TELDAT-TRAP-LLC-MIB
178 objects
This Module Information Base file is defined for managing received SNMP notifications generated by the LLC event subsystem.
Imported Objects
| SNMPv2-SMI | Integer32 IpAddress MODULE-IDENTITY NOTIFICATION-TYPE OBJECT-IDENTITY OBJECT-TYPE |
| SNMPv2-TC | DisplayString |
| TELDAT-MIB | telEventTraps |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.2007.1.4.103 | IdentityllcTrapsMIB | This Module Information Base file is defined for managing received SNMP notifications generated by the LLC event subsystem. | ||
| 1.3.6.1.4.1.2007.1.4.103.1 | NodellcEventsGroup | |||
| 1.3.6.1.4.1.2007.1.4.103.1.1 | IdentityllcEventObjects1 | current | Event LLC.1 LLC is sending a frame. Possible frame types are: SABME-C0 or SABME-C1 (Set Asynchronous Balanced Mode Extended), DM-R0 or DM-R1 (Disconnected Mode… | |
| 1.3.6.1.4.1.2007.1.4.103.1.1.1 | Scalarllc1-frame-type | accessible-for-notify | current | Parameter 'frame-type' in event LLC.1 |
| 1.3.6.1.4.1.2007.1.4.103.1.1.2 | Scalarllc1-src-mac | accessible-for-notify | current | Parameter 'src-mac' in event LLC.1 |
| 1.3.6.1.4.1.2007.1.4.103.1.1.3 | Scalarllc1-dst-mac | accessible-for-notify | current | Parameter 'dst-mac' in event LLC.1 |
| 1.3.6.1.4.1.2007.1.4.103.1.1.4 | Scalarllc1-rif | accessible-for-notify | current | Parameter 'rif' in event LLC.1 |
| 1.3.6.1.4.1.2007.1.4.103.1.1.5 | Scalarllc1-src-sap | accessible-for-notify | current | Parameter 'src-sap' in event LLC.1 |
| 1.3.6.1.4.1.2007.1.4.103.1.1.6 | Scalarllc1-dst-sap | accessible-for-notify | current | Parameter 'dst-sap' in event LLC.1 |
| 1.3.6.1.4.1.2007.1.4.103.1.1.7 | Scalarllc1-interface | accessible-for-notify | current | Parameter 'interface' in event LLC.1 |
| 1.3.6.1.4.1.2007.1.4.103.1.2 | IdentityllcEventObjects2 | current | Event LLC.2 An event occurred on an llc2 connection. The LLC2 FSM (Finite State Machine) has been called to process the event. The LLC2 connection is uniquely … | |
| 1.3.6.1.4.1.2007.1.4.103.1.2.1 | Scalarllc2-llc-event | accessible-for-notify | current | Parameter 'llc-event' in event LLC.2 |
| 1.3.6.1.4.1.2007.1.4.103.1.2.2 | Scalarllc2-llc-state | accessible-for-notify | current | Parameter 'llc-state' in event LLC.2 |
| 1.3.6.1.4.1.2007.1.4.103.1.2.3 | Scalarllc2-llc2-connection | accessible-for-notify | current | Parameter 'llc2-connection' in event LLC.2 |
| 1.3.6.1.4.1.2007.1.4.103.1.2.4 | Scalarllc2-llc2-sap | accessible-for-notify | current | Parameter 'llc2-sap' in event LLC.2 |
| 1.3.6.1.4.1.2007.1.4.103.1.2.5 | Scalarllc2-interface | accessible-for-notify | current | Parameter 'interface' in event LLC.2 |
| 1.3.6.1.4.1.2007.1.4.103.1.3 | IdentityllcEventObjects3 | current | Event LLC.3 There is LLC2 state change. The possible states are: DISCONNECTED (initial state), LINK-OPENING (link establishment in progress), DISCONNECTING (DI… | |
| 1.3.6.1.4.1.2007.1.4.103.1.3.1 | Scalarllc3-llc-old-state | accessible-for-notify | current | Parameter 'llc-old-state' in event LLC.3 |
| 1.3.6.1.4.1.2007.1.4.103.1.3.2 | Scalarllc3-llc-new-state | accessible-for-notify | current | Parameter 'llc-new-state' in event LLC.3 |
| 1.3.6.1.4.1.2007.1.4.103.1.3.3 | Scalarllc3-llc2-connection | accessible-for-notify | current | Parameter 'llc2-connection' in event LLC.3 |
| 1.3.6.1.4.1.2007.1.4.103.1.3.4 | Scalarllc3-llc2-sap | accessible-for-notify | current | Parameter 'llc2-sap' in event LLC.3 |
| 1.3.6.1.4.1.2007.1.4.103.1.3.5 | Scalarllc3-interface | accessible-for-notify | current | Parameter 'interface' in event LLC.3 |
| 1.3.6.1.4.1.2007.1.4.103.1.4 | IdentityllcEventObjects4 | current | Event LLC.4 LLC2 event upcall is occuring. Some of the arguments on the upcall are shown. User Cookie is meaningful to the router software running over the LLC… | |
| 1.3.6.1.4.1.2007.1.4.103.1.4.1 | Scalarllc4-user-event | accessible-for-notify | current | Parameter 'user-event' in event LLC.4 |
| 1.3.6.1.4.1.2007.1.4.103.1.4.2 | Scalarllc4-user-value | accessible-for-notify | current | Parameter 'user-value' in event LLC.4 |
| 1.3.6.1.4.1.2007.1.4.103.1.4.3 | Scalarllc4-event-reason | accessible-for-notify | current | Parameter 'event-reason' in event LLC.4 |
| 1.3.6.1.4.1.2007.1.4.103.1.4.4 | Scalarllc4-llc2-connection | accessible-for-notify | current | Parameter 'llc2-connection' in event LLC.4 |
| 1.3.6.1.4.1.2007.1.4.103.1.4.5 | Scalarllc4-llc2-sap | accessible-for-notify | current | Parameter 'llc2-sap' in event LLC.4 |
| 1.3.6.1.4.1.2007.1.4.103.1.4.6 | Scalarllc4-interface | accessible-for-notify | current | Parameter 'interface' in event LLC.4 |
| 1.3.6.1.4.1.2007.1.4.103.1.5 | IdentityllcEventObjects5 | current | Event LLC.5 A sap-releated LLC user-primitive was called. The possible SAP primitives are: OPEN-SAP, CLOSE-SAP, CLOSE-SAP-FORCED, MODIFY-SAP, OPEN-STATION, and… | |
| 1.3.6.1.4.1.2007.1.4.103.1.5.1 | Scalarllc5-user-primitive | accessible-for-notify | current | Parameter 'user-primitive' in event LLC.5 |
| 1.3.6.1.4.1.2007.1.4.103.1.5.2 | Scalarllc5-SAP-value | accessible-for-notify | current | Parameter 'SAP-value' in event LLC.5 |
| 1.3.6.1.4.1.2007.1.4.103.1.5.3 | Scalarllc5-interface | accessible-for-notify | current | Parameter 'interface' in event LLC.5 |
| 1.3.6.1.4.1.2007.1.4.103.1.6 | IdentityllcEventObjects6 | current | Event LLC.6 A llc2 connection non-data user-primitive was called. The possible primitives are: CLOSE-STATION, CLOSE-STATION-FORCED, CONNECT-REQUEST, CONNECT-RE… | |
| 1.3.6.1.4.1.2007.1.4.103.1.6.1 | Scalarllc6-user-primitive | accessible-for-notify | current | Parameter 'user-primitive' in event LLC.6 |
| 1.3.6.1.4.1.2007.1.4.103.1.6.2 | Scalarllc6-llc2-connection | accessible-for-notify | current | Parameter 'llc2-connection' in event LLC.6 |
| 1.3.6.1.4.1.2007.1.4.103.1.6.3 | Scalarllc6-llc2-sap | accessible-for-notify | current | Parameter 'llc2-sap' in event LLC.6 |
| 1.3.6.1.4.1.2007.1.4.103.1.6.4 | Scalarllc6-interface | accessible-for-notify | current | Parameter 'interface' in event LLC.6 |
| 1.3.6.1.4.1.2007.1.4.103.1.7 | IdentityllcEventObjects7 | current | Event LLC.7 A DATA-REQUEST data primitive was called. DATA-REQUEST passes the data in buffer memory. | |
| 1.3.6.1.4.1.2007.1.4.103.1.7.1 | Scalarllc7-llc2-connection | accessible-for-notify | current | Parameter 'llc2-connection' in event LLC.7 |
| 1.3.6.1.4.1.2007.1.4.103.1.7.2 | Scalarllc7-llc2-sap | accessible-for-notify | current | Parameter 'llc2-sap' in event LLC.7 |
| 1.3.6.1.4.1.2007.1.4.103.1.7.3 | Scalarllc7-interface | accessible-for-notify | current | Parameter 'interface' in event LLC.7 |
| 1.3.6.1.4.1.2007.1.4.103.1.8 | IdentityllcEventObjects8 | current | Event LLC.8 A DATA-LOCAL data primitive was called. DATA-LOCAL passes the data in data memory. | |
| 1.3.6.1.4.1.2007.1.4.103.1.8.1 | Scalarllc8-llc2-connection | accessible-for-notify | current | Parameter 'llc2-connection' in event LLC.8 |
| 1.3.6.1.4.1.2007.1.4.103.1.8.2 | Scalarllc8-llc2-sap | accessible-for-notify | current | Parameter 'llc2-sap' in event LLC.8 |
| 1.3.6.1.4.1.2007.1.4.103.1.8.3 | Scalarllc8-interface | accessible-for-notify | current | Parameter 'interface' in event LLC.8 |
| 1.3.6.1.4.1.2007.1.4.103.1.9 | IdentityllcEventObjects9 | current | Event LLC.9 A UNITDATA llc1 data primitive was called. | |
| 1.3.6.1.4.1.2007.1.4.103.1.9.1 | Scalarllc9-SAP-value | accessible-for-notify | current | Parameter 'SAP-value' in event LLC.9 |
| 1.3.6.1.4.1.2007.1.4.103.1.9.2 | Scalarllc9-interface | accessible-for-notify | current | Parameter 'interface' in event LLC.9 |
| 1.3.6.1.4.1.2007.1.4.103.1.10 | IdentityllcEventObjects10 | current | Event LLC.10 The oubound queue has grown grossly large. The llc2 connection is being automatically terminated. | |
| 1.3.6.1.4.1.2007.1.4.103.1.10.1 | Scalarllc10-llc2-connection | accessible-for-notify | current | Parameter 'llc2-connection' in event LLC.10 |
| 1.3.6.1.4.1.2007.1.4.103.1.10.2 | Scalarllc10-llc2-sap | accessible-for-notify | current | Parameter 'llc2-sap' in event LLC.10 |
| 1.3.6.1.4.1.2007.1.4.103.1.10.3 | Scalarllc10-interface | accessible-for-notify | current | Parameter 'interface' in event LLC.10 |
| 1.3.6.1.4.1.2007.1.4.103.1.11 | IdentityllcEventObjects11 | current | Event LLC.11 No buffer available to duplicate I-frame. | |
| 1.3.6.1.4.1.2007.1.4.103.1.11.1 | Scalarllc11-llc2-connection | accessible-for-notify | current | Parameter 'llc2-connection' in event LLC.11 |
| 1.3.6.1.4.1.2007.1.4.103.1.11.2 | Scalarllc11-llc2-sap | accessible-for-notify | current | Parameter 'llc2-sap' in event LLC.11 |
| 1.3.6.1.4.1.2007.1.4.103.1.11.3 | Scalarllc11-interface | accessible-for-notify | current | Parameter 'interface' in event LLC.11 |
| 1.3.6.1.4.1.2007.1.4.103.1.12 | IdentityllcEventObjects12 | current | Event LLC.12 No memory to duplicate I-frame. | |
| 1.3.6.1.4.1.2007.1.4.103.1.12.1 | Scalarllc12-llc2-connection | accessible-for-notify | current | Parameter 'llc2-connection' in event LLC.12 |
| 1.3.6.1.4.1.2007.1.4.103.1.12.2 | Scalarllc12-llc2-sap | accessible-for-notify | current | Parameter 'llc2-sap' in event LLC.12 |
| 1.3.6.1.4.1.2007.1.4.103.1.12.3 | Scalarllc12-interface | accessible-for-notify | current | Parameter 'interface' in event LLC.12 |
| 1.3.6.1.4.1.2007.1.4.103.1.13 | IdentityllcEventObjects13 | current | Event LLC.13 A buffer could not be obtained to to build an LLC Supervisory or Unnumbered frame. No loss of data integrity has occurred yet, but unless buffers … | |
| 1.3.6.1.4.1.2007.1.4.103.1.13.1 | Scalarllc13-llc2-connection | accessible-for-notify | current | Parameter 'llc2-connection' in event LLC.13 |
| 1.3.6.1.4.1.2007.1.4.103.1.13.2 | Scalarllc13-llc2-sap | accessible-for-notify | current | Parameter 'llc2-sap' in event LLC.13 |
| 1.3.6.1.4.1.2007.1.4.103.1.13.3 | Scalarllc13-interface | accessible-for-notify | current | Parameter 'interface' in event LLC.13 |
| 1.3.6.1.4.1.2007.1.4.103.1.14 | IdentityllcEventObjects14 | current | Event LLC.14 The frame type the LLC is trying to build is invalid. | |
| 1.3.6.1.4.1.2007.1.4.103.1.14.1 | Scalarllc14-llc2-connection | accessible-for-notify | current | Parameter 'llc2-connection' in event LLC.14 |
| 1.3.6.1.4.1.2007.1.4.103.1.14.2 | Scalarllc14-llc2-sap | accessible-for-notify | current | Parameter 'llc2-sap' in event LLC.14 |
| 1.3.6.1.4.1.2007.1.4.103.1.14.3 | Scalarllc14-interface | accessible-for-notify | current | Parameter 'interface' in event LLC.14 |
| 1.3.6.1.4.1.2007.1.4.103.1.15 | IdentityllcEventObjects15 | current | Event LLC.15 The LLC2 Finite State Machine (FSM) was called with an event that was out of range. | |
| 1.3.6.1.4.1.2007.1.4.103.1.15.1 | Scalarllc15-event-code-number | accessible-for-notify | current | Parameter 'event-code-number' in event LLC.15 |
| 1.3.6.1.4.1.2007.1.4.103.1.16 | IdentityllcEventObjects16 | current | Event LLC.16 An OPEN SAP operation was tried on a network type that LLC does not support. Network types Token-Ring, Ethernet, and FDDI are supported. | |
| 1.3.6.1.4.1.2007.1.4.103.1.16.1 | Scalarllc16-network-type | accessible-for-notify | current | Parameter 'network-type' in event LLC.16 |
| 1.3.6.1.4.1.2007.1.4.103.1.16.2 | Scalarllc16-interface | accessible-for-notify | current | Parameter 'interface' in event LLC.16 |
| 1.3.6.1.4.1.2007.1.4.103.1.17 | IdentityllcEventObjects17 | current | Event LLC.17 A OPEN SAP operation was tried on a sap that has already been opened. | |
| 1.3.6.1.4.1.2007.1.4.103.1.17.1 | Scalarllc17-SAP-value | accessible-for-notify | current | Parameter 'SAP-value' in event LLC.17 |
| 1.3.6.1.4.1.2007.1.4.103.1.17.2 | Scalarllc17-interface | accessible-for-notify | current | Parameter 'interface' in event LLC.17 |
| 1.3.6.1.4.1.2007.1.4.103.1.18 | IdentityllcEventObjects18 | current | Event LLC.18 Unable to allocate memory for SAP control block. | |
| 1.3.6.1.4.1.2007.1.4.103.1.18.1 | Scalarllc18-interface | accessible-for-notify | current | Parameter 'interface' in event LLC.18 |
| 1.3.6.1.4.1.2007.1.4.103.1.19 | IdentityllcEventObjects19 | current | Event LLC.19 Unable to allocate memory for station control block. | |
| 1.3.6.1.4.1.2007.1.4.103.1.19.1 | Scalarllc19-interface | accessible-for-notify | current | Parameter 'interface' in event LLC.19 |
| 1.3.6.1.4.1.2007.1.4.103.1.20 | IdentityllcEventObjects20 | current | Event LLC.20 UI frame refused by the local application within the router. | |
| 1.3.6.1.4.1.2007.1.4.103.1.20.1 | Scalarllc20-llc2-connection | accessible-for-notify | current | Parameter 'llc2-connection' in event LLC.20 |
| 1.3.6.1.4.1.2007.1.4.103.1.20.2 | Scalarllc20-llc2-sap | accessible-for-notify | current | Parameter 'llc2-sap' in event LLC.20 |
| 1.3.6.1.4.1.2007.1.4.103.1.20.3 | Scalarllc20-interface | accessible-for-notify | current | Parameter 'interface' in event LLC.20 |
| 1.3.6.1.4.1.2007.1.4.103.1.21 | IdentityllcEventObjects21 | current | Event LLC.21 TEST frame refused by the local application within the router. The frame is passed on to the bridge code, etc. | |
| 1.3.6.1.4.1.2007.1.4.103.1.21.1 | Scalarllc21-llc2-connection | accessible-for-notify | current | Parameter 'llc2-connection' in event LLC.21 |
| 1.3.6.1.4.1.2007.1.4.103.1.21.2 | Scalarllc21-llc2-sap | accessible-for-notify | current | Parameter 'llc2-sap' in event LLC.21 |
| 1.3.6.1.4.1.2007.1.4.103.1.21.3 | Scalarllc21-interface | accessible-for-notify | current | Parameter 'interface' in event LLC.21 |
| 1.3.6.1.4.1.2007.1.4.103.1.22 | IdentityllcEventObjects22 | current | Event LLC.22 XID frame refused by the local application within the router. The frame is passed on to the bridge code, etc. | |
| 1.3.6.1.4.1.2007.1.4.103.1.22.1 | Scalarllc22-llc2-connection | accessible-for-notify | current | Parameter 'llc2-connection' in event LLC.22 |
| 1.3.6.1.4.1.2007.1.4.103.1.22.2 | Scalarllc22-llc2-sap | accessible-for-notify | current | Parameter 'llc2-sap' in event LLC.22 |
| 1.3.6.1.4.1.2007.1.4.103.1.22.3 | Scalarllc22-interface | accessible-for-notify | current | Parameter 'interface' in event LLC.22 |
| 1.3.6.1.4.1.2007.1.4.103.1.23 | IdentityllcEventObjects23 | current | Event LLC.23 LLC makes an upcall providing the LLC with a unitdata frame. The possible unitdata frames are: TEST-C0 or TEST-C1 or TEST-R0 or TEST-R1 (TEST fram… | |
| 1.3.6.1.4.1.2007.1.4.103.1.23.1 | Scalarllc23-frame-type | accessible-for-notify | current | Parameter 'frame-type' in event LLC.23 |
| 1.3.6.1.4.1.2007.1.4.103.1.23.2 | Scalarllc23-src-mac | accessible-for-notify | current | Parameter 'src-mac' in event LLC.23 |
| 1.3.6.1.4.1.2007.1.4.103.1.23.3 | Scalarllc23-dst-mac | accessible-for-notify | current | Parameter 'dst-mac' in event LLC.23 |
| 1.3.6.1.4.1.2007.1.4.103.1.23.4 | Scalarllc23-rif | accessible-for-notify | current | Parameter 'rif' in event LLC.23 |
| 1.3.6.1.4.1.2007.1.4.103.1.23.5 | Scalarllc23-src-sap | accessible-for-notify | current | Parameter 'src-sap' in event LLC.23 |
| 1.3.6.1.4.1.2007.1.4.103.1.23.6 | Scalarllc23-dst-sap | accessible-for-notify | current | Parameter 'dst-sap' in event LLC.23 |
| 1.3.6.1.4.1.2007.1.4.103.1.23.7 | Scalarllc23-interface | accessible-for-notify | current | Parameter 'interface' in event LLC.23 |
| 1.3.6.1.4.1.2007.1.4.103.1.24 | IdentityllcEventObjects24 | current | Event LLC.24 The sending of an LLC2 related outbound frame failed. The reason-code is the internal error code for the failure. | |
| 1.3.6.1.4.1.2007.1.4.103.1.24.1 | Scalarllc24-reason-code | accessible-for-notify | current | Parameter 'reason-code' in event LLC.24 |
| 1.3.6.1.4.1.2007.1.4.103.1.24.2 | Scalarllc24-llc2-connection | accessible-for-notify | current | Parameter 'llc2-connection' in event LLC.24 |
| 1.3.6.1.4.1.2007.1.4.103.1.24.3 | Scalarllc24-llc2-sap | accessible-for-notify | current | Parameter 'llc2-sap' in event LLC.24 |
| 1.3.6.1.4.1.2007.1.4.103.1.24.4 | Scalarllc24-interface-name | accessible-for-notify | current | Parameter 'interface-name' in event LLC.24 |
| 1.3.6.1.4.1.2007.1.4.103.1.25 | IdentityllcEventObjects25 | current | Event LLC.25 The sending of the user's UNITDATA or an LLC-generated XID or TEST response outbound frame failed. The possible frame test are: TEST-C0 or TEST-C1… | |
| 1.3.6.1.4.1.2007.1.4.103.1.25.1 | Scalarllc25-frame-type | accessible-for-notify | current | Parameter 'frame-type' in event LLC.25 |
| 1.3.6.1.4.1.2007.1.4.103.1.25.2 | Scalarllc25-reason-code | accessible-for-notify | current | Parameter 'reason-code' in event LLC.25 |
| 1.3.6.1.4.1.2007.1.4.103.1.25.3 | Scalarllc25-llc2-connection | accessible-for-notify | current | Parameter 'llc2-connection' in event LLC.25 |
| 1.3.6.1.4.1.2007.1.4.103.1.25.4 | Scalarllc25-llc2-sap | accessible-for-notify | current | Parameter 'llc2-sap' in event LLC.25 |
| 1.3.6.1.4.1.2007.1.4.103.1.25.5 | Scalarllc25-interface | accessible-for-notify | current | Parameter 'interface' in event LLC.25 |
| 1.3.6.1.4.1.2007.1.4.103.1.26 | IdentityllcEventObjects26 | current | Event LLC.26 Unable to allocate memory for an LLC-CONF-BLOCK at initialization time. LLC configuration defaults are used. | |
| 1.3.6.1.4.1.2007.1.4.103.1.26.1 | Scalarllc26-interface | accessible-for-notify | current | Parameter 'interface' in event LLC.26 |
| 1.3.6.1.4.1.2007.1.4.103.1.27 | IdentityllcEventObjects27 | current | Event LLC.27 LLC Configuration record read for this network. This only occurs at initialization time. The values in the LLC configuration record are used as de… | |
| 1.3.6.1.4.1.2007.1.4.103.1.27.1 | Scalarllc27-interface | accessible-for-notify | current | Parameter 'interface' in event LLC.27 |
| 1.3.6.1.4.1.2007.1.4.103.1.28 | IdentityllcEventObjects28 | current | Event LLC.28 access-priority, on an interface that is not a token ring must be zero because it is not used. | |
| 1.3.6.1.4.1.2007.1.4.103.1.28.1 | Scalarllc28-access-priority | accessible-for-notify | current | Parameter 'access-priority' in event LLC.28 |
| 1.3.6.1.4.1.2007.1.4.103.1.28.2 | Scalarllc28-interface | accessible-for-notify | current | Parameter 'interface' in event LLC.28 |
| 1.3.6.1.4.1.2007.1.4.103.1.29 | IdentityllcEventObjects29 | current | Event LLC.29 The access priority is greater than 7. A default of 0 is used. | |
| 1.3.6.1.4.1.2007.1.4.103.1.29.1 | Scalarllc29-access-priority | accessible-for-notify | current | Parameter 'access-priority' in event LLC.29 |
| 1.3.6.1.4.1.2007.1.4.103.1.29.2 | Scalarllc29-interface | accessible-for-notify | current | Parameter 'interface' in event LLC.29 |
| 1.3.6.1.4.1.2007.1.4.103.1.30 | IdentityllcEventObjects30 | current | Event LLC.30 An LLC config record exists for an interface that does not have a LAN hardware type. | |
| 1.3.6.1.4.1.2007.1.4.103.1.30.1 | Scalarllc30-hardware-type | accessible-for-notify | current | Parameter 'hardware-type' in event LLC.30 |
| 1.3.6.1.4.1.2007.1.4.103.1.30.2 | Scalarllc30-interface | accessible-for-notify | current | Parameter 'interface' in event LLC.30 |
| 1.3.6.1.4.1.2007.1.4.103.1.31 | IdentityllcEventObjects31 | current | Event LLC.31 An LLC config record exists for an interface that does not exist. | |
| 1.3.6.1.4.1.2007.1.4.103.1.31.1 | Scalarllc31-interface-number | accessible-for-notify | current | Parameter 'interface-number' in event LLC.31 |
| 1.3.6.1.4.1.2007.1.4.103.1.32 | IdentityllcEventObjects32 | current | Event LLC.32 LLC user is sending a frame, or LLC itself is sending a TEST or XID response frame. The possible frame types are: TEST-C0 or TEST-C1 or TEST-R0 or… | |
| 1.3.6.1.4.1.2007.1.4.103.1.32.1 | Scalarllc32-frame-type | accessible-for-notify | current | Parameter 'frame-type' in event LLC.32 |
| 1.3.6.1.4.1.2007.1.4.103.1.32.2 | Scalarllc32-src-mac | accessible-for-notify | current | Parameter 'src-mac' in event LLC.32 |
| 1.3.6.1.4.1.2007.1.4.103.1.32.3 | Scalarllc32-dst-mac | accessible-for-notify | current | Parameter 'dst-mac' in event LLC.32 |
| 1.3.6.1.4.1.2007.1.4.103.1.32.4 | Scalarllc32-rif | accessible-for-notify | current | Parameter 'rif' in event LLC.32 |
| 1.3.6.1.4.1.2007.1.4.103.1.32.5 | Scalarllc32-src-sap | accessible-for-notify | current | Parameter 'src-sap' in event LLC.32 |
| 1.3.6.1.4.1.2007.1.4.103.1.32.6 | Scalarllc32-dst-sap | accessible-for-notify | current | Parameter 'dst-sap' in event LLC.32 |
| 1.3.6.1.4.1.2007.1.4.103.1.32.7 | Scalarllc32-interface | accessible-for-notify | current | Parameter 'interface' in event LLC.32 |
| 1.3.6.1.4.1.2007.1.4.103.1.33 | IdentityllcEventObjects33 | current | Event LLC.33 LLC subsystem itself is responding to a TEST or XID frame. The possible frame types are: TEST-C0 or TEST-C1 (TEST frame), and XID-C0 or XID-C1 (Ex… | |
| 1.3.6.1.4.1.2007.1.4.103.1.33.1 | Scalarllc33-frame-type | accessible-for-notify | current | Parameter 'frame-type' in event LLC.33 |
| 1.3.6.1.4.1.2007.1.4.103.1.33.2 | Scalarllc33-src-mac | accessible-for-notify | current | Parameter 'src-mac' in event LLC.33 |
| 1.3.6.1.4.1.2007.1.4.103.1.33.3 | Scalarllc33-dst-mac | accessible-for-notify | current | Parameter 'dst-mac' in event LLC.33 |
| 1.3.6.1.4.1.2007.1.4.103.1.33.4 | Scalarllc33-rif | accessible-for-notify | current | Parameter 'rif' in event LLC.33 |
| 1.3.6.1.4.1.2007.1.4.103.1.33.5 | Scalarllc33-src-sap | accessible-for-notify | current | Parameter 'src-sap' in event LLC.33 |
| 1.3.6.1.4.1.2007.1.4.103.1.33.6 | Scalarllc33-dst-sap | accessible-for-notify | current | Parameter 'dst-sap' in event LLC.33 |
| 1.3.6.1.4.1.2007.1.4.103.1.33.7 | Scalarllc33-interface | accessible-for-notify | current | Parameter 'interface' in event LLC.33 |
| 1.3.6.1.4.1.2007.1.4.103.2 | NodellcNotifications | |||
| 1.3.6.1.4.1.2007.1.4.103.2.0 | NodellcNotificationsPrefix | |||
| 1.3.6.1.4.1.2007.1.4.103.2.0.1 | NotificationllcNotification1 | current | Notification of Event LLC.1 Message: 'Sent $1, $2->$3, $4 saps $5->$6, interface $7' Parameters list: $1: llc1-frame-type $2: llc1-src-mac $3: llc1-dst-mac $4:… | |
| 1.3.6.1.4.1.2007.1.4.103.2.0.2 | NotificationllcNotification2 | current | Notification of Event LLC.2 Message: 'event=$1 in state=$2, $3->$4, saps $5->$6, interface $7' Parameters list: $1: llc2-llc-event $2: llc2-llc-state $3: llc2-… | |
| 1.3.6.1.4.1.2007.1.4.103.2.0.3 | NotificationllcNotification3 | current | Notification of Event LLC.3 Message: '$1 to $2, $3->$4, saps $5->$6, interface $7' Parameters list: $1: llc3-llc-old-state $2: llc3-llc-new-state $3: llc3-llc2… | |
| 1.3.6.1.4.1.2007.1.4.103.2.0.4 | NotificationllcNotification4 | current | Notification of Event LLC.4 Message: 'Upcall user event $1 args $2/$3 on $4->$5, saps $6->$7, interface $8' Parameters list: $1: llc4-user-event $2: llc4-user-… | |
| 1.3.6.1.4.1.2007.1.4.103.2.0.5 | NotificationllcNotification5 | current | Notification of Event LLC.5 Message: 'user primitive $1 sap $2 on interface $3' Parameters list: $1: llc5-user-primitive $2: llc5-SAP-value $3: llc5-interface … | |
| 1.3.6.1.4.1.2007.1.4.103.2.0.6 | NotificationllcNotification6 | current | Notification of Event LLC.6 Message: 'primitive $1, $2->$3, saps $4->$5, interface $6' Parameters list: $1: llc6-user-primitive $2: llc6-llc2-connection $3: ll… | |
| 1.3.6.1.4.1.2007.1.4.103.2.0.7 | NotificationllcNotification7 | current | Notification of Event LLC.7 Message: 'data primitive, $1->$2, saps $3->$4, interface $5' Parameters list: $1: llc7-llc2-connection $2: llc7-llc2-connection $3:… | |
| 1.3.6.1.4.1.2007.1.4.103.2.0.8 | NotificationllcNotification8 | current | Notification of Event LLC.8 Message: 'data primitive, $1->$2, saps $3->$4, interface $5' Parameters list: $1: llc8-llc2-connection $2: llc8-llc2-connection $3:… | |
| 1.3.6.1.4.1.2007.1.4.103.2.0.9 | NotificationllcNotification9 | current | Notification of Event LLC.9 Message: 'unitdata primitive, sap $1 interface $2' Parameters list: $1: llc9-SAP-value $2: llc9-interface A UNITDATA llc1 data prim… | |
| 1.3.6.1.4.1.2007.1.4.103.2.0.10 | NotificationllcNotification10 | current | Notification of Event LLC.10 Message: 'outbound queue too big, $1->$2, saps $3->$4, interface $5' Parameters list: $1: llc10-llc2-connection $2: llc10-llc2-con… | |
| 1.3.6.1.4.1.2007.1.4.103.2.0.11 | NotificationllcNotification11 | current | Notification of Event LLC.11 Message: 'No buffer available to duplicate I-frame, $1->$2, saps $3->$4, interface $5' Parameters list: $1: llc11-llc2-connection … | |
| 1.3.6.1.4.1.2007.1.4.103.2.0.12 | NotificationllcNotification12 | current | Notification of Event LLC.12 Message: 'No memory available to duplicate I-frame, $1->$2, saps $3->$4, interface $5' Parameters list: $1: llc12-llc2-connection … | |
| 1.3.6.1.4.1.2007.1.4.103.2.0.13 | NotificationllcNotification13 | current | Notification of Event LLC.13 Message: 'No buffer for LLC frame, $1->$2, saps $3->$4, interface $5' Parameters list: $1: llc13-llc2-connection $2: llc13-llc2-co… | |
| 1.3.6.1.4.1.2007.1.4.103.2.0.14 | NotificationllcNotification14 | current | Notification of Event LLC.14 Message: 'frame type invalid, $1->$2, saps $3->$4, interface $5' Parameters list: $1: llc14-llc2-connection $2: llc14-llc2-connect… | |
| 1.3.6.1.4.1.2007.1.4.103.2.0.15 | NotificationllcNotification15 | current | Notification of Event LLC.15 Message: 'Invalid LLC2 FSM event $1' Parameters list: $1: llc15-event-code-number The LLC2 Finite State Machine (FSM) was called w… | |
| 1.3.6.1.4.1.2007.1.4.103.2.0.16 | NotificationllcNotification16 | current | Notification of Event LLC.16 Message: 'invalid network type $1 on interface $2' Parameters list: $1: llc16-network-type $2: llc16-interface An OPEN SAP operati… | |
| 1.3.6.1.4.1.2007.1.4.103.2.0.17 | NotificationllcNotification17 | current | Notification of Event LLC.17 Message: 'duplicate sap $1 on interface $2' Parameters list: $1: llc17-SAP-value $2: llc17-interface A OPEN SAP operation was trie… | |
| 1.3.6.1.4.1.2007.1.4.103.2.0.18 | NotificationllcNotification18 | current | Notification of Event LLC.18 Message: 'No memory for SAP control block on interface $1' Parameters list: $1: llc18-interface Unable to allocate memory for SAP … | |
| 1.3.6.1.4.1.2007.1.4.103.2.0.19 | NotificationllcNotification19 | current | Notification of Event LLC.19 Message: 'No memory for station control block on interface $1' Parameters list: $1: llc19-interface Unable to allocate memory for … | |
| 1.3.6.1.4.1.2007.1.4.103.2.0.20 | NotificationllcNotification20 | current | Notification of Event LLC.20 Message: 'UI frame dropped, $1->$2, saps $3->$4, interface $5' Parameters list: $1: llc20-llc2-connection $2: llc20-llc2-connectio… | |
| 1.3.6.1.4.1.2007.1.4.103.2.0.21 | NotificationllcNotification21 | current | Notification of Event LLC.21 Message: 'TEST frame refused, $1->$2, saps $3->$4, interface $5' Parameters list: $1: llc21-llc2-connection $2: llc21-llc2-connect… | |
| 1.3.6.1.4.1.2007.1.4.103.2.0.22 | NotificationllcNotification22 | current | Notification of Event LLC.22 Message: 'XID frame refused, $1->$2, saps $3->$4, interface $5' Parameters list: $1: llc22-llc2-connection $2: llc22-llc2-connecti… | |
| 1.3.6.1.4.1.2007.1.4.103.2.0.23 | NotificationllcNotification23 | current | Notification of Event LLC.23 Message: 'Upcall frame $1, $2->$3, $4 saps $5->$6, interface $7' Parameters list: $1: llc23-frame-type $2: llc23-src-mac $3: llc23… | |
| 1.3.6.1.4.1.2007.1.4.103.2.0.24 | NotificationllcNotification24 | current | Notification of Event LLC.24 Message: 'llc2 outbound frame dropped, reason $1, $2->$3, saps $4->$5, interface $6' Parameters list: $1: llc24-reason-code $2: ll… | |
| 1.3.6.1.4.1.2007.1.4.103.2.0.25 | NotificationllcNotification25 | current | Notification of Event LLC.25 Message: '$1 outbound frame dropped, reason $2, $3->$4, saps $5->$6, interface $7' Parameters list: $1: llc25-frame-type $2: llc25… | |
| 1.3.6.1.4.1.2007.1.4.103.2.0.26 | NotificationllcNotification26 | current | Notification of Event LLC.26 Message: 'No memory for LLC CONF BLOCK on interface $1' Parameters list: $1: llc26-interface Unable to allocate memory for an LLC-… | |
| 1.3.6.1.4.1.2007.1.4.103.2.0.27 | NotificationllcNotification27 | current | Notification of Event LLC.27 Message: 'Read LLC Configuration record for interface $1' Parameters list: $1: llc27-interface LLC Configuration record read for t… | |
| 1.3.6.1.4.1.2007.1.4.103.2.0.28 | NotificationllcNotification28 | current | Notification of Event LLC.28 Message: 'Inv access priority $1 for interface $2' Parameters list: $1: llc28-access-priority $2: llc28-interface access-priority,… | |
| 1.3.6.1.4.1.2007.1.4.103.2.0.29 | NotificationllcNotification29 | current | Notification of Event LLC.29 Message: 'Inv acc $1 for interface $2' Parameters list: $1: llc29-access-priority $2: llc29-interface The access priority is great… | |
| 1.3.6.1.4.1.2007.1.4.103.2.0.30 | NotificationllcNotification30 | current | Notification of Event LLC.30 Message: 'Invalid hardware type $1 for interface $2' Parameters list: $1: llc30-hardware-type $2: llc30-interface An LLC config re… | |
| 1.3.6.1.4.1.2007.1.4.103.2.0.31 | NotificationllcNotification31 | current | Notification of Event LLC.31 Message: 'Invalid interface $1 in config' Parameters list: $1: llc31-interface-number An LLC config record exists for an interface… | |
| 1.3.6.1.4.1.2007.1.4.103.2.0.32 | NotificationllcNotification32 | current | Notification of Event LLC.32 Message: 'Sent $1, $2->$3, $4 saps $5->$6, interface $7' Parameters list: $1: llc32-frame-type $2: llc32-src-mac $3: llc32-dst-mac… | |
| 1.3.6.1.4.1.2007.1.4.103.2.0.33 | NotificationllcNotification33 | current | Notification of Event LLC.33 Message: 'frm to LLC, frm $1, $2->$3, $4 saps $5->$6, interface $7' Parameters list: $1: llc33-frame-type $2: llc33-src-mac $3: ll… |