TELDAT-CFG-PROTOCOL-GW104-MIB

32 objects
No module-level DESCRIPTION found.
OIDNameAccessStatusDescription
1.3.6.1.4.1.2007.4.1.1.5.14NodetelProdNpConfProtGW104
1.3.6.1.4.1.2007.4.1.1.5.14.1NodetelProdNpGW104Global
1.3.6.1.4.1.2007.4.1.1.5.14.1.1ScalartelProdNpGW104GloEnableread-writemandatoryEnables Gateway IEC-104/101 operation.
1.3.6.1.4.1.2007.4.1.1.5.14.1.2ScalartelProdNpGW104Glo101-Onread-writemandatoryEnables IEC-101 operation regardless IEC-104 agents status.
1.3.6.1.4.1.2007.4.1.1.5.14.1.3ScalartelProdNpGW104Glo104-Onread-writemandatoryEnables IEC-104 agents operation regardless IEC-101 interfaces status.
1.3.6.1.4.1.2007.4.1.1.5.14.1.4ScalartelProdNpGW104GloASDUComAddrread-writemandatorySet ASDU Common Address field value.
1.3.6.1.4.1.2007.4.1.1.5.14.1.5ScalartelProdNpGW104GloASDUComAddrSzread-writemandatorySet ASDU Common Address field size.
1.3.6.1.4.1.2007.4.1.1.5.14.1.6ScalartelProdNpGW104GloCauseTransfSzread-writemandatorySet Cause of Transfer field size.
1.3.6.1.4.1.2007.4.1.1.5.14.1.7ScalartelProdNpGW104GloInfoObjAddrSzread-writemandatorySet Information Object Address field size.
1.3.6.1.4.1.2007.4.1.1.5.14.1.8ScalartelProdNpGW104GloIoa10000read-writemandatoryEnable use of IOA 10000.
1.3.6.1.4.1.2007.4.1.1.5.14.1.9ScalartelProdNpGW104GloIoa10007read-writemandatoryEnable use of IOA 10007.
1.3.6.1.4.1.2007.4.1.1.5.14.1.10ScalartelProdNpGW104GloOrigFilterread-writemandatoryEnable originator address filter for messages received from Control Center .
1.3.6.1.4.1.2007.4.1.1.5.14.2TabletelProdNpGW104AgentTablenot-accessiblemandatoryAgents list. The table index is the Agent position.
1.3.6.1.4.1.2007.4.1.1.5.14.2.1RowtelProdNpGW104AgentEntrynot-accessiblemandatoryEach entry consists in an IEC-104 Agent. Each entry contains the corresponding IEC-104 agent configuration.
1.3.6.1.4.1.2007.4.1.1.5.14.2.1.1ColumntelProdNpGW104AgentIndexread-onlymandatoryIEC-104 agent position in the table.
1.3.6.1.4.1.2007.4.1.1.5.14.2.1.2ColumntelProdNpGW104AgentStatusread-writemandatoryTable control variable. Set to 1 does nothing. Set to 2 adds a new row (IEC-104 Agent) in the table with default values and returns 2. If it already exists, th…
1.3.6.1.4.1.2007.4.1.1.5.14.2.1.3ColumntelProdNpGW104AgentNameread-writemandatoryIEC-104 agent name. Agents names must be different, can not be repeated. If name already exists, then it returns error.
1.3.6.1.4.1.2007.4.1.1.5.14.2.1.4ColumntelProdNpGW104AgentAlarmBufread-writemandatoryAlarm buffer queue length.
1.3.6.1.4.1.2007.4.1.1.5.14.2.1.5ColumntelProdNpGW104AgentKread-writemandatoryMax. number of IEC-104 send messages without confirmation.
1.3.6.1.4.1.2007.4.1.1.5.14.2.1.6ColumntelProdNpGW104AgentLocTcpPortread-writemandatoryLocal TCP port for IEC-104 agent listen.
1.3.6.1.4.1.2007.4.1.1.5.14.2.1.7ColumntelProdNpGW104AgentT0read-writemandatoryT0 defined by IEC-104, establish connection timeout. Value indicates in seconds.
1.3.6.1.4.1.2007.4.1.1.5.14.2.1.8ColumntelProdNpGW104AgentT1read-writemandatoryT1 defined by IEC-104, SEND or TEST APDU type timeout. Value indicates in seconds.
1.3.6.1.4.1.2007.4.1.1.5.14.2.1.9ColumntelProdNpGW104AgentT2read-writemandatoryT2 defined by IEC-104, data message confirmation timeout. Value indicates in seconds.
1.3.6.1.4.1.2007.4.1.1.5.14.2.1.10ColumntelProdNpGW104AgentT3read-writemandatoryT3 defined by IEC-104, sending S message timeout on long inactivity periods. Value indicates in seconds.
1.3.6.1.4.1.2007.4.1.1.5.14.2.1.11ColumntelProdNpGW104AgentWread-writemandatoryMax. number of IEC-104 received messages confirmed.
1.3.6.1.4.1.2007.4.1.1.5.14.2.1.12ColumntelProdNpGW104AgentVrfread-writemandatoryVRF name. If VRF is configured on router, can be asociate in agent. Return error if VRF name don't exist.
1.3.6.1.4.1.2007.4.1.1.5.14.3TabletelProdNpGW104AgentCcIpTablenot-accessiblemandatoryAgents list. The table index is the Agent position.
1.3.6.1.4.1.2007.4.1.1.5.14.3.1RowtelProdNpGW104AgentCcIpEntrynot-accessiblemandatoryEach entry contains a Control Center IP address for an IEC-104 Agent. First index indicates IEC-104 Agent this value must correspond with same in Agent global …
1.3.6.1.4.1.2007.4.1.1.5.14.3.1.1ColumntelProdNpGW104AgentCcIpAgIndexread-onlymandatoryIEC-104 agent position index, must be the same that agents table.
1.3.6.1.4.1.2007.4.1.1.5.14.3.1.2ColumntelProdNpGW104AgentCcIpIndexread-onlymandatoryControl Center IP address position in the table.
1.3.6.1.4.1.2007.4.1.1.5.14.3.1.3ColumntelProdNpGW104AgentCcIpStatusread-writemandatoryTable control variable. Set to 1 does nothing. Set to 2 deletes corresponding Control Center IP address to that Agent. Get returns 1 if the control exists. It …
1.3.6.1.4.1.2007.4.1.1.5.14.3.1.4ColumntelProdNpGW104AgentCcIpAddrread-writemandatoryControl Center IP address for IEC-104 agents filter. Adding a new IP address, that don't exist in the table, create a new row in the table.