MIB Viewer

TELDAT-TRAP-LLC-MIB

178 objects
This Module Information Base file is defined for managing received SNMP notifications generated by the LLC event subsystem.
Imported Objects
SNMPv2-SMIInteger32 IpAddress MODULE-IDENTITY NOTIFICATION-TYPE OBJECT-IDENTITY OBJECT-TYPE
SNMPv2-TCDisplayString
TELDAT-MIBtelEventTraps
OIDNameAccessStatusDescription
1.3.6.1.4.1.2007.1.4.103IdentityllcTrapsMIBThis Module Information Base file is defined for managing received SNMP notifications generated by the LLC event subsystem.
1.3.6.1.4.1.2007.1.4.103.1NodellcEventsGroup
1.3.6.1.4.1.2007.1.4.103.1.1IdentityllcEventObjects1currentEvent LLC.1 LLC is sending a frame. Possible frame types are: SABME-C0 or SABME-C1 (Set Asynchronous Balanced Mode Extended), DM-R0 or DM-R1 (Disconnected Mode…
1.3.6.1.4.1.2007.1.4.103.1.1.1Scalarllc1-frame-typeaccessible-for-notifycurrentParameter 'frame-type' in event LLC.1
1.3.6.1.4.1.2007.1.4.103.1.1.2Scalarllc1-src-macaccessible-for-notifycurrentParameter 'src-mac' in event LLC.1
1.3.6.1.4.1.2007.1.4.103.1.1.3Scalarllc1-dst-macaccessible-for-notifycurrentParameter 'dst-mac' in event LLC.1
1.3.6.1.4.1.2007.1.4.103.1.1.4Scalarllc1-rifaccessible-for-notifycurrentParameter 'rif' in event LLC.1
1.3.6.1.4.1.2007.1.4.103.1.1.5Scalarllc1-src-sapaccessible-for-notifycurrentParameter 'src-sap' in event LLC.1
1.3.6.1.4.1.2007.1.4.103.1.1.6Scalarllc1-dst-sapaccessible-for-notifycurrentParameter 'dst-sap' in event LLC.1
1.3.6.1.4.1.2007.1.4.103.1.1.7Scalarllc1-interfaceaccessible-for-notifycurrentParameter 'interface' in event LLC.1
1.3.6.1.4.1.2007.1.4.103.1.2IdentityllcEventObjects2currentEvent LLC.2 An event occurred on an llc2 connection. The LLC2 FSM (Finite State Machine) has been called to process the event. The LLC2 connection is uniquely …
1.3.6.1.4.1.2007.1.4.103.1.2.1Scalarllc2-llc-eventaccessible-for-notifycurrentParameter 'llc-event' in event LLC.2
1.3.6.1.4.1.2007.1.4.103.1.2.2Scalarllc2-llc-stateaccessible-for-notifycurrentParameter 'llc-state' in event LLC.2
1.3.6.1.4.1.2007.1.4.103.1.2.3Scalarllc2-llc2-connectionaccessible-for-notifycurrentParameter 'llc2-connection' in event LLC.2
1.3.6.1.4.1.2007.1.4.103.1.2.4Scalarllc2-llc2-sapaccessible-for-notifycurrentParameter 'llc2-sap' in event LLC.2
1.3.6.1.4.1.2007.1.4.103.1.2.5Scalarllc2-interfaceaccessible-for-notifycurrentParameter 'interface' in event LLC.2
1.3.6.1.4.1.2007.1.4.103.1.3IdentityllcEventObjects3currentEvent LLC.3 There is LLC2 state change. The possible states are: DISCONNECTED (initial state), LINK-OPENING (link establishment in progress), DISCONNECTING (DI…
1.3.6.1.4.1.2007.1.4.103.1.3.1Scalarllc3-llc-old-stateaccessible-for-notifycurrentParameter 'llc-old-state' in event LLC.3
1.3.6.1.4.1.2007.1.4.103.1.3.2Scalarllc3-llc-new-stateaccessible-for-notifycurrentParameter 'llc-new-state' in event LLC.3
1.3.6.1.4.1.2007.1.4.103.1.3.3Scalarllc3-llc2-connectionaccessible-for-notifycurrentParameter 'llc2-connection' in event LLC.3
1.3.6.1.4.1.2007.1.4.103.1.3.4Scalarllc3-llc2-sapaccessible-for-notifycurrentParameter 'llc2-sap' in event LLC.3
1.3.6.1.4.1.2007.1.4.103.1.3.5Scalarllc3-interfaceaccessible-for-notifycurrentParameter 'interface' in event LLC.3
1.3.6.1.4.1.2007.1.4.103.1.4IdentityllcEventObjects4currentEvent LLC.4 LLC2 event upcall is occuring. Some of the arguments on the upcall are shown. User Cookie is meaningful to the router software running over the LLC…
1.3.6.1.4.1.2007.1.4.103.1.4.1Scalarllc4-user-eventaccessible-for-notifycurrentParameter 'user-event' in event LLC.4
1.3.6.1.4.1.2007.1.4.103.1.4.2Scalarllc4-user-valueaccessible-for-notifycurrentParameter 'user-value' in event LLC.4
1.3.6.1.4.1.2007.1.4.103.1.4.3Scalarllc4-event-reasonaccessible-for-notifycurrentParameter 'event-reason' in event LLC.4
1.3.6.1.4.1.2007.1.4.103.1.4.4Scalarllc4-llc2-connectionaccessible-for-notifycurrentParameter 'llc2-connection' in event LLC.4
1.3.6.1.4.1.2007.1.4.103.1.4.5Scalarllc4-llc2-sapaccessible-for-notifycurrentParameter 'llc2-sap' in event LLC.4
1.3.6.1.4.1.2007.1.4.103.1.4.6Scalarllc4-interfaceaccessible-for-notifycurrentParameter 'interface' in event LLC.4
1.3.6.1.4.1.2007.1.4.103.1.5IdentityllcEventObjects5currentEvent LLC.5 A sap-releated LLC user-primitive was called. The possible SAP primitives are: OPEN-SAP, CLOSE-SAP, CLOSE-SAP-FORCED, MODIFY-SAP, OPEN-STATION, and…
1.3.6.1.4.1.2007.1.4.103.1.5.1Scalarllc5-user-primitiveaccessible-for-notifycurrentParameter 'user-primitive' in event LLC.5
1.3.6.1.4.1.2007.1.4.103.1.5.2Scalarllc5-SAP-valueaccessible-for-notifycurrentParameter 'SAP-value' in event LLC.5
1.3.6.1.4.1.2007.1.4.103.1.5.3Scalarllc5-interfaceaccessible-for-notifycurrentParameter 'interface' in event LLC.5
1.3.6.1.4.1.2007.1.4.103.1.6IdentityllcEventObjects6currentEvent LLC.6 A llc2 connection non-data user-primitive was called. The possible primitives are: CLOSE-STATION, CLOSE-STATION-FORCED, CONNECT-REQUEST, CONNECT-RE…
1.3.6.1.4.1.2007.1.4.103.1.6.1Scalarllc6-user-primitiveaccessible-for-notifycurrentParameter 'user-primitive' in event LLC.6
1.3.6.1.4.1.2007.1.4.103.1.6.2Scalarllc6-llc2-connectionaccessible-for-notifycurrentParameter 'llc2-connection' in event LLC.6
1.3.6.1.4.1.2007.1.4.103.1.6.3Scalarllc6-llc2-sapaccessible-for-notifycurrentParameter 'llc2-sap' in event LLC.6
1.3.6.1.4.1.2007.1.4.103.1.6.4Scalarllc6-interfaceaccessible-for-notifycurrentParameter 'interface' in event LLC.6
1.3.6.1.4.1.2007.1.4.103.1.7IdentityllcEventObjects7currentEvent LLC.7 A DATA-REQUEST data primitive was called. DATA-REQUEST passes the data in buffer memory.
1.3.6.1.4.1.2007.1.4.103.1.7.1Scalarllc7-llc2-connectionaccessible-for-notifycurrentParameter 'llc2-connection' in event LLC.7
1.3.6.1.4.1.2007.1.4.103.1.7.2Scalarllc7-llc2-sapaccessible-for-notifycurrentParameter 'llc2-sap' in event LLC.7
1.3.6.1.4.1.2007.1.4.103.1.7.3Scalarllc7-interfaceaccessible-for-notifycurrentParameter 'interface' in event LLC.7
1.3.6.1.4.1.2007.1.4.103.1.8IdentityllcEventObjects8currentEvent LLC.8 A DATA-LOCAL data primitive was called. DATA-LOCAL passes the data in data memory.
1.3.6.1.4.1.2007.1.4.103.1.8.1Scalarllc8-llc2-connectionaccessible-for-notifycurrentParameter 'llc2-connection' in event LLC.8
1.3.6.1.4.1.2007.1.4.103.1.8.2Scalarllc8-llc2-sapaccessible-for-notifycurrentParameter 'llc2-sap' in event LLC.8
1.3.6.1.4.1.2007.1.4.103.1.8.3Scalarllc8-interfaceaccessible-for-notifycurrentParameter 'interface' in event LLC.8
1.3.6.1.4.1.2007.1.4.103.1.9IdentityllcEventObjects9currentEvent LLC.9 A UNITDATA llc1 data primitive was called.
1.3.6.1.4.1.2007.1.4.103.1.9.1Scalarllc9-SAP-valueaccessible-for-notifycurrentParameter 'SAP-value' in event LLC.9
1.3.6.1.4.1.2007.1.4.103.1.9.2Scalarllc9-interfaceaccessible-for-notifycurrentParameter 'interface' in event LLC.9
1.3.6.1.4.1.2007.1.4.103.1.10IdentityllcEventObjects10currentEvent LLC.10 The oubound queue has grown grossly large. The llc2 connection is being automatically terminated.
1.3.6.1.4.1.2007.1.4.103.1.10.1Scalarllc10-llc2-connectionaccessible-for-notifycurrentParameter 'llc2-connection' in event LLC.10
1.3.6.1.4.1.2007.1.4.103.1.10.2Scalarllc10-llc2-sapaccessible-for-notifycurrentParameter 'llc2-sap' in event LLC.10
1.3.6.1.4.1.2007.1.4.103.1.10.3Scalarllc10-interfaceaccessible-for-notifycurrentParameter 'interface' in event LLC.10
1.3.6.1.4.1.2007.1.4.103.1.11IdentityllcEventObjects11currentEvent LLC.11 No buffer available to duplicate I-frame.
1.3.6.1.4.1.2007.1.4.103.1.11.1Scalarllc11-llc2-connectionaccessible-for-notifycurrentParameter 'llc2-connection' in event LLC.11
1.3.6.1.4.1.2007.1.4.103.1.11.2Scalarllc11-llc2-sapaccessible-for-notifycurrentParameter 'llc2-sap' in event LLC.11
1.3.6.1.4.1.2007.1.4.103.1.11.3Scalarllc11-interfaceaccessible-for-notifycurrentParameter 'interface' in event LLC.11
1.3.6.1.4.1.2007.1.4.103.1.12IdentityllcEventObjects12currentEvent LLC.12 No memory to duplicate I-frame.
1.3.6.1.4.1.2007.1.4.103.1.12.1Scalarllc12-llc2-connectionaccessible-for-notifycurrentParameter 'llc2-connection' in event LLC.12
1.3.6.1.4.1.2007.1.4.103.1.12.2Scalarllc12-llc2-sapaccessible-for-notifycurrentParameter 'llc2-sap' in event LLC.12
1.3.6.1.4.1.2007.1.4.103.1.12.3Scalarllc12-interfaceaccessible-for-notifycurrentParameter 'interface' in event LLC.12
1.3.6.1.4.1.2007.1.4.103.1.13IdentityllcEventObjects13currentEvent LLC.13 A buffer could not be obtained to to build an LLC Supervisory or Unnumbered frame. No loss of data integrity has occurred yet, but unless buffers …
1.3.6.1.4.1.2007.1.4.103.1.13.1Scalarllc13-llc2-connectionaccessible-for-notifycurrentParameter 'llc2-connection' in event LLC.13
1.3.6.1.4.1.2007.1.4.103.1.13.2Scalarllc13-llc2-sapaccessible-for-notifycurrentParameter 'llc2-sap' in event LLC.13
1.3.6.1.4.1.2007.1.4.103.1.13.3Scalarllc13-interfaceaccessible-for-notifycurrentParameter 'interface' in event LLC.13
1.3.6.1.4.1.2007.1.4.103.1.14IdentityllcEventObjects14currentEvent LLC.14 The frame type the LLC is trying to build is invalid.
1.3.6.1.4.1.2007.1.4.103.1.14.1Scalarllc14-llc2-connectionaccessible-for-notifycurrentParameter 'llc2-connection' in event LLC.14
1.3.6.1.4.1.2007.1.4.103.1.14.2Scalarllc14-llc2-sapaccessible-for-notifycurrentParameter 'llc2-sap' in event LLC.14
1.3.6.1.4.1.2007.1.4.103.1.14.3Scalarllc14-interfaceaccessible-for-notifycurrentParameter 'interface' in event LLC.14
1.3.6.1.4.1.2007.1.4.103.1.15IdentityllcEventObjects15currentEvent LLC.15 The LLC2 Finite State Machine (FSM) was called with an event that was out of range.
1.3.6.1.4.1.2007.1.4.103.1.15.1Scalarllc15-event-code-numberaccessible-for-notifycurrentParameter 'event-code-number' in event LLC.15
1.3.6.1.4.1.2007.1.4.103.1.16IdentityllcEventObjects16currentEvent LLC.16 An OPEN SAP operation was tried on a network type that LLC does not support. Network types Token-Ring, Ethernet, and FDDI are supported.
1.3.6.1.4.1.2007.1.4.103.1.16.1Scalarllc16-network-typeaccessible-for-notifycurrentParameter 'network-type' in event LLC.16
1.3.6.1.4.1.2007.1.4.103.1.16.2Scalarllc16-interfaceaccessible-for-notifycurrentParameter 'interface' in event LLC.16
1.3.6.1.4.1.2007.1.4.103.1.17IdentityllcEventObjects17currentEvent LLC.17 A OPEN SAP operation was tried on a sap that has already been opened.
1.3.6.1.4.1.2007.1.4.103.1.17.1Scalarllc17-SAP-valueaccessible-for-notifycurrentParameter 'SAP-value' in event LLC.17
1.3.6.1.4.1.2007.1.4.103.1.17.2Scalarllc17-interfaceaccessible-for-notifycurrentParameter 'interface' in event LLC.17
1.3.6.1.4.1.2007.1.4.103.1.18IdentityllcEventObjects18currentEvent LLC.18 Unable to allocate memory for SAP control block.
1.3.6.1.4.1.2007.1.4.103.1.18.1Scalarllc18-interfaceaccessible-for-notifycurrentParameter 'interface' in event LLC.18
1.3.6.1.4.1.2007.1.4.103.1.19IdentityllcEventObjects19currentEvent LLC.19 Unable to allocate memory for station control block.
1.3.6.1.4.1.2007.1.4.103.1.19.1Scalarllc19-interfaceaccessible-for-notifycurrentParameter 'interface' in event LLC.19
1.3.6.1.4.1.2007.1.4.103.1.20IdentityllcEventObjects20currentEvent LLC.20 UI frame refused by the local application within the router.
1.3.6.1.4.1.2007.1.4.103.1.20.1Scalarllc20-llc2-connectionaccessible-for-notifycurrentParameter 'llc2-connection' in event LLC.20
1.3.6.1.4.1.2007.1.4.103.1.20.2Scalarllc20-llc2-sapaccessible-for-notifycurrentParameter 'llc2-sap' in event LLC.20
1.3.6.1.4.1.2007.1.4.103.1.20.3Scalarllc20-interfaceaccessible-for-notifycurrentParameter 'interface' in event LLC.20
1.3.6.1.4.1.2007.1.4.103.1.21IdentityllcEventObjects21currentEvent LLC.21 TEST frame refused by the local application within the router. The frame is passed on to the bridge code, etc.
1.3.6.1.4.1.2007.1.4.103.1.21.1Scalarllc21-llc2-connectionaccessible-for-notifycurrentParameter 'llc2-connection' in event LLC.21
1.3.6.1.4.1.2007.1.4.103.1.21.2Scalarllc21-llc2-sapaccessible-for-notifycurrentParameter 'llc2-sap' in event LLC.21
1.3.6.1.4.1.2007.1.4.103.1.21.3Scalarllc21-interfaceaccessible-for-notifycurrentParameter 'interface' in event LLC.21
1.3.6.1.4.1.2007.1.4.103.1.22IdentityllcEventObjects22currentEvent LLC.22 XID frame refused by the local application within the router. The frame is passed on to the bridge code, etc.
1.3.6.1.4.1.2007.1.4.103.1.22.1Scalarllc22-llc2-connectionaccessible-for-notifycurrentParameter 'llc2-connection' in event LLC.22
1.3.6.1.4.1.2007.1.4.103.1.22.2Scalarllc22-llc2-sapaccessible-for-notifycurrentParameter 'llc2-sap' in event LLC.22
1.3.6.1.4.1.2007.1.4.103.1.22.3Scalarllc22-interfaceaccessible-for-notifycurrentParameter 'interface' in event LLC.22
1.3.6.1.4.1.2007.1.4.103.1.23IdentityllcEventObjects23currentEvent LLC.23 LLC makes an upcall providing the LLC with a unitdata frame. The possible unitdata frames are: TEST-C0 or TEST-C1 or TEST-R0 or TEST-R1 (TEST fram…
1.3.6.1.4.1.2007.1.4.103.1.23.1Scalarllc23-frame-typeaccessible-for-notifycurrentParameter 'frame-type' in event LLC.23
1.3.6.1.4.1.2007.1.4.103.1.23.2Scalarllc23-src-macaccessible-for-notifycurrentParameter 'src-mac' in event LLC.23
1.3.6.1.4.1.2007.1.4.103.1.23.3Scalarllc23-dst-macaccessible-for-notifycurrentParameter 'dst-mac' in event LLC.23
1.3.6.1.4.1.2007.1.4.103.1.23.4Scalarllc23-rifaccessible-for-notifycurrentParameter 'rif' in event LLC.23
1.3.6.1.4.1.2007.1.4.103.1.23.5Scalarllc23-src-sapaccessible-for-notifycurrentParameter 'src-sap' in event LLC.23
1.3.6.1.4.1.2007.1.4.103.1.23.6Scalarllc23-dst-sapaccessible-for-notifycurrentParameter 'dst-sap' in event LLC.23
1.3.6.1.4.1.2007.1.4.103.1.23.7Scalarllc23-interfaceaccessible-for-notifycurrentParameter 'interface' in event LLC.23
1.3.6.1.4.1.2007.1.4.103.1.24IdentityllcEventObjects24currentEvent LLC.24 The sending of an LLC2 related outbound frame failed. The reason-code is the internal error code for the failure.
1.3.6.1.4.1.2007.1.4.103.1.24.1Scalarllc24-reason-codeaccessible-for-notifycurrentParameter 'reason-code' in event LLC.24
1.3.6.1.4.1.2007.1.4.103.1.24.2Scalarllc24-llc2-connectionaccessible-for-notifycurrentParameter 'llc2-connection' in event LLC.24
1.3.6.1.4.1.2007.1.4.103.1.24.3Scalarllc24-llc2-sapaccessible-for-notifycurrentParameter 'llc2-sap' in event LLC.24
1.3.6.1.4.1.2007.1.4.103.1.24.4Scalarllc24-interface-nameaccessible-for-notifycurrentParameter 'interface-name' in event LLC.24
1.3.6.1.4.1.2007.1.4.103.1.25IdentityllcEventObjects25currentEvent LLC.25 The sending of the user's UNITDATA or an LLC-generated XID or TEST response outbound frame failed. The possible frame test are: TEST-C0 or TEST-C1…
1.3.6.1.4.1.2007.1.4.103.1.25.1Scalarllc25-frame-typeaccessible-for-notifycurrentParameter 'frame-type' in event LLC.25
1.3.6.1.4.1.2007.1.4.103.1.25.2Scalarllc25-reason-codeaccessible-for-notifycurrentParameter 'reason-code' in event LLC.25
1.3.6.1.4.1.2007.1.4.103.1.25.3Scalarllc25-llc2-connectionaccessible-for-notifycurrentParameter 'llc2-connection' in event LLC.25
1.3.6.1.4.1.2007.1.4.103.1.25.4Scalarllc25-llc2-sapaccessible-for-notifycurrentParameter 'llc2-sap' in event LLC.25
1.3.6.1.4.1.2007.1.4.103.1.25.5Scalarllc25-interfaceaccessible-for-notifycurrentParameter 'interface' in event LLC.25
1.3.6.1.4.1.2007.1.4.103.1.26IdentityllcEventObjects26currentEvent LLC.26 Unable to allocate memory for an LLC-CONF-BLOCK at initialization time. LLC configuration defaults are used.
1.3.6.1.4.1.2007.1.4.103.1.26.1Scalarllc26-interfaceaccessible-for-notifycurrentParameter 'interface' in event LLC.26
1.3.6.1.4.1.2007.1.4.103.1.27IdentityllcEventObjects27currentEvent LLC.27 LLC Configuration record read for this network. This only occurs at initialization time. The values in the LLC configuration record are used as de…
1.3.6.1.4.1.2007.1.4.103.1.27.1Scalarllc27-interfaceaccessible-for-notifycurrentParameter 'interface' in event LLC.27
1.3.6.1.4.1.2007.1.4.103.1.28IdentityllcEventObjects28currentEvent LLC.28 access-priority, on an interface that is not a token ring must be zero because it is not used.
1.3.6.1.4.1.2007.1.4.103.1.28.1Scalarllc28-access-priorityaccessible-for-notifycurrentParameter 'access-priority' in event LLC.28
1.3.6.1.4.1.2007.1.4.103.1.28.2Scalarllc28-interfaceaccessible-for-notifycurrentParameter 'interface' in event LLC.28
1.3.6.1.4.1.2007.1.4.103.1.29IdentityllcEventObjects29currentEvent LLC.29 The access priority is greater than 7. A default of 0 is used.
1.3.6.1.4.1.2007.1.4.103.1.29.1Scalarllc29-access-priorityaccessible-for-notifycurrentParameter 'access-priority' in event LLC.29
1.3.6.1.4.1.2007.1.4.103.1.29.2Scalarllc29-interfaceaccessible-for-notifycurrentParameter 'interface' in event LLC.29
1.3.6.1.4.1.2007.1.4.103.1.30IdentityllcEventObjects30currentEvent LLC.30 An LLC config record exists for an interface that does not have a LAN hardware type.
1.3.6.1.4.1.2007.1.4.103.1.30.1Scalarllc30-hardware-typeaccessible-for-notifycurrentParameter 'hardware-type' in event LLC.30
1.3.6.1.4.1.2007.1.4.103.1.30.2Scalarllc30-interfaceaccessible-for-notifycurrentParameter 'interface' in event LLC.30
1.3.6.1.4.1.2007.1.4.103.1.31IdentityllcEventObjects31currentEvent LLC.31 An LLC config record exists for an interface that does not exist.
1.3.6.1.4.1.2007.1.4.103.1.31.1Scalarllc31-interface-numberaccessible-for-notifycurrentParameter 'interface-number' in event LLC.31
1.3.6.1.4.1.2007.1.4.103.1.32IdentityllcEventObjects32currentEvent LLC.32 LLC user is sending a frame, or LLC itself is sending a TEST or XID response frame. The possible frame types are: TEST-C0 or TEST-C1 or TEST-R0 or…
1.3.6.1.4.1.2007.1.4.103.1.32.1Scalarllc32-frame-typeaccessible-for-notifycurrentParameter 'frame-type' in event LLC.32
1.3.6.1.4.1.2007.1.4.103.1.32.2Scalarllc32-src-macaccessible-for-notifycurrentParameter 'src-mac' in event LLC.32
1.3.6.1.4.1.2007.1.4.103.1.32.3Scalarllc32-dst-macaccessible-for-notifycurrentParameter 'dst-mac' in event LLC.32
1.3.6.1.4.1.2007.1.4.103.1.32.4Scalarllc32-rifaccessible-for-notifycurrentParameter 'rif' in event LLC.32
1.3.6.1.4.1.2007.1.4.103.1.32.5Scalarllc32-src-sapaccessible-for-notifycurrentParameter 'src-sap' in event LLC.32
1.3.6.1.4.1.2007.1.4.103.1.32.6Scalarllc32-dst-sapaccessible-for-notifycurrentParameter 'dst-sap' in event LLC.32
1.3.6.1.4.1.2007.1.4.103.1.32.7Scalarllc32-interfaceaccessible-for-notifycurrentParameter 'interface' in event LLC.32
1.3.6.1.4.1.2007.1.4.103.1.33IdentityllcEventObjects33currentEvent LLC.33 LLC subsystem itself is responding to a TEST or XID frame. The possible frame types are: TEST-C0 or TEST-C1 (TEST frame), and XID-C0 or XID-C1 (Ex…
1.3.6.1.4.1.2007.1.4.103.1.33.1Scalarllc33-frame-typeaccessible-for-notifycurrentParameter 'frame-type' in event LLC.33
1.3.6.1.4.1.2007.1.4.103.1.33.2Scalarllc33-src-macaccessible-for-notifycurrentParameter 'src-mac' in event LLC.33
1.3.6.1.4.1.2007.1.4.103.1.33.3Scalarllc33-dst-macaccessible-for-notifycurrentParameter 'dst-mac' in event LLC.33
1.3.6.1.4.1.2007.1.4.103.1.33.4Scalarllc33-rifaccessible-for-notifycurrentParameter 'rif' in event LLC.33
1.3.6.1.4.1.2007.1.4.103.1.33.5Scalarllc33-src-sapaccessible-for-notifycurrentParameter 'src-sap' in event LLC.33
1.3.6.1.4.1.2007.1.4.103.1.33.6Scalarllc33-dst-sapaccessible-for-notifycurrentParameter 'dst-sap' in event LLC.33
1.3.6.1.4.1.2007.1.4.103.1.33.7Scalarllc33-interfaceaccessible-for-notifycurrentParameter 'interface' in event LLC.33
1.3.6.1.4.1.2007.1.4.103.2NodellcNotifications
1.3.6.1.4.1.2007.1.4.103.2.0NodellcNotificationsPrefix
1.3.6.1.4.1.2007.1.4.103.2.0.1NotificationllcNotification1currentNotification of Event LLC.1 Message: 'Sent $1, $2->$3, $4 saps $5->$6, interface $7' Parameters list: $1: llc1-frame-type $2: llc1-src-mac $3: llc1-dst-mac $4:…
1.3.6.1.4.1.2007.1.4.103.2.0.2NotificationllcNotification2currentNotification of Event LLC.2 Message: 'event=$1 in state=$2, $3->$4, saps $5->$6, interface $7' Parameters list: $1: llc2-llc-event $2: llc2-llc-state $3: llc2-…
1.3.6.1.4.1.2007.1.4.103.2.0.3NotificationllcNotification3currentNotification of Event LLC.3 Message: '$1 to $2, $3->$4, saps $5->$6, interface $7' Parameters list: $1: llc3-llc-old-state $2: llc3-llc-new-state $3: llc3-llc2…
1.3.6.1.4.1.2007.1.4.103.2.0.4NotificationllcNotification4currentNotification of Event LLC.4 Message: 'Upcall user event $1 args $2/$3 on $4->$5, saps $6->$7, interface $8' Parameters list: $1: llc4-user-event $2: llc4-user-…
1.3.6.1.4.1.2007.1.4.103.2.0.5NotificationllcNotification5currentNotification of Event LLC.5 Message: 'user primitive $1 sap $2 on interface $3' Parameters list: $1: llc5-user-primitive $2: llc5-SAP-value $3: llc5-interface …
1.3.6.1.4.1.2007.1.4.103.2.0.6NotificationllcNotification6currentNotification of Event LLC.6 Message: 'primitive $1, $2->$3, saps $4->$5, interface $6' Parameters list: $1: llc6-user-primitive $2: llc6-llc2-connection $3: ll…
1.3.6.1.4.1.2007.1.4.103.2.0.7NotificationllcNotification7currentNotification of Event LLC.7 Message: 'data primitive, $1->$2, saps $3->$4, interface $5' Parameters list: $1: llc7-llc2-connection $2: llc7-llc2-connection $3:…
1.3.6.1.4.1.2007.1.4.103.2.0.8NotificationllcNotification8currentNotification of Event LLC.8 Message: 'data primitive, $1->$2, saps $3->$4, interface $5' Parameters list: $1: llc8-llc2-connection $2: llc8-llc2-connection $3:…
1.3.6.1.4.1.2007.1.4.103.2.0.9NotificationllcNotification9currentNotification of Event LLC.9 Message: 'unitdata primitive, sap $1 interface $2' Parameters list: $1: llc9-SAP-value $2: llc9-interface A UNITDATA llc1 data prim…
1.3.6.1.4.1.2007.1.4.103.2.0.10NotificationllcNotification10currentNotification of Event LLC.10 Message: 'outbound queue too big, $1->$2, saps $3->$4, interface $5' Parameters list: $1: llc10-llc2-connection $2: llc10-llc2-con…
1.3.6.1.4.1.2007.1.4.103.2.0.11NotificationllcNotification11currentNotification of Event LLC.11 Message: 'No buffer available to duplicate I-frame, $1->$2, saps $3->$4, interface $5' Parameters list: $1: llc11-llc2-connection …
1.3.6.1.4.1.2007.1.4.103.2.0.12NotificationllcNotification12currentNotification of Event LLC.12 Message: 'No memory available to duplicate I-frame, $1->$2, saps $3->$4, interface $5' Parameters list: $1: llc12-llc2-connection …
1.3.6.1.4.1.2007.1.4.103.2.0.13NotificationllcNotification13currentNotification of Event LLC.13 Message: 'No buffer for LLC frame, $1->$2, saps $3->$4, interface $5' Parameters list: $1: llc13-llc2-connection $2: llc13-llc2-co…
1.3.6.1.4.1.2007.1.4.103.2.0.14NotificationllcNotification14currentNotification of Event LLC.14 Message: 'frame type invalid, $1->$2, saps $3->$4, interface $5' Parameters list: $1: llc14-llc2-connection $2: llc14-llc2-connect…
1.3.6.1.4.1.2007.1.4.103.2.0.15NotificationllcNotification15currentNotification of Event LLC.15 Message: 'Invalid LLC2 FSM event $1' Parameters list: $1: llc15-event-code-number The LLC2 Finite State Machine (FSM) was called w…
1.3.6.1.4.1.2007.1.4.103.2.0.16NotificationllcNotification16currentNotification of Event LLC.16 Message: 'invalid network type $1 on interface $2' Parameters list: $1: llc16-network-type $2: llc16-interface An OPEN SAP operati…
1.3.6.1.4.1.2007.1.4.103.2.0.17NotificationllcNotification17currentNotification of Event LLC.17 Message: 'duplicate sap $1 on interface $2' Parameters list: $1: llc17-SAP-value $2: llc17-interface A OPEN SAP operation was trie…
1.3.6.1.4.1.2007.1.4.103.2.0.18NotificationllcNotification18currentNotification of Event LLC.18 Message: 'No memory for SAP control block on interface $1' Parameters list: $1: llc18-interface Unable to allocate memory for SAP …
1.3.6.1.4.1.2007.1.4.103.2.0.19NotificationllcNotification19currentNotification of Event LLC.19 Message: 'No memory for station control block on interface $1' Parameters list: $1: llc19-interface Unable to allocate memory for …
1.3.6.1.4.1.2007.1.4.103.2.0.20NotificationllcNotification20currentNotification of Event LLC.20 Message: 'UI frame dropped, $1->$2, saps $3->$4, interface $5' Parameters list: $1: llc20-llc2-connection $2: llc20-llc2-connectio…
1.3.6.1.4.1.2007.1.4.103.2.0.21NotificationllcNotification21currentNotification of Event LLC.21 Message: 'TEST frame refused, $1->$2, saps $3->$4, interface $5' Parameters list: $1: llc21-llc2-connection $2: llc21-llc2-connect…
1.3.6.1.4.1.2007.1.4.103.2.0.22NotificationllcNotification22currentNotification of Event LLC.22 Message: 'XID frame refused, $1->$2, saps $3->$4, interface $5' Parameters list: $1: llc22-llc2-connection $2: llc22-llc2-connecti…
1.3.6.1.4.1.2007.1.4.103.2.0.23NotificationllcNotification23currentNotification of Event LLC.23 Message: 'Upcall frame $1, $2->$3, $4 saps $5->$6, interface $7' Parameters list: $1: llc23-frame-type $2: llc23-src-mac $3: llc23…
1.3.6.1.4.1.2007.1.4.103.2.0.24NotificationllcNotification24currentNotification of Event LLC.24 Message: 'llc2 outbound frame dropped, reason $1, $2->$3, saps $4->$5, interface $6' Parameters list: $1: llc24-reason-code $2: ll…
1.3.6.1.4.1.2007.1.4.103.2.0.25NotificationllcNotification25currentNotification of Event LLC.25 Message: '$1 outbound frame dropped, reason $2, $3->$4, saps $5->$6, interface $7' Parameters list: $1: llc25-frame-type $2: llc25…
1.3.6.1.4.1.2007.1.4.103.2.0.26NotificationllcNotification26currentNotification of Event LLC.26 Message: 'No memory for LLC CONF BLOCK on interface $1' Parameters list: $1: llc26-interface Unable to allocate memory for an LLC-…
1.3.6.1.4.1.2007.1.4.103.2.0.27NotificationllcNotification27currentNotification of Event LLC.27 Message: 'Read LLC Configuration record for interface $1' Parameters list: $1: llc27-interface LLC Configuration record read for t…
1.3.6.1.4.1.2007.1.4.103.2.0.28NotificationllcNotification28currentNotification of Event LLC.28 Message: 'Inv access priority $1 for interface $2' Parameters list: $1: llc28-access-priority $2: llc28-interface access-priority,…
1.3.6.1.4.1.2007.1.4.103.2.0.29NotificationllcNotification29currentNotification of Event LLC.29 Message: 'Inv acc $1 for interface $2' Parameters list: $1: llc29-access-priority $2: llc29-interface The access priority is great…
1.3.6.1.4.1.2007.1.4.103.2.0.30NotificationllcNotification30currentNotification of Event LLC.30 Message: 'Invalid hardware type $1 for interface $2' Parameters list: $1: llc30-hardware-type $2: llc30-interface An LLC config re…
1.3.6.1.4.1.2007.1.4.103.2.0.31NotificationllcNotification31currentNotification of Event LLC.31 Message: 'Invalid interface $1 in config' Parameters list: $1: llc31-interface-number An LLC config record exists for an interface…
1.3.6.1.4.1.2007.1.4.103.2.0.32NotificationllcNotification32currentNotification of Event LLC.32 Message: 'Sent $1, $2->$3, $4 saps $5->$6, interface $7' Parameters list: $1: llc32-frame-type $2: llc32-src-mac $3: llc32-dst-mac…
1.3.6.1.4.1.2007.1.4.103.2.0.33NotificationllcNotification33currentNotification of Event LLC.33 Message: 'frm to LLC, frm $1, $2->$3, $4 saps $5->$6, interface $7' Parameters list: $1: llc33-frame-type $2: llc33-src-mac $3: ll…