MIB Viewer

SYNC-RESEARCH-MIB

1070 objects
No module-level DESCRIPTION found.
Imported Objects
RFC-1212OBJECT-TYPE
RFC-1215--syncResearch --FROM SYNC-RESEARCH-COMMUNITY-MIB TRAP-TYPE
RFC1155-SMI--internet --TimeTicks Counter enterprises enterprises Gauge IpAddress mgmt NetworkAddress
OIDNameAccessStatusDescription
1.3.6.1.4.1.485NodesyncResearch
1.3.6.1.4.1.485.1NodesyncResearchAgent
1.3.6.1.4.1.485.1.1NodesyncProducts
1.3.6.1.4.1.485.1.1.1Nodeboundary
1.3.6.1.4.1.485.1.1.1.1NodesyncCN2R2b
1.3.6.1.4.1.485.1.1.1.2NodesyncFN2R2b
1.3.6.1.4.1.485.1.1.1.3NodesyncCN4R2b
1.3.6.1.4.1.485.1.1.1.4NodesyncFN4R2b
1.3.6.1.4.1.485.1.1.1.5NodesyncQN4R2b
1.3.6.1.4.1.485.1.1.1.6NodesyncCN4R3b
1.3.6.1.4.1.485.1.1.1.7NodesyncFN4R3b
1.3.6.1.4.1.485.1.1.1.8NodesyncQN4R3b
1.3.6.1.4.1.485.1.1.1.9NodesyncCN4R4b
1.3.6.1.4.1.485.1.1.1.10NodesyncFN4R4b
1.3.6.1.4.1.485.1.1.1.11NodesyncQN4R4b
1.3.6.1.4.1.485.1.1.1.12NodesyncCN4R4bu
1.3.6.1.4.1.485.1.1.1.13NodesyncFN4R4bu
1.3.6.1.4.1.485.1.1.1.14NodesyncQN4R4bu
1.3.6.1.4.1.485.1.1.1.15NodesyncCN4R4du
1.3.6.1.4.1.485.1.1.1.16NodesyncFN4R4du
1.3.6.1.4.1.485.1.1.1.17NodesyncQN4R4du
1.3.6.1.4.1.485.1.1.1.18NodesyncCN2R2du
1.3.6.1.4.1.485.1.1.1.19NodesyncFN2R2du
1.3.6.1.4.1.485.1.1.1.20NodesyncCN3R4bu
1.3.6.1.4.1.485.1.1.1.21NodesyncFN3R4bu
1.3.6.1.4.1.485.1.1.1.22NodesyncCN3R4du
1.3.6.1.4.1.485.1.1.1.23NodesyncFN3R4du
1.3.6.1.4.1.485.1.1.1.24NodesyncCN4R5b
1.3.6.1.4.1.485.1.1.1.25NodesyncFN4R5b
1.3.6.1.4.1.485.1.1.1.26NodesyncQN4R5b
1.3.6.1.4.1.485.1.1.1.27NodesyncCN4R5bu
1.3.6.1.4.1.485.1.1.1.28NodesyncFN4R5bu
1.3.6.1.4.1.485.1.1.1.29NodesyncQN4R5bu
1.3.6.1.4.1.485.1.1.1.30NodesyncCN4R5du
1.3.6.1.4.1.485.1.1.1.31NodesyncFN4R5du
1.3.6.1.4.1.485.1.1.1.32NodesyncQN4R5du
1.3.6.1.4.1.485.1.1.1.33NodesyncFN5R5du
1.3.6.1.4.1.485.1.1.1.34NodesyncBC4R5b
1.3.6.1.4.1.485.1.1.1.35NodesyncBF4R5b
1.3.6.1.4.1.485.1.1.1.36NodesyncBF3R5b
1.3.6.1.4.1.485.1.1.1.37NodesyncBF5R5b
1.3.6.1.4.1.485.1.1.1.38NodesyncFN3R5du
1.3.6.1.4.1.485.1.1.1.39NodesyncCN3R5du
1.3.6.1.4.1.485.1.1.1.40NodesyncCN5R5du
1.3.6.1.4.1.485.1.1.1.41NodesyncBF3R5
1.3.6.1.4.1.485.1.1.1.42NodesyncBC3R5
1.3.6.1.4.1.485.1.1.1.43NodesyncBF4R5
1.3.6.1.4.1.485.1.1.1.44NodesyncBC4R5
1.3.6.1.4.1.485.1.1.1.45NodesyncBF5R5
1.3.6.1.4.1.485.1.1.1.46NodesyncBC5R5
1.3.6.1.4.1.485.1.1.2NodecentralSite
1.3.6.1.4.1.485.1.1.2.1NodesyncCN4R2c
1.3.6.1.4.1.485.1.1.2.2NodesyncFN4R2c
1.3.6.1.4.1.485.1.1.2.3NodesyncQN4R2c
1.3.6.1.4.1.485.1.1.2.4NodesyncCN4R3c
1.3.6.1.4.1.485.1.1.2.5NodesyncFN4R3c
1.3.6.1.4.1.485.1.1.2.6NodesyncQN4R3c
1.3.6.1.4.1.485.1.1.2.7NodesyncCN4R4u
1.3.6.1.4.1.485.1.1.2.8NodesyncFN4R4u
1.3.6.1.4.1.485.1.1.2.9NodesyncQN4R4u
1.3.6.1.4.1.485.1.2NodeoemProducts
1.3.6.1.4.1.485.1.2.1NodethreeCom
1.3.6.1.4.1.485.1.2.1.1NodelinkConverter
1.3.6.1.4.1.485.1.2.1.2NodelinkConverter2
1.3.6.1.4.1.485.1.2.1.3Nodelc2EN2port
1.3.6.1.4.1.485.1.2.1.4Nodelc2EN4port
1.3.6.1.4.1.485.1.2.1.5Nodelc2TR2port
1.3.6.1.4.1.485.1.2.1.6Nodelc2TR6port
1.3.6.1.4.1.485.1.2.2NodecableTron
1.3.6.1.4.1.485.1.2.2.1NodeoemSNACXR2C
1.3.6.1.4.1.485.1.2.2.2NodeoemSNACXR2W
1.3.6.1.4.1.485.1.2.2.3NodeoemSNACMR2C
1.3.6.1.4.1.485.1.2.2.4NodeoemSNACMR2W
1.3.6.1.4.1.485.1.2.2.5NodeoemSNACMIM2
1.3.6.1.4.1.485.1.2.2.6NodeoemSNACXR2Q
1.3.6.1.4.1.485.1.2.2.7NodeoemSNACMR2Q
1.3.6.1.4.1.485.1.2.2.8NodeoemSNACXR3C
1.3.6.1.4.1.485.1.2.2.9NodeoemSNACXR3W
1.3.6.1.4.1.485.1.2.2.10NodeoemSNACMR3C
1.3.6.1.4.1.485.1.2.2.11NodeoemSNACMR3W
1.3.6.1.4.1.485.1.2.2.12NodeoemSNACXR3Q
1.3.6.1.4.1.485.1.2.2.13NodeoemSNACMR3Q
1.3.6.1.4.1.485.1.2.2.14NodeoemSNACXR4C
1.3.6.1.4.1.485.1.2.2.15NodeoemSNACXR4W
1.3.6.1.4.1.485.1.2.2.16NodeoemSNACMR4C
1.3.6.1.4.1.485.1.2.2.17NodeoemSNACMR4W
1.3.6.1.4.1.485.1.2.2.18NodeoemSNACXR4Q
1.3.6.1.4.1.485.1.2.2.19NodeoemSNACMR4Q
1.3.6.1.4.1.485.1.2.3Nodechipcom
1.3.6.1.4.1.485.1.2.4Nodeibm
1.3.6.1.4.1.485.1.2.4.1Nodeoem2490R22F
1.3.6.1.4.1.485.1.2.4.2Nodeoem2490R22C
1.3.6.1.4.1.485.1.2.4.3Nodeoem22181FR4
1.3.6.1.4.1.485.1.2.4.4Nodeoem22181CR4
1.3.6.1.4.1.485.1.2.4.5Nodeoem22183FR4
1.3.6.1.4.1.485.1.2.4.6Nodeoem22183CR4
1.3.6.1.4.1.485.1.2.4.7Nodeoem22181FR5
1.3.6.1.4.1.485.1.2.4.8Nodeoem22181CR5
1.3.6.1.4.1.485.1.2.4.9Nodeoem22183FR5
1.3.6.1.4.1.485.1.2.4.10Nodeoem22183CR5
1.3.6.1.4.1.485.1.2.4.11Nodeoem22185FR5
1.3.6.1.4.1.485.1.2.4.12Nodeoem22185CR5
1.3.6.1.4.1.485.1.2.4.13Nodeoem22183BF5
1.3.6.1.4.1.485.1.2.4.14Nodeoem22183BC5
1.3.6.1.4.1.485.1.2.4.15Nodeoem22184BF5
1.3.6.1.4.1.485.1.2.4.16Nodeoem22184BC5
1.3.6.1.4.1.485.1.2.4.17Nodeoem22185BF5
1.3.6.1.4.1.485.1.2.4.18Nodeoem22185BC5
1.3.6.1.4.1.485.2NodesrCommTrapGroup
1.3.6.1.4.1.485.2.1ScalarcommCountread-onlymandatoryThe number of possible community name entries in the table.
1.3.6.1.4.1.485.2.2TablecommTablenot-accessiblemandatoryThis table houses the information for trivial authentication and sending traps.
1.3.6.1.4.1.485.2.2.1RowcommEntrynot-accessiblemandatoryEach entry contains a community name and access code for SNMP trivial authentication and enable/disable traps options, as well as network and physical addressi…
1.3.6.1.4.1.485.2.2.1.1ColumncommIndexread-onlymandatoryA unique value for each community entry. Its value ranges between 1 and commCount.
1.3.6.1.4.1.485.2.2.1.2ColumncommNameread-writemandatoryA community name that will be used to access MIB objects. Each community name is associated with an access code of either NO-ACCESS, RO, RW, or SU.
1.3.6.1.4.1.485.2.2.1.3ColumncommTrapread-writemandatoryThis object is checked to determine if traps should be sent to the corresponding network address associated with it.
1.3.6.1.4.1.485.2.2.1.4ColumncommIPAddrread-writemandatoryThe network address of the device that will receive traps from the agent. This IP address also qualifies who may use this community name to access MIB objects.…
1.3.6.1.4.1.485.2.2.1.5ColumncommMACAddrread-onlymandatoryThe physical address of the device receiving traps from the agent.
1.3.6.1.4.1.485.2.2.1.6ColumncommAccessread-writemandatoryAccess code assiciated with the community name of the same entry. noAccess indicates a community name with zero privileges. ro has read-only access to MIB obje…
1.3.6.1.4.1.485.3NodesrNodeGroup
1.3.6.1.4.1.485.3.1NodenodeUnitGroup
1.3.6.1.4.1.485.3.1.1NodeunitControlGroup
1.3.6.1.4.1.485.3.1.1.1ScalarunitRestartread-writemandatorySetting this variable to a value of 1 will force the unit to restart. Setting this variable to any other value will cause an SNMP error. This variable always r…
1.3.6.1.4.1.485.3.1.1.2ScalardumpOnRestartread-writemandatorySetting this variable to a value of 1 will force the unit to perform a dump on restart. Setting this variable to a value of 2 will force it to not to dump on r…
1.3.6.1.4.1.485.3.1.1.3ScalarinitiateInstallread-writemandatorySetting this variable to a value of 1 will force the unit to initiate an install process. This variable always returns a value of 2.
1.3.6.1.4.1.485.3.1.1.4ScalarinitializeStatsread-writemandatorySetting this variable to a value of 1 will force the unit to initialize (clear) SyncResearch proprietary statistics kept by the unit. This variable always retu…
1.3.6.1.4.1.485.3.1.1.5ScalarclearDumpread-writemandatorySetting this variable to a value of 1 will force the unit to clear a dump. This variable always returns a value of 2.
1.3.6.1.4.1.485.3.1.1.6ScalaracknowledgeAllStatusesread-writemandatoryThis field is used for consolidating status of the unit. When this field is set to yes, the unit will mark each of the various statuses in different levels as …
1.3.6.1.4.1.485.3.1.1.7ScalarconsolidatedUnitStatusread-onlymandatoryThis object reports the consolidted status of the unit. All acknowledged element statuses and any element statuses specified as ignored by the user are ignored…
1.3.6.1.4.1.485.3.1.1.8ScalarhomeDialBackupread-writemandatorySetting this variable to a value of 1 will force all dial backup lines to dedicated lines. Setting this variable to any other value will case an SNMP error. Th…
1.3.6.1.4.1.485.3.1.2NodeunitStatusGroup
1.3.6.1.4.1.485.3.1.2.1ScalarunitModelread-onlymandatoryThis variable defines the base hardware model of the unit.
1.3.6.1.4.1.485.3.1.2.2ScalarsoftwareVersionread-onlymandatoryThe current version number of the operating software in xx.yyy where xx = major release, yyy = revision.
1.3.6.1.4.1.485.3.1.2.3ScalarproductTyperead-onlymandatoryThe product type string returned is set in the MS.SYS file and defines the product name.
1.3.6.1.4.1.485.3.1.2.4ScalarmaxPortNumberread-onlymandatoryThe maximum number of ports this unit can support (total number of serial access ports plus total number of LAN ports).
1.3.6.1.4.1.485.3.1.2.5ScalarmaxPUread-onlymandatoryThe maximum number of PUs this unit can support (total number that can be configured).
1.3.6.1.4.1.485.3.1.2.6ScalarmaxSessionread-onlymandatoryThe maximum number of sessions this unit can support (total number that can be configured).
1.3.6.1.4.1.485.3.1.2.7ScalarmaxDeviceread-onlymandatoryThe maximum number of devices this unit can support (total number that can be configured).
1.3.6.1.4.1.485.3.1.2.8ScalarmsBoardTyperead-onlymandatoryIndicates the type of serial I/O ports on main board. It returns 1 if not expected.
1.3.6.1.4.1.485.3.1.2.9ScalarmsExtBoardTyperead-onlymandatoryIndicates the type of serial I/O ports on extension board. It returns 1 if not present.
1.3.6.1.4.1.485.3.1.2.10ScalardumpFileStatusread-onlymandatoryIndicates the presence of a dump file.
1.3.6.1.4.1.485.3.1.2.11ScalardumpFileNameread-onlymandatoryThe dump file name.
1.3.6.1.4.1.485.3.1.2.12ScalarunitSerialNumberread-onlymandatoryThe base unit serial number.
1.3.6.1.4.1.485.3.1.2.13ScalarexpansionSerialNumberread-onlymandatoryThe expansion board serial number.
1.3.6.1.4.1.485.3.1.2.14ScalarromVersionread-onlymandatoryThe ROM version number.
1.3.6.1.4.1.485.3.1.2.15ScalarprocessorTyperead-onlymandatoryThe base unit processor type.
1.3.6.1.4.1.485.3.1.2.16ScalarchassisSlotread-onlymandatoryIf the unit is a blade in a chassis, then this variable indicates the slot number. If not applicable, a value of 99 will be returned.
1.3.6.1.4.1.485.3.1.2.17ScalarlastTrapSeqNumberread-onlymandatoryThis entry contains the last sequence number of the last trap generated by the unit. When this value reaches its maximum, it then rolls back to 0.
1.3.6.1.4.1.485.3.1.2.18ScalarlastInstallErrCoderead-onlymandatoryThis entry contains the status of last install. If the last install was successful, 0 is returned, 9999 indicates installation is in progress, otherwise an err…
1.3.6.1.4.1.485.3.1.2.19ScalarunitPartNumberread-onlymandatoryThe base unit part number.
1.3.6.1.4.1.485.3.1.2.20ScalarexpansionPartNumberread-onlymandatoryThe expansion board part number.
1.3.6.1.4.1.485.3.1.2.21Scalarwan1BoardTyperead-onlymandatoryIndicates the type of serial I/O ports on extension board. It returns 1 if not present.
1.3.6.1.4.1.485.3.1.2.22Scalarwan2BoardTyperead-onlymandatoryIndicates the type of serial I/O ports on extension board. It returns 1 if not present.
1.3.6.1.4.1.485.3.1.2.23ScalarpatchIdread-onlymandatoryThe current patch identifier for the operating software. Either the three character Patch ID or 'None'
1.3.6.1.4.1.485.3.1.3NodeunitConfigGroup
1.3.6.1.4.1.485.3.1.3.1ScalarunitIdread-onlymandatoryThis is the unit id. It consists of a 1 to 8 octet right justified case-sensitive ASCII field which uniquely identifies the unit. This ID is displayed on the L…
1.3.6.1.4.1.485.3.1.3.2ScalarnmsSerialSpeedread-onlymandatoryThe async serial port speed for NMS console port. The speed is expressed in bits per second (i.e. 9.6 Kbps is represented as 96 decimal). Currently supported s…
1.3.6.1.4.1.485.3.1.3.3ScalarserialPortLogoffTimerread-onlymandatoryUnits are minutes. Default value is 0, indicating that no timer is active.
1.3.6.1.4.1.485.3.1.3.4ScalarcallRetryTimerread-onlymandatoryThe call retry timer (a.k.a Session Retry Timer). The number of seconds to wait before trying to retry a failed connection attempt. Currently supported values …
1.3.6.1.4.1.485.3.1.3.5Scalarpasswordread-writemandatoryThe unit's password. This field indicates the system password used to log into the unit for operating the NMS interface. This field is a one to eight byte case…
1.3.6.1.4.1.485.3.1.3.6ScalarconfigPasswordread-writemandatoryThe configuration password. This field indicates the password used to enter the configuration subsystem. This field is a one to eight byte case-sensitive left …
1.3.6.1.4.1.485.3.1.3.7ScalardateTimeFieldread-writemandatoryThe date and time. This field is stored as 6 bytes of BCD Data in the following order: Month: 0x01 - 0x12 Day: 0x01 - 0x31 Year: 0x00 - 0x99 Hour: 0x00 - 0x23 …
1.3.6.1.4.1.485.3.1.3.8ScalarconfigIdread-onlymandatoryThe configuration identifer. This field is the configuration ID assigned when a new configuration is activated. first time. It is assigned by the unit or a Syn…
1.3.6.1.4.1.485.3.1.3.9ScalarinternalMacAddressread-onlymandatoryEmbedded conversion node MAC address. Applicable to Frame Node only.
1.3.6.1.4.1.485.3.1.3.10ScalarinternalRingNumberread-onlymandatoryEmbedded conversion node ring number. This should be unique within the network. Applicable to Frame Node only.
1.3.6.1.4.1.485.3.1.3.11ScalarinternalBridgeNumberread-onlymandatoryEmbedded conversion node bridge number. This parameter is currently not used. Applicable to Frame Node only.
1.3.6.1.4.1.485.3.1.3.12ScalarinternalMacAddress2read-onlymandatoryOptional second embedded conversion node MAC address. Applicable to Frame Node only.
1.3.6.1.4.1.485.3.1.3.13ScalarinternalRingNumber2read-onlymandatoryOptional second embedded conversion node ring number. This should be unique within the network. Applicable to Frame Node only.
1.3.6.1.4.1.485.3.1.3.14ScalarassociatedPortNumber2read-onlymandatoryAssigns the physical port number corresponding to the virtual port that the second embedded conversion node is associated with. Applicable to Frame Node only.
1.3.6.1.4.1.485.3.1.3.15ScalarassociatedDLCI2read-onlymandatoryAssigns the Frame Relay PVC number corresponding to the virtual port that the second embedded conversion node is associated with. Applicable to Frame Node only.
1.3.6.1.4.1.485.3.1.3.16ScalarinternalMacAddress3read-onlymandatoryOptional third embedded conversion node MAC address. Applicable to Frame Node only.
1.3.6.1.4.1.485.3.1.3.17ScalarinternalRingNumber3read-onlymandatoryOptional third embedded conversion node ring number. This should be unique within the network. Applicable to Frame Node only.
1.3.6.1.4.1.485.3.1.3.18ScalarassociatedPortNumber3read-onlymandatoryAssigns the physical port number corresponding to the virtual port that the third embedded conversion node is associated with. Applicable to Frame Node only.
1.3.6.1.4.1.485.3.1.3.19ScalarassociatedDLCI3read-onlymandatoryAssigns the Frame Relay PVC number corresponding to the virtual port that the third embedded conversion node is associated with. Applicable to Frame Node only.
1.3.6.1.4.1.485.3.1.3.20ScalarinternalMacAddress4read-onlymandatoryOptional forth embedded conversion node MAC address. Applicable to Frame Node only.
1.3.6.1.4.1.485.3.1.3.21ScalarinternalRingNumber4read-onlymandatoryOptional forth embedded conversion node ring number. This should be unique within the network. Applicable to Frame Node only.
1.3.6.1.4.1.485.3.1.3.22ScalarassociatedPortNumber4read-onlymandatoryAssigns the physical port number corresponding to the virtual port that the forth embedded conversion node is associated with. Applicable to Frame Node only.
1.3.6.1.4.1.485.3.1.3.23ScalarassociatedDLCI4read-onlymandatoryAssigns the Frame Relay PVC number corresponding to the virtual port that the forth embedded conversion node is associated with. Applicable to Frame Node only.
1.3.6.1.4.1.485.3.1.3.24ScalaripInactivityTimerread-onlymandatoryThis timer is used for IP/SNMP over X25 support. It is the inactivity timer for an IP connection. If there is no activity for an IP session for the time this f…
1.3.6.1.4.1.485.3.1.3.25ScalarexcessBurstGovernorread-onlymandatoryThis parameter configuration determines whether the FrameNode should limit the throughput on a per PVC basis to the configured Excess Burst Size (in the excess…
1.3.6.1.4.1.485.3.1.3.26ScalarmeasurementPeriodread-onlymandatoryThis parameter specifies the time period for calculating Excess Burst for Frame Relay ports. The range of this parameter is 1 second to 5 seconds. Default is 1…
1.3.6.1.4.1.485.3.1.3.27ScalarmarkDEBitread-onlymandatoryThis parameter specifies whether the FrameNode marks frames with the DE bit. The range of this parameter is YES or NO. Default is YES. If the parameter is set …
1.3.6.1.4.1.485.3.1.4NodeunitStatisticsGroup
1.3.6.1.4.1.485.3.1.4.1ScalarnumberSamplesread-onlymandatoryThe number of internal system level samples performed. Samples are taken every 10th of a second.
1.3.6.1.4.1.485.3.1.4.2ScalarsystemBufferFreeCountsread-onlymandatoryThe average number of system buffers free in the system during the system sample period. The number of available buffers varies by system type and configuratio…
1.3.6.1.4.1.485.3.1.4.3ScalarcpuIdleSumCountsread-onlymandatoryThe main processor average idle sum count. This is the average number of times the idle counter was incremented over the sampling period divided by 1000. This …
1.3.6.1.4.1.485.3.2NodenodeNetViewPUGroup
1.3.6.1.4.1.485.3.2.1NodenetViewPUStatusGroup
1.3.6.1.4.1.485.3.2.1.1ScalarnetviewConnectionStatusread-onlymandatoryThe status of the Primary Netview Connection.
1.3.6.1.4.1.485.3.2.1.2ScalarnetviewLastClearCoderead-onlymandatoryA two octet field indicating the Last Clearing Cause and Diagnostic Field of the last failed primary NetView connection attempt (a.k.a. call attempt) or Netvie…
1.3.6.1.4.1.485.3.2.1.3ScalarnetviewAltConnectionStatusread-onlymandatoryThe status of the alternate Netview Connection
1.3.6.1.4.1.485.3.2.1.4ScalarnetviewAltLastClearCoderead-onlymandatoryA two octet field indicating the Last Clearing Cause and Diagnostic Field of the last failed alternate NetView connection attempt (a.k.a. call attempt) or Netv…
1.3.6.1.4.1.485.3.2.1.5ScalarnetviewConnectionAttemptCountread-onlymandatoryThe number of connection attempts performed on the Primary NetView PU. This count is set to zero at startup, and after every loss of an estabished session.
1.3.6.1.4.1.485.3.2.1.6ScalarnetviewAltConnectionAttemptCountread-onlymandatoryThe number of connection attempts performed on the Alternate NetView PU. This count is set to zero at startup, and after every loss of an estabished session.
1.3.6.1.4.1.485.3.2.1.7ScalarnetviewStatusIgnoredread-writemandatoryThis field is used for consolidating status of the unit. The status of this netview pu is not put into consideration when consolidating status of the unit if t…
1.3.6.1.4.1.485.3.2.1.8ScalarnetviewStatusAcknowledgedread-writemandatoryThis field is used for consolidating status of the unit. When this field is set to yes, the unit will re-consolidate its status without putting the status of t…
1.3.6.1.4.1.485.3.2.1.9ScalarnetviewAltStatusIgnoredread-writemandatoryThis field is used for consolidating status of the unit. The status of this netview pu is not put into consideration when consolidating status of the unit if t…
1.3.6.1.4.1.485.3.2.1.10ScalarnetviewAltStatusAcknowledgedread-writemandatoryThis field is used for consolidating status of the unit. When this field is set to yes, the unit will re-consolidate its status without putting the status of t…
1.3.6.1.4.1.485.3.2.2NodenetViewPUConfigGroup
1.3.6.1.4.1.485.3.2.2.1ScalarnetviewPUXIDread-onlymandatoryPrimary NetView PU XID. This field indicates the XID data to be sent to the host for establishing Netview Session. This field is a maximum four byte hexadecima…
1.3.6.1.4.1.485.3.2.2.2ScalaralternateNetviewPUXIDread-onlymandatoryAlternate NetView PU XID. This field indicates the XID data to be sent to the host for establishing Netview Session. This field is a maximum four byte hexadeci…
1.3.6.1.4.1.485.3.2.2.3ScalarnetviewConnectIDread-onlymandatoryThe primary NetView PU connection ID. The default value is 0.
1.3.6.1.4.1.485.3.2.2.4ScalaralternateNetviewConnectIDread-onlymandatoryThe alternate NetView PU connection ID. The default value is 0.
1.3.6.1.4.1.485.3.2.2.5ScalarnetviewSpecialConnectread-onlymandatoryThe primary NetView PU connection type. The default value is originate.
1.3.6.1.4.1.485.3.2.2.6ScalaralternateNetviewSpecialConnectread-onlymandatoryThe alternate NetView PU connection type. The default value is originate.
1.3.6.1.4.1.485.3.3NodenodeBridgeGroup
1.3.6.1.4.1.485.3.3.1NodebridgeConfigGroup
1.3.6.1.4.1.485.3.3.1.1ScalarbrEnableBridgingread-onlymandatoryThis flag indicates if bridging is to be performed on this unit. Applicable to Frame Nodes only. The default value for this field is 'No'
1.3.6.1.4.1.485.3.3.1.2ScalarbridgePriorityread-onlymandatorySometimes referred to as the ROOT id. Determines the priority component of the Bridge identifier used in determining the Root Bridge for a spanning tree networ…
1.3.6.1.4.1.485.3.3.1.3ScalarbrMaxAgeread-onlymandatoryThe time at which a configuration message is descarded. Units are in seconds. Default value is 10 seconds
1.3.6.1.4.1.485.3.3.1.4ScalarbrHelloTimerread-onlymandatoryThe time interval between issuing configuration messages. Units are seconds. Default value is 2 seconds
1.3.6.1.4.1.485.3.3.1.5ScalarbrFilterIPXread-onlymandatoryIf set to yes, all IPX frames are filtered (if bridge is enabled). Default is no.
1.3.6.1.4.1.485.3.3.1.6ScalarbrFilterIPread-onlymandatoryIf set to yes, all IP frames are filtered (if bridging is enabled). Default is no.
1.3.6.1.4.1.485.3.3.1.7ScalarbrFilterNetBIOSread-onlymandatoryIf set to yes, all NetBIOS frames are filtered (if bridging is enabled). Default is no.
1.3.6.1.4.1.485.3.3.1.8ScalarbrFilterLLC2read-onlymandatoryIf set to yes, all LAN attached SNA LLC2 frames are filtered (if bridging is enabled). Default is no.
1.3.6.1.4.1.485.3.3.1.9ScalarbrFilterSMANread-onlymandatoryIf set to yes, all SyncManager LLC2 frames are filtered (if bridging is enabled). Default is no.
1.3.6.1.4.1.485.3.3.1.10ScalarbrForwardOtherread-onlymandatoryIf set to yes, all other frames are forwarded (if bridging is enabled). Default is No.
1.3.6.1.4.1.485.3.3.1.11ScalarbrIPXtargetPortread-onlymandatoryIf IPX filtering is set to no, then this parameter defines a specific FR port to deliver IPX frames to. Used in conjunction with brIPXtargetDLCI. The valid ran…
1.3.6.1.4.1.485.3.3.1.12ScalarbrIPXtargetDLCIread-onlymandatoryIf IPX filtering is set to no, then this parameter defines a specific FR DLCI to deliver IPX frames to. Used in conjunction with brIPXtargetPort. If the value …
1.3.6.1.4.1.485.3.3.1.13ScalarbrIPtargetPortread-onlymandatoryIf IP filtering is set to no, then this parameter defines a specific FR port to deliver IP frames to. Used in conjunction with brIPtargetDLCI. The valid range …
1.3.6.1.4.1.485.3.3.1.14ScalarbrIPtargetDLCIread-onlymandatoryIf IP filtering is set to no, then this parameter defines a specific FR DLCI to deliver IP frames to. Used in conjunction with brIPtargetPort. If the value of …
1.3.6.1.4.1.485.3.3.1.15ScalarbrNetBIOStargetPortread-onlymandatoryIf NetBIOS filtering is set to no, then this parameter defines a specific FR port to deliver NetBIOS frames to. Used in conjunction with brNetBIOStargetDLCI. T…
1.3.6.1.4.1.485.3.3.1.16ScalarbrNetBIOStargetDLCIread-onlymandatoryIf NetBIOS filtering is set to no, then this parameter defines a specific FR DLCI to deliver NetBIOS frames to. Used in conjunction with brNetBIOStargetPort. I…
1.3.6.1.4.1.485.3.3.1.17ScalarbrLLC2targetPortread-onlymandatoryIf SNA LLC2 filtering is set to no, then this parameter defines a specific FR port to deliver LLC2 frames to. Used in conjunction with brLLC2targetDLCI. The va…
1.3.6.1.4.1.485.3.3.1.18ScalarbrLLC2targetDLCIread-onlymandatoryIf SNA LLC2 filtering is set to no, then this parameter defines a specific FR DLCI to deliver LLC2 frames to. Used in conjunction with brLLC2targetPort. If the…
1.3.6.1.4.1.485.3.3.1.19ScalarbrOthertargetPortread-onlymandatoryIf Other forwarding is set to yes, then this parameter defines a specific FR port to deliver Other frames to. Used in conjunction with brOthertargetDLCI. The v…
1.3.6.1.4.1.485.3.3.1.20ScalarbrOthertargetDLCIread-onlymandatoryIf Other forwarding is set to yes, then this parameter defines a specific FR DLCI to deliver Other frames to. Used in conjunction with brOthertargetPort. If th…
1.3.6.1.4.1.485.3.3.1.21ScalarbrSerialPriorityread-onlymandatoryThis parameter defines the transmit priority for Frame Relay of serial attached port traffic.
1.3.6.1.4.1.485.3.3.1.22ScalarbrTerminatedLLC2Priorityread-onlymandatoryThis parameter defines the transmit priority for Frame Relay of terminated LLC2 traffic.
1.3.6.1.4.1.485.3.3.1.23ScalarbrLLC2Priorityread-onlymandatoryThis parameter defines the transmit priority for Frame Relay of SNA LLC2 traffic.
1.3.6.1.4.1.485.3.3.1.24ScalarbrIPXPriorityread-onlymandatoryThis parameter defines the transmit priority for Frame Relay of IPX traffic.
1.3.6.1.4.1.485.3.3.1.25ScalarbrIPPriorityread-onlymandatoryThis parameter defines the transmit priority for Frame Relay of IP traffic.
1.3.6.1.4.1.485.3.3.1.26ScalarbrNetBIOSPriorityread-onlymandatoryThis parameter defines the transmit priority for Frame Relay of NetBIOS traffic.
1.3.6.1.4.1.485.3.3.1.27ScalarbrOtherPriorityread-onlymandatoryThis parameter defines the transmit priority for Frame Relay of other traffic.
1.3.6.1.4.1.485.3.3.1.28ScalarbrHighPriorityBandwidthread-onlymandatoryThis parameter defines the high priority bandwidth. The sum of high, medium, and low priority bandwidth cannot exceed 100. Default value is 40.
1.3.6.1.4.1.485.3.3.1.29ScalarbrMediumPriorityBandwidthread-onlymandatoryThis parameter defines the medium priority bandwidth. The sum of high, medium, and low priority bandwidth cannot exceed 100. Default value is 30.
1.3.6.1.4.1.485.3.3.1.30ScalarbrLowPriorityBandwidthread-onlymandatoryThis parameter defines the low priority bandwidth. The sum of high, medium, and low priority bandwidth cannot exceed 100. Default value is 20.
1.3.6.1.4.1.485.3.3.1.31ScalarbrDelayTimerread-onlymandatoryThis field, expressed in seconds, specifies the maximum number of seconds a bridge frame can live in the unit. If a bridge frame stays in the unit longer than …
1.3.6.1.4.1.485.3.3.1.32ScalarbrEnableIPXBridgingread-onlymandatoryThis flag indicates if IPX bridging is to be performed on this unit. Applicable to Frame Nodes only. The default value for this field is 'Yes'
1.3.6.1.4.1.485.3.3.1.33ScalarbrEnableIPBridgingread-onlymandatoryThis flag indicates if IP bridging is to be performed on this unit. Applicable to Frame Nodes only. The default value for this field is 'Yes'
1.3.6.1.4.1.485.3.3.1.34ScalarbrEnableNetBiosBridgingread-onlymandatoryThis flag indicates if NetBios bridging is to be performed on this unit. Applicable to Frame Nodes only. The default value for this field is 'Yes'
1.3.6.1.4.1.485.3.3.1.35ScalarbrEnableSNABridgingread-onlymandatoryThis flag indicates if SNA bridging is to be performed on this unit. Applicable to Frame Nodes only. The default value for this field is 'Yes'
1.3.6.1.4.1.485.3.3.1.36ScalarbrEnableSyncManBridgingread-onlymandatoryThis flag indicates if Sync/Man bridging is to be performed on this unit. Applicable to Frame Nodes only. The default value for this field is 'Yes'
1.3.6.1.4.1.485.3.3.1.37ScalarbrEnableOtherBridgingread-onlymandatoryThis flag indicates if any other traffic bridging is to be performed on this unit. Applicable to Frame Nodes only. The default value for this field is 'No'
1.3.6.1.4.1.485.3.3.2NodebridgeStatsGroup
1.3.6.1.4.1.485.3.3.2.1TableipxStatsTablenot-accessiblemandatoryA table for reporting statistics for bridging.
1.3.6.1.4.1.485.3.3.2.1.1RowipxStatsEntrynot-accessiblemandatoryAn entry consisting of IPX bridging statistics for each bridge port.
1.3.6.1.4.1.485.3.3.2.1.1.1ColumnipxStatsIndexread-onlymandatoryThe number that uniquely identifies this IPX bridge port.
1.3.6.1.4.1.485.3.3.2.1.1.2ColumnipxRipRcvdFwdIntervalread-onlymandatoryIdentifies the number of IPX RIP packets received on this port during the RIP forwarding interval. These packets were accepted by the port.
1.3.6.1.4.1.485.3.3.2.1.1.3ColumnipxRipRcvdFiltIntervalread-onlymandatoryIdentifies the number of IPX RIP packets received on this port during the RIP filtering interval. These packets were tossed by the port.
1.3.6.1.4.1.485.3.3.2.1.1.4ColumnipxSapRcvdFwdIntervalread-onlymandatoryIdentifies the number of IPX SAP packets received on this port during the SAP forwarding interval. These packets were accepted by the port.
1.3.6.1.4.1.485.3.3.2.1.1.5ColumnipxSapRcvdFiltIntervalread-onlymandatoryIdentifies the number of IPX SAP packets received on this port during the SAP filtering interval. These packets were tossed by the port.
1.3.6.1.4.1.485.3.4NodenodeLANGroup
1.3.6.1.4.1.485.3.4.1NodelanControlGroup
1.3.6.1.4.1.485.3.4.1.1TablelanControlTablenot-accessiblemandatoryA table for controlling LAN ports and obtaining information.
1.3.6.1.4.1.485.3.4.1.1.1RowlanControlEntrynot-accessiblemandatoryAn entry consisting of port information for a particular LAN port.
1.3.6.1.4.1.485.3.4.1.1.1.1ColumnlanControlIndexread-onlymandatoryThe number that uniquely identifies this LAN port. Currently only one LAN port per unit is supported.
1.3.6.1.4.1.485.3.4.1.1.1.2ColumnlanControlTyperead-onlymandatoryThe LAN type. Token-Ring ports run the IEEE 802.5 protocol. Ethernet-type run the IEEE 802.3 and Ethernet Version 2. Other LAN protocols may be added in the fu…
1.3.6.1.4.1.485.3.4.1.1.1.3ColumnlanStatusread-writemandatoryThe status of the port. To change status of a port an enable, enable all or disable may be set. Valid Return status are enable(d), disable(d), or failed. Comma…
1.3.6.1.4.1.485.3.4.1.1.1.4ColumnlanControlFailureCoderead-onlymandatoryThis entry contains the failure codes if the associated LAN interface is in the failed state.
1.3.6.1.4.1.485.3.4.1.1.1.5ColumnlanControlNAUNameread-onlymandatoryThe NAU name of this port. The default value for this field is all blank (filled with ASCII space 0x20 characters).
1.3.6.1.4.1.485.3.4.1.1.1.6ColumnlanStatusIgnoredread-writemandatoryThis field is used for consolidating status of the unit. The status of this LAN is not put into consideration when consolidating status of the unit if this fie…
1.3.6.1.4.1.485.3.4.1.1.1.7ColumnlanStatusAcknowledgedread-writemandatoryThis field is used for consolidating status of the unit. When this field is set to yes, the unit will re-consolidate its status without putting the status of t…
1.3.6.1.4.1.485.3.4.2NodelanTokenRingGroup
1.3.6.1.4.1.485.3.4.2.1TablelanPortTablenot-accessiblemandatoryA table of LAN information.
1.3.6.1.4.1.485.3.4.2.1.1RowlanPortEntrynot-accessiblemandatoryAn entry consisting of port information for a particular LAN port.
1.3.6.1.4.1.485.3.4.2.1.1.1ColumnlanPortIndexread-onlymandatoryThe port number that uniquely identifies this port. Currently only one LANtoken ring port per unit is supported.
1.3.6.1.4.1.485.3.4.2.1.1.2ColumnlanPortTyperead-onlymandatoryThe LAN port type.
1.3.6.1.4.1.485.3.4.2.1.1.3ColumnlanMACAddressread-onlymandatoryThe user configured LANtoken ring MAC address. If the address is set to 0 then the burned-in Address is used. This field contains a user configured address if …
1.3.6.1.4.1.485.3.4.2.1.1.4ColumnlanPROMMACAddressread-onlymandatoryThe burned in MAC address. This is the MAC address assigned by the factory when the unit is shipped. If the User configured address is set to 0, then this will…
1.3.6.1.4.1.485.3.4.2.1.1.5ColumnlanSpeedread-onlymandatoryThe LAN port speed in Megabits/second.
1.3.6.1.4.1.485.3.4.2.1.1.6ColumnlanT1Timerread-onlymandatoryThe default LLC T1 timer value in seconds. T1 should be greater than T2 and less than Ti. Currently supported values are 1 to 25 seconds. The default value for…
1.3.6.1.4.1.485.3.4.2.1.1.7ColumnlanT2Timerread-onlymandatoryThe default LLC T2 timer value in tenths of seconds. If configured for 0 then the T2 timer is disabled and an RR frame will be sent for every I frame received.…
1.3.6.1.4.1.485.3.4.2.1.1.8ColumnlanTiTimerread-onlymandatoryThe default LLC Ti (inactivity) timer value in seconds. Ti should be greater than T1. Currently supported values are 2 to 50 seconds. The default value for thi…
1.3.6.1.4.1.485.3.4.2.1.1.9ColumnlanRxWindowSizeread-onlymandatoryThe default LLC receive window (N3) size. Note that this is not the same receive window as defined in IEEE 802.2 LLC. This is N3 which is the number of I frame…
1.3.6.1.4.1.485.3.4.2.1.1.10ColumnlanTxWindowSizeread-onlymandatoryThe defalut LLC transmit window size. Current allowable values are 1-15. The default value for this field is 7.
1.3.6.1.4.1.485.3.4.2.1.1.11ColumnlanMaxRetriesread-onlymandatoryThe default LLC maximum number of retries (N2 value). Current allowable values are 1-99. The default value for this field is 3.
1.3.6.1.4.1.485.3.4.2.1.1.12ColumnlanRingNumberread-onlymandatory802.5 bridging parameter. This variable returns a value of 0, if it is not defined. This value is configured in hex from 0 to FFF. This value is not applicable…
1.3.6.1.4.1.485.3.4.2.1.1.13ColumnlanBridgeNumberread-onlymandatory802.5 bridging parameter. The default value for this field is 1. This value is not applicable to Ethernet.
1.3.6.1.4.1.485.3.4.2.1.1.14ColumnlanEthernetFrameFormatread-onlymandatoryThe Ethernet frame format used on this LAN. The default value for this field is 802.3. Not used if Token Ring, and 1 is returned.
1.3.6.1.4.1.485.3.4.2.1.1.15ColumnlanSendLocalTestread-onlymandatoryThis port's send local test option. Identifies whether a test frame should be sent on the local ring to discover a destination MAC address. If all destinations…
1.3.6.1.4.1.485.3.4.2.1.1.16ColumnlanBroadcastTyperead-onlymandatoryThis port's broadcast type. Not used if Ethernet. Types are: none, all-routes, and single-route. Identifies the form of a broadcast test frame sent to discover…
1.3.6.1.4.1.485.3.4.2.1.1.17ColumnlanIPAddressread-onlymandatoryThis is the IP Address of this interface.
1.3.6.1.4.1.485.3.4.2.1.1.18ColumnlanNetworkMaskread-onlymandatoryThis is the network mask to be used on this interface.
1.3.6.1.4.1.485.3.4.2.1.1.19ColumnlanDefaultGatewayread-onlymandatoryDefault gateway address to be used when sending responses on this interface.
1.3.6.1.4.1.485.3.4.2.1.1.20ColumnlanNAUNameread-onlymandatoryThe NAU name of this port. The default value for this field is all blank (filled with ASCII space 0x20 characters).
1.3.6.1.4.1.485.3.4.2.1.1.21ColumnlanInterfaceTyperead-onlymandatoryThis port's physical interface type. Only used if Ethernet. The default for this field is utp. Not used if Token Ring, and 1 is returned.
1.3.6.1.4.1.485.3.4.2.1.1.22ColumnlanIPEthernetFrameTyperead-onlymandatoryThe IP Ethernet frame format used on this LAN for IP frames. The default value for this field is 802.3. Not used if Token Ring, and 1 is returned.
1.3.6.1.4.1.485.3.4.2.1.1.23ColumnlanInitStateread-onlymandatoryThe initial state of the LAN port. If configured for 'in-service', then the LAN port will be brougt up automattically when the unit is powered up. If configure…
1.3.6.1.4.1.485.3.4.2.1.1.24ColumnlanSecondDefaultGatewayread-onlymandatorySecond Default gateway address to be used when sending responses on this interface.
1.3.6.1.4.1.485.3.4.2.1.1.25ColumnlanRIPUpdtTimerread-onlymandatoryDefines frequency at which the RIP packets are sent over this interface. The range of this parameter is from 10 seconds to 180 seconds. A value of 0 implies no…
1.3.6.1.4.1.485.3.4.2.1.1.26ColumnlanRIPAgeread-onlymandatoryDefines frequency at which the learned RIP entries are removed if not corresponding RIP update is received. The range of this parameter is from 40 seconds to 5…
1.3.6.1.4.1.485.3.4.2.1.1.27ColumnlanSAPUpdtTimerread-onlymandatoryDefines frequency at which the SAP packets are sent over this interface. The range of this parameter is from 10 seconds to 180 seconds. A value of 0 implies th…
1.3.6.1.4.1.485.3.4.2.1.1.28ColumnlanSAPAgeread-onlymandatoryDefines frequency at which the learned SAP entries are removed if not corresponding SAP update is received. The range of this parameter is from 40 seconds to 7…
1.3.6.1.4.1.485.3.4.2.1.1.29ColumnlanRSMread-onlymandatoryThe Routing Summary Information parameter indicates whether the routing summary information should be generated in the RIP on that interface. If RSM is set to …
1.3.6.1.4.1.485.3.5NodenodeLineGroup
1.3.6.1.4.1.485.3.5.1NodelineControlGroup
1.3.6.1.4.1.485.3.5.1.1TablelineControlTablenot-accessiblemandatoryA table for controlling lines and obtaining information.
1.3.6.1.4.1.485.3.5.1.1.1RowlineControlEntrynot-accessiblemandatoryAn entry consisting of port information for a particular port.
1.3.6.1.4.1.485.3.5.1.1.1.1ColumnlineControlIndexread-onlymandatoryThe port number that uniquely identifies this port.
1.3.6.1.4.1.485.3.5.1.1.1.2ColumnlineControlTyperead-onlymandatoryThe port type. TSDLC (Terminal SDLC) ports emulate a Host and poll the downstream PUs (e.g. 3274 or 3174 SDLC/SNA controllers). HSDLC ports (Host SDLC) ports e…
1.3.6.1.4.1.485.3.5.1.1.1.3ColumnlineStatusread-writemandatoryThe status of the port. To change status of a port an enable, enable all or disable may be set. Valid Return status are enable(d), disable(d), or failed. When …
1.3.6.1.4.1.485.3.5.1.1.1.4ColumnlineControlFailureCoderead-onlymandatoryThis entry contains the failure codes if the associated port interface is in the failed state.
1.3.6.1.4.1.485.3.5.1.1.1.5ColumnlineControlNAUNameread-onlymandatoryThe NAU name of this port. The default value for this field is all blank (filled with ASCII space 0x20 characters).
1.3.6.1.4.1.485.3.5.1.1.1.6ColumnlineStatusIgnoredread-writemandatoryThis field is used for consolidating status of the unit. The status of this line is not put into consideration when consolidating status of the unit if this fi…
1.3.6.1.4.1.485.3.5.1.1.1.7ColumnlineStatusAcknowledgedread-writemandatoryThis field is used for consolidating status of the unit. When this field is set to yes, the unit will re-consolidate its status without putting the status of t…
1.3.6.1.4.1.485.3.5.1.1.1.8ColumnloopbackTestread-writemandatoryLoopback Test can be supported on both DSU/CSU and ISDN. Loopback can be local, Network, or Remote. Local loopback means outgoing serial data is looped back to…
1.3.6.1.4.1.485.3.5.2NodelinePhysicalGroup
1.3.6.1.4.1.485.3.5.2.1TablelinePhysicalTablenot-accessiblemandatoryA table for obtaining physical signal status information.
1.3.6.1.4.1.485.3.5.2.1.1RowlinePhysicalEntrynot-accessiblemandatoryAn entry consisting of port information for a particular port.
1.3.6.1.4.1.485.3.5.2.1.1.1ColumnlinePhysicalIndexread-onlymandatoryThe port number that uniquely identifies this port.
1.3.6.1.4.1.485.3.5.2.1.1.2ColumnlinePhysicalTyperead-onlymandatoryThe port type. TSDLC (Terminal SDLC) ports emulate a Host and poll the downstream PUs (e.g. 3274 or 3174 SDLC/SNA controllers). HSDLC ports (Host SDLC) ports e…
1.3.6.1.4.1.485.3.5.2.1.1.3ColumnlineEIAStatusread-onlymandatoryA port's current control signal status. All SDLC ports have the ability to read the current status of RS-232 or equivalent control signals. The value returned …
1.3.6.1.4.1.485.3.5.2.1.1.4ColumnlineQualityFrameCountread-onlymandatoryThis entry contains the number of frames received. For every 255 incoming frames, a trap is generated by the unit if lineQualityCRCErrors or lineQualityAborts …
1.3.6.1.4.1.485.3.5.2.1.1.5ColumnlineQualityCRCErrorsread-onlymandatoryThis entry contains the number of frames with CRC errors. For every 255 incoming frames, a trap is generated by the unit if lineQualityCRCErrors or lineQuality…
1.3.6.1.4.1.485.3.5.2.1.1.6ColumnlineQualityAbortsread-onlymandatoryThis entry contains the number of aborts received. For every 255 incoming frames, a trap is generated by the unit if lineQualityCRCErrors or lineQualityAborts …
1.3.6.1.4.1.485.3.5.2.1.1.7ColumnlineInterfaceTyperead-onlymandatoryReport hardware Interface type of the line. For older systems, this interface is fixed per port. For universal ports, the Interface type if set via the cable.
1.3.6.1.4.1.485.3.5.2.1.1.8ColumnlineCableTyperead-onlymandatoryReturns not-applicable if the h/w does not support universal port configuration. Identifies the cable type connected to the port.
1.3.6.1.4.1.485.3.5.2.1.1.9ColumnlineSwitchedConnectionread-onlymandatoryIdentifies whether the line is connected over a switched backup facility or a dedicated facility to a frame relay network. This parameter is applicable to fram…
1.3.6.1.4.1.485.3.5.2.2NodeisdnControlGroup
1.3.6.1.4.1.485.3.5.2.2.1TableisdndeviceConfigTablenot-accessiblemandatoryA list of device entries.
1.3.6.1.4.1.485.3.5.2.2.1.1RowisdndeviceConfigEntrynot-accessiblemandatoryThis entry contains information about a given device. The entry is indexed by the port number, CU index, and device.
1.3.6.1.4.1.485.3.5.2.2.1.1.1ColumnisdnLineIndexread-onlymandatoryThe port number for which the ISDN line is configured (line level).
1.3.6.1.4.1.485.3.5.2.2.1.1.2ColumnserviceTyperead-onlymandatoryDefines the service type of the ISDN WAN port.
1.3.6.1.4.1.485.3.5.2.2.1.1.3ColumnisdnSpeedread-onlymandatoryThe ports speed in 100 bits per second. The default value is 56000 bits per second.
1.3.6.1.4.1.485.3.5.2.2.1.1.4ColumnconnectionTimeOutread-onlymandatoryDefines the time to wait after sensing disruption before declaring failure. The range is 0 to 255 seconds. The default value is 12 seconds.
1.3.6.1.4.1.485.3.5.2.2.1.1.5ColumnnosConnectAttemptsread-onlymandatoryDefines the number or re-dial attempts before fail to connect. The range is 0 to 255. The default value is 1.
1.3.6.1.4.1.485.3.5.2.2.1.1.6ColumnfarEndNumberTyperead-onlymandatoryOne byte field that defines the called number type.
1.3.6.1.4.1.485.3.5.2.2.1.1.7ColumnfarEndNumberPlanread-onlymandatoryOne byte field that defines the called number Plan.
1.3.6.1.4.1.485.3.5.2.2.1.1.8ColumnfarEndNumberread-onlymandatoryOne byte field that defines the called number.
1.3.6.1.4.1.485.3.5.2.2.1.1.9ColumnlocalNumberTyperead-onlymandatoryOne byte field that defines the local number type.
1.3.6.1.4.1.485.3.5.2.2.1.1.10ColumnlocalNumberPlanread-onlymandatoryOne byte field that defines the local number Plan.
1.3.6.1.4.1.485.3.5.2.2.1.1.11ColumnlocalNumberread-onlymandatoryOne byte field that defines the local number.
1.3.6.1.4.1.485.3.5.2.2.1.1.12Columnspidread-onlymandatorySPID is a zero-terminated ASCII string with a minium length of 0 and a maximum length of 20.
1.3.6.1.4.1.485.3.5.2.2.2TableisdndeviceStatsTablenot-accessiblemandatoryA list of device entries.
1.3.6.1.4.1.485.3.5.2.2.2.1RowisdndeviceStatsEntrynot-accessiblemandatoryThis entry contains information about a given device. The entry is indexed by the port number, CU index, and device.
1.3.6.1.4.1.485.3.5.2.2.2.1.1ColumnisdnIndexread-onlymandatoryThe port number for which the ISDN line is configured (line level).
1.3.6.1.4.1.485.3.5.2.2.2.1.2ColumnchannelIDread-onlymandatoryThe port number for which the ISDN line is configured (line level).
1.3.6.1.4.1.485.3.5.2.2.2.1.3ColumnkbytesTransmittedread-onlymandatoryThis entry contains the number of bytes transmited.
1.3.6.1.4.1.485.3.5.2.2.2.1.4ColumnkbytesReceivedread-onlymandatoryThis entry contains the number of bytes received.
1.3.6.1.4.1.485.3.5.2.2.2.1.5ColumnpacketsTransmittedread-onlymandatoryThis entry contains the number of packets transmited.
1.3.6.1.4.1.485.3.5.2.2.2.1.6ColumnpacketsReceivedread-onlymandatoryThis entry contains the number of packets received.
1.3.6.1.4.1.485.3.5.2.2.2.1.7ColumnisdnloopbackbytesTransmittedread-onlymandatoryThis entry contains the number of bytes transmited.
1.3.6.1.4.1.485.3.5.2.2.2.1.8ColumnisdnloopbackbytesReceivedread-onlymandatoryThis entry contains the number of bytes received.
1.3.6.1.4.1.485.3.5.2.2.2.1.9ColumnisdnCRCErrorsread-onlymandatoryThis entry contains the number of frames with CRC errors.
1.3.6.1.4.1.485.3.5.2.3NodedsucsuControlGroup
1.3.6.1.4.1.485.3.5.2.3.1TabledsucsudeviceConfigTablenot-accessiblemandatoryA list of device entries.
1.3.6.1.4.1.485.3.5.2.3.1.1RowdsucsudeviceConfigEntrynot-accessiblemandatoryThis entry contains information about a given device. The entry is indexed by the port number, CU index, and device.
1.3.6.1.4.1.485.3.5.2.3.1.1.1ColumndsucsuLineNumberread-onlymandatoryThe port number for which the DsuCsu line is configured (line level).
1.3.6.1.4.1.485.3.5.2.3.1.1.2ColumndsucsuTyperead-onlymandatoryDefines the service type of the DSU/CSU port.
1.3.6.1.4.1.485.3.5.2.3.1.1.3ColumndsucsuClockingread-onlymandatoryClocking source for this port. Setting 'internal' will cause the port to emulate a physical DCE, and setting external will cause the port to emulate a physical…
1.3.6.1.4.1.485.3.5.2.3.1.1.4ColumndsucsuSpeedread-onlymandatoryThe ports speed in 100 bits per second. The default value is 56000 bits per second.
1.3.6.1.4.1.485.3.5.2.3.2TabledsucsudeviceStatsTablenot-accessiblemandatoryA list of device entries.
1.3.6.1.4.1.485.3.5.2.3.2.1RowdsucsudeviceStatsEntrynot-accessiblemandatoryThis entry contains information about a given device. The entry is indexed by the port number, CU index, and device.
1.3.6.1.4.1.485.3.5.2.3.2.1.1ColumndsucsuLineread-onlymandatoryThe port number for which the DsuCsu line is configured (line level).
1.3.6.1.4.1.485.3.5.2.3.2.1.2ColumndsucsuloopbackbytesTransmittedread-onlymandatoryThis entry contains the number of bytes transmited.
1.3.6.1.4.1.485.3.5.2.3.2.1.3ColumndsucsuloopbackbytesReceivedread-onlymandatoryThis entry contains the number of bytes received.
1.3.6.1.4.1.485.3.5.3NodelineSDLCGroup
1.3.6.1.4.1.485.3.5.3.1TablesdlcConfigTablenot-accessiblemandatoryA table of SDLC information.
1.3.6.1.4.1.485.3.5.3.1.1RowsdlcConfigEntrynot-accessiblemandatoryAn entry consisting of port information for a particular SDLC port.
1.3.6.1.4.1.485.3.5.3.1.1.1ColumnsdlcConfigPortIndexread-onlymandatoryThe port number that uniquely identifies this port. Current supported SDLC numbers are 1-4.
1.3.6.1.4.1.485.3.5.3.1.1.2ColumnsdlcConfigTyperead-onlymandatoryThe port type. TSDLC (Terminal SDLC) ports emulate a Host and poll the downstream PUs (e.g. 3274 or 3174 SDLC/SNA controllers). HSDLC ports (Host SDLC) ports e…
1.3.6.1.4.1.485.3.5.3.1.1.3ColumnsdlcInitStateread-onlymandatoryThe initial state of the SDLC port. If configured for 'in-service', then the SDLC port will be brougt up automattically when the unit is powered up. If configu…
1.3.6.1.4.1.485.3.5.3.1.1.4ColumnsdlcCarrierread-onlymandatoryThis field indicates whether Carrier (a.k.a. CD or DCD, RS-232 pin 8) is constant or switched for DCE devices (internally clocked), or Request To Send (a.k.a. …
1.3.6.1.4.1.485.3.5.3.1.1.5ColumnsdlcClockingread-onlymandatoryClocking source for this port. Setting 'internal' will cause the port to emulate a physical DCE, and setting external will cause the port to emulate a physical…
1.3.6.1.4.1.485.3.5.3.1.1.6ColumnsdlcSpeedread-onlymandatoryThe ports speed in 100 bits per second. The default value is 9600 bits per second. Speeds higher than 19200 are not supported on RS-232 ports units (must be V.…
1.3.6.1.4.1.485.3.5.3.1.1.7ColumnsdlcPauseread-onlymandatoryThis parameter defines the amount of time between polls in 1/100 second (10 millisecond) intervals. If set to zero then the port will poll the PUs as fast as p…
1.3.6.1.4.1.485.3.5.3.1.1.8ColumnsdlcNRZIread-onlymandatoryThis parameter indicates whether the port is configured for NRZI (yes) or NRZ (no) bit encoding. The default value is 'No' (NRZ encoding selected).
1.3.6.1.4.1.485.3.5.3.1.1.9ColumnsdlcT1Timerread-onlymandatoryThe SDLC T1 timer value in 20ths of a second. The default value is 20 (1 second). This field is not applicable to Host ports. It returns a dummy value.
1.3.6.1.4.1.485.3.5.3.1.1.10ColumnsdlcSlowPollTimerread-onlymandatoryThe slow poll timer value in 20ths of a second. The slow poll timer is the amount of time to wait to contact (send SNRM) failed PUs. The default value for this…
1.3.6.1.4.1.485.3.5.3.1.1.11ColumnsdlcMaxRetriesread-onlymandatoryThe maximum number of retries (N2 value) before failing a PU. The default value for this field is 3. This field is not applicable to Host ports. It returns a d…
1.3.6.1.4.1.485.3.5.3.1.1.12ColumnsdlcNAUNameread-onlymandatoryThe NAU name of this port. The default value for this field is all blank (filled with ASCII space 0x20 characters).
1.3.6.1.4.1.485.3.5.3.1.1.13ColumnsdlcMultiFlagInsertionread-onlymandatoryThis parameter indicates whether the port is configured to send multiple interframe flags. The default value is 'No' (single flags).
1.3.6.1.4.1.485.3.5.3.1.1.14ColumnsdlcCTSread-onlymandatoryDefines whether CTS is an input signal used to determine the port status. This parameter is applicable if clocking is set to external. For internal clocking th…
1.3.6.1.4.1.485.3.5.3.1.1.15ColumnsdlcDCDread-onlymandatoryDefines whether DCD is required as input signal or ignored. This parameter is applicable if the clocking is set to external. For internal clocking the paramete…
1.3.6.1.4.1.485.3.5.3.1.1.16ColumnsdlcDSRread-onlymandatoryDefines whether DSR is required as input signal or ignored. This parameter is applicable if the clocking is set to external. For internal clocking the paramete…
1.3.6.1.4.1.485.3.5.3.1.1.17ColumnsdlcDTRread-onlymandatoryDefines whether DTR is required as input signal or ignored. This parameter is applicable if the clocking is set to internal. For external clocking the paramete…
1.3.6.1.4.1.485.3.5.3.1.1.18ColumnsdlcRTSread-onlymandatoryDefines whether RTS is an input signal to determine the port status. This parameter is applicable if the clocking is set to internal. For external clocking the…
1.3.6.1.4.1.485.3.5.3.1.1.19ColumnsdlcReturnClockread-onlymandatoryDefines whether Return Clock (SCTE) is available as input signal or ignored. This parameter is applicable if the clocking is set to internal. For external cloc…
1.3.6.1.4.1.485.3.5.3.2TablesdlcStatsTablenot-accessiblemandatoryA table of SDLC information.
1.3.6.1.4.1.485.3.5.3.2.1RowsdlcStatsEntrynot-accessiblemandatoryAn entry consisting of port information for a particular SDLC port.
1.3.6.1.4.1.485.3.5.3.2.1.1ColumnsdlcStatsPortIndexread-onlymandatoryThe port number that uniquely identifies this SDLC port. Current supported numbers on are 1-4.
1.3.6.1.4.1.485.3.5.3.2.1.2ColumnsdlcPortTyperead-onlymandatoryThe port type. TSDLC (Terminal SDLC) ports emulate a Host and poll the downstream PUs (e.g. 3274 or 3174 SDLC/SNA controllers). HSDLC ports (Host SDLC) ports e…
1.3.6.1.4.1.485.3.5.3.2.1.3ColumnsdlcInOctetsread-onlymandatoryThe number of bytes received.
1.3.6.1.4.1.485.3.5.3.2.1.4ColumnsdlcOutOctetsread-onlymandatoryThe number of bytes sent.
1.3.6.1.4.1.485.3.5.3.2.1.5ColumnsdlcInFramesread-onlymandatoryThe number of I-frames received.
1.3.6.1.4.1.485.3.5.3.2.1.6ColumnsdlcOutFramesread-onlymandatoryThe number of I-frames sent.
1.3.6.1.4.1.485.3.5.3.2.1.7ColumnsdlcOverrunsread-onlymandatoryThe number of overruns.
1.3.6.1.4.1.485.3.5.3.2.1.8ColumnsdlcCRCErrorsread-onlymandatoryThe number of CRC errors.
1.3.6.1.4.1.485.3.5.3.2.1.9ColumnsdlcRecvAbortsread-onlymandatoryThe number of aborts received.
1.3.6.1.4.1.485.3.5.3.2.1.10Columnsdlcpollrsptimeoutsread-onlymandatoryThe number of poll response timeouts.
1.3.6.1.4.1.485.3.5.3.2.1.11Columnsdlciframetransread-onlymandatoryThe number of i-frame re-transmissions.
1.3.6.1.4.1.485.3.5.4NodelineBisyncGroup
1.3.6.1.4.1.485.3.5.4.1TablebisyncConfigTablenot-accessiblemandatoryA table of Bisync port information.
1.3.6.1.4.1.485.3.5.4.1.1RowbisyncConfigEntrynot-accessiblemandatoryAn entry consisting of port information for a particular Bisync port.
1.3.6.1.4.1.485.3.5.4.1.1.1ColumnbisyncConfigPortIndexread-onlymandatoryThe port number that uniquely identifies this port. Current supported Bisync numbers are 1-4.
1.3.6.1.4.1.485.3.5.4.1.1.2ColumnbisyncConfigTyperead-onlymandatoryThe port type. TBSC (Terminal Bisync) ports emulate a Host and polls the downstream controllers). HBSC ports (Host Bisync) ports emulate a line with Terminal C…
1.3.6.1.4.1.485.3.5.4.1.1.3ColumnbisyncNAUNameread-onlymandatoryThe NAU name of this port. The default value for this field is all blank (filled with ASCII space 0x20 characters).
1.3.6.1.4.1.485.3.5.4.1.1.4ColumnbisyncInitStateread-onlymandatoryThe initial state of the Bisync port. If configured for 'in-service', then the Bisync port will be brougt up automattically when the unit is powered up. If con…
1.3.6.1.4.1.485.3.5.4.1.1.5ColumnbisyncCarrierread-onlymandatoryThis field indicates whether Carrier (a.k.a. CD or DCD, RS-232 pin 8) is constant or switched for DCE devices (internally clocked), or Request To Send (a.k.a. …
1.3.6.1.4.1.485.3.5.4.1.1.6ColumnbisyncClockingread-onlymandatoryClocking source for this port. Setting 'internal' will cause the port to emulate a physical DCE, and setting external will cause the port to emulate a physical…
1.3.6.1.4.1.485.3.5.4.1.1.7ColumnbisyncSpeedread-onlymandatoryThe ports speed in bits per second. The default value is 9600 bits per second. Speeds higher than 64000 are not supported.
1.3.6.1.4.1.485.3.5.4.1.1.8ColumnbisyncPauseread-onlymandatoryThis parameter defines the amount of time between polls in 1/100 second (10 millisecond) intervals. If set to zero then the port will poll the CUs as fast as p…
1.3.6.1.4.1.485.3.5.4.1.1.9ColumnbisyncReplyTimerread-onlymandatoryThe time to wait for a response in seconds. The default value for this field is 3 seconds.
1.3.6.1.4.1.485.3.5.4.1.1.10ColumnbisyncRetriesread-onlymandatoryThe maximum number of retries (N2 value) before failing a CU. The default value for this field is 5.
1.3.6.1.4.1.485.3.5.4.1.1.11ColumnbisyncSlowpollTimerread-onlymandatoryThe time to wait in seconds before attempting a slowpoll. The default value for this field is 30 seconds.
1.3.6.1.4.1.485.3.5.4.1.1.12ColumnbisyncSessTermread-onlymandatoryThe type of session termination used. Only applies to Host BSC ports.
1.3.6.1.4.1.485.3.5.4.1.1.13ColumnbisyncIBSread-onlymandatorySome of non IBM 3270 BSC controllers can not handle ESC character but IBM 3270 BSC implementation requires ESC character. A new configuration parameter for Ter…
1.3.6.1.4.1.485.3.5.4.1.1.14ColumnbisyncCTSread-onlymandatoryDefines whether CTS is an input signal used to determine the port status. This parameter is applicable if clocking is set to external. For internal clocking th…
1.3.6.1.4.1.485.3.5.4.1.1.15ColumnbisyncDCDread-onlymandatoryDefines whether DCD is required as input signal or ignored. This parameter is applicable if the clocking is set to external. For internal clocking the paramete…
1.3.6.1.4.1.485.3.5.4.1.1.16ColumnbisyncDSRread-onlymandatoryDefines whether DSR is required as input signal or ignored. This parameter is applicable if the clocking is set to external. For internal clocking the paramete…
1.3.6.1.4.1.485.3.5.4.1.1.17ColumnbisyncDTRread-onlymandatoryDefines whether DTR is required as input signal or ignored. This parameter is applicable if the clocking is set to internal. For external clocking the paramete…
1.3.6.1.4.1.485.3.5.4.1.1.18ColumnbisyncRTSread-onlymandatoryDefines whether RTS is an input signal to determine the port status. This parameter is applicable if the clocking is set to internal. For external clocking the…
1.3.6.1.4.1.485.3.5.4.1.1.19ColumnbisyncReturnClockread-onlymandatoryDefines whether Return Clock (SCTE) is available as input signal or ignored. This parameter is applicable if the clocking is set to internal. For external cloc…
1.3.6.1.4.1.485.3.5.4.2TablebisyncStatsTablenot-accessiblemandatoryA table of Bisync information.
1.3.6.1.4.1.485.3.5.4.2.1RowbisyncStatsEntrynot-accessiblemandatoryAn entry consisting of port information for a particular Bisync port.
1.3.6.1.4.1.485.3.5.4.2.1.1ColumnbisyncStatsPortIndexread-onlymandatoryThe port number that uniquely identifies this Bisync port. Current supported numbers are 1-4.
1.3.6.1.4.1.485.3.5.4.2.1.2ColumnbisyncPortTyperead-onlymandatoryThe port type. TBSC (Terminal Bisync) ports emulate a Host and poll the downstream controllers). HBSC ports (Host Bisync) ports emulate a line with Terminal Co…
1.3.6.1.4.1.485.3.5.4.2.1.3ColumnbisyncInOctetsread-onlymandatoryThe number of bytes received.
1.3.6.1.4.1.485.3.5.4.2.1.4ColumnbisyncOutOctetsread-onlymandatoryThe number of bytes sent.
1.3.6.1.4.1.485.3.5.4.2.1.5ColumnbisyncOverrunsread-onlymandatoryThe number of receiver overruns.
1.3.6.1.4.1.485.3.5.4.2.1.6ColumnbisyncCRCErrorsread-onlymandatoryThe number of receive frame CRC errors.
1.3.6.1.4.1.485.3.5.4.2.1.7ColumnbisyncRcvTimeoutread-onlymandatoryThe number of receive timeout.
1.3.6.1.4.1.485.3.5.4.2.1.8ColumnbisyncXmtTimeoutread-onlymandatoryThe number of transmit timeout.
1.3.6.1.4.1.485.3.5.5NodelineFrameRelayGroup
1.3.6.1.4.1.485.3.5.5.1TableframeRelayConfigTablenot-accessiblemandatoryA table of Sync product Frame Relay information.
1.3.6.1.4.1.485.3.5.5.1.1RowframeRelayConfigEntrynot-accessiblemandatoryAn entry consisting of port information for a particular Sync product Frame Relay port.
1.3.6.1.4.1.485.3.5.5.1.1.1ColumnframeRelayConfigPortIndexread-onlymandatoryThe port number that uniquely identifies this port.
1.3.6.1.4.1.485.3.5.5.1.1.2ColumnframeRelayPortTyperead-onlymandatoryThe Frame Relay port type.
1.3.6.1.4.1.485.3.5.5.1.1.3ColumnframeRelayInitStateread-onlymandatoryThe initial state of the Frame Relay port. If configured for 'in-service', then the Frame Relay port will be brougt up automatically when the unit is powered u…
1.3.6.1.4.1.485.3.5.5.1.1.4ColumnframeRelayClockingread-onlymandatoryClocking source for this port. Setting 'internal' will cause the port to emulate a physical DCE, and setting external will cause the port to emulate a physical…
1.3.6.1.4.1.485.3.5.5.1.1.5ColumnframeRelaySpeedread-onlymandatoryThe ports speed in bits per second. The default value is 9600 bits per second. Speeds higher than 19200 are not supported on RS-232 port Sync products (must be…
1.3.6.1.4.1.485.3.5.5.1.1.6ColumnframeRelayLocalManagementProtocolread-onlymandatoryThe ports management protocol type. Annex D = ANSI T1.617 Annex D LMI = Frame Relay Manufacturers LMI The default value is Annex D.
1.3.6.1.4.1.485.3.5.5.1.1.7ColumnframeRelayLinkPollingTimerread-onlymandatoryMeasured in seconds, intervals of 5 T391 - Annex D nT1 - LMI The default value for this field is 5 seconds.
1.3.6.1.4.1.485.3.5.5.1.1.8ColumnframeRelayFullStatusPollingCountread-onlymandatoryThe number of polls that a full status poll is issued. N391 - Annex D nT1 - LMI The default value for this field is 6.
1.3.6.1.4.1.485.3.5.5.1.1.9ColumnframeRelayT1Timerread-onlymandatoryThe default LLC T1 timer value in seconds. T1 should be greater than T2 and less than Ti. Currently supported values are 1 to 25 seconds. The default value for…
1.3.6.1.4.1.485.3.5.5.1.1.10ColumnframeRelayT2Timerread-onlymandatoryThe default LLC T2 timer value in tenths of seconds. If configured for 0 then the T2 timer is disabled and an RR frame will be sent for every I frame received.…
1.3.6.1.4.1.485.3.5.5.1.1.11ColumnframeRelayTiTimerread-onlymandatoryThe default LLC Ti (inactivity) timer value in seconds. Ti should be greater than T1. Currently supported values are 2 to 50 seconds. The default value for thi…
1.3.6.1.4.1.485.3.5.5.1.1.12ColumnframeRelayRxWindowSizeread-onlymandatoryThe default LLC receive window (N3) size. Note that this is not the same receive window as defined in IEEE 802.2 LLC. This is N3 which is the number of I frame…
1.3.6.1.4.1.485.3.5.5.1.1.13ColumnframeRelayTxWindowSizeread-onlymandatoryThe defalut LLC transmit window size. Current allowable values are 1-7. The default value for this field is 7.
1.3.6.1.4.1.485.3.5.5.1.1.14ColumnframeRelayMaxRetriesread-onlymandatoryThe default LLC maximum number of retries (N2 value). The default value for this field is 15.
1.3.6.1.4.1.485.3.5.5.1.1.15ColumnframeRelayNAUNameread-onlymandatoryThe NAU name of this port. The default value for this field is all blank (filled with ASCII space 0x20 characters).
1.3.6.1.4.1.485.3.5.5.1.1.16ColumnframeRelayVirtualMACAddressread-onlymandatoryThe F/R WAN is treated as a token ring. This address is used for communication with other bridges in the network.
1.3.6.1.4.1.485.3.5.5.1.1.17ColumnframeRelayVirtualRingNumberread-onlymandatoryThe F/R WAN is treated as a token ring. This is the ring number for the F/R network to which the port is attached. It must be a unique ring number in the netwo…
1.3.6.1.4.1.485.3.5.5.1.1.18ColumnframeRelayVirtualBridgeNumberread-onlymandatoryThe F/R WAN is treated as a token ring. This variable only has significance if more than 1 F/R port is configured. The default value for this field is 1.
1.3.6.1.4.1.485.3.5.5.1.1.19ColumnframeRelayIPAddressread-onlymandatoryThis is the IP Address of this interface.
1.3.6.1.4.1.485.3.5.5.1.1.20ColumnframeRelayNetworkMaskread-onlymandatoryThis is the network mask to be used on this interface.
1.3.6.1.4.1.485.3.5.5.1.1.21ColumnframeRelayDefaultGatewayAddressread-onlymandatoryDefault gateway address to be used when sending responses on this interface.
1.3.6.1.4.1.485.3.5.5.1.1.22ColumnframeRelaySessSwitchThresholdread-onlymandatoryDescribes the session switch threshold for a session to switch between eVR and pVR. The value represents the LLC time-out occurrence for any session on this po…
1.3.6.1.4.1.485.3.5.5.1.1.23ColumnframeRelaySwitchedBackupread-onlymandatoryDefines the switched backup protocol used for dial backup. The range of this parameter is NONE or RACAL DTR-initiated. The default value is NONE.
1.3.6.1.4.1.485.3.5.5.1.1.24ColumnframeRelaySwitchedLineWaitTimerread-onlymandatoryThis parameter defines the maximum amount of time the FrameNode waits for the DAP to establish a dial connection before switching back to the dedicated line. T…
1.3.6.1.4.1.485.3.5.5.1.1.25ColumnframeRelayDedLineWaitTimerread-onlymandatoryThe FCC regulation for Autodialers requires that an Autodialer waits between successive dial operations. This parameter satisfies the FCC requirements. It cont…
1.3.6.1.4.1.485.3.5.5.1.1.26ColumnframeRelayCommittedBurstread-writemandatoryThis parameter specifies the maximum number of bits, during time interval Tc, the network agrees to accept under normal conditions. This parameter must match t…
1.3.6.1.4.1.485.3.5.5.1.1.27ColumnframeRelayExcessBurstread-writemandatoryThis is the maximum number of uncommitted bits, during time interval Tc, the network accepts above the committed burst size Bc. When the Excess burst Governor …
1.3.6.1.4.1.485.3.5.5.1.1.28ColumnframeRelayBridgingProtocolread-writemandatoryThis parameter specifies the bridging protocol to be used over Frame Relay link. This parameter has no effect if bridging is not turned on. The range of this p…
1.3.6.1.4.1.485.3.5.5.1.1.29ColumnframeRelayProxyARPread-writemandatoryThis parameter defines whether PROXY ARP is enabled for F/R attached devices or not. Range of this parameter is ENABLED or DISABLED. The value is 'DISABLED'.
1.3.6.1.4.1.485.3.5.5.1.1.30ColumnframeRelaySecondDefaultGatewayAddressread-onlymandatorySecond Default gateway address to be used when sending responses on this interface.
1.3.6.1.4.1.485.3.5.5.1.1.31ColumnframeRelayAlternateIPAddressread-onlymandatoryThis is the Alternate IP Address for single port dial up connection.
1.3.6.1.4.1.485.3.5.5.1.1.32ColumnframeRelayAlternateNetmaskread-onlymandatoryThis is the Alternate network mask for IP for single port dial up connecton.
1.3.6.1.4.1.485.3.5.5.1.1.33ColumnframeRelayLLC2FrameFormatread-writemandatoryThis parameter specifies the LLC2 frame format to be used over Frame Relay link. The range of this parameter is Token Ring, Ethernet Version 2, IEEE 802.3 or A…
1.3.6.1.4.1.485.3.5.5.1.1.34ColumnframeRelayMultiflagSeparationread-writemandatoryThis parameter specifies whether the unit will insert more than one flag between frames. The range of this parameter is yes and no. The value is 'no'.
1.3.6.1.4.1.485.3.5.5.1.1.35ColumnframeRelayRestrictTerminateSessUsageread-writemandatoryThis parameter specifies whether terminated sessions are to follow spanning tree states or not over Frame Relay Link. The range of this parameter is No and Spa…
1.3.6.1.4.1.485.3.5.5.1.1.36ColumnframeRelayRIPUpdtTimerread-onlymandatoryDefines frequency at which the RIP packets are sent over this interface. The range of this parameter is from 10 seconds to 180 seconds. A value of 0 implies no…
1.3.6.1.4.1.485.3.5.5.1.1.37ColumnframeRelayRIPAgeread-onlymandatoryDefines frequency at which the learned RIP entries are removed if not corresponding RIP update is received. The range of this parameter is from 40 seconds to 5…
1.3.6.1.4.1.485.3.5.5.1.1.38ColumnframeRelaySAPUpdtTimerread-onlymandatoryDefines frequency at which the SAP packets are sent over this interface. The range of this parameter is from 10 seconds to 180 seconds. A value of 0 implies th…
1.3.6.1.4.1.485.3.5.5.1.1.39ColumnframeRelaySAPAgeread-onlymandatoryDefines frequency at which the learned SAP entries are removed if not corresponding SAP update is received. The range of this parameter is from 40 seconds to 7…
1.3.6.1.4.1.485.3.5.5.1.1.40ColumnframeRelayRSMread-onlymandatoryThe Routing Summary Information parameter indicates whether the routing summary information should be generated in the RIP on that interface. If RSM is set to …
1.3.6.1.4.1.485.3.5.5.1.1.41ColumnframeRelayARPread-onlymandatoryThe ARP parameter indicates what format of ARP should be generated. Default value is 'Auto'
1.3.6.1.4.1.485.3.5.5.1.1.42ColumnframeRelayCTSread-onlymandatoryDefines whether CTS is an input signal used to determine the port status. This parameter is applicable if clocking is set to external. For internal clocking th…
1.3.6.1.4.1.485.3.5.5.1.1.43ColumnframeRelayDCDread-onlymandatoryDefines whether DCD is required as input signal or ignored. This parameter is applicable if the clocking is set to external. For internal clocking the paramete…
1.3.6.1.4.1.485.3.5.5.1.1.44ColumnframeRelayDSRread-onlymandatoryDefines whether DSR is required as input signal or ignored. This parameter is applicable if the clocking is set to external. For internal clocking the paramete…
1.3.6.1.4.1.485.3.5.5.1.1.45ColumnframeRelayDTRread-onlymandatoryDefines whether DTR is required as input signal or ignored. This parameter is applicable if the clocking is set to internal. For external clocking the paramete…
1.3.6.1.4.1.485.3.5.5.1.1.46ColumnframeRelayRTSread-onlymandatoryDefines whether RTS is an input signal to determine the port status. This parameter is applicable if the clocking is set to internal. For external clocking the…
1.3.6.1.4.1.485.3.5.5.1.1.47ColumnframeRelayReturnClockread-onlymandatoryDefines whether Return Clock (SCTE) is available as input signal or ignored. This parameter is applicable if the clocking is set to internal. For external cloc…
1.3.6.1.4.1.485.3.5.5.2TableframeRelayStatsTablenot-accessiblemandatoryA table of Frame Relay information.
1.3.6.1.4.1.485.3.5.5.2.1RowframeRelayStatsEntrynot-accessiblemandatoryAn entry consisting of port information for a particular Frame Relay port.
1.3.6.1.4.1.485.3.5.5.2.1.1ColumnframeRelayStatsPortIndexread-onlymandatoryThe port number that uniquely identifies this Frame Relay port.
1.3.6.1.4.1.485.3.5.5.2.1.2ColumnframeRelayInOctetsread-onlymandatoryThe number of bytes received inclusive of all valid bytes in the frame relay frame except for the CRC field (frame relay header included).
1.3.6.1.4.1.485.3.5.5.2.1.3ColumnframeRelayOutOctetsread-onlymandatoryThe number of bytes transmitted inclusive of all bytes in the frame relay frame except for the CRC field (frame relay header included).
1.3.6.1.4.1.485.3.5.5.2.1.4ColumnframeRelaySampleDurationread-onlymandatoryThe sample duration in seconds for Frame Relay Statistics for this port.
1.3.6.1.4.1.485.3.5.5.2.1.5ColumnframeRelayOverrunsread-onlymandatoryThe number of receiver overruns.
1.3.6.1.4.1.485.3.5.5.2.1.6ColumnframeRelayCRCErrorsread-onlymandatoryThe number of received CRC errors.
1.3.6.1.4.1.485.3.5.5.2.1.7ColumnframeRelayRecvAbortsread-onlymandatoryThe number of received frame aborts received.
1.3.6.1.4.1.485.3.5.5.2.1.8ColumnframeRelayTxDeread-onlymandatoryTotal number of frames sent with the DE bit.
1.3.6.1.4.1.485.3.5.5.2.1.9ColumnframeRelayRxDeread-onlymandatoryTotal number of frames received with the DE bit.
1.3.6.1.4.1.485.3.5.5.2.1.10ColumnframeRelaySwitchedAttemptsread-onlymandatoryThe total number of times a switched backup is attempted.
1.3.6.1.4.1.485.3.5.5.2.1.11ColumnframeRelaySwitchedAttemptsSuccessfulread-onlymandatoryThe total number of times switched backup attempts were successful.
1.3.6.1.4.1.485.3.5.6NodelineAsyncGroup
1.3.6.1.4.1.485.3.5.6.1TableasyncConfigTablenot-accessiblemandatoryA table of Async port information.
1.3.6.1.4.1.485.3.5.6.1.1RowasyncConfigEntrynot-accessiblemandatoryAn entry consisting of port information for a particular async port.
1.3.6.1.4.1.485.3.5.6.1.1.1ColumnasyncConfigPortIndexread-onlymandatoryThe port number that uniquely identifies this port.
1.3.6.1.4.1.485.3.5.6.1.1.2ColumnasyncConfigTyperead-onlymandatoryThe port type. HASC (Host Async) ports are for attaching to an Async Alarm Central Processor. TASC ports (Terminal Async) ports are for attaching to Alarm Cont…
1.3.6.1.4.1.485.3.5.6.1.1.3ColumnasyncNAUNameread-onlymandatoryThe NAU name of this port. The default value for this field is all blank (filled with ASCII space 0x20 characters).
1.3.6.1.4.1.485.3.5.6.1.1.4ColumnasyncInitStateread-onlymandatoryThe initial state of the async port. If configured for 'in-service', then the Async port will be brougt up automattically when the unit is powered up. If confi…
1.3.6.1.4.1.485.3.5.6.1.1.5ColumnasyncCarrierread-onlymandatoryThis field indicates whether Carrier (a.k.a. CD or DCD, RS-232 pin 8) is constant or switched for DCE devices (internally clocked), or Request To Send (a.k.a. …
1.3.6.1.4.1.485.3.5.6.1.1.6ColumnasyncSpeedread-onlymandatoryThe ports speed in bits per second. The default value is 300 bits per second. Speeds higher than 19200 are not supported.
1.3.6.1.4.1.485.3.5.6.1.1.7ColumnasyncPhysicalTyperead-onlymandatoryPhysical RS-232 type emulated by the port. The default value is 2 or DCE.
1.3.6.1.4.1.485.3.5.6.1.1.8ColumnasyncStopBitsread-onlymandatoryNumber of stop bits generated for transmit characters (received characters may have any number of bits regardless of the configuration). The default value is 1.
1.3.6.1.4.1.485.3.5.6.1.1.9ColumnasyncParityread-onlymandatoryParity type generated for transmit characters and checked for receive characters. If ODD or EVEN, then if a character is received with invalid parity, it is di…
1.3.6.1.4.1.485.3.5.6.1.1.10ColumnasyncDataBitsread-onlymandatoryNumber of data bits (not including the parity bit). The default value is 8.
1.3.6.1.4.1.485.3.5.6.1.1.11ColumnasyncIdleTimerread-onlymandatoryThe idle timer is amount of time (in milliseconds) used to determine when a complete message has been received from the line. If configured as 0, then this tim…
1.3.6.1.4.1.485.3.5.6.1.1.12ColumnasyncTxFrameGapread-onlymandatoryThe TX frame gap is analogous to the idle timer, but is used to separate messages received from the network by gaps in time so that the Async device can distin…
1.3.6.1.4.1.485.3.5.6.1.1.13ColumnasyncRxForwardingCountread-onlymandatoryThe Async receive forwarding count is used to forward messages when a configured number of characters is received from the Async line. This must be configured …
1.3.6.1.4.1.485.3.5.6.1.1.14ColumnasyncEiaSignalForwardingread-onlymandatoryThe Async EIA signal forwarding is used to cause receive data to be forwarding based on a change of EIA RS-232 control signals. If configured as a DCE, and thi…
1.3.6.1.4.1.485.3.5.6.1.1.15ColumnasyncAddressOffsetread-onlymandatoryIf the address offset is specified as zero, then the data is not parsed to find a device address in order to direct the data to a specified LLC connection. If …
1.3.6.1.4.1.485.3.5.6.1.1.16ColumnasyncRTCread-onlymandatoryDefines whether the alarms system protocol has a record termination(forwarding character). The valid range is from hex 01 to hex ff. The default value is not d…
1.3.6.1.4.1.485.3.5.6.1.1.17ColumnasyncCTSread-onlymandatoryDefines whether CTS is an input signal used to determine the port status. This parameter is applicable if clocking is set to external. For internal clocking th…
1.3.6.1.4.1.485.3.5.6.1.1.18ColumnasyncDCDread-onlymandatoryDefines whether DCD is required as input signal or ignored. This parameter is applicable if the clocking is set to external. For internal clocking the paramete…
1.3.6.1.4.1.485.3.5.6.1.1.19ColumnasyncDSRread-onlymandatoryDefines whether DSR is required as input signal or ignored. This parameter is applicable if the clocking is set to external. For internal clocking the paramete…
1.3.6.1.4.1.485.3.5.6.1.1.20ColumnasyncDTRread-onlymandatoryDefines whether DTR is required as input signal or ignored. This parameter is applicable if the clocking is set to internal. For external clocking the paramete…
1.3.6.1.4.1.485.3.5.6.1.1.21ColumnasyncRTSread-onlymandatoryDefines whether RTS is an input signal to determine the port status. This parameter is applicable if the clocking is set to internal. For external clocking the…
1.3.6.1.4.1.485.3.5.6.1.1.22ColumnasyncReturnClockread-onlymandatoryDefines whether Return Clock (SCTE) is available as input signal or ignored. This parameter is applicable if the clocking is set to internal. For external cloc…
1.3.6.1.4.1.485.3.5.6.1.1.23ColumnasyncOrtread-onlymandatoryThe ORT command is a new port level command. By default, the setting will be YES to set the N2 value to zero, but can be set to NO to indicate that the normal …
1.3.6.1.4.1.485.3.5.6.2TableasyncStatsTablenot-accessiblemandatoryA table of Async information.
1.3.6.1.4.1.485.3.5.6.2.1RowasyncStatsEntrynot-accessiblemandatoryAn entry consisting of port information for a particular Async port.
1.3.6.1.4.1.485.3.5.6.2.1.1ColumnasyncStatsPortIndexread-onlymandatoryThe port number that uniquely identifies this Async port.
1.3.6.1.4.1.485.3.5.6.2.1.2ColumnasyncPortTyperead-onlymandatoryThe port type. HASC (Host Async) ports are for attaching to an Async Alarm Central Processor. TASC ports (Terminal Async) ports are for attaching to Alarm Cont…
1.3.6.1.4.1.485.3.5.6.2.1.3ColumnasyncInOctetsread-onlymandatoryThe number of bytes received.
1.3.6.1.4.1.485.3.5.6.2.1.4ColumnasyncOutOctetsread-onlymandatoryThe number of bytes sent.
1.3.6.1.4.1.485.3.5.6.2.1.5ColumnasyncInMessagesread-onlymandatoryThe number of messages received.
1.3.6.1.4.1.485.3.5.6.2.1.6ColumnasyncOutMessagesread-onlymandatoryThe number of messages sent.
1.3.6.1.4.1.485.3.5.6.2.1.7ColumnasyncInMsgDiscardedread-onlymandatoryThe number of received messages discarded.
1.3.6.1.4.1.485.3.5.6.2.1.8ColumnasyncOutMsgDiscardedread-onlymandatoryThe number of sent messages discarded.
1.3.6.1.4.1.485.3.5.6.2.1.9ColumnasyncXmtFailuresread-onlymandatoryThe number of failures in transmission.
1.3.6.1.4.1.485.3.5.6.2.1.10ColumnasyncRcvMsgForwardedread-onlymandatoryThe number of received messages forwarded.
1.3.6.1.4.1.485.3.5.6.2.1.11ColumnasyncRcvMsgErrorsread-onlymandatoryThe number of errors detected in receiving messages.
1.3.6.1.4.1.485.3.5.6.2.1.12ColumnasyncRcvCharsDiscardedread-onlymandatoryThe number of received characters discarded.
1.3.6.1.4.1.485.3.5.6.2.1.13ColumnasyncRcvParityErrorsread-onlymandatoryThe number of parity errors detected.
1.3.6.1.4.1.485.3.5.6.2.1.14ColumnasyncRcvFramingErrorsread-onlymandatoryThe number of errors detected in receiving frames.
1.3.6.1.4.1.485.3.5.6.2.1.15ColumnasyncRcvFifoOverrunsread-onlymandatoryThe number FIFO receive overruns detected.
1.3.6.1.4.1.485.3.5.6.2.1.16ColumnasyncRcvCharsOverrunsread-onlymandatoryThe number of character receive overruns detected.
1.3.6.1.4.1.485.3.5.6.2.1.17ColumnasyncRcvBreakConditionsread-onlymandatoryThe number of receive break conditions.
1.3.6.1.4.1.485.3.5.7NodelineBisyncRjeGroup
1.3.6.1.4.1.485.3.5.7.1TablebisyncrjeConfigTablenot-accessiblemandatoryA table of Bisync port information.
1.3.6.1.4.1.485.3.5.7.1.1RowbisyncrjeConfigEntrynot-accessiblemandatoryAn entry consisting of port information for a particular Bisync port.
1.3.6.1.4.1.485.3.5.7.1.1.1ColumnbisyncrjeConfigPortIndexread-onlymandatoryThe port number that uniquely identifies this port. Current supported Bisync Rje numbers are 1-4.
1.3.6.1.4.1.485.3.5.7.1.1.2ColumnbisyncrjeConfigTyperead-onlymandatoryThe port type. PRJE (Primary RJE) ports emulate a Host and polls the downstream controllers). SRJE ports (Secondary RJE) ports emulate a line with Terminal Con…
1.3.6.1.4.1.485.3.5.7.1.1.3ColumnbisyncrjeNAUNameread-onlymandatoryThe NAU name of this port. The default value for this field is all blank (filled with ASCII space 0x20 characters).
1.3.6.1.4.1.485.3.5.7.1.1.4ColumnbisyncrjeInitStateread-onlymandatoryThe initial state of the Bisync RJE port. If configured for 'in-service', then the Bisync RJE port will be brougt up automattically when the unit is powered up…
1.3.6.1.4.1.485.3.5.7.1.1.5ColumnbisyncrjeCarrierread-onlymandatoryThis field indicates whether Carrier is constant or switched. The default value for this parameter is 'constant'.
1.3.6.1.4.1.485.3.5.7.1.1.6ColumnbisyncrjeClockingread-onlymandatoryClocking source for this port. Setting 'internal' will cause the port to emulate a physical DCE, and setting external will cause the port to emulate a physical…
1.3.6.1.4.1.485.3.5.7.1.1.7ColumnbisyncrjeSpeedread-onlymandatoryThe ports speed in bits per second. The default value is 9600 bits per second. Speeds higher than 128000 are not supported.
1.3.6.1.4.1.485.3.5.7.1.1.8ColumnbisyncrjeReplyTimerread-onlymandatoryThe time to wait for a response in seconds. The default value for this field is 3 seconds.
1.3.6.1.4.1.485.3.5.7.1.1.9ColumnbisyncrjeRetriesread-onlymandatoryThe maximum number of retries (N2 value) before failing a CU. The default value for this field is 8.
1.3.6.1.4.1.485.3.5.7.1.1.10ColumnbisyncrjeCodeSetread-onlymandatoryThis parameter sets code set to be used for RJE line. The range of this parameter is ASCII and EBCDIC. The default value for this field is EBCDIC.
1.3.6.1.4.1.485.3.5.7.1.1.11ColumnbisyncrjeCTSread-onlymandatoryDefines whether CTS is an input signal used to determine the port status. This parameter is applicable if clocking is set to external. For internal clocking th…
1.3.6.1.4.1.485.3.5.7.1.1.12ColumnbisyncrjeDCDread-onlymandatoryDefines whether DCD is required as input signal or ignored. This parameter is applicable if the clocking is set to external. For internal clocking the paramete…
1.3.6.1.4.1.485.3.5.7.1.1.13ColumnbisyncrjeDSRread-onlymandatoryDefines whether DSR is required as input signal or ignored. This parameter is applicable if the clocking is set to external. For internal clocking the paramete…
1.3.6.1.4.1.485.3.5.7.1.1.14ColumnbisyncrjeDTRread-onlymandatoryDefines whether DTR is required as input signal or ignored. This parameter is applicable if the clocking is set to internal. For external clocking the paramete…
1.3.6.1.4.1.485.3.5.7.1.1.15ColumnbisyncrjeRTSread-onlymandatoryDefines whether RTS is an input signal to determine the port status. This parameter is applicable if the clocking is set to internal. For external clocking the…
1.3.6.1.4.1.485.3.5.7.1.1.16ColumnbisyncrjeReturnClockread-onlymandatoryDefines whether Return Clock (SCTE) is available as input signal or ignored. This parameter is applicable if the clocking is set to internal. For external cloc…
1.3.6.1.4.1.485.3.5.7.2TablebisyncrjeStatsTablenot-accessiblemandatoryA table of Bisync information.
1.3.6.1.4.1.485.3.5.7.2.1RowbisyncrjeStatsEntrynot-accessiblemandatoryAn entry consisting of port information for a particular Bisync port.
1.3.6.1.4.1.485.3.5.7.2.1.1ColumnbisyncrjeStatsPortIndexread-onlymandatoryThe port number that uniquely identifies this Bisync RJE port. Current supported numbers are 1-4.
1.3.6.1.4.1.485.3.5.7.2.1.2ColumnbisyncrjePortTyperead-onlymandatoryThe port type.
1.3.6.1.4.1.485.3.5.7.2.1.3ColumnbisyncrjeInChrsread-onlymandatoryThe number of Characters received.
1.3.6.1.4.1.485.3.5.7.2.1.4ColumnbisyncrjeOutChrsread-onlymandatoryThe number of Characters sent.
1.3.6.1.4.1.485.3.5.7.2.1.5ColumnbisyncrjeInTrnsread-onlymandatoryThe number of Transactions received.
1.3.6.1.4.1.485.3.5.7.2.1.6ColumnbisyncrjeOutTrnsread-onlymandatoryThe number of Transactions sent.
1.3.6.1.4.1.485.3.5.7.2.1.7ColumnbisyncrjeInRetrread-onlymandatoryThe number of Retransmits received.
1.3.6.1.4.1.485.3.5.7.2.1.8ColumnbisyncrjeOutRetrread-onlymandatoryThe number of Retransmits sent.
1.3.6.1.4.1.485.3.5.7.2.1.9ColumnbisyncrjeInEnqread-onlymandatoryThe number of ENQ received.
1.3.6.1.4.1.485.3.5.7.2.1.10ColumnbisyncrjeOutEnqread-onlymandatoryThe number of ENQ sent.
1.3.6.1.4.1.485.3.5.7.2.1.11ColumnbisyncrjeInEtbread-onlymandatoryThe number of ETB received.
1.3.6.1.4.1.485.3.5.7.2.1.12ColumnbisyncrjeOutEtbread-onlymandatoryThe number of ETB sent.
1.3.6.1.4.1.485.3.5.7.2.1.13ColumnbisyncrjeInEtxread-onlymandatoryThe number of ETX received.
1.3.6.1.4.1.485.3.5.7.2.1.14ColumnbisyncrjeOutEtxread-onlymandatoryThe number of ETX sent.
1.3.6.1.4.1.485.3.5.7.2.1.15ColumnbisyncrjeWackread-onlymandatoryThe number of WACK received.
1.3.6.1.4.1.485.3.5.7.2.1.16ColumnbisyncrjeRviread-onlymandatoryThe number of RVI received.
1.3.6.1.4.1.485.3.5.8NodelineDialBackupGroup
1.3.6.1.4.1.485.3.5.8.1TabledialbackupConfigTablenot-accessiblemandatoryA table of Sync product dial backup information.
1.3.6.1.4.1.485.3.5.8.1.1RowdialbackupConfigEntrynot-accessiblemandatoryAn entry consisting of port information for a particular Sync product dial backup port.
1.3.6.1.4.1.485.3.5.8.1.1.1ColumndialbackupConfigPortIndexread-onlymandatoryThis port uniquely identifies the dial backup port. Range is a valid port number.
1.3.6.1.4.1.485.3.5.8.1.1.2ColumndialbackupPortTyperead-onlymandatoryThe Dial backup connect Type.
1.3.6.1.4.1.485.3.5.8.1.1.3ColumndialbackupConnectTyperead-onlymandatoryThe Dial backup connect Type.
1.3.6.1.4.1.485.3.5.8.1.1.4ColumndialbackupFirstDedicatedPortread-onlymandatoryThis defines a frame relay PVC which will cause dial backup if it is declared as failed (deactivated) by the network. Port number is a valid Frame Relay and DL…
1.3.6.1.4.1.485.3.5.8.1.1.5ColumndialbackupassociatedDLCIDedicatedread-onlymandatoryThis defines a frame relay PVC which will cause dial backup if it is declared as failed (deactivated) by the network. DLCI is a valid Frame Relay DLCI.
1.3.6.1.4.1.485.3.5.8.1.1.6ColumndialbackupSecondDedicatedPortread-onlymandatoryThis defines a second frame relay PVC which will cause dial backup if it is declared as failed (deactivated) by the network. Port number is a valid Frame Relay…
1.3.6.1.4.1.485.3.5.8.1.1.7ColumndialbackupassociatedDLCISecondread-onlymandatoryThis defines a second frame relay PVC which will cause dial backup if it is declared as failed (deactivated) by the network. DLCI is a valid Frame Relay DLCI.
1.3.6.1.4.1.485.3.5.8.1.1.8ColumndialbackupDedicatedPortread-onlymandatoryWhen this port fails, dial connection is activated. Range is a valid port number. The default value for this field is 1.
1.3.6.1.4.1.485.3.5.8.1.1.9ColumndialbackupDedicatedLMIPortread-onlymandatoryWhen this port looses LMI connectivity, dial connection is activated. Range is a valid number. The default value for this field is 1.
1.3.6.1.4.1.485.3.5.8.1.1.10ColumndialbackupDialInactivityTimerread-onlymandatoryThis parameter defines inactivity timer for dial connection. Expiration of this timer will cause dial connection to disconnect. The range of this parameter is …
1.3.6.1.4.1.485.3.5.8.1.1.11ColumndialbackupDialSuspendTimerread-onlymandatoryDefines a duration for which the dial connection. will not be attempted after the dial connection is torn down. The range is 0..9999 seconds. Value of 0 disabl…
1.3.6.1.4.1.485.3.5.8.1.1.12ColumndialbackupModemInitStringread-onlymandatoryDefins a modem intialization string. The field is 40 characters long. The default value for this field is all blank (filled with ASCII space 0x20 characters).
1.3.6.1.4.1.485.3.5.8.1.1.13ColumndialbackupModemDialStringread-onlymandatoryDefins a modem dial string to activate dial connection. This field is up to 40 characters long. Dial phone number may be specified here. The default value for …
1.3.6.1.4.1.485.3.5.8.1.1.14ColumndialbackupModemHangStringread-onlymandatoryDefines a modem hang up string to deactivate dial connection. This field is up to 20 characters long. The default value for this field is all blank (filled wit…
1.3.6.1.4.1.485.3.5.8.1.1.15ColumndialbackupDialDelayTimerread-onlymandatoryDefines a duration for which the dial connecton will not be attempted after need to initiate dial connection is detected. The range of this parameter is 0..999…
1.3.6.1.4.1.485.3.5.8.1.1.16ColumndialbackupTreatLLCControlCharactersread-onlymandatoryDefines whether LLC control frames (TEST, XID, RR, RNR, REJ, DISC, UA, DM, FRMR etc. except I frames) are to be considered as user data or not. For a dial back…
1.3.6.1.4.1.485.3.5.8.2TabledialbackupStatsTablenot-accessiblemandatoryA table of Frame Relay information.
1.3.6.1.4.1.485.3.5.8.2.1RowdialbackupStatsEntrynot-accessiblemandatoryAn entry consisting of port information for a particular Frame Relay port.
1.3.6.1.4.1.485.3.5.8.2.1.1ColumndialbackupStatsPortIndexread-onlymandatoryThe port number that uniquely identifies this Dial Backup port.
1.3.6.1.4.1.485.3.5.8.2.1.2ColumndialbackupSuccatmptread-onlymandatoryThe number of successful dial backup attempts.
1.3.6.1.4.1.485.3.5.8.2.1.3Columndialbackupunsuccatmptread-onlymandatoryThe number of unsuccessful dial backup attempts.
1.3.6.1.4.1.485.3.5.8.2.1.4Columndialbackupinactread-onlymandatoryThe Number of times inactivity timer expired.
1.3.6.1.4.1.485.3.5.9NodelineX25Group
1.3.6.1.4.1.485.3.5.9.1Tablex25ConfigTablenot-accessiblemandatoryA table of X25 information.
1.3.6.1.4.1.485.3.5.9.1.1Rowx25ConfigEntrynot-accessiblemandatoryAn entry consisting of port information for a particular X25 port.
1.3.6.1.4.1.485.3.5.9.1.1.1Columnx25ConfigPortIndexread-onlymandatoryThe port number that uniquely identifies this port. Current supported X.25 numbers are 1-4.
1.3.6.1.4.1.485.3.5.9.1.1.2Columnx25ConfigTyperead-onlymandatoryThe port type. XDCE () ports is a logical DCE device waits to receive an incoming call from the X.25 network. XDTE ports is a logical DTE device initiates a to…
1.3.6.1.4.1.485.3.5.9.1.1.3Columnx25NAUNameread-onlymandatoryThe NAU name of this port. The default value for this field is all blank (filled with ASCII space 0x20 characters).
1.3.6.1.4.1.485.3.5.9.1.1.4Columnx25InitStateread-onlymandatoryThe initial state of the X.25 port. If configured for 'in-service', then the X.25 port will be brougt up automattically when the unit is powered up. If configu…
1.3.6.1.4.1.485.3.5.9.1.1.5Columnx25Clockingread-onlymandatoryClocking source for this port. Setting 'internal' will cause the port to emulate a physical DCE, and setting external will cause the port to emulate a physical…
1.3.6.1.4.1.485.3.5.9.1.1.6Columnx25DTEAddressread-onlymandatoryThis parameter specifies the DTE address this port will use to access the X.25 network.
1.3.6.1.4.1.485.3.5.9.1.1.7Columnx25LinkWindowSizeread-onlymandatoryThis parameter sets the maximum number of concurrent unacknowledged I frames at the X.25 data link level. The default value is 7.
1.3.6.1.4.1.485.3.5.9.1.1.8Columnx25T1Timerread-onlymandatoryThe SDLC T1 timer value in 20ths of a second. The default value is 60 (3 seconds).
1.3.6.1.4.1.485.3.5.9.1.1.9Columnx25MaxRetriesread-onlymandatoryThe maximum number of retries (N2 value) before failing a PU. The default value for this field is 8.
1.3.6.1.4.1.485.3.5.9.1.1.10Columnx25PortSpeedread-onlymandatoryThe ports speed in 100 bits per second. The default value is 64000 bits per second. Speeds higher than 19200 are not supported on RS-232 ports units (must be V…
1.3.6.1.4.1.485.3.5.9.1.1.11Columnx25ReceiveWindowSizeread-onlymandatoryThis parameter determines the number of consecutive data packets that the sync unit can receive before requiring an acknowledgment. The default value is 2.
1.3.6.1.4.1.485.3.5.9.1.1.12Columnx25TransmitWindowSizeread-onlymandatoryThis parameter determines the number of consecutive data packets to be transmitted on the X.25 network before requiring an acknowledgment. The value you config…
1.3.6.1.4.1.485.3.5.9.1.1.13Columnx25ReceivePacketSizeread-onlymandatoryThis parameter defines the size of packets received from the X.25 network in bytes. This value must match the configuration of your X.25 network provider. The …
1.3.6.1.4.1.485.3.5.9.1.1.14Columnx25TransmitPacketSizeread-onlymandatoryThis parameter defines the size of packets transmitted across the X.25 network in bytes. This value must match the configuration of the X.25 network. The defau…
1.3.6.1.4.1.485.3.5.9.1.1.15Columnx25LowTwoWayChannelread-onlymandatoryThis parameter specifies the X.25 packet lower-bound channel number for this physical access line. The default value is 1.
1.3.6.1.4.1.485.3.5.9.1.1.16Columnx25HighTwoWayChannelread-onlymandatoryThis parameter specifies the X.25 packet upper-bound channel number for this physical access line. Note: This value must be greater than the Low Two-Way Channe…
1.3.6.1.4.1.485.3.5.9.1.1.17Columnx25UseCallingAddressread-onlymandatoryThis parameter determines whether the DTE Address assigned to the port you are configuring should be included as a calling address in outgoing call packets. Th…
1.3.6.1.4.1.485.3.5.9.1.1.18Columnx25ForwardingUnitread-onlymandatoryThis parameter limits how many message packets can accumulate before the unit forwards them to higher bytes. The default value is 'EOM'.
1.3.6.1.4.1.485.3.5.9.1.1.19Columnx25DevicePacketSizeread-onlymandatoryWhen the sync unit makes a call on behalf of any configured device, the packet size determines parameter negotiation between the calling and the called packet …
1.3.6.1.4.1.485.3.5.9.1.1.20Columnx25DeviceWindowSizeread-onlymandatoryWhen the sync unit makes a call on behalf of any device, the window size determines parameter negotiation between the calling and the called packet handlers. N…
1.3.6.1.4.1.485.3.5.9.1.1.21Columnx25PlaceReverseChargeCallsread-onlymandatoryThis parameter determines whether the Sync unit will place reverse charge requests on outgoing calls. The default value is 'No'.
1.3.6.1.4.1.485.3.5.9.1.1.22Columnx25AcceptReverseChargeCallsread-onlymandatoryThis parameter determines whether the Sync unit will accept reverse charge requests from incoming calls. The default value is 'No'.
1.3.6.1.4.1.485.3.5.9.1.1.23Columnx25NPSread-onlymandatoryThis parameter indicates if the QLLC conversion NODE is connecting to a NPSI front-end and is to take on a secondary role. The default value is 'No'.
1.3.6.1.4.1.485.3.5.9.1.1.24Columnx25CTSread-onlymandatoryDefines whether CTS is an input signal used to determine the port status. This parameter is applicable if clocking is set to external. For internal clocking th…
1.3.6.1.4.1.485.3.5.9.1.1.25Columnx25DCDread-onlymandatoryDefines whether DCD is required as input signal or ignored. This parameter is applicable if the clocking is set to external. For internal clocking the paramete…
1.3.6.1.4.1.485.3.5.9.1.1.26Columnx25DSRread-onlymandatoryDefines whether DSR is required as input signal or ignored. This parameter is applicable if the clocking is set to external. For internal clocking the paramete…
1.3.6.1.4.1.485.3.5.9.1.1.27Columnx25DTRread-onlymandatoryDefines whether DTR is required as input signal or ignored. This parameter is applicable if the clocking is set to internal. For external clocking the paramete…
1.3.6.1.4.1.485.3.5.9.1.1.28Columnx25RTSread-onlymandatoryDefines whether RTS is an input signal to determine the port status. This parameter is applicable if the clocking is set to internal. For external clocking the…
1.3.6.1.4.1.485.3.5.9.1.1.29Columnx25ReturnClockread-onlymandatoryDefines whether Return Clock (SCTE) is available as input signal or ignored. This parameter is applicable if the clocking is set to internal. For external cloc…
1.3.6.1.4.1.485.3.5.9.1.1.30Columnx25IPAddressread-onlymandatoryThis is the IP Address of this interface.
1.3.6.1.4.1.485.3.5.9.1.1.31Columnx25NetworkMaskread-onlymandatoryThis is the network mask to be used on this interface.
1.3.6.1.4.1.485.3.5.9.1.1.32Columnx25DefaultGatewayAddressread-onlymandatoryDefault gateway address to be used when sending responses on this interface.
1.3.6.1.4.1.485.3.5.9.1.1.33Columnx25SecondDefaultGatewayAddressread-onlymandatorySecond Default gateway address to be used when sending responses on this interface.
1.3.6.1.4.1.485.3.5.9.2Tablex25StatsTablenot-accessiblemandatoryA table of X25 information.
1.3.6.1.4.1.485.3.5.9.2.1Rowx25StatsEntrynot-accessiblemandatoryAn entry consisting of port information for a particular X25 port.
1.3.6.1.4.1.485.3.5.9.2.1.1Columnx25StatsPortIndexread-onlymandatoryThe port number that uniquely identifies this X25 port. Current supported numbers on are 1-8.
1.3.6.1.4.1.485.3.5.9.2.1.2Columnx25PortTyperead-onlymandatoryThe port type. XDCE () ports is a logical DCE device waits to receive an incoming call from the X.25 network. XDTE ports is a logical DTE device initiates a to…
1.3.6.1.4.1.485.3.5.9.2.1.3Columnx25InFramesread-onlymandatoryThe number of I-frames received.
1.3.6.1.4.1.485.3.5.9.2.1.4Columnx25OutFramesread-onlymandatoryThe number of I-frames sent.
1.3.6.1.4.1.485.3.5.9.2.1.5Columnx25CInFramesread-onlymandatoryThe number of Control-frames received.
1.3.6.1.4.1.485.3.5.9.2.1.6Columnx25COutFramesread-onlymandatoryThe number of Control-frames sent.
1.3.6.1.4.1.485.3.5.9.2.1.7Columnx25FRMRInFramesread-onlymandatoryThe number of FRMR-frames received.
1.3.6.1.4.1.485.3.5.9.2.1.8Columnx25FRMROutFramesread-onlymandatoryThe number of FRMR-frames sent.
1.3.6.1.4.1.485.3.5.9.2.1.9Columnx25Timeoutsread-onlymandatoryThe number of Timeouts.
1.3.6.1.4.1.485.3.5.9.2.1.10Columnx25UFramesread-onlymandatoryThe number of Undefined Frames.
1.3.6.1.4.1.485.3.5.9.2.1.11Columnx25Samplesread-onlymandatoryThe number of Samples.
1.3.6.1.4.1.485.3.5.9.2.1.12Columnx25Sumread-onlymandatoryThe number of Active Channels Sum.
1.3.6.1.4.1.485.3.5.9.2.1.13Columnx25SumsQread-onlymandatoryThe number of Active Channels SumsQ.
1.3.6.1.4.1.485.3.5.9.2.1.14Columnx25DataInPktsread-onlymandatoryThe number of Data Packets received.
1.3.6.1.4.1.485.3.5.9.2.1.15Columnx25DataOutPktsread-onlymandatoryThe number of Data Packets sent.
1.3.6.1.4.1.485.3.5.9.2.1.16Columnx25DataInChrsread-onlymandatoryThe number of Data Characters received.
1.3.6.1.4.1.485.3.5.9.2.1.17Columnx25DataOutChrsread-onlymandatoryThe number of Data Characters sent.
1.3.6.1.4.1.485.3.5.9.2.1.18Columnx25QInPktsread-onlymandatoryThe number of Q-Packets received.
1.3.6.1.4.1.485.3.5.9.2.1.19Columnx25QOutPktsread-onlymandatoryThe number of Q-Packets sent.
1.3.6.1.4.1.485.3.5.9.2.1.20Columnx25QInChrsread-onlymandatoryThe number of Q-Characters received.
1.3.6.1.4.1.485.3.5.9.2.1.21Columnx25QOutChrsread-onlymandatoryThe number of Q-Characters sent.
1.3.6.1.4.1.485.3.5.9.2.1.22Columnx25SigInPktsread-onlymandatoryThe number of Sig-Packets received.
1.3.6.1.4.1.485.3.5.9.2.1.23Columnx25SigOutPktsread-onlymandatoryThe number of Sig-Packets sent.
1.3.6.1.4.1.485.3.5.9.2.1.24Columnx25InResetsread-onlymandatoryThe number of Resets received.
1.3.6.1.4.1.485.3.5.9.2.1.25Columnx25OutResetsread-onlymandatoryThe number of Resets sent.
1.3.6.1.4.1.485.3.5.9.2.1.26Columnx25InRestartsread-onlymandatoryThe number of Restarts received.
1.3.6.1.4.1.485.3.5.9.2.1.27Columnx25OutRestartsread-onlymandatoryThe number of Restarts sent.
1.3.6.1.4.1.485.3.5.10NodelineAlcGroup
1.3.6.1.4.1.485.3.5.10.1TablealcConfigTablenot-accessiblemandatoryA table of ALC information.
1.3.6.1.4.1.485.3.5.10.1.1RowalcConfigEntrynot-accessiblemandatoryAn entry consisting of port information for a particular ALC port.
1.3.6.1.4.1.485.3.5.10.1.1.1ColumnalcConfigPortIndexread-onlymandatoryThe port number that uniquely identifies this port. Current supported X.25 numbers are 1-4.
1.3.6.1.4.1.485.3.5.10.1.1.2ColumnalcConfigTyperead-onlymandatoryThe port type. The default is Teminal ALC.
1.3.6.1.4.1.485.3.5.10.1.1.3ColumnalcNAUNameread-onlymandatoryThe NAU name of this port. The default value for this field is all blank (filled with ASCII space 0x20 characters).
1.3.6.1.4.1.485.3.5.10.1.1.4ColumnalcInitStateread-onlymandatoryThe initial state of the X.25 port. If configured for 'in-service', then the ALC port will be brougt up automattically when the unit is powered up. If configur…
1.3.6.1.4.1.485.3.5.10.1.1.5ColumnalcClockingread-onlymandatoryClocking source for this port. Setting 'internal' will cause the port to emulate a physical DCE, and setting external will cause the port to emulate a physical…
1.3.6.1.4.1.485.3.5.10.1.1.6ColumnalcPortSpeedread-onlymandatoryThe ports speed in 100 bits per second. The default value is 9600 bits per second.
1.3.6.1.4.1.485.3.5.10.1.1.7ColumnalcLimitSegsCharsBetweenPollsread-onlymandatoryThis parameter specifies whether to limit the number of segments sent between pools. If this parameter is set to 'yes' the parameter 'Number of Segments' and '…
1.3.6.1.4.1.485.3.5.10.1.1.8ColumnalcNumberOfSegmentsread-onlymandatoryThis parameter specifies the maximum number of segments that may be sent between polls. This parameter is applicable only if 'Limit SEGs/Chars between polls' i…
1.3.6.1.4.1.485.3.5.10.1.1.9ColumnalcNumberOfCharactersread-onlymandatoryThis parameter specifies the maximum number of characters that may be sent between polls. This parameter is applicable only if 'Limit SEGs/Chars between polls'…
1.3.6.1.4.1.485.3.5.10.1.1.10ColumnalcNumberOfNullSegread-onlymandatoryThis parameter specifies the maximum number of null characters that may be sent between segments. The defualt value is 0.
1.3.6.1.4.1.485.3.5.10.1.1.11ColumnalcCTSread-onlymandatoryDefines whether CTS is an input signal used to determine the port status. This parameter is applicable if clocking is set to external. For internal clocking th…
1.3.6.1.4.1.485.3.5.10.1.1.12ColumnalcDCDread-onlymandatoryDefines whether DCD is required as input signal or ignored. This parameter is applicable if the clocking is set to external. For internal clocking the paramete…
1.3.6.1.4.1.485.3.5.10.1.1.13ColumnalcDSRread-onlymandatoryDefines whether DSR is required as input signal or ignored. This parameter is applicable if the clocking is set to external. For internal clocking the paramete…
1.3.6.1.4.1.485.3.5.10.1.1.14ColumnalcDTRread-onlymandatoryDefines whether DTR is required as input signal or ignored. This parameter is applicable if the clocking is set to internal. For external clocking the paramete…
1.3.6.1.4.1.485.3.5.10.1.1.15ColumnalcRTSread-onlymandatoryDefines whether RTS is an input signal to determine the port status. This parameter is applicable if the clocking is set to internal. For external clocking the…
1.3.6.1.4.1.485.3.5.10.1.1.16ColumnalcReturnClockread-onlymandatoryDefines whether Return Clock (SCTE) is available as input signal or ignored. This parameter is applicable if the clocking is set to internal. For external cloc…
1.3.6.1.4.1.485.3.5.10.2TablealcStatsTablenot-accessiblemandatoryA table of X25 information.
1.3.6.1.4.1.485.3.5.10.2.1RowalcStatsEntrynot-accessiblemandatoryAn entry consisting of port information for a particular X25 port.
1.3.6.1.4.1.485.3.5.10.2.1.1ColumnalcStatsPortIndexread-onlymandatoryThe port number that uniquely identifies this Alc port. Current supported numbers on are 1-8.
1.3.6.1.4.1.485.3.5.10.2.1.2ColumnalcPortTyperead-onlymandatoryThe port type. The default is Terminal Alc.
1.3.6.1.4.1.485.3.5.10.2.1.3ColumnalcRxOverrunsread-onlymandatoryThe number of Received Overruns.
1.3.6.1.4.1.485.3.5.10.2.1.4ColumnalcBytesRxread-onlymandatoryThe number of Bytes Received.
1.3.6.1.4.1.485.3.5.10.2.1.5ColumnalcBytesTxread-onlymandatoryThe number of Bytes Transmitted.
1.3.6.1.4.1.485.3.5.10.2.1.6ColumnalcBytesRxDiscread-onlymandatoryThe number of Bytes Received.
1.3.6.1.4.1.485.3.5.10.2.1.7ColumnalcBytesTxDiscread-onlymandatoryThe number of Bytes Transmitted.
1.3.6.1.4.1.485.3.5.10.2.1.8ColumnalcPortFaultsread-onlymandatoryThe number of Bytes Transmitted.
1.3.6.1.4.1.485.3.5.10.2.1.9ColumnalcRcvCCCErrorsread-onlymandatoryThe number of Bytes Transmitted.
1.3.6.1.4.1.485.3.5.10.2.1.10ColumnalcPollTxread-onlymandatoryThe number of Bytes Transmitted.
1.3.6.1.4.1.485.3.5.10.2.1.11ColumnalcResponseTimeoutsread-onlymandatoryThe number of Bytes Transmitted.
1.3.6.1.4.1.485.3.5.10.2.1.12ColumnalcSegRxread-onlymandatoryThe number of Segments Received.
1.3.6.1.4.1.485.3.5.10.2.1.13ColumnalcSegTxread-onlymandatoryThe number of Segments Transmitted.
1.3.6.1.4.1.485.3.5.10.2.1.14ColumnalcSegRxDiscread-onlymandatoryThe number of Received Segments Discarded.
1.3.6.1.4.1.485.3.5.10.2.1.15ColumnalcSegTxDiscread-onlymandatoryThe number of Transmitted Segments Discarded.
1.3.6.1.4.1.485.3.6NodenodePUGroup
1.3.6.1.4.1.485.3.6.1NodepuControlGroup
1.3.6.1.4.1.485.3.6.1.1TablepuControlTablenot-accessiblemandatoryA table for controlling lines and obtaining information.
1.3.6.1.4.1.485.3.6.1.1.1RowpuControlEntrynot-accessiblemandatoryAn entry consisting of PU information for a particular port.
1.3.6.1.4.1.485.3.6.1.1.1.1ColumnpuControlLineIndexread-onlymandatoryThe port number that has a given PU.
1.3.6.1.4.1.485.3.6.1.1.1.2ColumnpuControlPUAddressread-onlymandatoryThe PU address in the range of 0x01 to 0xfe.
1.3.6.1.4.1.485.3.6.1.1.1.3ColumnpuStatusread-writemandatoryThe status of the PU. To change status of a port an enable, enable all or disable may be set. Valid Return status are enable(d), disable(d), or failed. Command…
1.3.6.1.4.1.485.3.6.1.1.1.4ColumnpuConnectionStatusread-onlymandatoryThe status of the LLC type 2 Connection for this SDLC PU.
1.3.6.1.4.1.485.3.6.1.1.1.5ColumnpuLastClearCoderead-onlymandatoryA two octet field indicating the Last Clearing Cause and Diagnostic Field of the last failed connection attempt (a.k.a. call attempt) or active connection (a.k…
1.3.6.1.4.1.485.3.6.1.1.1.6ColumnpuControlFailureCoderead-onlymandatoryThis entry contains the failure codes if the associated PU is in the failed state.
1.3.6.1.4.1.485.3.6.1.1.1.7ColumnpuControlNAUNameread-onlymandatoryThe NAU name of this PU. The default value for this field is all blank (filled with ASCII space 0x20 characters).
1.3.6.1.4.1.485.3.6.1.1.1.8ColumnpuConnectionAttemptCountread-onlymandatoryThe number of connection attempts performed. This count is set to zero at startup, and after every loss of an estabished session.
1.3.6.1.4.1.485.3.6.1.1.1.9ColumnpuStatusIgnoredread-writemandatoryThis field is used for consolidating status of the unit. The status of this pu is not put into consideration when consolidating status of the unit if this fiel…
1.3.6.1.4.1.485.3.6.1.1.1.10ColumnpuStatusAcknowledgedread-writemandatoryThis field is used for consolidating status of the unit. When this field is set to yes, the unit will re-consolidate its status without putting the status of t…
1.3.6.1.4.1.485.3.6.1.1.1.11ColumnpuLastDlciClearedread-onlymandatorySpecifies the dlci that the last clear code was associated with. If the last clear code was not associated with a virtual route, i.e. the clear was associated …
1.3.6.1.4.1.485.3.6.1.1.1.12ColumnpuCurrentDlciread-onlymandatorySpecifies the DLCI active for a session at this time. For LAN or X25 network interface, this field is set to 0
1.3.6.1.4.1.485.3.6.1.1.1.13ColumnpuLastMACClearedread-onlymandatorySpecifies the MAC address that the last clear code was associated with.
1.3.6.1.4.1.485.3.6.1.1.1.14ColumnpuCurrentMACread-onlymandatorySpecifies the MAC address that the current session is associated with. For X25 network type, this is set to 0.
1.3.6.1.4.1.485.3.6.1.1.1.15ColumnpuNetworkTyperead-onlymandatorySpecifies netowrk type that the current session is associated with.
1.3.6.1.4.1.485.3.6.1.1.1.16ColumnpuCurrentConnectionTyperead-onlymandatorySpecifies network layer that the current session is associated with.
1.3.6.1.4.1.485.3.6.1.1.1.17ColumnpuLastSVCClearedread-onlymandatorySpecifies the LCN that the last clear code is associated with. If the last clear code was not associated with a X25 SVC, i.e. the clear was associated with the…
1.3.6.1.4.1.485.3.6.1.1.1.18ColumnpuCurrentSVCread-onlymandatorySpecifies the that the current session is associated with. For non X25 network type, this field is set to 0
1.3.6.1.4.1.485.3.6.1.1.1.19ColumnpuLastLocalDTEClearedread-onlymandatorySpecifies the local DTE address that the last clear code is associated with. For non X25 network type, this field is set to 0
1.3.6.1.4.1.485.3.6.1.1.1.20ColumnpuLastRemoteDTEClearedread-onlymandatorySpecifies the remote DTE address that the last clear code is associated with. For non X25 network type, this field is set to 0
1.3.6.1.4.1.485.3.6.1.1.1.21ColumnpuCurrentLocalDTEread-onlymandatorySpecifies the local DTE address that the current session is associated with. For non X25 network type, this field is set to 0
1.3.6.1.4.1.485.3.6.1.1.1.22ColumnpuCurrentRemoteDTEread-onlymandatorySpecifies the remote DTE address that the current session is associated with. For non X25 network type, this field is set to 0
1.3.6.1.4.1.485.3.6.1.1.1.23ColumnpuIsDynamicread-writemandatoryThe type of PU. YES means that the PU is a dynamic pu created by auto LLC. The puStatus for any dynamic PU must be enabled
1.3.6.1.4.1.485.3.6.2NodepuSDLCGroup
1.3.6.1.4.1.485.3.6.2.1TablesdlcPuConfigTablenot-accessiblemandatoryA list of PU entries.
1.3.6.1.4.1.485.3.6.2.1.1RowsdlcPuConfigEntrynot-accessiblemandatoryThis entry contains information about a given PU. The entry is indexed by the port number and the PU number.
1.3.6.1.4.1.485.3.6.2.1.1.1ColumnsdlcPuConfigLineIndexread-onlymandatoryThe port number for which the line (CU)is configured (first level).
1.3.6.1.4.1.485.3.6.2.1.1.2ColumnsdlcPuConfigAddressread-onlymandatoryThe PU address in the range of 0x00 to 0xfe.
1.3.6.1.4.1.485.3.6.2.1.1.3ColumnsdlcPuNAUNameread-onlymandatoryThe NAU name of this PU. The default value for this field is all blank (filled with ASCII space 0x20 characters).
1.3.6.1.4.1.485.3.6.2.1.1.4ColumnsdlcPuInitialStateread-onlymandatoryThe initial state of the PU. If configured for 'in-service', then the SDLC PU will be brougt up automattically when the unit is powered up. If configured for '…
1.3.6.1.4.1.485.3.6.2.1.1.5ColumnsdlcPuXIDread-onlymandatoryThe XID value for this PU. The XID is used to identify the PU during the LLC connection process to the remote Host or Gateway. If the field is configured to 0 …
1.3.6.1.4.1.485.3.6.2.1.1.6ColumnsdlcPuTyperead-onlymandatoryThe SNA PU type. 1 = PU type 1 2 = PU type 2 3 = PU type 2.1 4 = PU type 4 5 = PU type 5 (not supported, reserved) This parameter defaults to a value of 2.
1.3.6.1.4.1.485.3.6.2.1.1.7ColumnsdlcPuGroupPollAddressread-onlymandatoryThe PU's group address in the range of 0x01 to 0xfe. setting this value to 0 will disable the group poll feature for polling this and other PUs in a group. The…
1.3.6.1.4.1.485.3.6.2.1.1.8ColumnsdlcPuConnectionIDread-onlymandatoryThis entry defines the Connection ID to a corresponding entry in the mapping table. The default value for this field is all zeroes.
1.3.6.1.4.1.485.3.6.2.1.1.9ColumnsdlcPuMAXOUTread-onlymandatoryThis entry defines the maximum number of outstanding I frames that the PU will allow. This field is applicable to TSDLC only.
1.3.6.1.4.1.485.3.6.2.1.1.10ColumnsdlcPuConnectTyperead-onlymandatoryThe SNA PU Connection type.
1.3.6.1.4.1.485.3.6.2.2TablesdlcPuStatsTablenot-accessiblemandatoryA list of PU statistics entries.
1.3.6.1.4.1.485.3.6.2.2.1RowsdlcPuStatsEntrynot-accessiblemandatoryThis entry contains information about a given PU. The entry is indexed by the port number and the PU number.
1.3.6.1.4.1.485.3.6.2.2.1.1ColumnsdlcPuStatsLineIndexread-onlymandatoryThe port number for which PU is configured on.
1.3.6.1.4.1.485.3.6.2.2.1.2ColumnsdlcPuStatsAddressread-onlymandatoryThe PU address in the range of 0x00 to 0xfe.
1.3.6.1.4.1.485.3.6.2.2.1.3ColumnsdlcPuInIFramesread-onlymandatoryThe number of I frames received on this PU.
1.3.6.1.4.1.485.3.6.2.2.1.4ColumnsdlcPuOutIFramesread-onlymandatoryThe number of I frames trasnmitted on this PU.
1.3.6.1.4.1.485.3.6.2.2.1.5ColumnsdlcPuInRRFramesread-onlymandatoryThe number of RR frames received on this PU.
1.3.6.1.4.1.485.3.6.2.2.1.6ColumnsdlcPuOutRRFramesread-onlymandatoryThe number of RR frames transmitted on this PU.
1.3.6.1.4.1.485.3.6.2.2.1.7ColumnsdlcPuInRNRFramesread-onlymandatoryThe number of RNR frames received on this PU.
1.3.6.1.4.1.485.3.6.2.2.1.8ColumnsdlcPuOutRNRFramesread-onlymandatoryThe number of RNR frames transmitted on this PU.
1.3.6.1.4.1.485.3.6.2.2.1.9ColumnsdlcPuInXIDFramesread-onlymandatoryThe number of XID frames received on this PU.
1.3.6.1.4.1.485.3.6.2.2.1.10ColumnsdlcPuOutXIDFramesread-onlymandatoryThe number of XID frames transmitted on this PU.
1.3.6.1.4.1.485.3.6.2.2.1.11ColumnsdlcPuInTESTFramesread-onlymandatoryThe number of TEST frames received on this PU.
1.3.6.1.4.1.485.3.6.2.2.1.12ColumnsdlcPuOutTESTFramesread-onlymandatoryThe number of TEST frames transmitted on this PU.
1.3.6.1.4.1.485.3.6.2.2.1.13ColumnsdlcPuInSNRMFramesread-onlymandatoryThe number of SNRM frames received on this PU.
1.3.6.1.4.1.485.3.6.2.2.1.14ColumnsdlcPuOutSNRMFramesread-onlymandatoryThe number of SNRM frames transmitted on this PU.
1.3.6.1.4.1.485.3.6.2.2.1.15ColumnsdlcPuInDISCFramesread-onlymandatoryThe number of DISC frames received on this PU.
1.3.6.1.4.1.485.3.6.2.2.1.16ColumnsdlcPuOutDISCFramesread-onlymandatoryThe number of DISC frames transmitted on this PU.
1.3.6.1.4.1.485.3.6.2.2.1.17ColumnsdlcPuInDMFramesread-onlymandatoryThe number of DM frames received on this PU.
1.3.6.1.4.1.485.3.6.2.2.1.18ColumnsdlcPuOutDMFramesread-onlymandatoryThe number of DM frames transmitted on this PU.
1.3.6.1.4.1.485.3.6.2.2.1.19ColumnsdlcPuInUAFramesread-onlymandatoryThe number of UA frames received on this PU.
1.3.6.1.4.1.485.3.6.2.2.1.20ColumnsdlcPuOutUAFramesread-onlymandatoryThe number of UA frames transmitted on this PU.
1.3.6.1.4.1.485.3.6.2.2.1.21ColumnsdlcPuInFRMRFramesread-onlymandatoryThe number of FRMR frames received on this PU.
1.3.6.1.4.1.485.3.6.2.2.1.22ColumnsdlcPuOutFRMRFramesread-onlymandatoryThe number of FRMR frames transmitted on this PU.
1.3.6.1.4.1.485.3.6.2.2.1.23ColumnsdlcPuInRDFramesread-onlymandatoryThe number of RD frames received on this PU.
1.3.6.1.4.1.485.3.6.2.2.1.24ColumnsdlcPuOutRDFramesread-onlymandatoryThe number of RD frames transmitted on this PU.
1.3.6.1.4.1.485.3.6.2.2.1.25ColumnsdlcPuInUIFramesread-onlymandatoryThe number of UI frames received on this PU.
1.3.6.1.4.1.485.3.6.2.2.1.26ColumnsdlcPuOutUIFramesread-onlymandatoryThe number of UI frames transmitted on this PU.
1.3.6.1.4.1.485.3.6.2.2.1.27ColumnsdlcPuReTxIFramesread-onlymandatoryThe number of re-transmitted I frames on this PU.
1.3.6.1.4.1.485.3.6.2.2.1.28ColumnsdlcPuPollResponseTimeoutsread-onlymandatoryThe number of PU Poll Response timeouts for this PU.
1.3.6.1.4.1.485.3.6.3NodepuBisyncGroup
1.3.6.1.4.1.485.3.6.3.1TablebisyncPuConfigTablenot-accessiblemandatoryA list of Bisync CU entries.
1.3.6.1.4.1.485.3.6.3.1.1RowbisyncPuConfigEntrynot-accessiblemandatoryThis entry contains information about a given PU. The entry is indexed by the port number and the PU number.
1.3.6.1.4.1.485.3.6.3.1.1.1ColumnbisyncPuConfigLineIndexread-onlymandatoryThe port number for which PU is configured on.
1.3.6.1.4.1.485.3.6.3.1.1.2ColumnbisyncPuConfigAddressread-onlymandatoryThe PU address in the range of 0x00 to 0xfe.
1.3.6.1.4.1.485.3.6.3.1.1.3ColumnbisyncPuNAUNameread-onlymandatoryThe NAU name of this PU. The default value for this field is all blank (filled with ASCII space 0x20 characters).
1.3.6.1.4.1.485.3.6.3.1.1.4ColumnbisyncPuInitialStateread-onlymandatoryThe initial state of the PU. If configured for 'in-service', then the Bisync PU will be brougt up automattically when the unit is powered up. If configured for…
1.3.6.1.4.1.485.3.6.3.1.1.5ColumnbisyncPuXIDread-onlymandatoryThe XID value for this PU. The XID is used to identify the PU during the LLC connection process to the remote Host or Gateway. The unit will insert the data co…
1.3.6.1.4.1.485.3.6.3.1.1.6ColumnbisyncPuTargetHostTyperead-onlymandatoryThe Target Host type. This field specifies the target host type for TBSC and is applicable to BSC-to-SNA conversion only. This parameter defaults to a value of…
1.3.6.1.4.1.485.3.6.3.1.1.7ColumnbisyncPuMaxDataread-onlymandatoryThis entry defines the SNA frame size which is the sum of SNA data and SNA header. This value must match the MAXData configured for SNA host and is applicable …
1.3.6.1.4.1.485.3.6.3.1.1.8ColumnbisyncPuConnectionIDread-onlymandatoryThis entry defines the Connection ID to a corresponding entry in the mapping table. The default value for this field is all zeroes.
1.3.6.1.4.1.485.3.6.3.1.1.9ColumnbisyncPuConnectTyperead-onlymandatoryThe Bisync PU Connection type.
1.3.6.1.4.1.485.3.6.3.2TablebisyncPuStatsTablenot-accessiblemandatoryA list of PU statistics entries.
1.3.6.1.4.1.485.3.6.3.2.1RowbisyncPuStatsEntrynot-accessiblemandatoryThis entry contains information about a given PU. The entry is indexed by the port number and the PU number.
1.3.6.1.4.1.485.3.6.3.2.1.1ColumnbisyncPuStatsLineIndexread-onlymandatoryThe port number for which PU is configured on.
1.3.6.1.4.1.485.3.6.3.2.1.2ColumnbisyncPuStatsAddressread-onlymandatoryThe PU address in the range of 0x00 to 0xfe.
1.3.6.1.4.1.485.3.6.3.2.1.3ColumnbisyncPuInTransactionsread-onlymandatoryThe number of PU Poll Response timeouts for this PU.
1.3.6.1.4.1.485.3.6.3.2.1.4ColumnbisyncPuOutTransactionsread-onlymandatoryThe number of PU Poll Response timeouts for this PU.
1.3.6.1.4.1.485.3.6.3.2.1.5ColumnbisyncPuSlowPollsread-onlymandatoryThe number of PU slow polls for this PU.
1.3.6.1.4.1.485.3.6.3.2.1.6ColumnbisyncPuPollsread-onlymandatoryThe number of PU Polls for this PU.
1.3.6.1.4.1.485.3.6.4NodepuMappingGroup
1.3.6.1.4.1.485.3.6.4.1TablemappingPuConfigTablenot-accessiblemandatoryThis Table is obsolete. A list of PU mapping entries.
1.3.6.1.4.1.485.3.6.4.1.1RowmappingPuConfigEntrynot-accessiblemandatoryThis field is obsolete. This entry contains information about a given mapping PU. Each entry includes MAC/SAP information for a source PU and a similar informa…
1.3.6.1.4.1.485.3.6.4.1.1.1ColumnmappingPuConfigLineIndexread-onlymandatoryThis field is obsolete. The port number for which PU is associated with. Port number 99 is a special value which is used to indicate NetView PU.
1.3.6.1.4.1.485.3.6.4.1.1.2ColumnmappingPuConfigAddressread-onlymandatoryThis field is obsolete. The PU address in the range of 0x01 to 0xfe.
1.3.6.1.4.1.485.3.6.4.1.1.3ColumnmappingPuSourceSAPread-onlymandatoryThis field is obsolete. The LLC source SAP value for this PU. Typically the source SAP will vary for each PU. This is due to the fact that most Sync products a…
1.3.6.1.4.1.485.3.6.4.1.1.4ColumnmappingPuDestinationSAPread-onlymandatoryThis field is obsolete. The LLC Destination SAP value for this PU. For SNA typically the destination is almost always SAP 4. However both Host Front Ends (e.g.…
1.3.6.1.4.1.485.3.6.4.1.1.5ColumnmappingPuDestinationMACread-onlymandatoryThis field is obsolete. The LAN Destination MAC address used in the LLC Type 2 connection for this PU. The Token-Ring format for this field is a 6 octet (48 bi…
1.3.6.1.4.1.485.3.6.4.1.1.6ColumnmappingPuPartnerConfigLineIndexread-onlymandatoryThis field is obsolete. The port number for the partner PU associated with source PU. Port number 99 is a special value which is used to indicate NetView PU.
1.3.6.1.4.1.485.3.6.4.1.1.7ColumnmappingPuPartnerConfigAddressread-onlymandatoryThis field is obsolete. The PU address of the partner PU in the range of 0x01 to 0xfe.
1.3.6.1.4.1.485.3.6.4.1.1.8ColumnmappingPuPartnerSourceSAPread-onlymandatoryThis field is obsolete. The LLC source SAP value for a partner PU. Typically the source SAP will vary for each PU. This is due to the fact that most Sync produ…
1.3.6.1.4.1.485.3.6.4.1.1.9ColumnmappingPuPartnerDestSAPread-onlymandatoryThis field is obsolete. The LLC Destination SAP value for the partner PU. For SNA typically the destination is almost always SAP 4. However both Host Front End…
1.3.6.1.4.1.485.3.6.4.1.1.10ColumnmappingPuPartnerDestMACread-onlymandatoryThis field is obsolete. The LAN Destination MAC address used in the LLC Type 2 connection for the partner PU. The Token-Ring format for this field is a 6 octet…
1.3.6.1.4.1.485.3.6.4.1.1.11ColumnmappingPuNAUread-onlymandatoryThis field is obsolete. The NAU Name. The NAU name is same for both the source PU and the partner PU. It represents one physical PU in a network.
1.3.6.1.4.1.485.3.6.4.1.1.12ColumnmappingPuConnectIDread-onlymandatoryThis field is obsolete. The connection ID. This must match a connection ID of an access line PU or another mapping PU Connection ID. The connnection ID is 0 if…
1.3.6.1.4.1.485.3.6.4.1.1.13ColumnmappingPuXIDread-onlymandatoryThis field is obsolete. The XID value for this PU. The XID is used to identify the PU during the LLC connection process to the remote Host or Gateway. For inco…
1.3.6.1.4.1.485.3.6.4.1.1.14ColumnmappingPuDirectDLCIread-onlymandatoryThis field is obsolete. The Frame Relay DLCI used in the LLC Type 2 connection for this PU. The Frame Relay format for this field is a 2 octet (16 bit) field r…
1.3.6.1.4.1.485.3.6.4.1.1.15ColumnmappingPuLastClearCoderead-onlymandatoryThis field is obsolete. A two octet field indicating the Last Clearing Cause and Diagnostic Field of the last failed connection attempt (a.k.a. call attempt) o…
1.3.6.1.4.1.485.3.6.4.1.1.16ColumnmappingPuConnAttemptCntread-onlymandatoryThis field is obsolete. The number of connection attempts performed for this PU. This count is set to zero at startup, and after every loss of an estabished se…
1.3.6.1.4.1.485.3.6.4.1.1.17ColumnmappingPuPartnerLastClearCoderead-onlymandatoryThis field is obsolete. A two octet field indicating the Last Clearing Cause and Diagnostic Field of the last failed connection attempt (a.k.a. call attempt) o…
1.3.6.1.4.1.485.3.6.4.1.1.18ColumnmappingPuPartnerConnAttemptCntread-onlymandatoryThis field is obsolete. The number of connection attempts performed for the partner PU. This count is set to zero at startup, and after every loss of an estabi…
1.3.6.1.4.1.485.3.6.5NodepuAsyncGroup
1.3.6.1.4.1.485.3.6.5.1TableasyncPuConfigTablenot-accessiblemandatoryA list of PU entries.
1.3.6.1.4.1.485.3.6.5.1.1RowasyncPuConfigEntrynot-accessiblemandatoryThis entry contains information about a given PU. The entry is indexed by the port number and the PU number.
1.3.6.1.4.1.485.3.6.5.1.1.1ColumnasyncPuConfigLineIndexread-onlymandatoryThe port number for which the line (CU)is configured (first level).
1.3.6.1.4.1.485.3.6.5.1.1.2ColumnasyncPuConfigAddressread-onlymandatoryThe PU address in the range of 0x00 to 0xfe.
1.3.6.1.4.1.485.3.6.5.1.1.3ColumnasyncPuNAUNameread-onlymandatoryThe NAU name of this PU. The default value for this field is all blank (filled with ASCII space 0x20 characters).
1.3.6.1.4.1.485.3.6.5.1.1.4ColumnasyncPuInitialStateread-onlymandatoryThe initial state of the PU. If configured for 'in-service', then the async PU will be brougt up automattically when the unit is powered up. If configured for …
1.3.6.1.4.1.485.3.6.5.1.1.5ColumnasyncPuXIDread-onlymandatoryThe XID value for this PU. The XID is used to identify the PU during the LLC connection process to the remote Host or Gateway. If the field is configured to 0 …
1.3.6.1.4.1.485.3.6.5.1.1.6ColumnasyncPuConnectionIDread-onlymandatoryThis entry defines the Connection ID to a corresponding entry in the mapping table. The default value for this field is all zeroes.
1.3.6.1.4.1.485.3.6.5.1.1.7ColumnasyncPuConnectTyperead-onlymandatoryThe Async PU Connection type.
1.3.6.1.4.1.485.3.6.5.1.1.8ColumnasyncPuDeviceRangeLowread-onlymandatoryThe device range number low specifies the low number of a range one or more device addresses for which the data to be routed via the connection information (i.…
1.3.6.1.4.1.485.3.6.5.1.1.9ColumnasyncPuDeviceRangeHighread-onlymandatoryThe device range number high specifies the high number of a range of one or more device addresses for which the data to be routed via the connection informatio…
1.3.6.1.4.1.485.3.6.5.2TableasyncPuStatsTablenot-accessiblemandatoryA list of PU statistics entries.
1.3.6.1.4.1.485.3.6.5.2.1RowasyncPuStatsEntrynot-accessiblemandatoryThis entry contains information about a given PU. The entry is indexed by the port number and the PU number.
1.3.6.1.4.1.485.3.6.5.2.1.1ColumnasyncPuStatsLineIndexread-onlymandatoryThe port number for which PU is configured on.
1.3.6.1.4.1.485.3.6.5.2.1.2ColumnasyncPuStatsAddressread-onlymandatoryThe PU address in the range of 0x00 to 0xfe.
1.3.6.1.4.1.485.3.6.5.2.1.3ColumnasyncPuInCharsread-onlymandatoryThe number of characters received for this PU.
1.3.6.1.4.1.485.3.6.5.2.1.4ColumnasyncPuOutCharsread-onlymandatoryThe number of characters transmitted to this PU.
1.3.6.1.4.1.485.3.6.5.2.1.5ColumnasyncPuInMessagesread-onlymandatoryThe number of messages received from this PU.
1.3.6.1.4.1.485.3.6.5.2.1.6ColumnasyncPuOutMessagesread-onlymandatoryThe number of messages transmitted to this PU.
1.3.6.1.4.1.485.3.6.6NodepuLanGroup
1.3.6.1.4.1.485.3.6.6.1TablelanPuConfigTablenot-accessiblemandatoryA list of PU entries.
1.3.6.1.4.1.485.3.6.6.1.1RowlanPuConfigEntrynot-accessiblemandatoryThis entry contains information about a given PU. The entry is indexed by the port number and the PU number.
1.3.6.1.4.1.485.3.6.6.1.1.1ColumnlanPuConfigLineIndexread-onlymandatoryThe port number for which the line (CU)is configured (first level).
1.3.6.1.4.1.485.3.6.6.1.1.2ColumnlanPuConfigAddressread-onlymandatoryThe PU address in the range of 0x00 to 0xff.
1.3.6.1.4.1.485.3.6.6.1.1.3ColumnlanPuNAUNameread-onlymandatoryThe NAU name of this PU. The default value for this field is all blank (filled with ASCII space 0x20 characters).
1.3.6.1.4.1.485.3.6.6.1.1.4ColumnlanPuXIDread-onlymandatoryThe XID value for this PU. The XID is used to identify the PU during the LLC connection process to the remote Host or Gateway. If the field is configured to 0 …
1.3.6.1.4.1.485.3.6.6.1.1.5ColumnlanPuConnectionIDread-onlymandatoryThis entry defines the Connection ID to a corresponding entry in the mapping table. The default value for this field is all zeroes.
1.3.6.1.4.1.485.3.6.6.1.1.6ColumnlanPuSourceSAPread-onlymandatoryThe LLC source SAP value for this PU. Typically the source SAP will vary for each PU. This is due to the fact that most Sync products are configured to always …
1.3.6.1.4.1.485.3.6.6.1.1.7ColumnlanPuDestinationSAPread-onlymandatoryThe LLC Destination SAP value for this PU. For SNA typically the destination is almost always SAP 4. However both Host Front Ends (e.g. 3745) or Gateways (e.g.…
1.3.6.1.4.1.485.3.6.6.1.1.8ColumnlanPuMACread-onlymandatoryThe LAN Destination MAC address used in the LLC Type 2 connection for this PU. The Token-Ring format for this field is a 6 octet (48 bit) field represented in …
1.3.6.1.4.1.485.3.6.6.1.1.9ColumnlanPuAlternateMACAddressread-onlymandatorySpecifies the second destination MAC address for a disaster recovery site.
1.3.6.1.4.1.485.3.6.7NodepuRemoteGroup
1.3.6.1.4.1.485.3.6.7.1TableremotePuConfigTablenot-accessiblemandatoryA list of PU mapping entries.
1.3.6.1.4.1.485.3.6.7.1.1RowremotePuConfigEntrynot-accessiblemandatoryThis entry contains information about a given mapping PU. Each entry includes MAC/SAP information for a source PU and a similar information for the partner (ma…
1.3.6.1.4.1.485.3.6.7.1.1.1ColumnaccessPuConfigLineIndexread-onlymandatoryThe port number for which PU is associated with. Port number 99 is a special value which is used to indicate NetView PU.
1.3.6.1.4.1.485.3.6.7.1.1.2ColumnaccessPuConfigAddressread-onlymandatoryThe PU address in the range of 0x01 to 0xfe. If the accessPuConfigLineIndex indicates a NetView PU then 01 is used to indicate the primary NetView PU and 02 is…
1.3.6.1.4.1.485.3.6.7.1.1.3ColumnremotePuConfigLineIndexread-onlymandatoryThe port number for which an access PU, LCU or XCU is associated with.
1.3.6.1.4.1.485.3.6.7.1.1.4ColumnremotePuConfigAddressread-onlymandatoryThe access PU, LCU or XCU address in the range of 0x01 to 0xfe.
1.3.6.1.4.1.485.3.6.7.1.1.5ColumnremotePuSourceSAPread-onlymandatoryThe LLC source SAP value for this PU. Typically the source SAP will vary for each PU. This is due to the fact that most Sync products are configured to always …
1.3.6.1.4.1.485.3.6.7.1.1.6ColumnremotePuDestinationSAPread-onlymandatoryThe LLC Destination SAP value for this PU. For SNA typically the destination is almost always SAP 4. However both Host Front Ends (e.g. 3745) or Gateways (e.g.…
1.3.6.1.4.1.485.3.6.7.1.1.7ColumnremotePuMACread-onlymandatoryThe LAN Destination MAC address used in the LLC Type 2 connection for this PU. The Token-Ring format for this field is a 6 octet (48 bit) field represented in …
1.3.6.1.4.1.485.3.6.7.1.1.8ColumnremotePuPrimaryDLCIread-onlymandatoryThe Frame Relay DLCI used in the LLC Type 2 connection for this PU. The Frame Relay format for this field is a 2 octet (16 bit) field represented in BCD format…
1.3.6.1.4.1.485.3.6.7.1.1.9ColumnremotePuParallelDLCIread-onlymandatorySpecifies a parallel DLCI indicating a virtual route in parallel to the primary DLCI path. The parallel virtual route allows for session resiliency.
1.3.6.1.4.1.485.3.6.7.1.1.10ColumnremotePuAlternateDLCIread-onlymandatorySpecifies an alternate DLCI indicating a virtual route to a disaster recovery site.
1.3.6.1.4.1.485.3.6.7.1.1.11ColumnremotePuAlternateMACAddressread-onlymandatorySpecifies an alternate MAC address indicating a virtual route to a disaster recovery site.
1.3.6.1.4.1.485.3.6.7.1.1.12ColumnremotePuTransmitPriorityread-onlymandatorySpecifies the transmission priority being URGENT, HIGH, MEDIUM or LOW for this PU.
1.3.6.1.4.1.485.3.6.7.1.1.13ColumnremotePuBroadcastAllDLCIread-onlymandatoryIf this field is set to YES, after all specified paths are determined as unavailable, the session request is broadcast to all DLCIs. IF the primary DLCI is set…
1.3.6.1.4.1.485.3.6.7.1.1.14ColumnremotePuLocalDTEread-onlymandatorySpecifies the local DTE address to match against any in-dial session for an access PU or LAN PU. For non X25 network type, this field is set to 0
1.3.6.1.4.1.485.3.6.7.1.1.15ColumnremotePuRemoteDTEread-onlymandatorySpecifies the remote DTE address that the X25 SVC connection uses for this access PU or LAN PU.
1.3.6.1.4.1.485.3.6.8NodepuX25Group
1.3.6.1.4.1.485.3.6.8.1Tablex25PuConfigTablenot-accessiblemandatoryA list of PU entries.
1.3.6.1.4.1.485.3.6.8.1.1Rowx25PuConfigEntrynot-accessiblemandatoryThis entry contains information about a given PU. The entry is indexed by the port number and the PU number.
1.3.6.1.4.1.485.3.6.8.1.1.1Columnx25PuConfigLineIndexread-onlymandatoryThe port number for which PU is configured on.
1.3.6.1.4.1.485.3.6.8.1.1.2Columnx25PuConfigAddressread-onlymandatoryThe PU address in the range of 0x00 to 0xfe.
1.3.6.1.4.1.485.3.6.8.1.1.3Columnx25PuNAUNameread-onlymandatoryThe NAU name of this PU. The default value for this field is all blank (filled with ASCII space 0x20 characters).
1.3.6.1.4.1.485.3.6.8.1.1.4Columnx25PuConnectionIDread-onlymandatoryThis entry defines the Connection ID to a corresponding entry in the mapping table. The default value for this field is all zeroes.
1.3.6.1.4.1.485.3.6.8.1.1.5Columnx25PuXIDread-onlymandatoryThe XID value for this PU. The XID set the CU identification used to establish and negotiate PU-application sessions. If the PU cannot respond to an XID reques…
1.3.6.1.4.1.485.3.6.8.1.1.6Columnx25PuSolicitXIDread-onlymandatoryThis parameter enables or disables soliciting an XID exchange between the Host and DSPU. This determines whether the Sync unit will solicit an XID to the X.25-…
1.3.6.1.4.1.485.3.6.8.1.1.7Columnx25PuSourceAddressread-onlymandatoryThe paramter specifies the Source Address. This is used to match DTE address.
1.3.6.1.4.1.485.3.6.8.1.1.8Columnx25PuRemoteDTEAddressread-onlymandatoryThe paramter specifies a DTE address on the connection's remote end enabling the Host to initiate a session. If you would rather have the X.25 PU initiate the …
1.3.6.1.4.1.485.3.6.9NodepuAlcGroup
1.3.6.1.4.1.485.3.6.9.1TablealcPuConfigTablenot-accessiblemandatoryA list of PU entries.
1.3.6.1.4.1.485.3.6.9.1.1RowalcPuConfigEntrynot-accessiblemandatoryThis entry contains information about a given PU. The entry is indexed by the port number and the PU number.
1.3.6.1.4.1.485.3.6.9.1.1.1ColumnalcPuConfigLineIndexread-onlymandatoryThe port number for which PU is configured on.
1.3.6.1.4.1.485.3.6.9.1.1.2ColumnalcPuConfigAddressread-onlymandatoryThe PU address in the range of 0x01 to 0x3C (both inclusive) with addresses 0x0d, 0x1D and 0x20 being invalid addresses. The default value is 0x01
1.3.6.1.4.1.485.3.6.9.1.1.3ColumnalcPuNAUNameread-onlymandatoryThe NAU name of this PU. The default value for this field is all blank (filled with ASCII space 0x20 characters).
1.3.6.1.4.1.485.3.6.9.1.1.4ColumnalcPuCSSread-onlymandatoryThe initial state of the CU. The Interchange (CU) should be enabled or not when the configuration is activated. The range is 'in-service' or 'out-of-service'. …
1.3.6.1.4.1.485.3.6.9.1.1.5ColumnalcPuConnectionIDread-onlymandatoryThis entry defines the Connection ID to a corresponding entry in the mapping table. The default value for this field is all zeroes.
1.3.6.1.4.1.485.3.6.9.1.1.6ColumnalcPuXIDread-onlymandatoryThe XID value for this PU. The XID defines an identifier call ID BLOCK and ID NUM, which is used in session establishment using LLC2. The default value for thi…
1.3.6.1.4.1.485.3.6.9.1.1.7ColumnalcPuConnectTyperead-onlymandatoryThe Alc PU Connection type.
1.3.6.1.4.1.485.3.6.9.1.1.8ColumnalcPuLineNumberread-onlymandatoryThe parmater defines a host reference to as line number. The range of this parameter is 0x01 to 0xFF(both inclusive). This parameter must match the Host config…
1.3.6.1.4.1.485.3.6.9.1.1.9ColumnalcPuMaximumFastPollread-onlymandatoryThis parameter defines the maximum time the unit will wait before it polls a device. Typicall the data transfer has priority over polling algorithm. This param…
1.3.6.1.4.1.485.3.6.9.1.1.10ColumnalcPuMinimumFastPollread-onlymandatoryThis parameter defines the minimum time the unit will wait before it polls a device. This parameter ensures that the devices are not polled at a very high rate…
1.3.6.1.4.1.485.3.6.9.1.1.11ColumnalcPuMaximumSlowPollIntervalread-onlymandatoryThis parameter defines the maximum time an inactive device is left out of poll list before it is put back in the poll list. Range of this parameter is from 1 t…
1.3.6.1.4.1.485.3.6.9.1.1.12ColumnalcPuMinimumSlowPollIntervalread-onlymandatoryThis parameter defines the minimum time an inactive device is left out of poll list before it is put back in the poll list. Range of this parameter is from 1 t…
1.3.6.1.4.1.485.3.6.9.1.1.13ColumnalcPuResponseTimeoutread-onlymandatoryThis parameter defines the duration that a unit will wait for a response from a device. Range of this parameter is from 1 through 99 in 10ths of a second. The …
1.3.6.1.4.1.485.3.6.9.1.1.14ColumnalcPuUserDataread-onlymandatoryThe paramter specifies the user data upto sixteen hexadecimal bytes for AX.25 protocol.
1.3.6.1.4.1.485.3.6.9.1.1.15ColumnalcSourceDTEAddressread-onlymandatoryThis parameter specifies the DTE address this port will use to access the Alc network.
1.3.6.1.4.1.485.3.6.9.1.1.16ColumnalcDestinationDTEAddressread-onlymandatoryThis parameter specifies the DTE address this port will use to access the Alc network.
1.3.6.1.4.1.485.3.6.9.2TablealcPuStatsTablenot-accessiblemandatoryA list of PU statistics entries.
1.3.6.1.4.1.485.3.6.9.2.1RowalcPuStatsEntrynot-accessiblemandatoryThis entry contains information about a given PU. The entry is indexed by the port number and the PU number.
1.3.6.1.4.1.485.3.6.9.2.1.1ColumnalcPuStatsLineIndexread-onlymandatoryThe port number for which PU is configured on.
1.3.6.1.4.1.485.3.6.9.2.1.2ColumnalcPuStatsAddressread-onlymandatoryThe PU address in the range of 0x00 to 0xfe.
1.3.6.1.4.1.485.3.6.9.2.1.3ColumnalcPuPollsread-onlymandatoryThe number of Polls.
1.3.6.1.4.1.485.3.6.9.2.1.4ColumnalcPuDeviceFaultsread-onlymandatoryThe number of Device Faults.
1.3.6.1.4.1.485.3.6.9.2.1.5ColumnalcPuBytesRcvread-onlymandatoryThe number of Bytes Received to this PU.
1.3.6.1.4.1.485.3.6.9.2.1.6ColumnalcPuBytesXmitread-onlymandatoryThe number of Bytes Transmitted for this PU.
1.3.6.1.4.1.485.3.6.9.2.1.7ColumnalcPuSegRcvread-onlymandatoryThe number of Segments Received to this PU.
1.3.6.1.4.1.485.3.6.9.2.1.8ColumnalcPuSegXmitread-onlymandatoryThe number of Segments Transmitted for this PU.
1.3.6.1.4.1.485.3.6.10NodepuBisyncRjeGroup
1.3.6.1.4.1.485.3.6.10.1TablebisyncrjePuConfigTablenot-accessiblemandatoryA list of Bisync CU entries.
1.3.6.1.4.1.485.3.6.10.1.1RowbisyncrjePuConfigEntrynot-accessiblemandatoryThis entry contains information about a given PU. The entry is indexed by the port number and the PU number.
1.3.6.1.4.1.485.3.6.10.1.1.1ColumnbisyncrjePuConfigLineIndexread-onlymandatoryThe port number for which PU is configured on.
1.3.6.1.4.1.485.3.6.10.1.1.2ColumnbisyncrjePuConfigAddressread-onlymandatoryThe PU address in the range of 0x00 to 0xfe.
1.3.6.1.4.1.485.3.6.10.1.1.3ColumnbisyncrjePuNAUNameread-onlymandatoryThe NAU name of this PU. The default value for this field is all blank (filled with ASCII space 0x20 characters).
1.3.6.1.4.1.485.3.6.10.1.1.4ColumnbisyncrjePuInitialStateread-onlymandatoryThe initial state of the PU. If configured for 'in-service', then the Bisync RJE PU will be brougt up automattically when the unit is powered up. If configured…
1.3.6.1.4.1.485.3.6.10.1.1.5ColumnbisyncrjePuConnectionIDread-onlymandatoryThis entry defines the Connection ID to a corresponding entry in the mapping table. The default value for this field is all zeroes.
1.3.6.1.4.1.485.3.6.10.1.1.6ColumnbisyncrjePuXIDread-onlymandatoryThe XID value for this PU. The default value for this field is all zeroes.
1.3.6.1.4.1.485.3.6.10.1.1.7ColumnbisyncrjePuConnectTyperead-onlymandatoryThe Bisync RJE PU Connection type.
1.3.6.1.4.1.485.3.7NodenodeDeviceGroup
1.3.6.1.4.1.485.3.7.1NodedeviceControlGroup
1.3.6.1.4.1.485.3.7.1.1TabledeviceControlTablenot-accessiblemandatoryA table for controlling devices and obtaining information.
1.3.6.1.4.1.485.3.7.1.1.1RowdeviceControlEntrynot-accessiblemandatoryAn entry consisting of device information for a particular device.
1.3.6.1.4.1.485.3.7.1.1.1.1ColumndeviceControlIndexread-onlymandatoryThe number that uniquely identifies this device.
1.3.6.1.4.1.485.3.7.1.1.1.2ColumndeviceControlCUIndexread-onlymandatoryThe CU index for this device.
1.3.6.1.4.1.485.3.7.1.1.1.3ColumndeviceControlAddressread-onlymandatoryThe device address.
1.3.6.1.4.1.485.3.7.1.1.1.4ColumndeviceStatusread-writemandatoryThe status of the device. To change (write) status of a device, enable, disable, restart or enable all may be set. Valid Return (read) status are enable(d), di…
1.3.6.1.4.1.485.3.7.1.1.1.5ColumndeviceControlFailureCoderead-onlymandatoryThis entry contains the failure codes if the associated device is in the failed state.
1.3.6.1.4.1.485.3.7.2NodedeviceBSCGroup
1.3.6.1.4.1.485.3.7.2.1TabledeviceConfigTablenot-accessiblemandatoryA list of device entries.
1.3.6.1.4.1.485.3.7.2.1.1RowdeviceConfigEntrynot-accessiblemandatoryThis entry contains information about a given device. The entry is indexed by the port number, CU index, and device.
1.3.6.1.4.1.485.3.7.2.1.1.1ColumndeviceConfigLineIndexread-onlymandatoryThe port number for which the line (CU)is configured (line level).
1.3.6.1.4.1.485.3.7.2.1.1.2ColumndeviceConfigCUIndexread-onlymandatoryThe CU index which this device is configured on (CU level).
1.3.6.1.4.1.485.3.7.2.1.1.3ColumndeviceConfigAddressread-onlymandatoryThe device address in the legal range of BSC poll addresses (device level).
1.3.6.1.4.1.485.3.7.2.1.1.4ColumndeviceConfigTyperead-onlymandatoryThe device type. The default value is crt.
1.3.6.1.4.1.485.3.7.2.2TabledeviceStatsTablenot-accessiblemandatoryA table of device statistics information.
1.3.6.1.4.1.485.3.7.2.2.1RowdeviceStatsEntrynot-accessiblemandatoryThis entry contains information about a given device. The entry is indexed by the port number, CU index, and device.
1.3.6.1.4.1.485.3.7.2.2.1.1ColumnbscDeviceLineIndexread-onlymandatoryThe port number for which the line (CU)is configured (line level).
1.3.6.1.4.1.485.3.7.2.2.1.2ColumnbscDeviceCUIndexread-onlymandatoryThe CU index which this device is configured on (CU level).
1.3.6.1.4.1.485.3.7.2.2.1.3ColumnbscDeviceAddressread-onlymandatoryThe device address in the legal range of BSC poll addresses (device level).
1.3.6.1.4.1.485.3.7.2.2.1.4ColumnbscDeviceInTransactionsread-onlymandatoryThe number of device receiving transactions.
1.3.6.1.4.1.485.3.7.2.2.1.5ColumnbscDeviceOutTransactionsread-onlymandatoryThe number of device transmitting transactions.
1.3.6.1.4.1.485.3.7.2.2.1.6ColumnbscDeviceSumCountread-onlymandatoryThe device sum count.
1.3.6.1.4.1.485.3.7.2.2.1.7ColumnbscDeviceResponseDelaySumread-onlymandatoryThe device sum count.
1.3.6.1.4.1.485.3.7.2.2.1.8ColumnbscDeviceResponseDelaySqSumread-onlymandatoryThe device sum count.
1.3.6.1.4.1.485.3.7.3NodedeviceALCGroup
1.3.6.1.4.1.485.3.7.3.1TablealcdeviceConfigTablenot-accessiblemandatoryA list of device entries.
1.3.6.1.4.1.485.3.7.3.1.1RowalcdeviceConfigEntrynot-accessiblemandatoryThis entry contains information about a given device. The entry is indexed by the port number, CU index, and device.
1.3.6.1.4.1.485.3.7.3.1.1.1ColumnalcdeviceConfigLineIndexread-onlymandatoryThe port number for which the line (CU)is configured (line level).
1.3.6.1.4.1.485.3.7.3.1.1.2ColumnalcdeviceConfigCUIndexread-onlymandatoryThe CU index which this device is configured on (CU level).
1.3.6.1.4.1.485.3.7.3.1.1.3ColumnalcdeviceConfigAddressread-onlymandatoryThe device address in the legal range of ALC poll addresses (device level). The range is 0x01 to 0x3c with 0x20 being invalid address. The default value is 0x0…
1.3.6.1.4.1.485.3.7.3.1.1.4ColumnalcdeviceConfigTyperead-onlymandatoryThe device type. The default value is printer.
1.3.6.1.4.1.485.3.8NodenodeT7Group
1.3.6.1.4.1.485.3.8.1Nodet7ConfigGroup
1.3.6.1.4.1.485.3.8.1.1Tablet7ConfigTablenot-accessiblemandatoryA table for T7 protocol configuration parameters.
1.3.6.1.4.1.485.3.8.1.1.1Rowt7ConfigEntrynot-accessiblemandatoryAn entry consisting of T7 protocol information for a particular port.
1.3.6.1.4.1.485.3.8.1.1.1.1Columnt7ConfigIndexread-onlymandatoryThe number that uniquely identifies this T7 port.
1.3.6.1.4.1.485.3.8.1.1.1.2Columnt7ProtocolEnabledread-onlymandatoryThis flag indicates if T7 protocol is enabled on this unit. If No, the following T7 variables will have no effect. The default value for this field is 'No'
1.3.6.1.4.1.485.3.8.1.1.1.3Columnt7PortSpeedread-onlymandatoryThe speed of the T7 port expressed in bits per second. The default speed is 75 bits per second
1.3.6.1.4.1.485.3.8.1.1.1.4Columnt7StopBitsread-onlymandatoryNumber of stop bits generated for T7 port transmit characters (received characters may have any number of bits regardless of the configuration). The default va…
1.3.6.1.4.1.485.3.8.1.1.1.5Columnt7PortParityread-onlymandatoryT7 port parity type generated for transmit characters and checked for receive characters. If ODD or EVEN, then if a character is received with invalid parity, …
1.3.6.1.4.1.485.3.8.1.1.1.6Columnt7DataBitsread-onlymandatoryT7 port number of data bit (not including the parity bit). The default value is 7
1.3.6.1.4.1.485.3.8.1.1.1.7Columnt7IdleTimerread-onlymandatoryThe T7 Idle timer is amount of time (in milliseconds) used to determine when a complete message has been received from the line. If configured as 0, then this …
1.3.6.1.4.1.485.3.8.1.1.1.8Columnt7PortTxFrameGapread-onlymandatoryThe T7 port TX frame gap is analogous to the idle timer, but is used to separate messages received from the network by gaps in time so that the Async device ca…
1.3.6.1.4.1.485.3.8.1.1.1.9Columnt7RxForwardingCountread-onlymandatoryThe T7 port receive forwarding count is used to forward messages when a configured number of characters is received from the Async line. This must be configure…
1.3.6.1.4.1.485.3.8.1.1.1.10Columnt7PortIPAddressread-onlymandatoryThe T7 port IP address is used to configure the remote IP address in which to communicate with.
1.3.6.1.4.1.485.3.8.1.1.1.11Columnt7UDPPortNumberread-onlymandatoryThe T7 port UDP port number address is used to configure the local and remot UDP port number (i.e. socket) address in which to communicate with. The default va…
1.3.6.1.4.1.485.3.8.2Nodet7StatsGroup
1.3.6.1.4.1.485.3.8.2.1Tablet7StatsTablenot-accessiblemandatoryA table of T7 protocol statistics information.
1.3.6.1.4.1.485.3.8.2.1.1Rowt7StatsEntrynot-accessiblemandatoryThis entry contains information about a T7 port. The entry is indexed by the port number, CU index, and device.
1.3.6.1.4.1.485.3.8.2.1.1.1Columnt7StatsIndexread-onlymandatoryThe number that uniquely identifies this T7 port.
1.3.6.1.4.1.485.3.8.2.1.1.2Columnt7InOctetsread-onlymandatoryThe number of bytes received.
1.3.6.1.4.1.485.3.8.2.1.1.3Columnt7OutOctetsread-onlymandatoryThe number of bytes sent.
1.3.6.1.4.1.485.3.8.2.1.1.4Columnt7InMessagesread-onlymandatoryThe number of messages received.
1.3.6.1.4.1.485.3.8.2.1.1.5Columnt7OutMessagesread-onlymandatoryThe number of messages sent.
1.3.6.1.4.1.485.3.8.2.1.1.6Columnt7InMsgDiscardedread-onlymandatoryThe number of received messages discarded.
1.3.6.1.4.1.485.3.8.2.1.1.7Columnt7OutMsgDiscardedread-onlymandatoryThe number of sent messages discarded.
1.3.6.1.4.1.485.3.8.2.1.1.8Columnt7XmtFailuresread-onlymandatoryThe number of failures in transmission.
1.3.6.1.4.1.485.3.8.2.1.1.9Columnt7RcvMsgForwardedread-onlymandatoryThe number of received messages forwarded.
1.3.6.1.4.1.485.3.8.2.1.1.10Columnt7RcvMsgErrorsread-onlymandatoryThe number of errors detected in receiving messages.
1.3.6.1.4.1.485.3.8.2.1.1.11Columnt7RcvCharsDiscardedread-onlymandatoryThe number of received characters discarded.
1.3.6.1.4.1.485.3.8.2.1.1.12Columnt7RcvParityErrorsread-onlymandatoryThe number of parity errors detected.
1.3.6.1.4.1.485.3.8.2.1.1.13Columnt7RcvFramingErrorsread-onlymandatoryThe number of errors detected in receiving frames.
1.3.6.1.4.1.485.3.8.2.1.1.14Columnt7RcvFifoOverrunsread-onlymandatoryThe number FIFO receive overruns detected.
1.3.6.1.4.1.485.3.8.2.1.1.15Columnt7RcvCharsOverrunsread-onlymandatoryThe number of character receive overruns detected.
1.3.6.1.4.1.485.3.8.2.1.1.16Columnt7RcvBreakConditionsread-onlymandatoryThe number of receive break conditions.
1.3.6.1.4.1.485.3.9NodenodeFrCirGroup
1.3.6.1.4.1.485.3.9.1TablefrExtCircuitTablenot-accessiblemandatoryA table containing information about specific Data Link Connection Identifiers and corresponding virtual circuits.
1.3.6.1.4.1.485.3.9.1.1RowfrExtCircuitEntrynot-accessiblemandatoryThe information regarding a single Data Link Connection Identifier.
1.3.6.1.4.1.485.3.9.1.1.1ColumnfrExtCircuitIfIndexread-onlymandatoryThe ifIndex Value of the ifEntry this virtual circuit is layered onto.
1.3.6.1.4.1.485.3.9.1.1.2ColumnfrExtCircuitDlciread-onlymandatoryThe Data Link Connection Identifier for this virtual circuit.
1.3.6.1.4.1.485.3.9.1.1.3ColumnfrExtCircuitStatusIgnoredread-writemandatoryThis field is used for consolidating status of the unit. The status of this circuit is not put into consideration when consolidating status of the unit if this…
1.3.6.1.4.1.485.3.9.1.1.4ColumnfrExtCircuitStatusAcknowledgedread-writemandatoryThis field is used for consolidating status of the unit. When this field is set to acknowledge, unit will re-consolidate its status without putting the status …
1.3.6.1.4.1.485.3.9.1.1.5ColumnfrExtCircuitPartnerIdread-onlymandatoryThis is the unit id of the FrameNode at the other end of the Frame relay PVC. It consists of a 1 to 8 octets right justified case-sensitive ASCII field which u…
1.3.6.1.4.1.485.3.9.1.1.6ColumnfrExtCircuitTxDeread-onlymandatoryTotal number of frames sent with DE bit for this PVC.
1.3.6.1.4.1.485.3.9.1.1.7ColumnfrExtCircuitRxDeread-onlymandatoryTotal number of frames received with the DE bit for this PVC.
1.3.6.1.4.1.485.3.9.1.1.8ColumnfrExtCircuitMinBitsread-onlymandatoryMinimum number of bits transmitted in Time Period Tc for this PVC.
1.3.6.1.4.1.485.3.9.1.1.9ColumnfrExtCircuitMaxBitsread-onlymandatoryMaximum number of bits transmitted in Time Period Tc for this PVC.
1.3.6.1.4.1.485.3.9.1.1.10ColumnfrExtCircuitQOctetsread-onlymandatoryNumber of octets queued for transmission because the maximum burst rate was achieved in Tc. These are the number of octets that had transmission delay until ne…
1.3.6.1.4.1.485.3.10NodenodeSlipGroup
1.3.6.1.4.1.485.3.10.1NodeslipConfigGroup
1.3.6.1.4.1.485.3.10.1.1TableslipConfigTablenot-accessiblemandatoryA table for Slip protocol configuration parameters.
1.3.6.1.4.1.485.3.10.1.1.1RowslipConfigEntrynot-accessiblemandatoryAn entry consisting of Slip protocol information for a particular port.
1.3.6.1.4.1.485.3.10.1.1.1.1ColumnslipConfigIndexread-onlymandatoryThe number that uniquely identifies this Slip port.
1.3.6.1.4.1.485.3.10.1.1.1.2ColumnslipProtocolEnabledread-onlymandatoryThis flag indicates if COM2 port is enabled or disabled for usage for SLIP. The default value for this field is 'Yes'
1.3.6.1.4.1.485.3.10.1.1.1.3ColumnslipPortSpeedread-onlymandatoryThis parameter determines the COM2 port speed for the SLIP connection to the modem. The default speed is 9600 bits per second
1.3.6.1.4.1.485.3.10.1.1.1.4ColumnslipStopBitsread-onlymandatoryThis parameter specifies the number of transmit Stop Bits used on the SLIP connection to the modem. The range of this parameter is 1 or 2 bits. The default val…
1.3.6.1.4.1.485.3.10.1.1.1.5ColumnslipIdleTimerread-onlymandatoryThe Slip Idle timer is amount of time (in milliseconds) used to determine the end of frame. The idel timer is started every time a character is received. The r…
1.3.6.1.4.1.485.3.10.1.1.1.6ColumnslipPortIPAddressread-onlymandatoryThe Slip port IP address. The default valus is 0.0.0.0.
1.3.6.1.4.1.485.3.10.1.1.1.7ColumnslipUsageread-onlymandatoryThis parameter defines whether SLIP protocol is used to manage locally attached modem or is it used for IP end node function or IP forwarding function. The ran…
1.3.6.1.4.1.485.3.10.1.1.1.8ColumnslipNetworkMaskread-onlymandatoryThis parameter defines IP sub-netmask for this parameter. The default valus is 0.0.0.0.
1.3.6.1.4.1.485.3.10.1.1.1.9ColumnslipDefaultGatewayread-onlymandatoryThis parameter defines IP default gateway. The default valus is 0.0.0.0.
1.3.6.1.4.1.485.3.10.1.1.1.10ColumnslipEnableRIPread-onlymandatoryThis parameter defines whether RIP packets should be sent on this interface or not. Range is yes or no. The default valus is 'no'.
1.3.6.1.4.1.485.3.10.2NodeslipStatsGroup
1.3.6.1.4.1.485.3.10.2.1TableslipStatsTablenot-accessiblemandatoryA table of Slip protocol statistics information.
1.3.6.1.4.1.485.3.10.2.1.1RowslipStatsEntrynot-accessiblemandatoryThis entry contains information about a slip Com port.
1.3.6.1.4.1.485.3.10.2.1.1.1ColumnslipStatsIndexread-onlymandatoryThe number that uniquely identifies this Slip com port.
1.3.6.1.4.1.485.3.10.2.1.1.2ColumnslipInChrsread-onlymandatoryThe number of Characters received.
1.3.6.1.4.1.485.3.10.2.1.1.3ColumnslipOutChrsread-onlymandatoryThe number of characters sent.
1.3.6.1.4.1.485.3.10.2.1.1.4ColumnslipInMessagesread-onlymandatoryThe number of messages received.
1.3.6.1.4.1.485.3.10.2.1.1.5ColumnslipOutMessagesread-onlymandatoryThe number of messages sent.
1.3.6.1.4.1.485.3.10.2.1.1.6ColumnslipInMsgDiscardedread-onlymandatoryThe number of received messages discarded.
1.3.6.1.4.1.485.3.10.2.1.1.7ColumnslipOutMsgDiscardedread-onlymandatoryThe number of sent messages discarded.
1.3.6.1.4.1.485.3.10.2.1.1.8ColumnslipXmtFailuresread-onlymandatoryThe number of failures in transmission.
1.3.6.1.4.1.485.3.10.2.1.1.9ColumnslipRcvMsgForwardedread-onlymandatoryThe number of received messages forwarded.
1.3.6.1.4.1.485.3.10.2.1.1.10ColumnslipRcvMsgErrorsread-onlymandatoryThe number of errors detected in receiving messages.
1.3.6.1.4.1.485.3.10.2.1.1.11ColumnslipRcvCharsDiscardedread-onlymandatoryThe number of received characters discarded.
1.3.6.1.4.1.485.3.10.2.1.1.12ColumnslipRcvParityErrorsread-onlymandatoryThe number of parity errors detected.
1.3.6.1.4.1.485.3.10.2.1.1.13ColumnslipRcvFramingErrorsread-onlymandatoryThe number of errors detected in receiving frames.
1.3.6.1.4.1.485.3.10.2.1.1.14ColumnslipRcvFifoOverrunsread-onlymandatoryThe number FIFO receive overruns detected.
1.3.6.1.4.1.485.3.10.2.1.1.15ColumnslipRcvCharsOverrunsread-onlymandatoryThe number of character receive overruns detected.
1.3.6.1.4.1.485.3.10.2.1.1.16ColumnslipRcvBreakConditionsread-onlymandatoryThe number of receive break conditions.
1.3.6.1.4.1.485.3.11NodenodeIpxGroup
1.3.6.1.4.1.485.3.11.1NodeipxConfigGroup
1.3.6.1.4.1.485.3.11.1.1ScalaripxEnableRoutingread-onlymandatoryThis parameter determines whether or not IPX Routing is enabled. Thr range of this parameter is yes or no. If set to yes, the parameter 'Filter IPX' should be …
1.3.6.1.4.1.485.3.11.1.2ScalaripxRoutedTxPriorityread-onlymandatoryThis parameter governs the transmission priority of the routed IPX frames for Frame Relay port(s). The range is URGENT, HIGH, MEDIUM AND LOW. The default is se…
1.3.6.1.4.1.485.3.11.1.3ScalaripxEnableRipBroadcastread-onlymandatoryThis parameter governs whether the framenode should send RIP packets or not. The range of this parameter is YES or NO. If IPX routing is disabled, this paramet…
1.3.6.1.4.1.485.3.11.1.4ScalaripxEnableSapBroadcastread-onlymandatoryThis parameter governs whether the framenode should send SAP packets. The range of this parameter is YES or NO. If IPX routing is disabled, this parameter is i…
1.3.6.1.4.1.485.3.11.1.5ScalaripxEnableNetBIOSread-onlymandatoryThis parameter governs whether the frame Node should process NetBIOS packets or not. The range of this parameter is Yes or No. If IPX Routing is disabled, this…
1.3.6.1.4.1.485.3.11.1.6ScalaripxGlobalNodeIdread-onlymandatoryBy default FrameNode always implements IPX WAN over Frame Relay. The 'timer request' packet is transmitted by the FrameNode over Frame Relay. This packet inclu…
1.3.6.1.4.1.485.3.12NodenodeIpGroup
1.3.6.1.4.1.485.3.12.1NodeipConfigGroup
1.3.6.1.4.1.485.3.12.1.1ScalarpriIPHelperAddressread-onlymandatoryThis is the Primary IP Helper Address of this unit.
1.3.6.1.4.1.485.3.12.1.2ScalarsecIPHelperAddressread-onlymandatoryThis is the Secondary IP Helper Address of this unit.
1.3.6.1.4.1.485.3.12.1.3ScalarinternalIPAddrread-onlymandatoryThe range of this parameter and the default value is same as other IP Address in the unit.
1.3.6.1.4.1.485.3.12.1.4ScalarinternalIPNetmaskread-onlymandatoryThis is the Internal IP network mask.
1.3.6.1.4.1.485.3.12.1.5ScalarenableIpRoutingread-onlymandatoryThis is the Internal IP network mask.
1.3.6.1.4.1.485.3.12.1.6ScalarenableIpBridgingread-onlymandatoryThis is the Internal IP network mask.
1.3.6.1.4.1.485.3.12.1.7ScalarenableRipBroadcastread-onlymandatoryThis is the Internal IP network mask.
1.3.6.1.4.1.485.800NodeconfigChangedThis trap indicates that the configuration of the unit has been changed.
1.3.6.1.4.1.485.801NodeconfigErrorThis trap indicates that the activation of configuration of the unit has resulted in an error. New configuration has not been successfully activated.
1.3.6.1.4.1.485.802NodedumpExistsThis trap indicates that a memory core dump exists.
1.3.6.1.4.1.485.803NodedumpArchivedThis trap indicates that the memory dump file has been archived.
1.3.6.1.4.1.485.804NodelineStatusChangedThis trap indicates that the indicated Line or Port has changed state. It has either been enabled, failed or disabled.
1.3.6.1.4.1.485.805NodelanStatusChangedThis trap indicates that the indicated LAN Port has changed state. It has either been enabled, failed or disabled.
1.3.6.1.4.1.485.806NodelineQualityThis trap indicates that the line quality is changed. If the lineQualityAborts is greater than 5 or lineQualityCRCErrors is greater that 5 then it indicates a …
1.3.6.1.4.1.485.807NodepuStatusChangedThis trap indicates that the indicated PU has changed state. It has either been enabled, failed or disabled.
1.3.6.1.4.1.485.808NodepuConnectionStatusChangedNote this trap is obsolete. This trap indicates that the indicated PU has changed connection state. Its connection has either been established, disconnected, o…
1.3.6.1.4.1.485.809NodenetviewConnectionStatusChangedNote this trap is obsolete. This trap indicates that the NetView PU has changed connection state. Its connection has either been established, disconnected, or …
1.3.6.1.4.1.485.810NodenetviewAltConnectionStatusChangedNote this trap is obsolete. This trap indicates that the Alternate NetView PU has changed connection state. Its connection has either been established, disconn…
1.3.6.1.4.1.485.811NodepuConnectionStatusUpThis trap is obsolete. This trap indicates that the indicated PU has changed connection state. Its connection had been established.
1.3.6.1.4.1.485.812NodepuConnectionStatusDownThis trap is obsolete. This trap indicates that the indicated PU has changed connection state. Its connection has been disconnected. If the indicated PU is not…
1.3.6.1.4.1.485.813NodenetviewConnectionStatusUpThis trap is obsolete. This trap indicates that the indicated NetView PU has changed connection state. Its connection has been established.
1.3.6.1.4.1.485.814NodenetviewConnectionStatusDownThis trap is obsolete. This trap indicates that the indicated NetView PU has changed connection state. Its connection had been disconnected. If the indicated P…
1.3.6.1.4.1.485.815NodenetviewAltConnectionStatusUpThis trap is obsolete. This trap indicates that the indicated Alternate NetView PU has changed connection state. Its connection has been established.
1.3.6.1.4.1.485.816NodenetviewAltConnectionStatusDownThis trap is obsolete. This trap indicates that the indicated Alternate NetView PU has changed connection state. Its connection had been disconnected. If the i…
1.3.6.1.4.1.485.817NodesessSwitchedToPrimaryDLCIThis trap indicates that a session switch has occured from a Parallel DLCI to Primary DLCI.
1.3.6.1.4.1.485.818NodesessSwitchedToParallelDLCIThis trap indicates that a session switch has occured from the Primary DLCI to the Parallel DLCI.
1.3.6.1.4.1.485.819NodesessUpOnPrimaryDLCIThis indicates that a PU session is established on a primary DLCI. This TRAP is generated for Frame Nodes only. For Conversion Node sessUpOnPrimaryMAC or sessU…
1.3.6.1.4.1.485.820NodesessUpOnParallelDLCIThis indicates that a PU session is established on a parallel DLCI. This TRAP is generated for Frame Nodes only. For Conversion Node sessUpOnPrimaryMAC or sess…
1.3.6.1.4.1.485.821NodesessUpOnAlternateDLCIThis indicates that a PU session is established on an alternate DLCI. This TRAP is generated for Frame Nodes only. For Conversion Node sessUpOnPrimaryMAC or se…
1.3.6.1.4.1.485.822NodesessUpOnPrimaryMACThis indicates that a PU session is established on a non-explicit (dynamic, or broadcast) DLCI to the primary destination MAC. For Conversion Node, puCurrentDl…
1.3.6.1.4.1.485.823NodesessUpOnAlternateMACThis indicates that a PU session is established on a non-explicit (dynamic, or broadcast) DLCI to the alternate destination MAC, if configured. For Conversion …
1.3.6.1.4.1.485.824NodesessDownOnPrimaryMACThis trap indicates that the session for the indicated PU associated with the primary destination MAC was cleared. If the indicated PU is not in session, the t…
1.3.6.1.4.1.485.825NodesessDownOnAlternateMACThis trap indicates that the session for the indicated PU associated with the alternate destination MAC, if configured, was cleared. If the indicated PU is not…
1.3.6.1.4.1.485.826NodelostUNIThis trap indicates that the indicated Frame Relay Line or Port has lost its UNI connectivity to the Frame Relay network.
1.3.6.1.4.1.485.827NoderestoredUNIThis trap indicates that the indicated Frame Relay Line or Port has restored its UNI connectivity to the Frame Relay network.
1.3.6.1.4.1.485.828NodeswitchedToBackupThis trap indicates that the indicated Frame Relay Line or Port has successfully switched to switched backup connection.
1.3.6.1.4.1.485.829NodeswitchedToDedThis trap indicates that the indicated Frame Relay Line or Port has successfully switched to the dedicated Frame Relay connection to the network.
1.3.6.1.4.1.485.830NodedialConnStatusChangedThis trap indicates that the indicated dial backup connection has changed state. It has either been connected or disconnected.
1.3.6.1.4.1.485.831NodesessUpOnSVCThis trap indicates that the session for the indicated PU or LAN PU associated with the remote DTE address was established.
1.3.6.1.4.1.485.832NodesessDownOnSVCThis trap indicates that the session for the indicated PU or LAN PU associated with the last remote DTE address was cleared. If the indicated PU/LAN PU is not …
Type Definitions
NameSyntaxStatusDescription
DisplayStringOCTET STRING
PhysAddressOCTET STRING