TELDAT-CFG-INTERF-IEC101GW-MIB
24 objects
No module-level DESCRIPTION found.
Imported Objects
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.2007.4.1.1.4.16 | NodetelProdNpConfInterfIec101GW | |||
| 1.3.6.1.4.1.2007.4.1.1.4.16.1 | TabletelProdNpIec101GWTable | not-accessible | mandatory | Table of global configuration for IEC101 GW interfaces. Each row represents an interface |
| 1.3.6.1.4.1.2007.4.1.1.4.16.1.1 | RowtelProdNpIec101GWEntry | not-accessible | mandatory | A base list of objects that are configuration information about an IEC101 GW interface. The index is the number of the interface. |
| 1.3.6.1.4.1.2007.4.1.1.4.16.1.1.1 | ColumntelProdNpIec101GWIfcIndex | read-only | mandatory | IEC101-GW interface index. It is the index table. |
| 1.3.6.1.4.1.2007.4.1.1.4.16.1.1.2 | ColumntelProdNpIec101GWIfcAsduCAddr | read-write | mandatory | Set RTU ASDU common Adress for no multilink mode. |
| 1.3.6.1.4.1.2007.4.1.1.4.16.1.1.3 | ColumntelProdNpIec101GWIfcBaudRate | read-write | mandatory | Set baud reate for serial interface. |
| 1.3.6.1.4.1.2007.4.1.1.4.16.1.1.4 | ColumntelProdNpIec101GWIfcLinkAddr | read-write | mandatory | Set RTU Link Adress for no multilink mode. |
| 1.3.6.1.4.1.2007.4.1.1.4.16.1.1.5 | ColumntelProdNpIec101GWIfcLinkAddrSz | read-write | mandatory | Set Link Adress field size. |
| 1.3.6.1.4.1.2007.4.1.1.4.16.1.1.6 | ColumntelProdNpIec101GWIfcLongResp | read-write | mandatory | Enable sends long frame responses to RTU's. |
| 1.3.6.1.4.1.2007.4.1.1.4.16.1.1.7 | ColumntelProdNpIec101GWIfcMultilink | read-write | mandatory | Enable RTU's multilink mode. |
| 1.3.6.1.4.1.2007.4.1.1.4.16.1.1.8 | ColumntelProdNpIec101GWIfcBuffNum | read-write | mandatory | Configure number of IEC-101 transmission buffers. |
| 1.3.6.1.4.1.2007.4.1.1.4.16.1.1.9 | ColumntelProdNpIec101GWIfcOrigAddr | read-write | mandatory | Configure IEC-101 Originator Address. |
| 1.3.6.1.4.1.2007.4.1.1.4.16.1.1.10 | ColumntelProdNpIec101GWIfcRetransMax | read-write | mandatory | Configure maximum number of IEC-101 messages retransmissions. |
| 1.3.6.1.4.1.2007.4.1.1.4.16.1.1.11 | ColumntelProdNpIec101GWIfcRetransTime | read-write | mandatory | Configure time for IEC-101 messages retransmissions. Time in milliseconds |
| 1.3.6.1.4.1.2007.4.1.1.4.16.1.1.12 | ColumntelProdNpIec101GWIfcRxTimeout | read-write | mandatory | Configure input frame timeout. Time in milliseconds |
| 1.3.6.1.4.1.2007.4.1.1.4.16.1.1.13 | ColumntelProdNpIec101GWIfcSyncTime | read-write | mandatory | Configure period time to sent IEC-101 Synchronization message to RTU. Time in minutes |
| 1.3.6.1.4.1.2007.4.1.1.4.16.1.1.14 | ColumntelProdNpIec101GWIfcTestTime | read-write | mandatory | Configure period time to sent IEC-101 Link Test message to RTU. Time in seconds |
| 1.3.6.1.4.1.2007.4.1.1.4.16.1.1.15 | ColumntelProdNpIec101GWIfcTestType | read-write | mandatory | Configure type of IEC-101 Link Test message to send to RTU. 0 Don't send message, 1 Send Test message, 2 Send Status message. |
| 1.3.6.1.4.1.2007.4.1.1.4.16.2 | TabletelProdNpIec101GWIfcRtuTable | not-accessible | mandatory | Table of RTU Link Address configuration for IEC101 GW interfaces. There are two table indexes: the interface and the RTU index. |
| 1.3.6.1.4.1.2007.4.1.1.4.16.2.1 | RowtelProdNpIec101GWIfcRtuEntry | not-accessible | mandatory | Each entry contains an RTU link address. Each entry consist on an interfece index and an RTU index. |
| 1.3.6.1.4.1.2007.4.1.1.4.16.2.1.1 | ColumntelProdNpIec101GWIfcRtuIfcIndex | read-only | mandatory | IEC101-GW interface index. It is the index table. |
| 1.3.6.1.4.1.2007.4.1.1.4.16.2.1.2 | ColumntelProdNpIec101GWIfcRtuIndex | read-only | mandatory | RTU table index. |
| 1.3.6.1.4.1.2007.4.1.1.4.16.2.1.3 | ColumntelProdNpIec101GWIfcRtuStatus | read-write | mandatory | Table control variable. Set to 1 does nothing. Set to 2 adds a new row (RTU link address) in the table with default value(65534) and returns 2. If it already e… |
| 1.3.6.1.4.1.2007.4.1.1.4.16.2.1.4 | ColumntelProdNpIec101GWIfcRtuAddress | read-write | mandatory | Set link address for a RTU in multilink mode. RTU link address can not be repeated. If address already exists, then it returns error. |