TELDAT-TRAP-HDLC-MIB
74 objects
This Module Information Base file is defined for managing received SNMP notifications generated by the HDLC event subsystem.
Imported Objects
| SNMPv2-SMI | Integer32 IpAddress MODULE-IDENTITY NOTIFICATION-TYPE OBJECT-IDENTITY OBJECT-TYPE |
| SNMPv2-TC | DisplayString |
| TELDAT-MIB | telEventTraps |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.2007.1.4.190 | IdentityhdlcTrapsMIB | This Module Information Base file is defined for managing received SNMP notifications generated by the HDLC event subsystem. | ||
| 1.3.6.1.4.1.2007.1.4.190.1 | NodehdlcEventsGroup | |||
| 1.3.6.1.4.1.2007.1.4.190.1.1 | IdentityhdlcEventObjects1 | current | Event HDLC.1 Frame transmitted. | |
| 1.3.6.1.4.1.2007.1.4.190.1.1.1 | Scalarhdlc1-address | accessible-for-notify | current | Parameter 'address' in event HDLC.1 |
| 1.3.6.1.4.1.2007.1.4.190.1.1.2 | Scalarhdlc1-control | accessible-for-notify | current | Parameter 'control' in event HDLC.1 |
| 1.3.6.1.4.1.2007.1.4.190.1.1.3 | Scalarhdlc1-protocol | accessible-for-notify | current | Parameter 'protocol' in event HDLC.1 |
| 1.3.6.1.4.1.2007.1.4.190.1.1.4 | Scalarhdlc1-len | accessible-for-notify | current | Parameter 'len' in event HDLC.1 |
| 1.3.6.1.4.1.2007.1.4.190.1.1.5 | Scalarhdlc1-ifc-name | accessible-for-notify | current | Parameter 'ifc-name' in event HDLC.1 |
| 1.3.6.1.4.1.2007.1.4.190.1.2 | IdentityhdlcEventObjects2 | current | Event HDLC.2 Frame received. | |
| 1.3.6.1.4.1.2007.1.4.190.1.2.1 | Scalarhdlc2-address | accessible-for-notify | current | Parameter 'address' in event HDLC.2 |
| 1.3.6.1.4.1.2007.1.4.190.1.2.2 | Scalarhdlc2-control | accessible-for-notify | current | Parameter 'control' in event HDLC.2 |
| 1.3.6.1.4.1.2007.1.4.190.1.2.3 | Scalarhdlc2-protocol | accessible-for-notify | current | Parameter 'protocol' in event HDLC.2 |
| 1.3.6.1.4.1.2007.1.4.190.1.2.4 | Scalarhdlc2-len | accessible-for-notify | current | Parameter 'len' in event HDLC.2 |
| 1.3.6.1.4.1.2007.1.4.190.1.2.5 | Scalarhdlc2-ifc-name | accessible-for-notify | current | Parameter 'ifc-name' in event HDLC.2 |
| 1.3.6.1.4.1.2007.1.4.190.1.3 | IdentityhdlcEventObjects3 | current | Event HDLC.3 Keepalive state change | |
| 1.3.6.1.4.1.2007.1.4.190.1.3.1 | Scalarhdlc3-line-state | accessible-for-notify | current | Parameter 'line-state' in event HDLC.3 |
| 1.3.6.1.4.1.2007.1.4.190.1.3.2 | Scalarhdlc3-ifc-name | accessible-for-notify | current | Parameter 'ifc-name' in event HDLC.3 |
| 1.3.6.1.4.1.2007.1.4.190.1.4 | IdentityhdlcEventObjects4 | current | Event HDLC.4 Keepalive sequence transmitted. Status. | |
| 1.3.6.1.4.1.2007.1.4.190.1.4.1 | Scalarhdlc4-myseq | accessible-for-notify | current | Parameter 'myseq' in event HDLC.4 |
| 1.3.6.1.4.1.2007.1.4.190.1.4.2 | Scalarhdlc4-mineseen | accessible-for-notify | current | Parameter 'mineseen' in event HDLC.4 |
| 1.3.6.1.4.1.2007.1.4.190.1.4.3 | Scalarhdlc4-slarped | accessible-for-notify | current | Parameter 'slarped' in event HDLC.4 |
| 1.3.6.1.4.1.2007.1.4.190.1.4.4 | Scalarhdlc4-yoursseen | accessible-for-notify | current | Parameter 'yoursseen' in event HDLC.4 |
| 1.3.6.1.4.1.2007.1.4.190.1.4.5 | Scalarhdlc4-line-state | accessible-for-notify | current | Parameter 'line-state' in event HDLC.4 |
| 1.3.6.1.4.1.2007.1.4.190.1.4.6 | Scalarhdlc4-loop-state | accessible-for-notify | current | Parameter 'loop-state' in event HDLC.4 |
| 1.3.6.1.4.1.2007.1.4.190.1.4.7 | Scalarhdlc4-ifc-name | accessible-for-notify | current | Parameter 'ifc-name' in event HDLC.4 |
| 1.3.6.1.4.1.2007.1.4.190.1.5 | IdentityhdlcEventObjects5 | current | Event HDLC.5 Keepalive recived but none configured. | |
| 1.3.6.1.4.1.2007.1.4.190.1.5.1 | Scalarhdlc5-ifc-name | accessible-for-notify | current | Parameter 'ifc-name' in event HDLC.5 |
| 1.3.6.1.4.1.2007.1.4.190.1.6 | IdentityhdlcEventObjects6 | current | Event HDLC.6 Keepalive time mismatch | |
| 1.3.6.1.4.1.2007.1.4.190.1.6.1 | Scalarhdlc6-expected | accessible-for-notify | current | Parameter 'expected' in event HDLC.6 |
| 1.3.6.1.4.1.2007.1.4.190.1.6.2 | Scalarhdlc6-meassured | accessible-for-notify | current | Parameter 'meassured' in event HDLC.6 |
| 1.3.6.1.4.1.2007.1.4.190.1.6.3 | Scalarhdlc6-ifc-name | accessible-for-notify | current | Parameter 'ifc-name' in event HDLC.6 |
| 1.3.6.1.4.1.2007.1.4.190.1.7 | IdentityhdlcEventObjects7 | current | Event HDLC.7 Invalid length of control packet. | |
| 1.3.6.1.4.1.2007.1.4.190.1.7.1 | Scalarhdlc7-len | accessible-for-notify | current | Parameter 'len' in event HDLC.7 |
| 1.3.6.1.4.1.2007.1.4.190.1.7.2 | Scalarhdlc7-ifc-name | accessible-for-notify | current | Parameter 'ifc-name' in event HDLC.7 |
| 1.3.6.1.4.1.2007.1.4.190.1.8 | IdentityhdlcEventObjects8 | current | Event HDLC.8 Unexpected IP address reply. | |
| 1.3.6.1.4.1.2007.1.4.190.1.8.1 | Scalarhdlc8-ifc-name | accessible-for-notify | current | Parameter 'ifc-name' in event HDLC.8 |
| 1.3.6.1.4.1.2007.1.4.190.1.9 | IdentityhdlcEventObjects9 | current | Event HDLC.9 IP address request. | |
| 1.3.6.1.4.1.2007.1.4.190.1.9.1 | Scalarhdlc9-ifc-name | accessible-for-notify | current | Parameter 'ifc-name' in event HDLC.9 |
| 1.3.6.1.4.1.2007.1.4.190.1.10 | IdentityhdlcEventObjects10 | current | Event HDLC.10 Unsupported protocol. | |
| 1.3.6.1.4.1.2007.1.4.190.1.10.1 | Scalarhdlc10-protocol | accessible-for-notify | current | Parameter 'protocol' in event HDLC.10 |
| 1.3.6.1.4.1.2007.1.4.190.1.10.2 | Scalarhdlc10-ifc-name | accessible-for-notify | current | Parameter 'ifc-name' in event HDLC.10 |
| 1.3.6.1.4.1.2007.1.4.190.1.11 | IdentityhdlcEventObjects11 | current | Event HDLC.11 Invalid addr of control packet. | |
| 1.3.6.1.4.1.2007.1.4.190.1.11.1 | Scalarhdlc11-bad-add | accessible-for-notify | current | Parameter 'bad-add' in event HDLC.11 |
| 1.3.6.1.4.1.2007.1.4.190.1.11.2 | Scalarhdlc11-ifc-name | accessible-for-notify | current | Parameter 'ifc-name' in event HDLC.11 |
| 1.3.6.1.4.1.2007.1.4.190.1.12 | IdentityhdlcEventObjects12 | current | Event HDLC.12 Event received. | |
| 1.3.6.1.4.1.2007.1.4.190.1.12.1 | Scalarhdlc12-event | accessible-for-notify | current | Parameter 'event' in event HDLC.12 |
| 1.3.6.1.4.1.2007.1.4.190.1.12.2 | Scalarhdlc12-state | accessible-for-notify | current | Parameter 'state' in event HDLC.12 |
| 1.3.6.1.4.1.2007.1.4.190.1.12.3 | Scalarhdlc12-ifc-name | accessible-for-notify | current | Parameter 'ifc-name' in event HDLC.12 |
| 1.3.6.1.4.1.2007.1.4.190.1.13 | IdentityhdlcEventObjects13 | current | Event HDLC.13 FSM state change. | |
| 1.3.6.1.4.1.2007.1.4.190.1.13.1 | Scalarhdlc13-old-state | accessible-for-notify | current | Parameter 'old-state' in event HDLC.13 |
| 1.3.6.1.4.1.2007.1.4.190.1.13.2 | Scalarhdlc13-new-state | accessible-for-notify | current | Parameter 'new-state' in event HDLC.13 |
| 1.3.6.1.4.1.2007.1.4.190.1.13.3 | Scalarhdlc13-ifc-name | accessible-for-notify | current | Parameter 'ifc-name' in event HDLC.13 |
| 1.3.6.1.4.1.2007.1.4.190.1.14 | IdentityhdlcEventObjects14 | current | Event HDLC.14 Frame received dropped because Keepalive is down. | |
| 1.3.6.1.4.1.2007.1.4.190.1.14.1 | Scalarhdlc14-ifc-name | accessible-for-notify | current | Parameter 'ifc-name' in event HDLC.14 |
| 1.3.6.1.4.1.2007.1.4.190.1.15 | IdentityhdlcEventObjects15 | current | Event HDLC.15 Debug indication. | |
| 1.3.6.1.4.1.2007.1.4.190.1.15.1 | Scalarhdlc15-Debug-string | accessible-for-notify | current | Parameter 'Debug-string' in event HDLC.15 |
| 1.3.6.1.4.1.2007.1.4.190.1.15.2 | Scalarhdlc15-ifc-name | accessible-for-notify | current | Parameter 'ifc-name' in event HDLC.15 |
| 1.3.6.1.4.1.2007.1.4.190.2 | NodehdlcNotifications | |||
| 1.3.6.1.4.1.2007.1.4.190.2.0 | NodehdlcNotificationsPrefix | |||
| 1.3.6.1.4.1.2007.1.4.190.2.0.1 | NotificationhdlcNotification1 | current | Notification of Event HDLC.1 Message: 'Transmit frame address $1 control $2 protocol $3 len $4 on interface $5' Parameters list: $1: hdlc1-address $2: hdlc1-co… | |
| 1.3.6.1.4.1.2007.1.4.190.2.0.2 | NotificationhdlcNotification2 | current | Notification of Event HDLC.2 Message: 'Receive frame address $1 control $2 protocol $3 len $4 on interface $5' Parameters list: $1: hdlc2-address $2: hdlc2-con… | |
| 1.3.6.1.4.1.2007.1.4.190.2.0.3 | NotificationhdlcNotification3 | current | Notification of Event HDLC.3 Message: 'Keepalive change state to $1 on interface $2' Parameters list: $1: hdlc3-line-state $2: hdlc3-ifc-name Keepalive state c… | |
| 1.3.6.1.4.1.2007.1.4.190.2.0.4 | NotificationhdlcNotification4 | current | Notification of Event HDLC.4 Message: 'Keepalive myseq:$1 mineseen:$2$3 yoursseen:$4, line $5 $6 on interface $7' Parameters list: $1: hdlc4-myseq $2: hdlc4-mi… | |
| 1.3.6.1.4.1.2007.1.4.190.2.0.5 | NotificationhdlcNotification5 | current | Notification of Event HDLC.5 Message: 'Got keepalive with none configured on interface $1' Parameters list: $1: hdlc5-ifc-name Keepalive recived but none confi… | |
| 1.3.6.1.4.1.2007.1.4.190.2.0.6 | NotificationhdlcNotification6 | current | Notification of Event HDLC.6 Message: 'Keepalive time mismatch - should be $1 secs, is $2 on interface $3' Parameters list: $1: hdlc6-expected $2: hdlc6-meassu… | |
| 1.3.6.1.4.1.2007.1.4.190.2.0.7 | NotificationhdlcNotification7 | current | Notification of Event HDLC.7 Message: 'Invalid length of control packet ($1 bytes) on interface $2' Parameters list: $1: hdlc7-len $2: hdlc7-ifc-name Invalid l… | |
| 1.3.6.1.4.1.2007.1.4.190.2.0.8 | NotificationhdlcNotification8 | current | Notification of Event HDLC.8 Message: 'Unexpected IP address reply on interface $1' Parameters list: $1: hdlc8-ifc-name Unexpected IP address reply. | |
| 1.3.6.1.4.1.2007.1.4.190.2.0.9 | NotificationhdlcNotification9 | current | Notification of Event HDLC.9 Message: 'IP address request on interface $1' Parameters list: $1: hdlc9-ifc-name IP address request. | |
| 1.3.6.1.4.1.2007.1.4.190.2.0.10 | NotificationhdlcNotification10 | current | Notification of Event HDLC.10 Message: 'Unsupported protocol $1 on interface $2' Parameters list: $1: hdlc10-protocol $2: hdlc10-ifc-name Unsupported protocol. | |
| 1.3.6.1.4.1.2007.1.4.190.2.0.11 | NotificationhdlcNotification11 | current | Notification of Event HDLC.11 Message: 'Invalid address ($1) of control packet on interface $2' Parameters list: $1: hdlc11-bad-add $2: hdlc11-ifc-name Invalid… | |
| 1.3.6.1.4.1.2007.1.4.190.2.0.12 | NotificationhdlcNotification12 | current | Notification of Event HDLC.12 Message: 'Received event $1 on state $2 on interface $3' Parameters list: $1: hdlc12-event $2: hdlc12-state $3: hdlc12-ifc-name E… | |
| 1.3.6.1.4.1.2007.1.4.190.2.0.13 | NotificationhdlcNotification13 | current | Notification of Event HDLC.13 Message: 'FSM state change old state $1 new state $2 on interface $3' Parameters list: $1: hdlc13-old-state $2: hdlc13-new-state … | |
| 1.3.6.1.4.1.2007.1.4.190.2.0.14 | NotificationhdlcNotification14 | current | Notification of Event HDLC.14 Message: 'Drop frame on interface $1' Parameters list: $1: hdlc14-ifc-name Frame received dropped because Keepalive is down. | |
| 1.3.6.1.4.1.2007.1.4.190.2.0.15 | NotificationhdlcNotification15 | current | Notification of Event HDLC.15 Message: '$1 on interface $2' Parameters list: $1: hdlc15-Debug-string $2: hdlc15-ifc-name Debug indication. |