TELDAT-MON-FEATURES-TIDP-MASTER-MIB
19 objects
No module-level DESCRIPTION found.
Imported Objects
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.2007.4.1.2.4.5 | NodetelProdNpMonFeatTidpMaster | |||
| 1.3.6.1.4.1.2007.4.1.2.4.5.1 | NodetidpMasterGlobalGroup | |||
| 1.3.6.1.4.1.2007.4.1.2.4.5.1.1 | ScalartidpMasterGlobalStatus | read-only | mandatory | Indicates whether the TIDP MASTER function is enabled or not. Possible values are: (1) enabled or (2) disabled. |
| 1.3.6.1.4.1.2007.4.1.2.4.5.1.2 | ScalartidpMasterGlobalMaxStations | read-only | mandatory | Maximum number of managed stations (routers). |
| 1.3.6.1.4.1.2007.4.1.2.4.5.1.3 | ScalartidpMasterGlobalUsedEntries | read-only | mandatory | Number of used entries. |
| 1.3.6.1.4.1.2007.4.1.2.4.5.1.4 | ScalartidpMasterGlobalHostnameIsHere | read-write | mandatory | Hostname whose position index is required. This variable is used in conjunction with tidpMasterGlobalEquipmentPosition. |
| 1.3.6.1.4.1.2007.4.1.2.4.5.1.5 | ScalartidpMasterGlobalEquipmentPosition | read-only | mandatory | Position index in the table of the equipment entry associated to the hostname specified in tidpMasterGlobalHostnameIsHere (0 if not present). |
| 1.3.6.1.4.1.2007.4.1.2.4.5.1.6 | ScalartidpMasterGlobalSerialIsHere | read-write | mandatory | Serial number whose position index is required. This variable is used in conjunction with tidpMasterGlobalEquipmentPosition. |
| 1.3.6.1.4.1.2007.4.1.2.4.5.2 | TabletidpMasterEquipmentTable | not-accessible | mandatory | This table includes the routers being managed or trying to manage. The maximum number of items in the table is limited by tidpMasterGlobalMaxStations. |
| 1.3.6.1.4.1.2007.4.1.2.4.5.2.1 | RowtidpMasterEquipmentEntry | not-accessible | mandatory | Each entry contains information about the equipment being managed. |
| 1.3.6.1.4.1.2007.4.1.2.4.5.2.1.1 | ColumntidpMasterEquipmentIndex | read-only | mandatory | Table index: order number of the entry or equipment being managed by the TIDP Master. |
| 1.3.6.1.4.1.2007.4.1.2.4.5.2.1.2 | ColumntidpMasterEquipmentStatus | read-only | mandatory | Entry status: (0) initial: no operation is being performed. (1) waiting: the management process has begun and is running and the TIDP Master is waiting to get … |
| 1.3.6.1.4.1.2007.4.1.2.4.5.2.1.3 | ColumntidpMasterEquipmentCommand | read-write | mandatory | Command to be performed: (1) manage: begin management process (write-only). (2) delete: end management process (write-only). (3) ok: last command has been perf… |
| 1.3.6.1.4.1.2007.4.1.2.4.5.2.1.4 | ColumntidpMasterEquipmentHostname | read-write | mandatory | Hostname of the equipment being managed. The management process can be performed using hostname or serial number. If it is going to be based on hostname, this … |
| 1.3.6.1.4.1.2007.4.1.2.4.5.2.1.5 | ColumntidpMasterEquipmentAddress | read-only | mandatory | Router IP address. This variable is readable when tidpMasterEquipmentStatus is managing(2). Otherwise its value is 0.0.0.0 (until the managed router is reachab… |
| 1.3.6.1.4.1.2007.4.1.2.4.5.2.1.6 | ColumntidpMasterEquipmentSerial | read-write | mandatory | Serial number of the equipment being managed. The management process can be performed using hostname or serial number. If it is going to be based on serial num… |
| 1.3.6.1.4.1.2007.4.1.2.4.5.2.1.7 | ColumntidpMasterEquipmentManagementType | read-write | mandatory | Management type: (1) manual: manual operation. (2) automatic: automatic operation. |
| 1.3.6.1.4.1.2007.4.1.2.4.5.2.1.8 | ColumntidpMasterEquipmentManagerIdentifier | read-write | mandatory | Manager identifier. It is usually the IP address of the management station that requested the router management. |
| 1.3.6.1.4.1.2007.4.1.2.4.5.2.1.9 | ColumntidpMasterEquipmentError | read-only | mandatory | If the value of this variable is not 0 (none, not error) when the variable tidpMasterEquipmentStatus takes the value 2 (managing) something went wrong during m… |