TELDAT-TRAP-FRBK-MIB

36 objects
This Module Information Base file is defined for managing received SNMP notifications generated by the FRBK event subsystem.
Imported Objects
SNMPv2-SMIInteger32 IpAddress MODULE-IDENTITY NOTIFICATION-TYPE OBJECT-IDENTITY OBJECT-TYPE
SNMPv2-TCDisplayString
TELDAT-MIBtelEventTraps
OIDNameAccessStatusDescription
1.3.6.1.4.1.2007.1.4.114IdentityfrbkTrapsMIBThis Module Information Base file is defined for managing received SNMP notifications generated by the FRBK event subsystem.
1.3.6.1.4.1.2007.1.4.114.1NodefrbkEventsGroup
1.3.6.1.4.1.2007.1.4.114.1.1IdentityfrbkEventObjects1currentEvent FRBK.1 A PVC switched to backup state.
1.3.6.1.4.1.2007.1.4.114.1.1.1Scalarfrbk1-circuitaccessible-for-notifycurrentParameter 'circuit' in event FRBK.1
1.3.6.1.4.1.2007.1.4.114.1.1.2Scalarfrbk1-ifc-nameaccessible-for-notifycurrentParameter 'ifc-name' in event FRBK.1
1.3.6.1.4.1.2007.1.4.114.1.2IdentityfrbkEventObjects2currentEvent FRBK.2 A PVC returns from backup state to active state.
1.3.6.1.4.1.2007.1.4.114.1.2.1Scalarfrbk2-circuitaccessible-for-notifycurrentParameter 'circuit' in event FRBK.2
1.3.6.1.4.1.2007.1.4.114.1.2.2Scalarfrbk2-ifc-nameaccessible-for-notifycurrentParameter 'ifc-name' in event FRBK.2
1.3.6.1.4.1.2007.1.4.114.1.3IdentityfrbkEventObjects3currentEvent FRBK.3 All PVCs in backup state are forced to return to active state whenever it is possible.
1.3.6.1.4.1.2007.1.4.114.1.3.1Scalarfrbk3-ifc-nameaccessible-for-notifycurrentParameter 'ifc-name' in event FRBK.3
1.3.6.1.4.1.2007.1.4.114.1.4IdentityfrbkEventObjects4currentEvent FRBK.4 When backup timer expires all circuits can switch to normal operation (if it is possible).
1.3.6.1.4.1.2007.1.4.114.1.4.1Scalarfrbk4-ifc-nameaccessible-for-notifycurrentParameter 'ifc-name' in event FRBK.4
1.3.6.1.4.1.2007.1.4.114.1.5IdentityfrbkEventObjects5currentEvent FRBK.5 All traffic which normally goes through Frame Relay interface must be routered through the associated backup interface over ISDN.
1.3.6.1.4.1.2007.1.4.114.1.5.1Scalarfrbk5-ifc-nameaccessible-for-notifycurrentParameter 'ifc-name' in event FRBK.5
1.3.6.1.4.1.2007.1.4.114.1.5.2Scalarfrbk5-isdn-ifc-nameaccessible-for-notifycurrentParameter 'isdn-ifc-name' in event FRBK.5
1.3.6.1.4.1.2007.1.4.114.1.6IdentityfrbkEventObjects6currentEvent FRBK.6 Frame Relay interface (primary link) has recovered: it is active and operative again, so the secondary link automatically disconnects and traffic …
1.3.6.1.4.1.2007.1.4.114.1.6.1Scalarfrbk6-ifc-nameaccessible-for-notifycurrentParameter 'ifc-name' in event FRBK.6
1.3.6.1.4.1.2007.1.4.114.1.6.2Scalarfrbk6-isdn-ifc-nameaccessible-for-notifycurrentParameter 'isdn-ifc-name' in event FRBK.6
1.3.6.1.4.1.2007.1.4.114.1.7IdentityfrbkEventObjects7currentEvent FRBK.7 A PVC switched to backup state.
1.3.6.1.4.1.2007.1.4.114.1.7.1Scalarfrbk7-circuitaccessible-for-notifycurrentParameter 'circuit' in event FRBK.7
1.3.6.1.4.1.2007.1.4.114.1.7.2Scalarfrbk7-ifc-nameaccessible-for-notifycurrentParameter 'ifc-name' in event FRBK.7
1.3.6.1.4.1.2007.1.4.114.1.7.3Scalarfrbk7-isdn-ifc-nameaccessible-for-notifycurrentParameter 'isdn-ifc-name' in event FRBK.7
1.3.6.1.4.1.2007.1.4.114.1.8IdentityfrbkEventObjects8currentEvent FRBK.8 A PVC returns from backup state to active state.
1.3.6.1.4.1.2007.1.4.114.1.8.1Scalarfrbk8-circuitaccessible-for-notifycurrentParameter 'circuit' in event FRBK.8
1.3.6.1.4.1.2007.1.4.114.1.8.2Scalarfrbk8-ifc-nameaccessible-for-notifycurrentParameter 'ifc-name' in event FRBK.8
1.3.6.1.4.1.2007.1.4.114.1.8.3Scalarfrbk8-isdn-ifc-nameaccessible-for-notifycurrentParameter 'isdn-ifc-name' in event FRBK.8
1.3.6.1.4.1.2007.1.4.114.2NodefrbkNotifications
1.3.6.1.4.1.2007.1.4.114.2.0NodefrbkNotificationsPrefix
1.3.6.1.4.1.2007.1.4.114.2.0.1NotificationfrbkNotification1currentNotification of Event FRBK.1 Message: 'Backup-PVC, PVC=$1 PVCBackup=$2, on interface $3' Parameters list: $1: frbk1-circuit $2: frbk1-circuit $3: frbk1-ifc-nam…
1.3.6.1.4.1.2007.1.4.114.2.0.2NotificationfrbkNotification2currentNotification of Event FRBK.2 Message: 'Return Backup-PVC, PVC=$1 PVCBackup= $2, on interface $3' Parameters list: $1: frbk2-circuit $2: frbk2-circuit $3: frbk2…
1.3.6.1.4.1.2007.1.4.114.2.0.3NotificationfrbkNotification3currentNotification of Event FRBK.3 Message: 'Return command Backup PVC, on interface $1' Parameters list: $1: frbk3-ifc-name All PVCs in backup state are forced to r…
1.3.6.1.4.1.2007.1.4.114.2.0.4NotificationfrbkNotification4currentNotification of Event FRBK.4 Message: 'Tiemout Backup PVC, on interface $1' Parameters list: $1: frbk4-ifc-name When backup timer expires all circuits can swit…
1.3.6.1.4.1.2007.1.4.114.2.0.5NotificationfrbkNotification5currentNotification of Event FRBK.5 Message: 'ISDN Backup, FR interface $1, RDSI interface $2' Parameters list: $1: frbk5-ifc-name $2: frbk5-isdn-ifc-name All traffic…
1.3.6.1.4.1.2007.1.4.114.2.0.6NotificationfrbkNotification6currentNotification of Event FRBK.6 Message: 'Return ISDN Backup, FR interface $1, RDSI interface $2' Parameters list: $1: frbk6-ifc-name $2: frbk6-isdn-ifc-name Fram…
1.3.6.1.4.1.2007.1.4.114.2.0.7NotificationfrbkNotification7currentNotification of Event FRBK.7 Message: 'ISDN Backup, PVC=$1 PVCBackup-ISDN=$2, FR interface $3 RDSI interface $4' Parameters list: $1: frbk7-circuit $2: frbk7-c…
1.3.6.1.4.1.2007.1.4.114.2.0.8NotificationfrbkNotification8currentNotification of Event FRBK.8 Message: 'Return ISDN-Backup, PVC=$1 PVCBackup-ISDN = $2, FR interface $3 RDSI interface $4' Parameters list: $1: frbk8-circuit $2…