4Columnssg5000ETHPortAlarmsread-onlycurrentThe bitmask value that ETH port's alarms, bitmap [32,... ,9,8,7,6,5,4,3,2,1], refer ETHPortAlarmType for alarm acronyms. Bit Alarm 1 ETH_LINK_DOWN_ALARM 2 ETH_…
1.3.6.1.4.1.3199.10.28.1.1.6Tablessg5000CT3PortStatTablenot-accessiblecurrentTable of CT3 port information, table will list instances of CT3 port.
1.3.6.1.4.1.3199.10.28.1.1.6.1Rowssg5000CT3PortStatEntrynot-accessiblecurrentAn entry in the table, containing information about an CT3 port.
1.3.6.1.4.1.3199.10.28.1.1.6.1.1Columnssg5000CT3PortIndexread-onlycurrentThe CT3 port index.
1.3.6.1.4.1.3199.10.28.1.1.6.1.2Columnssg5000CT3PortAdminStatusread-onlycurrentThe Administrative status of the CT3 port.
1.3.6.1.4.1.3199.10.28.1.1.6.1.3Columnssg5000CT3PortOperStatusread-onlycurrentThe Operational status of the CT3 port.
1.3.6.1.4.1.3199.10.28.1.1.6.1.4Columnssg5000CT3PortAlarmsread-onlycurrentThe bitmask value that CT3 port's alarms, bitmap [32,... ,9,8,7,6,5,4,3,2,1], refer CT3PortAlarmType for alarm acronyms. Bit Alarm 1 CT3_FAILED_ALARM 2 CT3_RES…
1.3.6.1.4.1.3199.10.28.1.2Nodessg5000SysHealthGroup
1.3.6.1.4.1.3199.10.28.1.2.1Scalarssg5000SysFanStatusread-onlycurrentStatus of fan.
1.3.6.1.4.1.3199.10.28.1.2.2Scalarssg5000SysTempStatusread-onlycurrentok(1): 10C <= temperature <= 40C overTemperature(2): temperature > 40C underTemperature(3): temperature < 10C.
1.3.6.1.4.1.3199.10.28.1.2.3Scalarssg5000SysFabricCellsDroppedread-onlycurrentNumber of ATM cells dropped at system fabric.
1.3.6.1.4.1.3199.10.28.1.2.4Scalarssg5000SysFabricMemUtilizationread-onlycurrentMemory utilization of system fabric.
1.3.6.1.4.1.3199.10.28.1.2.5Scalarssg5000SysActiveAccessConnread-onlycurrentNumber of active connections of access ports.
1.3.6.1.4.1.3199.10.28.1.2.6Scalarssg5000SysActiveTrunkConnread-onlycurrentNumber of active connections of trunk ports.
1.3.6.1.4.1.3199.10.28.1.2.7Scalarssg5000SysPacketsDroppedread-onlycurrentNumber of IP packets dropped of the system.
1.3.6.1.4.1.3199.10.28.1.2.8Scalarssg5000SysCellsDroppedread-onlycurrentNumber of ATM cells dropped of the system.
1.3.6.1.4.1.3199.10.28.1.2.9Scalarssg5000CmcCPUIdleTics5Secread-onlycurrentCMC's CPU Idle Tics over 5 seconds duration.
1.3.6.1.4.1.3199.10.28.1.2.10Scalarssg5000CmcCPUTotalTics5Secread-onlycurrentCMC's CPU Tics over 5 seconds duration.
1.3.6.1.4.1.3199.10.28.1.2.11Scalarssg5000CmcCPUIdleTicsRebootread-onlycurrentCMC's CPU Idle Tics since system reboot.
1.3.6.1.4.1.3199.10.28.1.2.12Scalarssg5000CmcCPUTotalTicsRebootread-onlycurrentCMC's CPU Tics since system reboot.
1.3.6.1.4.1.3199.10.28.1.2.13Scalarssg5000CmcCPUMemHeapFreeread-onlycurrentCMC's free memory Heap measurement.
1.3.6.1.4.1.3199.10.28.1.2.14Scalarssg5000CmcCPUMemHeapTotalread-onlycurrentCMC's total memory Heap measurement.
1.3.6.1.4.1.3199.10.28.1.2.15Scalarssg5000CmcCPUMBufClusterFreeread-onlycurrentCMC's free MBuf Cluster.
1.3.6.1.4.1.3199.10.28.1.2.16Scalarssg5000CmcCPUMBufClusterTotalread-onlycurrentCMC's total MBuf Cluster.
1.3.6.1.4.1.3199.10.28.1.2.17Scalarssg5000CmcCPUAverageLoadread-onlycurrentSystem CMC's average cpu load (%).
1.3.6.1.4.1.3199.10.28.1.2.18Scalarssg5000SspCPUnoEncryptionAverageLoadread-onlycurrentSystem SSPs with no Encryption average cpu load (%).
1.3.6.1.4.1.3199.10.28.1.2.19Scalarssg5000SspCPUwEncryptionAverageLoadread-onlycurrentSystem SSPs with Encryption average cpu load (%).
1.3.6.1.4.1.3199.10.28.1.3Nodessg5000TrapIndexGroup
1.3.6.1.4.1.3199.10.28.1.3.1Scalarssg5000TrapSystemAlarmIdnot-accessiblecurrentA trap ID object for system alarm.
1.3.6.1.4.1.3199.10.28.1.3.2Scalarssg5000TrapCardAlarmIdnot-accessiblecurrentA trap ID object for card alarm.
1.3.6.1.4.1.3199.10.28.1.3.3Scalarssg5000TrapALCPortAlarmIdnot-accessiblecurrentA trap ID object for (ALC) port alarm.
1.3.6.1.4.1.3199.10.28.1.3.4Scalarssg5000TrapSSMAlarmIdnot-accessiblecurrentA trap ID object for ssm alarm.
1.3.6.1.4.1.3199.10.28.1.3.5Scalarssg5000TrapSlotIdnot-accessiblecurrentA trap slot ID for slot number.
1.3.6.1.4.1.3199.10.28.1.3.6Scalarssg5000TrapCardTypenot-accessiblecurrentA trap card ID for slot card type.
1.3.6.1.4.1.3199.10.28.1.3.7Scalarssg5000TrapPortIdnot-accessiblecurrentA trap port ID for port number.
1.3.6.1.4.1.3199.10.28.1.3.8Scalarssg5000TrapOccurClearTagnot-accessiblecurrentA trap state indicating occur or clear.
1.3.6.1.4.1.3199.10.28.1.3.9Scalarssg5000TrapPVCAlarmIdnot-accessiblecurrentA trap connection alarm ID for PVC connection alarm.
1.3.6.1.4.1.3199.10.28.1.3.10Scalarssg5000TrapInterfaceNumbernot-accessiblecurrentA trap interface ID for connection alarm.
1.3.6.1.4.1.3199.10.28.1.3.11Scalarssg5000TrapVPINumbernot-accessiblecurrentA trap variable object for Connection VPI number.
1.3.6.1.4.1.3199.10.28.1.3.12Scalarssg5000TrapVCINumbernot-accessiblecurrentA trap variable object for Connection VCI number.
1.3.6.1.4.1.3199.10.28.1.3.13Scalarssg5000TrapCT3PortAlarmIdnot-accessiblecurrentA trap ID object for CT3 port alarm.
1.3.6.1.4.1.3199.10.28.1.3.14Scalarssg5000TrapETHPortAlarmIdnot-accessiblecurrentA trap ID object for ETH port alarm.
1.3.6.1.4.1.3199.10.28.1.3.15Scalarssg5000TrapSSGHostAddressnot-accessiblecurrentA trap ID object indicating the SSG this trap is origionated, this is needed and informational when the trap is forwarded by Nortel-Shasta's Service Creation S…
1.3.6.1.4.1.3199.10.28.1.3.16Scalarssg5000TrapCT3DS2AlarmIdnot-accessiblecurrentA trap ID object for CT3 DS2 alarm.
1.3.6.1.4.1.3199.10.28.1.3.17Scalarssg5000TrapCT3DS1AlarmIdnot-accessiblecurrentA trap ID object for CT3 DS1 alarm.
1.3.6.1.4.1.3199.10.28.1.3.18Scalarssg5000TrapDS2ChannelIdnot-accessiblecurrentA trap ID object for indicating a DS2 channel.
1.3.6.1.4.1.3199.10.28.1.3.19Scalarssg5000TrapDS1ChannelIdnot-accessiblecurrentA trap ID object for indicating a DS1 channel.
1.3.6.1.4.1.3199.10.28.1.3.20Scalarssg5000TrapServiceModuleAlarmnot-accessiblecurrentA trap object for showing a SSG Service Module.
1.3.6.1.4.1.3199.10.28.1.3.21Scalarssg5000TrapServiceAlarmSeveritynot-accessiblecurrentA trap object for indicating Service Alarm Severity.
1.3.6.1.4.1.3199.10.28.1.3.22Scalarssg5000TrapServiceAlarmDescriptionnot-accessiblecurrentA trap object for describing a Service Alarm.
1.3.6.1.4.1.3199.10.28.2Nodessg5000MIBNotificationPrefix
1.3.6.1.4.1.3199.10.28.2.0Nodessg5000MIBNotification
1.3.6.1.4.1.3199.10.28.2.0.1Notificationssg5000ChassisFailureNotificationcurrentThe notification signifies that the agent detects a change in the status of ps1, ps2, fan, chassis temperature.
1.3.6.1.4.1.3199.10.28.2.0.2Notificationssg5000SysAlarmNotificationcurrentThe notification signal the agenet detects an alarm status in the system.
1.3.6.1.4.1.3199.10.28.2.0.3Notificationssg5000CardAlarmNotificationcurrentThe notification signal the agenet detects an alarm status in the card.
1.3.6.1.4.1.3199.10.28.2.0.4Notificationssg5000PortAlarmNotificationcurrentThe notification signal the agenet detects an alarm status in the port.
1.3.6.1.4.1.3199.10.28.2.0.5Notificationssg5000SSMAlarmNotificationcurrentThe notification signal the agenet detects an alarm status in the SSM.
1.3.6.1.4.1.3199.10.28.2.0.6Notificationssg5000PVCAlarmNotificationcurrentThe notification signifies that the agenet detects an alarm status in a PVC.
1.3.6.1.4.1.3199.10.28.2.0.7Notificationssg5000CT3PortAlarmNotificationcurrentThe notification signal the agenet detects an alarm status in the CT3 port.
1.3.6.1.4.1.3199.10.28.2.0.8Notificationssg5000ETHPortAlarmNotificationcurrentThe notification signal the agenet detects an alarm status in the ETHERNET port.
1.3.6.1.4.1.3199.10.28.2.0.9Notificationssg5000CT3DS2AlarmNotificationcurrentThe notification signal the agenet detects an DS2 alarm status in the CT3 port.
1.3.6.1.4.1.3199.10.28.2.0.10Notificationssg5000CT3DS1AlarmNotificationcurrentThe notification signal the agenet detects an DS1 alarm status in the CT3 port.
1.3.6.1.4.1.3199.10.28.2.0.11Notificationssg5000ServiceAlarmNotificationcurrentThe notification signal the agenet detects an alarm in SSG Service related modules.
1.3.6.1.4.1.3199.10.28.3Nodessg5000ChassisMIBConformance
1.3.6.1.4.1.3199.10.28.3.1Nodessg5000ChassisMIBCompliances
1.3.6.1.4.1.3199.10.28.3.1.1Compliancessg5000ChassisMIBCompliancecurrentThe compliance statement for the SSG-5000, used in the CMC, which implements the SSG-5000 chassis MIB.
1.3.6.1.4.1.3199.10.28.3.2Nodessg5000ChassisMIBGroups
1.3.6.1.4.1.3199.10.28.3.2.1Groupssg5000ChassisMIBGroupcurrentA collection of objects providing SSG-5000 chassis information.
1.3.6.1.4.1.3199.10.28.3.2.2Groupssg5000SysHealthMIBGroupcurrentA collection of objects providing SSG-5000 health information.
Type Definitions
NameSyntaxStatusDescription
AdminStatusINTEGER { adminStateDisabled(0), adminStateEnabled(1), adminStateAbsent(2), adminStateStandby(3) }currentAdministrative status.
ALARMStateTypeINTEGER { alarmOccur(1), alarmClear(2) }currentAlarm state type, alarmClear is reverting this alarm's alarm state, alarmOccur normally indicate the alarm conditions, excepte events of nodeReboot, cardBoot, cardRebooted, cardInserted, alcPortUp, ssmUp, ct3Up.
ALCPortAlarmTypeINTEGER { portUp(1), portDown(2), portLoop(3), portLOS(4), portLOF(5), portLAIS(6), portLRDI(7), portLOP(8), portPAIS(9), portPRDI(10), portLCD(11) }currentPort alarm type, an id for port specific alarm, Up/Down, indicates port's operational state, following are acronyms for ATM interfaces, Loop: in loop back state, LOS: in Lost of Signal state, LOF: in Lost of Frame state…
CardAlarmTypeINTEGER { cardMissing(1), cardInserted(2), cardRemoved(3), cardMismatch(4), cardBoot(5), cardReboot(6), cardRevMismatch(7), cardFailed(8), cardMalfunction(9), cardFailDiag(10), cardDead(11), cardSwitchToActive(12), cardStandbyNotInRedundant(13) }currentCard alarm type, cardInserted is an positive event of card is up in service. cardSwitchToActive is a redundant card event, indicate the card by TrapSlotId is now in the active role. cardStandbyNotInRedundant is a redund…
CardTypeINTEGER { cardAbsent(0), controlManagementCard(1), subscriberServiceCard(2), switchFabricCard(3), oc3AtmLineCard(4), ds3AtmLineCard(5), hsiLineCard(6), e3AtmLineCard(7), oc12SAtmLineCard(8), oc12DAtmLineCard(9), cardTypeUnknown(10), ds3ChannelizedFrameCard(11), ethnetLineCard(12) }currentCard type
CT3DS1AlarmTypeINTEGER { ds1OOF(1), ds1AIS(2), ds1RAI(3) }currentChannelized CT3 DS1 channel alarm type
CT3DS2AlarmTypeINTEGER { ds2OOF(1), ds2AIS(2), ds2RAI(3) }currentChannelized CT3 DS2 channel alarm type
CT3PortAlarmTypeINTEGER { ct3Failed(1), ct3Reset(2), ct3Up(3), ct3Dead(4), ct3Down(5), ct3DS3LOS(6), ct3DS3OOF(7), ct3DS3AIS(8), ct3DS3FERF(9), ct3DS3RED(10) }currentChannelized DS3 port alarm type, ct3Up alarm clear previous alarms.
ETHPortAlarmTypeINTEGER { ethLinkDown(1) }currentETHERNET port alarm type
OperStatusINTEGER { operStateDown(0), operStateUP(1), operStateAbsent(2), operStateStandby(3) }currentOperational status.
PSOperStatusINTEGER { unknown(1), empty(2), ok(3), fault(4), partialFault(5), diagFault(6) }currentOperational status of an SSG-5000 chassis component. A partialFault(5) indicates a partial failure in redundant components. A fault(3) value indicates failure in non-redundant component or a total failure in redundant c…
PsTypeINTEGER { ac264(1), dc48V(2), empty(3) }currentPower Supply type
PVCAlarmTypeINTEGER { connectionDown(1) }currentPVC connection alarm type
ServiceAlarmSeverityTypeINTEGER { infomational(1), warning(2), critical(3) }currentService Level Alarm severity level type
SSMAlarmTypeINTEGER { ssmFailed(1), ssmReset(2), ssmUp(3), ssmDead(4), ssmDown(5) }currentSSM alarm type, ssmUp indicate SSM is Up and in service, which clear ssm existing alarms.
SystemAlarmTypeINTEGER { nodeDead(1), nodeReboot(2), fanDead(3), fanFailure(4), temperatureOverheat(5), dcPowerFailure(6), acDcShelfFailure(7), acDcShelfOverheat(8), batteryFailure(9), batteryOverheat(10), pcmciaCardInserted(11), pcmciaCardRemoved(12), sysSSMsAreUp(13) }currentSystem alarm type, nodeReboot is an informational event reported when the system is administratively rebooted by command. PCMCIA card inserted/removed events are only significant when user is doing software upgrade with…