| 1.3.6.1.4.1.2007.4.1.2.2.2.9 | NodetelProdNpMonInterfFR | |||
| 1.3.6.1.4.1.2007.4.1.2.2.2.9.1 | TabletelProdNpMonInterfFRGlobalTable | not-accessible | mandatory | Table of general information about interfaces Frame Relay. This information is not available for FR-Dial or FR over RDSI interfaces. The entry number is determ… |
| 1.3.6.1.4.1.2007.4.1.2.2.2.9.1.1 | RowtelProdNpMonInterfFRGlobalEntry | not-accessible | mandatory | Each entry consists of the interface number of the node, that is the table index, the interface type or physical driver (DTE o DCE) used by Frame Relay, the li… |
| 1.3.6.1.4.1.2007.4.1.2.2.2.9.1.1.1 | ColumntelProdNpMonInterfFRGloIndex | read-only | mandatory | Node interface number, that indicates the table entry (table index). |
| 1.3.6.1.4.1.2007.4.1.2.2.2.9.1.1.2 | ColumntelProdNpMonInterfFRGloDriverType | read-only | mandatory | FR interface type: (1) DCE, (2) DTE. |
| 1.3.6.1.4.1.2007.4.1.2.2.2.9.1.1.3 | ColumntelProdNpMonInterfFRGloLineSpeed | read-only | mandatory | Line data rate, expressed in bits per second. The value 0 indicates unknown speed. |
| 1.3.6.1.4.1.2007.4.1.2.2.2.9.1.1.4 | ColumntelProdNpMonInterfFRGloLastResetWeek | read-only | mandatory | Weeks passed since the last port reset. |
| 1.3.6.1.4.1.2007.4.1.2.2.2.9.1.1.5 | ColumntelProdNpMonInterfFRGloLastResetDay | read-only | mandatory | Days passed since the last port reset: spare days after counting weeks, that do not form a complete week, that means the variable value will be always lower th… |
| 1.3.6.1.4.1.2007.4.1.2.2.2.9.1.1.6 | ColumntelProdNpMonInterfFRGloLastResetHour | read-only | mandatory | Hours passed since the last port reset. If more than a week has passed, this variable indicates the number hours to add to the number of weeks and days, and it… |
| 1.3.6.1.4.1.2007.4.1.2.2.2.9.1.1.7 | ColumntelProdNpMonInterfFRGloLastResetMin | read-only | mandatory | Minutes passed since the last port reset. This variable indicates the number of minutes since the last hour was added to the hour counter. |
| 1.3.6.1.4.1.2007.4.1.2.2.2.9.1.1.8 | ColumntelProdNpMonInterfFRGloLastResetSec | read-only | mandatory | Seconds passed since the last port reset. The total time passed will be the addition of weeks, days, hours, minutes and seconds since the last reset. |
| 1.3.6.1.4.1.2007.4.1.2.2.2.9.2 | TabletelProdNpMonInterfFRRS232Table | not-accessible | mandatory | Table of RS232 signals or circuits. It shows if the corresponding signal is active. This table does not exist for FR-Dial or FR over ISDN interfaces. The entry… |
| 1.3.6.1.4.1.2007.4.1.2.2.2.9.2.1 | RowtelProdNpMonInterfFRRS232Entry | not-accessible | mandatory | Each entry consists of the node interface number, that is the table index, the order number of the circuit in that interface (second index), that goes between … |
| 1.3.6.1.4.1.2007.4.1.2.2.2.9.2.1.1 | ColumntelProdNpMonInterfFRRS232Index | read-only | mandatory | Node interface number. It is the first table index. |
| 1.3.6.1.4.1.2007.4.1.2.2.2.9.2.1.2 | ColumntelProdNpMonInterfFRRS232CircIndex | read-only | mandatory | Second table index. It is a number that goes between 1 and the maximum number of this type of circuits, that varies with the connector. |
| 1.3.6.1.4.1.2007.4.1.2.2.2.9.2.1.3 | ColumntelProdNpMonInterfFRRS232Circuit | read-only | mandatory | RS232 circuit number. |
| 1.3.6.1.4.1.2007.4.1.2.2.2.9.2.1.4 | ColumntelProdNpMonInterfFRRS232Nickname | read-only | mandatory | Circuit name. |
| 1.3.6.1.4.1.2007.4.1.2.2.2.9.2.1.5 | ColumntelProdNpMonInterfFRRS232State | read-only | mandatory | Signal (of the circuits) status: on, off or unknown. |
| 1.3.6.1.4.1.2007.4.1.2.2.2.9.3 | TabletelProdNpMonInterfFRFramesTable | not-accessible | mandatory | Table of counters of output frames and errors on input frames. This information is not available for FR-Dial or FR over ISDN interfaces. The entry number is de… |
| 1.3.6.1.4.1.2007.4.1.2.2.2.9.3.1 | RowtelProdNpMonInterfFRFramesEntry | not-accessible | mandatory | Each entry consists of the node interface number, which is the table index, a variable that shows the output of the last table delete attempt (get operation) o… |
| 1.3.6.1.4.1.2007.4.1.2.2.2.9.3.1.1 | ColumntelProdNpMonInterfFRFramesIndex | read-only | mandatory | Node interface number, which shows the corresponding table entry (it is the table index). |
| 1.3.6.1.4.1.2007.4.1.2.2.2.9.3.1.2 | ColumntelProdNpMonInterfFRFramesClear | read-write | mandatory | This variable when is read shows the output from the last table delete attempt: the value is 2 if the deletion was performed succesfully, 3 if an error ocurred… |
| 1.3.6.1.4.1.2007.4.1.2.2.2.9.3.1.3 | ColumntelProdNpMonInterfFRFramesCRCError | read-only | mandatory | Number of frames with CRC errors. |
| 1.3.6.1.4.1.2007.4.1.2.2.2.9.3.1.4 | ColumntelProdNpMonInterfFRFramesMissed | read-only | mandatory | Number of incoming frames lost due to overrun. |
| 1.3.6.1.4.1.2007.4.1.2.2.2.9.3.1.5 | ColumntelProdNpMonInterfFRFramesAborted | read-only | mandatory | Number of incoming frames aborted. |
| 1.3.6.1.4.1.2007.4.1.2.2.2.9.3.1.6 | ColumntelProdNpMonInterfFRFramesAlignment | read-only | mandatory | Number of incoming frames with alignment errors. |
| 1.3.6.1.4.1.2007.4.1.2.2.2.9.3.1.7 | ColumntelProdNpMonInterfFRFramesTooLong | read-only | mandatory | Number of too long incoming frames. |
| 1.3.6.1.4.1.2007.4.1.2.2.2.9.3.1.8 | ColumntelProdNpMonInterfFRFramesOverrun | read-only | mandatory | Number of DMA/FIFO overrun. |
| 1.3.6.1.4.1.2007.4.1.2.2.2.9.3.1.9 | ColumntelProdNpMonInterfFRFramesUnderrun | read-only | mandatory | Number of DMA/FIFO overrun. |
| 1.3.6.1.4.1.2007.4.1.2.2.2.9.3.1.10 | ColumntelProdNpMonInterfFRFramesTxAbort | read-only | mandatory | Number of aborted outputs sent. |
| 1.3.6.1.4.1.2007.4.1.2.2.2.9.4 | NodetelProdNpMonInterfFRCompGroup | |||
| 1.3.6.1.4.1.2007.4.1.2.2.2.9.4.1 | TabletelProdNpMonInterfFRCompStatTable | not-accessible | mandatory | This table contains compression statistics of Frame Relay, FR-Dial and FR over ISDN interfaces. The entry number is determined by the interface value (first ta… |
| 1.3.6.1.4.1.2007.4.1.2.2.2.9.4.1.1 | RowtelProdNpMonInterfFRCompStatEntry | not-accessible | mandatory | Each entry consists of the interface number, which is the first table index, the dlci number whose statistics are of interest (second index), a variable that s… |
| 1.3.6.1.4.1.2007.4.1.2.2.2.9.4.1.1.1 | ColumntelProdNpMonInterfFRCStatIfcIndex | read-only | mandatory | Node interface number. It is the first table index. |
| 1.3.6.1.4.1.2007.4.1.2.2.2.9.4.1.1.2 | ColumntelProdNpMonInterfFRCStatDlciIndex | read-only | mandatory | Dlci number in the interface. It is the second table index. |
| 1.3.6.1.4.1.2007.4.1.2.2.2.9.4.1.1.3 | ColumntelProdNpMonInterfFRCStatClear | read-write | mandatory | This variable when is read shows the output from the last table delete attempt: the value is 2 if the deletion was performed succesfully, 3 if an error ocurred… |
| 1.3.6.1.4.1.2007.4.1.2.2.2.9.4.1.1.4 | ColumntelProdNpMonInterfFRCStatManFrComp | read-only | mandatory | Number of frames managed in compression. |
| 1.3.6.1.4.1.2007.4.1.2.2.2.9.4.1.1.5 | ColumntelProdNpMonInterfFRCStatManByComp | read-only | mandatory | Number of bytes managed in compression. |
| 1.3.6.1.4.1.2007.4.1.2.2.2.9.4.1.1.6 | ColumntelProdNpMonInterfFRCStatProcFrComp | read-only | mandatory | Number of frames processed in compression. |
| 1.3.6.1.4.1.2007.4.1.2.2.2.9.4.1.1.7 | ColumntelProdNpMonInterfFRCStatProcByComp | read-only | mandatory | Number of bytes processed in compression. |
| 1.3.6.1.4.1.2007.4.1.2.2.2.9.4.1.1.8 | ColumntelProdNpMonInterfFRCStatNotProcFrComp | read-only | mandatory | Number of frames not processed in compression. |
| 1.3.6.1.4.1.2007.4.1.2.2.2.9.4.1.1.9 | ColumntelProdNpMonInterfFRCStatNotProcByComp | read-only | mandatory | Number of bytes not processed in compression. |
| 1.3.6.1.4.1.2007.4.1.2.2.2.9.4.1.1.10 | ColumntelProdNpMonInterfFRCStatErrorFrComp | read-only | mandatory | Number of frames with errors in compression. |
| 1.3.6.1.4.1.2007.4.1.2.2.2.9.4.1.1.11 | ColumntelProdNpMonInterfFRCStatOutSeqFrComp | read-only | mandatory | Number of frames out of sequence in compression. |
| 1.3.6.1.4.1.2007.4.1.2.2.2.9.4.1.1.12 | ColumntelProdNpMonInterfFRCStatManFrDecomp | read-only | mandatory | Number of frames managed in decompression. |
| 1.3.6.1.4.1.2007.4.1.2.2.2.9.4.1.1.13 | ColumntelProdNpMonInterfFRCStatManByDecomp | read-only | mandatory | Number of bytes managed in decompression. |
| 1.3.6.1.4.1.2007.4.1.2.2.2.9.4.1.1.14 | ColumntelProdNpMonInterfFRCStatProcFrDecomp | read-only | mandatory | Number of frames processed in decompression. |
| 1.3.6.1.4.1.2007.4.1.2.2.2.9.4.1.1.15 | ColumntelProdNpMonInterfFRCStatProcByDecomp | read-only | mandatory | Number of bytes processed in decompression. |
| 1.3.6.1.4.1.2007.4.1.2.2.2.9.4.1.1.16 | ColumntelProdNpMonInterfFRCStatNotProcFrDecomp | read-only | mandatory | Number of frames not processed in decompression. |
| 1.3.6.1.4.1.2007.4.1.2.2.2.9.4.1.1.17 | ColumntelProdNpMonInterfFRCStatNotProcByDecomp | read-only | mandatory | Number of bytes not processed in decompression. |
| 1.3.6.1.4.1.2007.4.1.2.2.2.9.4.1.1.18 | ColumntelProdNpMonInterfFRCStatErrorFrDecomp | read-only | mandatory | Number of frames with errors in decompression. |
| 1.3.6.1.4.1.2007.4.1.2.2.2.9.4.1.1.19 | ColumntelProdNpMonInterfFRCStatOutSeqFrDecomp | read-only | mandatory | Number of frames out of sequence in decompression. |
| 1.3.6.1.4.1.2007.4.1.2.2.2.9.4.2 | TabletelProdNpMonInterfFRCStatBeginTable | not-accessible | mandatory | This table contains compression statistics of Frame Relay, FR-Dial and FR over ISDN interfaces. The entry number is determined by the interface value (table in… |
| 1.3.6.1.4.1.2007.4.1.2.2.2.9.4.2.1 | RowtelProdNpMonInterfFRCStatBeginEntry | not-accessible | mandatory | Each entry consists of the node interface number, that is the table index, and a variable for each component of the time and date when the statistic counting b… |
| 1.3.6.1.4.1.2007.4.1.2.2.2.9.4.2.1.1 | ColumntelProdNpMonInterfFRCStatBeginInterfIndex | read-only | mandatory | Node interface number, that indicates the table entry (table index). |
| 1.3.6.1.4.1.2007.4.1.2.2.2.9.4.2.1.2 | ColumntelProdNpMonInterfFRCStatBeginDay | read-only | mandatory | Beginning day of the counting of compression statistics. |
| 1.3.6.1.4.1.2007.4.1.2.2.2.9.4.2.1.3 | ColumntelProdNpMonInterfFRCStatBeginMonth | read-only | mandatory | Beginning month of the counting of compression statistics. |
| 1.3.6.1.4.1.2007.4.1.2.2.2.9.4.2.1.4 | ColumntelProdNpMonInterfFRCStatBeginYear | read-only | mandatory | Beginning year of the counting of compression statistics. |
| 1.3.6.1.4.1.2007.4.1.2.2.2.9.4.2.1.5 | ColumntelProdNpMonInterfFRCStatBeginHour | read-only | mandatory | Beginning hour of the counting of compression statistics. |
| 1.3.6.1.4.1.2007.4.1.2.2.2.9.4.2.1.6 | ColumntelProdNpMonInterfFRCStatBeginMin | read-only | mandatory | Beginning minute of the counting of compression statistics. |
| 1.3.6.1.4.1.2007.4.1.2.2.2.9.4.2.1.7 | ColumntelProdNpMonInterfFRCStatBeginSec | read-only | mandatory | Beginning second of the counting of compression statistics. |
| 1.3.6.1.4.1.2007.4.1.2.2.2.9.4.3 | NodetelProdNpMonInterfFRCompVersGroup | |||
| 1.3.6.1.4.1.2007.4.1.2.2.2.9.4.3.1 | ScalartelProdNpMonInterfFRCompVersRevision | read-only | mandatory | Revision. |
| 1.3.6.1.4.1.2007.4.1.2.2.2.9.4.3.2 | ScalartelProdNpMonInterfFRCompVersCard | read-only | mandatory | Card. |
| 1.3.6.1.4.1.2007.4.1.2.2.2.9.4.3.3 | ScalartelProdNpMonInterfFRCompVersInterruptMode | read-only | mandatory | It indicates if the Interruption Mode is active (1) or inactive (2). |
| 1.3.6.1.4.1.2007.4.1.2.2.2.9.5 | TabletelProdNpMonInterfFRCrtpTable | not-accessible | mandatory | Table of statistics of CRTP compression of Frame Relay, FR-Dial and FR over RDSI interfaces. The entry number is determined by the interface value (first table… |
| 1.3.6.1.4.1.2007.4.1.2.2.2.9.5.1 | RowtelProdNpMonInterfFRCrtpEntry | not-accessible | mandatory | Each entry consists of the node interface number, which is the table index, the dlci number for the interface of which we want to obtain the statistics (second… |
| 1.3.6.1.4.1.2007.4.1.2.2.2.9.5.1.1 | ColumntelProdNpMonInterfFRCrtpIfcIndex | read-only | mandatory | Node interface number. It is the first table index. |
| 1.3.6.1.4.1.2007.4.1.2.2.2.9.5.1.2 | ColumntelProdNpMonInterfFRCrtpDlciIndex | read-only | mandatory | Dlci number of the interface. It is the second table index. |
| 1.3.6.1.4.1.2007.4.1.2.2.2.9.5.1.3 | ColumntelProdNpMonInterfFRCrtpClear | read-write | mandatory | This variable when is read shows the output from the last table delete attempt: the value is 2 if the deletion was performed succesfully, 3 if an error ocurred… |
| 1.3.6.1.4.1.2007.4.1.2.2.2.9.5.1.4 | ColumntelProdNpMonInterfFRCrtpOutRTPPack | read-only | mandatory | Number of detected outgoing RTP packets. |
| 1.3.6.1.4.1.2007.4.1.2.2.2.9.5.1.5 | ColumntelProdNpMonInterfFRCrtpOutRTPComp | read-only | mandatory | Number of compressed outgoing RTP packets |
| 1.3.6.1.4.1.2007.4.1.2.2.2.9.5.1.6 | ColumntelProdNpMonInterfFRCrtpSearchConn | read-only | mandatory | Number of searchs of the connection status. |
| 1.3.6.1.4.1.2007.4.1.2.2.2.9.5.1.7 | ColumntelProdNpMonInterfFRCrtpNoFindConn | read-only | mandatory | Number of times the connection status was not found. |
| 1.3.6.1.4.1.2007.4.1.2.2.2.9.5.1.8 | ColumntelProdNpMonInterfFRCrtpInRTPunCom | read-only | mandatory | Number of non compressed incoming RTP packets. |
| 1.3.6.1.4.1.2007.4.1.2.2.2.9.5.1.9 | ColumntelProdNpMonInterfFRCrtpInRTPComp | read-only | mandatory | Number of compressed incoming RTP packets. |
| 1.3.6.1.4.1.2007.4.1.2.2.2.9.5.1.10 | ColumntelProdNpMonInterfFRCrtpInUnknownType | read-only | mandatory | Number of unknown incoming RTP packets. |
| 1.3.6.1.4.1.2007.4.1.2.2.2.9.5.1.11 | ColumntelProdNpMonInterfFRCrtpContexStatePack | read-only | mandatory | Number of Context State RTP packets. |
| 1.3.6.1.4.1.2007.4.1.2.2.2.9.6 | TabletelProdNpMonInterfFRLmiTable | not-accessible | mandatory | LMI table. The entry number is determined by the interface value. |
| 1.3.6.1.4.1.2007.4.1.2.2.2.9.6.1 | RowtelProdNpMonInterfFRLmiEntry | not-accessible | mandatory | Each entry consists of the node interface number, that is the table index, a variable that shows the output from the last statistics delete attempt, another va… |
| 1.3.6.1.4.1.2007.4.1.2.2.2.9.6.1.1 | ColumntelProdNpMonInterfFRLmiIndex | read-only | mandatory | Node interface number, that shows the corresponding table entry (table index). |
| 1.3.6.1.4.1.2007.4.1.2.2.2.9.6.1.2 | ColumntelProdNpMonInterfFRLmiClearStat | read-write | mandatory | This variable when is read shows the output from the last table delete attempt: the value is 2 if the deletion was performed succesfully, 3 if an error ocurred… |
| 1.3.6.1.4.1.2007.4.1.2.2.2.9.6.1.3 | ColumntelProdNpMonInterfFRLmiHab | read-only | mandatory | LMI enabled or disabled: it shows if Frame Relay management is active (1) or inactive (2). |
| 1.3.6.1.4.1.2007.4.1.2.2.2.9.6.1.4 | ColumntelProdNpMonInterfFRLmiDlci | read-only | mandatory | LMI DLCI: Management circuit number. It will be 0(ANSI, CCITT) or 1023(LMI). |
| 1.3.6.1.4.1.2007.4.1.2.2.2.9.6.1.5 | ColumntelProdNpMonInterfFRLmiType | read-only | mandatory | LMI Type: (1) CCITT, (2) ANSI T.1 617 Annex D, (3) LMI Rev.1. If LMI is not enabled this variable takes the value 0 (disabled-lmi). |
| 1.3.6.1.4.1.2007.4.1.2.2.2.9.6.1.6 | ColumntelProdNpMonInterfFRLmiOrphans | read-only | mandatory | Indicates if all non configured circuits made known by management are available for use, yes or no. |
| 1.3.6.1.4.1.2007.4.1.2.2.2.9.6.1.7 | ColumntelProdNpMonInterfFRLmiSecInterv | read-only | mandatory | Indicates the sequence interval that LMI management uses (in seconds). |
| 1.3.6.1.4.1.2007.4.1.2.2.2.9.6.1.8 | ColumntelProdNpMonInterfFRLmiLineAccRate | read-only | mandatory | Physical data rate of the Frame Relay interface in bits per second. |
| 1.3.6.1.4.1.2007.4.1.2.2.2.9.6.1.9 | ColumntelProdNpMonInterfFRLmiMTU | read-only | mandatory | MTU (maximum transmission unit) of the Frame Relay interface in bytes. |
| 1.3.6.1.4.1.2007.4.1.2.2.2.9.6.1.10 | ColumntelProdNpMonInterfFRLmiCIRAdjust | read-only | mandatory | CIR monitor adjustment. |
| 1.3.6.1.4.1.2007.4.1.2.2.2.9.6.1.11 | ColumntelProdNpMonInterfFRLmiT1 | read-only | mandatory | Timer T1, in seconds. |
| 1.3.6.1.4.1.2007.4.1.2.2.2.9.6.1.12 | ColumntelProdNpMonInterfFRLmiN1 | read-only | mandatory | Counter N1 increments. |
| 1.3.6.1.4.1.2007.4.1.2.2.2.9.6.1.13 | ColumntelProdNpMonInterfFRLmiN2 | read-only | mandatory | Allowable errors N2. |
| 1.3.6.1.4.1.2007.4.1.2.2.2.9.6.1.14 | ColumntelProdNpMonInterfFRLmiN3 | read-only | mandatory | Error window N3. |
| 1.3.6.1.4.1.2007.4.1.2.2.2.9.6.1.15 | ColumntelProdNpMonInterfFRLmiIRIncr | read-write | mandatory | IR adjustment percentage increment. |
| 1.3.6.1.4.1.2007.4.1.2.2.2.9.6.1.16 | ColumntelProdNpMonInterfFRLmiIRDecr | read-write | mandatory | IR adjustment percentage decrement. |
| 1.3.6.1.4.1.2007.4.1.2.2.2.9.6.1.17 | ColumntelProdNpMonInterfFRLmiIRMin | read-write | mandatory | Minimum IR as CIR percentage. |
| 1.3.6.1.4.1.2007.4.1.2.2.2.9.6.1.18 | ColumntelProdNpMonInterfFRLmiPTPLine | read-only | mandatory | Point to point line enabled (1) or not (2). |
| 1.3.6.1.4.1.2007.4.1.2.2.2.9.6.1.19 | ColumntelProdNpMonInterfFRLmiPTPDlci | read-only | mandatory | Point to point dlci: used when the net is configured as point to point. |
| 1.3.6.1.4.1.2007.4.1.2.2.2.9.6.1.20 | ColumntelProdNpMonInterfFRLmiProtBroad | read-only | mandatory | Broadcast Protocol : Yes (1) or No (2). |
| 1.3.6.1.4.1.2007.4.1.2.2.2.9.6.1.21 | ColumntelProdNpMonInterfFRLmiEmuMulticast | read-only | mandatory | Emulate Multicast: it shows if multicast emulation is enabled on each active PVC, yes (1) or no(2). |
| 1.3.6.1.4.1.2007.4.1.2.2.2.9.6.1.22 | ColumntelProdNpMonInterfFRLmiCongMonit | read-write | mandatory | Congestion Monitoring: congestion monitoring feature. The variable value may be (1) if it is enabled congestion monitoring or (2) if not. |
| 1.3.6.1.4.1.2007.4.1.2.2.2.9.6.1.23 | ColumntelProdNpMonInterfFRLmiCIRMonit | read-write | mandatory | FR CIR monitoring: indicates whether the circuit monitoring feature that enforces the transmission rate is enabled, yes (1) or no (2). |
| 1.3.6.1.4.1.2007.4.1.2.2.2.9.6.1.24 | ColumntelProdNpMonInterfFRLmiEnabPVCBkupRetTime | read-write | mandatory | Enable the prompt return from the PVC back-up. This variable only makes sense in a set operation (value 1). It can be enabled, but not disabled. In a read oper… |
| 1.3.6.1.4.1.2007.4.1.2.2.2.9.6.1.25 | ColumntelProdNpMonInterfFRLmiCurrentRcvSeq | read-only | mandatory | Sequence number received. |
| 1.3.6.1.4.1.2007.4.1.2.2.2.9.6.1.26 | ColumntelProdNpMonInterfFRLmiCurrentTxSeq | read-only | mandatory | Sequence number transmitted. |
| 1.3.6.1.4.1.2007.4.1.2.2.2.9.6.1.27 | ColumntelProdNpMonInterfFRLmiTotStatusEnq | read-only | mandatory | Total number of link status inquiries. |
| 1.3.6.1.4.1.2007.4.1.2.2.2.9.6.1.28 | ColumntelProdNpMonInterfFRLmiTotStatusResp | read-only | mandatory | Total number of link status responses. |
| 1.3.6.1.4.1.2007.4.1.2.2.2.9.6.1.29 | ColumntelProdNpMonInterfFRLmiTotSeqReq | read-only | mandatory | Total number of sequence requests. |
| 1.3.6.1.4.1.2007.4.1.2.2.2.9.6.1.30 | ColumntelProdNpMonInterfFRLmiTotSeqResp | read-only | mandatory | Total number of sequence responses. |
| 1.3.6.1.4.1.2007.4.1.2.2.2.9.7 | TabletelProdNpMonInterfFRPvcStatusTable | not-accessible | mandatory | Table of PVC Status. The entry is determined by the interface number. It gives information about the number of allowable PVCs, configured PVCs, active PVCs, co… |
| 1.3.6.1.4.1.2007.4.1.2.2.2.9.7.1 | RowtelProdNpMonInterfFRPvcStatusEntry | not-accessible | mandatory | Each entry consists of the number of the node interface that is the table index, a variable to delete the table (in get operations shows the output from the la… |
| 1.3.6.1.4.1.2007.4.1.2.2.2.9.7.1.1 | ColumntelProdNpMonInterfFRPvcStaIfcIndex | read-only | mandatory | Number of the node interface, that indicates the corresponding table entry (it is the table index). |
| 1.3.6.1.4.1.2007.4.1.2.2.2.9.7.1.2 | ColumntelProdNpMonInterfFRPvcStaClear | read-write | mandatory | This variable when is read shows the output from the last table delete attempt: the value is 2 if the deletion was performed succesfully, 3 if an error ocurred… |
| 1.3.6.1.4.1.2007.4.1.2.2.2.9.7.1.3 | ColumntelProdNpMonInterfFRPvcStaTotAllow | read-only | mandatory | Number of allowable PVCs. |
| 1.3.6.1.4.1.2007.4.1.2.2.2.9.7.1.4 | ColumntelProdNpMonInterfFRPvcStaTotConfig | read-only | mandatory | Total number of currently configured PVCs. |
| 1.3.6.1.4.1.2007.4.1.2.2.2.9.7.1.5 | ColumntelProdNpMonInterfFRPvcStaTotActiv | read-only | mandatory | Total number of active PVCs. |
| 1.3.6.1.4.1.2007.4.1.2.2.2.9.7.1.6 | ColumntelProdNpMonInterfFRPvcStaTotCong | read-only | mandatory | Total number of congested PVCs. |
| 1.3.6.1.4.1.2007.4.1.2.2.2.9.7.1.7 | ColumntelProdNpMonInterfFRPvcStaTotLeftNet | read-only | mandatory | Total number of left PVCs (left net). |
| 1.3.6.1.4.1.2007.4.1.2.2.2.9.7.1.8 | ColumntelProdNpMonInterfFRPvcStaTotJoinNet | read-only | mandatory | Total number of joined PVCs (join net). |
| 1.3.6.1.4.1.2007.4.1.2.2.2.9.8 | TabletelProdNpMonInterfFRPvcTable | not-accessible | mandatory | Table of PVCs. The entry is determined by the interface number and the circuit number (dlci), that are the table index. It contains information about the circu… |
| 1.3.6.1.4.1.2007.4.1.2.2.2.9.8.1 | RowtelProdNpMonInterfFRPvcEntry | not-accessible | mandatory | Each entry contains the number of node interface (first table index), the circuit number (dlci) (second index), a variable to delete the table (in get operatio… |
| 1.3.6.1.4.1.2007.4.1.2.2.2.9.8.1.1 | ColumntelProdNpMonInterfFRPvcIfcIndex | read-only | mandatory | Number of the node interface (it is the first table index). |
| 1.3.6.1.4.1.2007.4.1.2.2.2.9.8.1.2 | ColumntelProdNpMonInterfFRPvcDlciIndex | read-only | mandatory | Circuit number (dlci) for that interface (second table index). |
| 1.3.6.1.4.1.2007.4.1.2.2.2.9.8.1.3 | ColumntelProdNpMonInterfFRPvcClearStatistics | read-write | mandatory | This variable when is read shows the output from the last table delete attempt: the value is 2 if the deletion was performed succesfully, 3 if an error ocurred… |
| 1.3.6.1.4.1.2007.4.1.2.2.2.9.8.1.4 | ColumntelProdNpMonInterfFRPvcName | read-only | mandatory | Circuit name. |
| 1.3.6.1.4.1.2007.4.1.2.2.2.9.8.1.5 | ColumntelProdNpMonInterfFRPvcCircStatus | read-write | mandatory | Circuit state: (1) inactive (waiting in LMI), (2) active, (3) congested, (4) removed. If this field stores a value different from the previous ones (active, co… |
| 1.3.6.1.4.1.2007.4.1.2.2.2.9.8.1.6 | ColumntelProdNpMonInterfFRPvcCircType | read-only | mandatory | Type of circuit: (0) unknown, (1) permanent, (2) switched, (3) multicast. |
| 1.3.6.1.4.1.2007.4.1.2.2.2.9.8.1.7 | ColumntelProdNpMonInterfFRPvcOrphan | read-only | mandatory | This variable indicates if the circuit is orphan, yes (1) or no (2). |
| 1.3.6.1.4.1.2007.4.1.2.2.2.9.8.1.8 | ColumntelProdNpMonInterfFRPvcEncrypt | read-only | mandatory | This variable indicates if data are encoded, yes (1) or no (2). |
| 1.3.6.1.4.1.2007.4.1.2.2.2.9.8.1.9 | ColumntelProdNpMonInterfFRPvcTxFrames | read-only | mandatory | Transmitted frames. |
| 1.3.6.1.4.1.2007.4.1.2.2.2.9.8.1.10 | ColumntelProdNpMonInterfFRPvcTxBytes | read-only | mandatory | Transmitted bytes. |
| 1.3.6.1.4.1.2007.4.1.2.2.2.9.8.1.11 | ColumntelProdNpMonInterfFRPvcRcvFrames | read-only | mandatory | Received frames. |
| 1.3.6.1.4.1.2007.4.1.2.2.2.9.8.1.12 | ColumntelProdNpMonInterfFRPvcRcvBytes | read-only | mandatory | Received bytes. |
| 1.3.6.1.4.1.2007.4.1.2.2.2.9.8.1.13 | ColumntelProdNpMonInterfFRPvcQueueOverf | read-only | mandatory | Transmitted frames lost due to queue overflow. |
| 1.3.6.1.4.1.2007.4.1.2.2.2.9.8.1.14 | ColumntelProdNpMonInterfFRPvcOverrun | read-only | mandatory | Frames lost due to input overrun. This variable only makes sense if the interface is not FR over ISDN or FR-DIAL, or FR over ISDN is not enabled. In the previo… |
| 1.3.6.1.4.1.2007.4.1.2.2.2.9.8.1.15 | ColumntelProdNpMonInterfFRPvcTotFECNs | read-only | mandatory | Total FECNs: number of times inbound congestion was notified. |
| 1.3.6.1.4.1.2007.4.1.2.2.2.9.8.1.16 | ColumntelProdNpMonInterfFRPvcTotBECNs | read-only | mandatory | Total BECNs: number of times outbound congestion was notified. |
| 1.3.6.1.4.1.2007.4.1.2.2.2.9.8.1.17 | ColumntelProdNpMonInterfFRPvcTimesCong | read-only | mandatory | Number of times the circuit became congested. |
| 1.3.6.1.4.1.2007.4.1.2.2.2.9.8.1.18 | ColumntelProdNpMonInterfFRPvcTimesInact | read-only | mandatory | Number of times this circuit was inoperable. |
| 1.3.6.1.4.1.2007.4.1.2.2.2.9.8.1.19 | ColumntelProdNpMonInterfFRPvcCIR | read-write | mandatory | CIR (Committed Information Rate), en bps. |
| 1.3.6.1.4.1.2007.4.1.2.2.2.9.8.1.20 | ColumntelProdNpMonInterfFRPvcVIR | read-only | mandatory | VIR (Current Information Rate). |
| 1.3.6.1.4.1.2007.4.1.2.2.2.9.8.1.21 | ColumntelProdNpMonInterfFRPvcBc | read-write | mandatory | Bc (Commited Burst Size), en bits. |
| 1.3.6.1.4.1.2007.4.1.2.2.2.9.8.1.22 | ColumntelProdNpMonInterfFRPvcBe | read-write | mandatory | Be (Excess Burst Size). |
| 1.3.6.1.4.1.2007.4.1.2.2.2.9.9 | TabletelProdNpMonInterfFRProtAddTable | not-accessible | mandatory | Table of protocol addresses. It contains information about the protocol type, the protocol address (it is possible to have several per protocol and interface) … |
| 1.3.6.1.4.1.2007.4.1.2.2.2.9.9.1 | RowtelProdNpMonInterfFRProtAddEntry | not-accessible | mandatory | Each entry consists of the number of the interface (first table index), the protocol type (second index), the address order number (third index: it is necessar… |
| 1.3.6.1.4.1.2007.4.1.2.2.2.9.9.1.1 | ColumntelProdNpMonInterfFRProtAddIfcIndex | read-only | mandatory | Number of the interface (first table index). |
| 1.3.6.1.4.1.2007.4.1.2.2.2.9.9.1.2 | ColumntelProdNpMonInterfFRProtAddProtocIndex | read-only | mandatory | Protocol type (second table index). |
| 1.3.6.1.4.1.2007.4.1.2.2.2.9.9.1.3 | ColumntelProdNpMonInterfFRProtAddOrdenIndex | read-only | mandatory | Address order number (it is possible to have several addresses associated to each protocol and interface). It is the third index. |
| 1.3.6.1.4.1.2007.4.1.2.2.2.9.9.1.4 | ColumntelProdNpMonInterfFRProtAddAddress | read-only | mandatory | Protocol address. |
| 1.3.6.1.4.1.2007.4.1.2.2.2.9.9.1.5 | ColumntelProdNpMonInterfFRProtAddDlci | read-only | mandatory | Dlci associated to that address. |
| 1.3.6.1.4.1.2007.4.1.2.2.2.9.10 | TabletelProdNpMonInterfFRActCallsTable | not-accessible | mandatory | Table of active calls. It contains information about the name and number (dlci) of the circuit through which the call is established, called and calling number… |
| 1.3.6.1.4.1.2007.4.1.2.2.2.9.10.1 | RowtelProdNpMonInterfFRActCallsEntry | not-accessible | mandatory | Each entry contains the number of the node interface (first index), the order number of the call in the table (second index), name and dlci of the circuit thro… |
| 1.3.6.1.4.1.2007.4.1.2.2.2.9.10.1.1 | ColumntelProdNpMonInterfFRActCallsIfcIndex | read-only | obsolete | Number of the interface (first table index). |
| 1.3.6.1.4.1.2007.4.1.2.2.2.9.10.1.2 | ColumntelProdNpMonInterfFRActCallsOrdenIndex | read-only | obsolete | Call order or position in the table (second index). |
| 1.3.6.1.4.1.2007.4.1.2.2.2.9.10.1.3 | ColumntelProdNpMonInterfFRActCallsCircuitName | read-only | obsolete | Circuit name. |
| 1.3.6.1.4.1.2007.4.1.2.2.2.9.10.1.4 | ColumntelProdNpMonInterfFRActCallsDlci | read-only | obsolete | Dlci Number of the circuit through which the call is established. |
| 1.3.6.1.4.1.2007.4.1.2.2.2.9.10.1.5 | ColumntelProdNpMonInterfFRActCallsCalledNum | read-only | obsolete | Called number |
| 1.3.6.1.4.1.2007.4.1.2.2.2.9.10.1.6 | ColumntelProdNpMonInterfFRActCallsCallingNum | read-only | obsolete | Calling number. |
| 1.3.6.1.4.1.2007.4.1.2.2.2.9.10.1.7 | ColumntelProdNpMonInterfFRActCallsRef | read-only | obsolete | Call reference. |
| 1.3.6.1.4.1.2007.4.1.2.2.2.9.10.1.8 | ColumntelProdNpMonInterfFRActCallsStartHour | read-only | obsolete | Indicates the hour the call was initialized. |
| 1.3.6.1.4.1.2007.4.1.2.2.2.9.10.1.9 | ColumntelProdNpMonInterfFRActCallsStartMin | read-only | obsolete | Indicates the minute the call was initialized. |
| 1.3.6.1.4.1.2007.4.1.2.2.2.9.10.1.10 | ColumntelProdNpMonInterfFRActCallsStartSec | read-only | obsolete | Indicates the second the call was initialized. |
| 1.3.6.1.4.1.2007.4.1.2.2.2.9.11 | TabletelProdNpMonInterfFRRelCallsTable | not-accessible | mandatory | Table of released calls. Contains information about the name and dlci of the circuit through which the call was initialized, called and calling numbers, cause … |
| 1.3.6.1.4.1.2007.4.1.2.2.2.9.11.1 | RowtelProdNpMonInterfFRRelCallsEntry | not-accessible | mandatory | Each entry contains the number of the node interface (first index), the order number of the call in the table (second index), name and dlci of the circuit thro… |
| 1.3.6.1.4.1.2007.4.1.2.2.2.9.11.1.1 | ColumntelProdNpMonInterfFRRelCallsIndex | read-only | obsolete | Number of interface (first table index). |
| 1.3.6.1.4.1.2007.4.1.2.2.2.9.11.1.2 | ColumntelProdNpMonInterfFRRelCallsOrdenIndex | read-only | obsolete | Call order or position in the table (second index). |
| 1.3.6.1.4.1.2007.4.1.2.2.2.9.11.1.3 | ColumntelProdNpMonInterfFRRelCallsClear | read-write | obsolete | This variable when is read shows the output from the last table delete attempt: the value is 2 if the deletion was performed succesfully, 3 if an error ocurred… |
| 1.3.6.1.4.1.2007.4.1.2.2.2.9.11.1.4 | ColumntelProdNpMonInterfFRRelCallsCircName | read-only | obsolete | Name of the circuit through which the call was established. |
| 1.3.6.1.4.1.2007.4.1.2.2.2.9.11.1.5 | ColumntelProdNpMonInterfFRRelCallsDlci | read-only | obsolete | Dlci number of the circuit through which the call was established. |
| 1.3.6.1.4.1.2007.4.1.2.2.2.9.11.1.6 | ColumntelProdNpMonInterfFRRelCallsCalledNum | read-only | obsolete | Called number. |
| 1.3.6.1.4.1.2007.4.1.2.2.2.9.11.1.7 | ColumntelProdNpMonInterfFRRelCallsCallingNum | read-only | obsolete | Calling number. |
| 1.3.6.1.4.1.2007.4.1.2.2.2.9.11.1.8 | ColumntelProdNpMonInterfFRRelCallsCL | read-only | obsolete | This indicates why the call has been released. |
| 1.3.6.1.4.1.2007.4.1.2.2.2.9.11.1.9 | ColumntelProdNpMonInterfFRRelCallsDL | read-only | obsolete | Indicates the released call diagnosis. |
| 1.3.6.1.4.1.2007.4.1.2.2.2.9.11.1.10 | ColumntelProdNpMonInterfFRRelCallsStartHour | read-only | obsolete | Indicates the hour the call was initialized. |
| 1.3.6.1.4.1.2007.4.1.2.2.2.9.11.1.11 | ColumntelProdNpMonInterfFRRelCallsStartMin | read-only | obsolete | Indicates the minute the call was initialized. |
| 1.3.6.1.4.1.2007.4.1.2.2.2.9.11.1.12 | ColumntelProdNpMonInterfFRRelCallsStartSec | read-only | obsolete | Indicates the second the call was initialized. |
| 1.3.6.1.4.1.2007.4.1.2.2.2.9.11.1.13 | ColumntelProdNpMonInterfFRRelCallsEndHour | read-only | obsolete | Indicates the hour the call was released. |
| 1.3.6.1.4.1.2007.4.1.2.2.2.9.11.1.14 | ColumntelProdNpMonInterfFRRelCallsEndMin | read-only | obsolete | Indicates the minute the call was released. |
| 1.3.6.1.4.1.2007.4.1.2.2.2.9.11.1.15 | ColumntelProdNpMonInterfFRRelCallsEndSec | read-only | obsolete | Indicates the second the call was released. |