OIDNameAccessStatusDescription
1.3.6.1.4.1.2007.4.1.2.2.2.15NodetelProdNpMonInterfSSL
1.3.6.1.4.1.2007.4.1.2.2.2.15.1TabletelProdNpMonIfcSSLGlobalTablenot-accessiblemandatoryThis table contains general information about synchronous serial line interfaces. The interface number determines the entry number.
1.3.6.1.4.1.2007.4.1.2.2.2.15.1.1RowtelProdNpMonIfcSSLGlobalEntrynot-accessiblemandatoryEach table entry contains the interface number of the related node, which is the index used to go over the table, the type of physical driver (DTE or DCE), the…
1.3.6.1.4.1.2007.4.1.2.2.2.15.1.1.1ColumntelProdNpMonIfcSSLGloIndexread-onlymandatoryThe node interface number, which indicates the corresponding table entry (it is the table index).
1.3.6.1.4.1.2007.4.1.2.2.2.15.1.1.2ColumntelProdNpMonIfcSSLGloDriverTyperead-onlymandatoryType of physical driver: (1) DCE, (2) DTE. This variable is a string that indicates the driver.
1.3.6.1.4.1.2007.4.1.2.2.2.15.1.1.3ColumntelProdNpMonIfcSSLGloLineSpeedread-onlymandatoryLine speed, in bits per second. The value 0 indicates speed unknown.
1.3.6.1.4.1.2007.4.1.2.2.2.15.1.1.4ColumntelProdNpMonIfcSSLGloLastResetWeekread-onlymandatoryWeeks passed since the last reset of the port.
1.3.6.1.4.1.2007.4.1.2.2.2.15.1.1.5ColumntelProdNpMonIfcSSLGloLastResetDayread-onlymandatoryDays passed since the last reset of the port: the remaining days that we get after counting the number of weeks that are not enough to form a week, this implie…
1.3.6.1.4.1.2007.4.1.2.2.2.15.1.1.6ColumntelProdNpMonIfcSSLGloLastResetHourread-onlymandatoryHours passed since the last reset of the port. If it has passed more than a week, this variable indicates the number of hours to be added to the number of week…
1.3.6.1.4.1.2007.4.1.2.2.2.15.1.1.7ColumntelProdNpMonIfcSSLGloLastResetMinread-onlymandatoryMinutes passed since the last reset of the port. This variable indicates the number of minutes since the last hour added to the hour counter.
1.3.6.1.4.1.2007.4.1.2.2.2.15.1.1.8ColumntelProdNpMonIfcSSLGloLastResetSecread-onlymandatorySeconds passed since the last reset of the port. The total time passed will be calculated by adding weeks, days, hours, minutes and seconds since the last rese…
1.3.6.1.4.1.2007.4.1.2.2.2.15.1.1.9ColumntelProdNpMonIfcSSLGloLoopbackread-onlymandatoryThis variable indicates if SCC loopback mode is active: transmitter is connected internally to the receiver.
1.3.6.1.4.1.2007.4.1.2.2.2.15.1.1.10ColumntelProdNpMonIfcSSLGloEchoread-onlymandatoryThis variable indicates if SCC echo mode is active: transmitter resends received data.
1.3.6.1.4.1.2007.4.1.2.2.2.15.1.1.11ColumntelProdNpMonIfcSSLGloDTEIntClocksread-onlymandatoryThis variable indicates if DTE driver uses internal clocks.
1.3.6.1.4.1.2007.4.1.2.2.2.15.1.1.12ColumntelProdNpMonIfcSSLGloIgnoreCDread-onlymandatoryThis variable indicates if CD signal state is ignored.
1.3.6.1.4.1.2007.4.1.2.2.2.15.1.1.13ColumntelProdNpMonIfcSSLGloDisconnectCDread-onlymandatoryThis variable indicates if CD signal is disconnected from internal hardware.
1.3.6.1.4.1.2007.4.1.2.2.2.15.1.1.14ColumntelProdNpMonIfcSSLGloIgnoreCTSread-onlymandatoryThis variable indicates if CTS signal state is ignored.
1.3.6.1.4.1.2007.4.1.2.2.2.15.1.1.15ColumntelProdNpMonIfcSSLGloIgnoreDSRread-onlymandatoryThis variable indicates if DSR signal state is ignored.
1.3.6.1.4.1.2007.4.1.2.2.2.15.2TabletelProdNpMonIfcSSLRS232Tablenot-accessiblemandatoryThis table contains the signals or circuits RS232. It shows wether the signals are active or not. The entry number is determined by the interface number consid…
1.3.6.1.4.1.2007.4.1.2.2.2.15.2.1RowtelProdNpMonIfcSSLRS232Entrynot-accessiblemandatoryEach entry contains the interface number of the node considered, which will be the first index used to go over the table, the order number of the circuit insid…
1.3.6.1.4.1.2007.4.1.2.2.2.15.2.1.1ColumntelProdNpMonIfcSSLRS232IfcIndexread-onlymandatorySynchronous serial line interface number of the node. It is the first table index.
1.3.6.1.4.1.2007.4.1.2.2.2.15.2.1.2ColumntelProdNpMonIfcSSLRS232CircIndexread-onlymandatorySecond table index. This number goes from 1 to the number of circuits of this type allowed, which varies with the conector type.
1.3.6.1.4.1.2007.4.1.2.2.2.15.2.1.3ColumntelProdNpMonIfcSSLRS232Circuitread-onlymandatoryRS232 circuit number. Values accepted are 105, 106, 107, 108, 109, 125 y 141.
1.3.6.1.4.1.2007.4.1.2.2.2.15.2.1.4ColumntelProdNpMonIfcSSLRS232Nicknameread-onlymandatoryCircuit name.
1.3.6.1.4.1.2007.4.1.2.2.2.15.2.1.5ColumntelProdNpMonIfcSSLRS232Stateread-onlymandatoryState of (circuit) signals: on, off or unknown.
1.3.6.1.4.1.2007.4.1.2.2.2.15.3TabletelProdNpMonIfcSSLFramesTablenot-accessiblemandatoryThis table contains a counter of outgoing frames and a counter of bugs in ingoing frames. The entry number is determined by the interface number (table index).
1.3.6.1.4.1.2007.4.1.2.2.2.15.3.1RowtelProdNpMonIfcSSLFramesEntrynot-accessiblemandatoryEach entry contains the node interface number, which is the index used to go over the table, a variable that shows the last output obtained when the user tried…
1.3.6.1.4.1.2007.4.1.2.2.2.15.3.1.1ColumntelProdNpMonIfcSSLFramesIndexread-onlymandatoryInterface number of the node, that shows the corresponding table entry (it is the index).
1.3.6.1.4.1.2007.4.1.2.2.2.15.3.1.2ColumntelProdNpMonIfcSSLFramesClearread-writemandatoryThis variable when is read shows the output from the last table delete attempt: the value is 2 if the deletion was performed succesfully, 3 if an error ocurred…
1.3.6.1.4.1.2007.4.1.2.2.2.15.3.1.3ColumntelProdNpMonIfcSSLFramesCRCErrorread-onlymandatoryNumber of frames with CRC errors.
1.3.6.1.4.1.2007.4.1.2.2.2.15.3.1.4ColumntelProdNpMonIfcSSLFramesAlignmentread-onlymandatoryNumber of incoming frames with alignment errors.
1.3.6.1.4.1.2007.4.1.2.2.2.15.3.1.5ColumntelProdNpMonIfcSSLFramesMissedread-onlymandatoryNumber of incoming frames lost due to overrun.
1.3.6.1.4.1.2007.4.1.2.2.2.15.3.1.6ColumntelProdNpMonIfcSSLFramesTooLongread-onlymandatoryNumber of incoming frames too long.
1.3.6.1.4.1.2007.4.1.2.2.2.15.3.1.7ColumntelProdNpMonIfcSSLFramesAbortedread-onlymandatoryNumber of incoming frames aborted.
1.3.6.1.4.1.2007.4.1.2.2.2.15.3.1.8ColumntelProdNpMonIfcSSLFramesOverrunread-onlymandatoryNumber of DMA/FIFO overrun.
1.3.6.1.4.1.2007.4.1.2.2.2.15.3.1.9ColumntelProdNpMonIfcSSLFramesUnderrunread-onlymandatoryNumber of DMA/FIFO underrun.