TELDAT-TRAP-SL-MIB
148 objects
This Module Information Base file is defined for managing received SNMP notifications generated by the SL event subsystem.
Imported Objects
| SNMPv2-SMI | Integer32 IpAddress MODULE-IDENTITY NOTIFICATION-TYPE OBJECT-IDENTITY OBJECT-TYPE |
| SNMPv2-TC | DisplayString |
| TELDAT-MIB | telEventTraps |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.2007.1.4.83 | IdentityslTrapsMIB | This Module Information Base file is defined for managing received SNMP notifications generated by the SL event subsystem. | ||
| 1.3.6.1.4.1.2007.1.4.83.1 | NodeslEventsGroup | |||
| 1.3.6.1.4.1.2007.1.4.83.1.1 | IdentityslEventObjects1 | current | Event SL.1 A packet buffer was not available when the interface self-test needed one. | |
| 1.3.6.1.4.1.2007.1.4.83.1.1.1 | Scalarsl1-interface | accessible-for-notify | current | Parameter 'interface' in event SL.1 |
| 1.3.6.1.4.1.2007.1.4.83.1.2 | IdentityslEventObjects2 | current | Event SL.2 During the self-test, the interface card detected that certain signals from modem necessary to indicate that it is present and ready to operate were… | |
| 1.3.6.1.4.1.2007.1.4.83.1.2.1 | Scalarsl2-interface | accessible-for-notify | current | Parameter 'interface' in event SL.2 |
| 1.3.6.1.4.1.2007.1.4.83.1.3 | IdentityslEventObjects3 | current | Event SL.3 During self-test, an Echo Acknowledgement was not received from the other end of the line within the timeout period. The network fails self-test. | |
| 1.3.6.1.4.1.2007.1.4.83.1.3.1 | Scalarsl3-interface | accessible-for-notify | current | Parameter 'interface' in event SL.3 |
| 1.3.6.1.4.1.2007.1.4.83.1.4 | IdentityslEventObjects4 | current | Event SL.4 A bad length field or truncated packet was detected in a DECnet packet on the serial line. | |
| 1.3.6.1.4.1.2007.1.4.83.1.4.1 | Scalarsl4-actual-length | accessible-for-notify | current | Parameter 'actual-length' in event SL.4 |
| 1.3.6.1.4.1.2007.1.4.83.1.4.2 | Scalarsl4-claimed-length | accessible-for-notify | current | Parameter 'claimed-length' in event SL.4 |
| 1.3.6.1.4.1.2007.1.4.83.1.4.3 | Scalarsl4-interface | accessible-for-notify | current | Parameter 'interface' in event SL.4 |
| 1.3.6.1.4.1.2007.1.4.83.1.5 | IdentityslEventObjects5 | current | Event SL.5 A network control packet was received with a packet type which did not match any known opcode. | |
| 1.3.6.1.4.1.2007.1.4.83.1.5.1 | Scalarsl5-opcode | accessible-for-notify | current | Parameter 'opcode' in event SL.5 |
| 1.3.6.1.4.1.2007.1.4.83.1.5.2 | Scalarsl5-interface | accessible-for-notify | current | Parameter 'interface' in event SL.5 |
| 1.3.6.1.4.1.2007.1.4.83.1.6 | IdentityslEventObjects6 | current | Event SL.6 A serial line packet was received with a higher level protocol which did not match any known protocol. | |
| 1.3.6.1.4.1.2007.1.4.83.1.6.1 | Scalarsl6-protocol | accessible-for-notify | current | Parameter 'protocol' in event SL.6 |
| 1.3.6.1.4.1.2007.1.4.83.1.6.2 | Scalarsl6-interface | accessible-for-notify | current | Parameter 'interface' in event SL.6 |
| 1.3.6.1.4.1.2007.1.4.83.1.7 | IdentityslEventObjects7 | current | Event SL.7 Self-test is being started on the serial line. | |
| 1.3.6.1.4.1.2007.1.4.83.1.7.1 | Scalarsl7-interface | accessible-for-notify | current | Parameter 'interface' in event SL.7 |
| 1.3.6.1.4.1.2007.1.4.83.1.8 | IdentityslEventObjects8 | current | Event SL.8 An echo request is being sent on the serial line. | |
| 1.3.6.1.4.1.2007.1.4.83.1.8.1 | Scalarsl8-interface | accessible-for-notify | current | Parameter 'interface' in event SL.8 |
| 1.3.6.1.4.1.2007.1.4.83.1.9 | IdentityslEventObjects9 | current | Event SL.9 A test packet has been received on the serial line. | |
| 1.3.6.1.4.1.2007.1.4.83.1.9.1 | Scalarsl9-interface | accessible-for-notify | current | Parameter 'interface' in event SL.9 |
| 1.3.6.1.4.1.2007.1.4.83.1.10 | IdentityslEventObjects10 | current | Event SL.10 An echo acknowledgement packet has been received on the serial line. | |
| 1.3.6.1.4.1.2007.1.4.83.1.10.1 | Scalarsl10-interface | accessible-for-notify | current | Parameter 'interface' in event SL.10 |
| 1.3.6.1.4.1.2007.1.4.83.1.11 | IdentityslEventObjects11 | current | Event SL.11 An echo acknowledgement packet has been received on the serial line. | |
| 1.3.6.1.4.1.2007.1.4.83.1.11.1 | Scalarsl11-interface | accessible-for-notify | current | Parameter 'interface' in event SL.11 |
| 1.3.6.1.4.1.2007.1.4.83.1.12 | IdentityslEventObjects12 | current | Event SL.12 A test packet used for network maintenence is being sent on the serial line. | |
| 1.3.6.1.4.1.2007.1.4.83.1.12.1 | Scalarsl12-interface | accessible-for-notify | current | Parameter 'interface' in event SL.12 |
| 1.3.6.1.4.1.2007.1.4.83.1.13 | IdentityslEventObjects13 | current | Event SL.13 A Bridged packet is received on this serial line interface even though the Spanning Tree Bridging is not enabled on this interface or STB is disabl… | |
| 1.3.6.1.4.1.2007.1.4.83.1.13.1 | Scalarsl13-interface | accessible-for-notify | current | Parameter 'interface' in event SL.13 |
| 1.3.6.1.4.1.2007.1.4.83.1.14 | IdentityslEventObjects14 | current | Event SL.14 Dual Serial Line Interface board firmware download has completed with the status shown. | |
| 1.3.6.1.4.1.2007.1.4.83.1.14.1 | Scalarsl14-slot-num | accessible-for-notify | current | Parameter 'slot-num' in event SL.14 |
| 1.3.6.1.4.1.2007.1.4.83.1.14.2 | Scalarsl14-ld-code | accessible-for-notify | current | Parameter 'ld-code' in event SL.14 |
| 1.3.6.1.4.1.2007.1.4.83.1.15 | IdentityslEventObjects15 | current | Event SL.15 Dual Serial Line Board Power-On Diagnostics status completed with the code shown. See Power-On Diagnostics manual for encoding. | |
| 1.3.6.1.4.1.2007.1.4.83.1.15.1 | Scalarsl15-slot-num | accessible-for-notify | current | Parameter 'slot-num' in event SL.15 |
| 1.3.6.1.4.1.2007.1.4.83.1.15.2 | Scalarsl15-pud-stat | accessible-for-notify | current | Parameter 'pud-stat' in event SL.15 |
| 1.3.6.1.4.1.2007.1.4.83.1.16 | IdentityslEventObjects16 | current | Event SL.16 Protocol type like Ethertype, DSAPytype or SNAPtype packet filtered. This is due to the user supplied protocol filtering information. (STB). | |
| 1.3.6.1.4.1.2007.1.4.83.1.16.1 | Scalarsl16-protocol-type | accessible-for-notify | current | Parameter 'protocol-type' in event SL.16 |
| 1.3.6.1.4.1.2007.1.4.83.1.16.2 | Scalarsl16-protocol | accessible-for-notify | current | Parameter 'protocol' in event SL.16 |
| 1.3.6.1.4.1.2007.1.4.83.1.16.3 | Scalarsl16-interface | accessible-for-notify | current | Parameter 'interface' in event SL.16 |
| 1.3.6.1.4.1.2007.1.4.83.1.17 | IdentityslEventObjects17 | current | Event SL.17 Packet dropped as the protocol type is enabled but packet arrived as bridged. (STB). | |
| 1.3.6.1.4.1.2007.1.4.83.1.17.1 | Scalarsl17-protocol-type | accessible-for-notify | current | Parameter 'protocol-type' in event SL.17 |
| 1.3.6.1.4.1.2007.1.4.83.1.17.2 | Scalarsl17-src-addr | accessible-for-notify | current | Parameter 'src-addr' in event SL.17 |
| 1.3.6.1.4.1.2007.1.4.83.1.17.3 | Scalarsl17-interface | accessible-for-notify | current | Parameter 'interface' in event SL.17 |
| 1.3.6.1.4.1.2007.1.4.83.1.18 | IdentityslEventObjects18 | current | Event SL.18 Packet dropped as the protocol filtering applies (STB). | |
| 1.3.6.1.4.1.2007.1.4.83.1.18.1 | Scalarsl18-protocol-type | accessible-for-notify | current | Parameter 'protocol-type' in event SL.18 |
| 1.3.6.1.4.1.2007.1.4.83.1.18.2 | Scalarsl18-interface | accessible-for-notify | current | Parameter 'interface' in event SL.18 |
| 1.3.6.1.4.1.2007.1.4.83.1.19 | IdentityslEventObjects19 | current | Event SL.19 The cable and the level converter on the interface are not compatible with each other. The self-test will fail. | |
| 1.3.6.1.4.1.2007.1.4.83.1.19.1 | Scalarsl19-cable-type | accessible-for-notify | current | Parameter 'cable-type' in event SL.19 |
| 1.3.6.1.4.1.2007.1.4.83.1.19.2 | Scalarsl19-level-converter-type | accessible-for-notify | current | Parameter 'level-converter-type' in event SL.19 |
| 1.3.6.1.4.1.2007.1.4.83.1.19.3 | Scalarsl19-interface | accessible-for-notify | current | Parameter 'interface' in event SL.19 |
| 1.3.6.1.4.1.2007.1.4.83.1.20 | IdentityslEventObjects20 | current | Event SL.20 There is an incompatibility between the mode of the cable (DCE or DTE) and the type of clocking used. The interface will not be brought up. | |
| 1.3.6.1.4.1.2007.1.4.83.1.20.1 | Scalarsl20-cable-type | accessible-for-notify | current | Parameter 'cable-type' in event SL.20 |
| 1.3.6.1.4.1.2007.1.4.83.1.20.2 | Scalarsl20-internal-external | accessible-for-notify | current | Parameter 'internal-external' in event SL.20 |
| 1.3.6.1.4.1.2007.1.4.83.1.20.3 | Scalarsl20-interface | accessible-for-notify | current | Parameter 'interface' in event SL.20 |
| 1.3.6.1.4.1.2007.1.4.83.1.21 | IdentityslEventObjects21 | current | Event SL.21 The interface failed self test because at least one of the modem signals was off. | |
| 1.3.6.1.4.1.2007.1.4.83.1.21.1 | Scalarsl21-cts | accessible-for-notify | current | Parameter 'cts' in event SL.21 |
| 1.3.6.1.4.1.2007.1.4.83.1.21.2 | Scalarsl21-dsr | accessible-for-notify | current | Parameter 'dsr' in event SL.21 |
| 1.3.6.1.4.1.2007.1.4.83.1.21.3 | Scalarsl21-dcd | accessible-for-notify | current | Parameter 'dcd' in event SL.21 |
| 1.3.6.1.4.1.2007.1.4.83.1.21.4 | Scalarsl21-interface | accessible-for-notify | current | Parameter 'interface' in event SL.21 |
| 1.3.6.1.4.1.2007.1.4.83.1.22 | IdentityslEventObjects22 | current | Event SL.22 A modem status change has occurred. The present state is described. | |
| 1.3.6.1.4.1.2007.1.4.83.1.22.1 | Scalarsl22-cts | accessible-for-notify | current | Parameter 'cts' in event SL.22 |
| 1.3.6.1.4.1.2007.1.4.83.1.22.2 | Scalarsl22-dsr | accessible-for-notify | current | Parameter 'dsr' in event SL.22 |
| 1.3.6.1.4.1.2007.1.4.83.1.22.3 | Scalarsl22-dcd | accessible-for-notify | current | Parameter 'dcd' in event SL.22 |
| 1.3.6.1.4.1.2007.1.4.83.1.22.4 | Scalarsl22-interface | accessible-for-notify | current | Parameter 'interface' in event SL.22 |
| 1.3.6.1.4.1.2007.1.4.83.1.23 | IdentityslEventObjects23 | current | Event SL.23 The interface was brought down because one of the modem signals was off. | |
| 1.3.6.1.4.1.2007.1.4.83.1.23.1 | Scalarsl23-cts | accessible-for-notify | current | Parameter 'cts' in event SL.23 |
| 1.3.6.1.4.1.2007.1.4.83.1.23.2 | Scalarsl23-dsr | accessible-for-notify | current | Parameter 'dsr' in event SL.23 |
| 1.3.6.1.4.1.2007.1.4.83.1.23.3 | Scalarsl23-dcd | accessible-for-notify | current | Parameter 'dcd' in event SL.23 |
| 1.3.6.1.4.1.2007.1.4.83.1.23.4 | Scalarsl23-interface | accessible-for-notify | current | Parameter 'interface' in event SL.23 |
| 1.3.6.1.4.1.2007.1.4.83.1.24 | IdentityslEventObjects24 | current | Event SL.24 The user-configured frame size for this interface is larger than the maximum that is allowed for the particular serial line device. The size is red… | |
| 1.3.6.1.4.1.2007.1.4.83.1.24.1 | Scalarsl24-configured-size | accessible-for-notify | current | Parameter 'configured-size' in event SL.24 |
| 1.3.6.1.4.1.2007.1.4.83.1.24.2 | Scalarsl24-maximum-size | accessible-for-notify | current | Parameter 'maximum-size' in event SL.24 |
| 1.3.6.1.4.1.2007.1.4.83.1.24.3 | Scalarsl24-interface | accessible-for-notify | current | Parameter 'interface' in event SL.24 |
| 1.3.6.1.4.1.2007.1.4.83.1.25 | IdentityslEventObjects25 | current | Event SL.25 A bad length field or truncated packet was detected in a SRT bridge packet. | |
| 1.3.6.1.4.1.2007.1.4.83.1.25.1 | Scalarsl25-actual-length | accessible-for-notify | current | Parameter 'actual-length' in event SL.25 |
| 1.3.6.1.4.1.2007.1.4.83.1.25.2 | Scalarsl25-claimed-length | accessible-for-notify | current | Parameter 'claimed-length' in event SL.25 |
| 1.3.6.1.4.1.2007.1.4.83.1.25.3 | Scalarsl25-interface | accessible-for-notify | current | Parameter 'interface' in event SL.25 |
| 1.3.6.1.4.1.2007.1.4.83.1.26 | IdentityslEventObjects26 | current | Event SL.26 An Incoming Serial Line packet is shorter than a minimally required Serial Line header. Such packet can not be processed and hence freed. | |
| 1.3.6.1.4.1.2007.1.4.83.1.26.1 | Scalarsl26-actual-length | accessible-for-notify | current | Parameter 'actual-length' in event SL.26 |
| 1.3.6.1.4.1.2007.1.4.83.1.26.2 | Scalarsl26-interface | accessible-for-notify | current | Parameter 'interface' in event SL.26 |
| 1.3.6.1.4.1.2007.1.4.83.1.27 | IdentityslEventObjects27 | current | Event SL.27 There is no level converter on this port of the Quad Serial Line card. The self-test will fail, and future self-tests will be cancelled. | |
| 1.3.6.1.4.1.2007.1.4.83.1.27.1 | Scalarsl27-interface | accessible-for-notify | current | Parameter 'interface' in event SL.27 |
| 1.3.6.1.4.1.2007.1.4.83.1.28 | IdentityslEventObjects28 | current | Event SL.28 There is a level converter of an unknown type on this port of the Quad Serial Line card. The self-test will fail, and future self-tests will be can… | |
| 1.3.6.1.4.1.2007.1.4.83.1.28.1 | Scalarsl28-converter-type | accessible-for-notify | current | Parameter 'converter-type' in event SL.28 |
| 1.3.6.1.4.1.2007.1.4.83.1.28.2 | Scalarsl28-interface | accessible-for-notify | current | Parameter 'interface' in event SL.28 |
| 1.3.6.1.4.1.2007.1.4.83.1.29 | IdentityslEventObjects29 | current | Event SL.29 The user-configured frame size for this interface is smaller than the minimum that is required for the particular serial line device. The size is i… | |
| 1.3.6.1.4.1.2007.1.4.83.1.29.1 | Scalarsl29-configured-size | accessible-for-notify | current | Parameter 'configured-size' in event SL.29 |
| 1.3.6.1.4.1.2007.1.4.83.1.29.2 | Scalarsl29-minimum-size | accessible-for-notify | current | Parameter 'minimum-size' in event SL.29 |
| 1.3.6.1.4.1.2007.1.4.83.1.29.3 | Scalarsl29-interface | accessible-for-notify | current | Parameter 'interface' in event SL.29 |
| 1.3.6.1.4.1.2007.1.4.83.1.30 | IdentityslEventObjects30 | current | Event SL.30 The maintenance routine is attempting to send a maintenance frame for Proteon Serial data-link, but the buffer for sending this has not been freed … | |
| 1.3.6.1.4.1.2007.1.4.83.1.30.1 | Scalarsl30-interface | accessible-for-notify | current | Parameter 'interface' in event SL.30 |
| 1.3.6.1.4.1.2007.1.4.83.1.31 | IdentityslEventObjects31 | current | Event SL.31 A buffer could not be allocated when needed to read the statistics counters from the Dual Serial interface. The counters should be successfully upd… | |
| 1.3.6.1.4.1.2007.1.4.83.1.31.1 | Scalarsl31-interface | accessible-for-notify | current | Parameter 'interface' in event SL.31 |
| 1.3.6.1.4.1.2007.1.4.83.1.32 | IdentityslEventObjects32 | current | Event SL.32 The allocation of a packet buffer for a DNX 300 serial line failed. This may be due to a shortage of either buffer memory or heap memory. (See the … | |
| 1.3.6.1.4.1.2007.1.4.83.1.32.1 | Scalarsl32-buffer-number | accessible-for-notify | current | Parameter 'buffer-number' in event SL.32 |
| 1.3.6.1.4.1.2007.1.4.83.1.32.2 | Scalarsl32-interface | accessible-for-notify | current | Parameter 'interface' in event SL.32 |
| 1.3.6.1.4.1.2007.1.4.83.1.33 | IdentityslEventObjects33 | current | Event SL.33 A packet buffer was allocated for the DNX 300 serial line, but that buffer crossed a 64 Kbyte memory boundary in the buffer memory. Since all of th… | |
| 1.3.6.1.4.1.2007.1.4.83.1.33.1 | Scalarsl33-buffer-number | accessible-for-notify | current | Parameter 'buffer-number' in event SL.33 |
| 1.3.6.1.4.1.2007.1.4.83.1.33.2 | Scalarsl33-interface | accessible-for-notify | current | Parameter 'interface' in event SL.33 |
| 1.3.6.1.4.1.2007.1.4.83.1.34 | IdentityslEventObjects34 | current | Event SL.34 The system does not detect an adapter cable in the network interface port. Self-test will fail. | |
| 1.3.6.1.4.1.2007.1.4.83.1.34.1 | Scalarsl34-interface | accessible-for-notify | current | Parameter 'interface' in event SL.34 |
| 1.3.6.1.4.1.2007.1.4.83.1.35 | IdentityslEventObjects35 | current | Event SL.35 A protocol that cannot be bridged by Proteon Serial Line's PSEUDO- ETHERNET bridging method has been configured over an interface using PSL PSEUDO-… | |
| 1.3.6.1.4.1.2007.1.4.83.1.35.1 | Scalarsl35-protocol-name | accessible-for-notify | current | Parameter 'protocol-name' in event SL.35 |
| 1.3.6.1.4.1.2007.1.4.83.1.35.2 | Scalarsl35-protocol-number | accessible-for-notify | current | Parameter 'protocol-number' in event SL.35 |
| 1.3.6.1.4.1.2007.1.4.83.1.35.3 | Scalarsl35-interface | accessible-for-notify | current | Parameter 'interface' in event SL.35 |
| 1.3.6.1.4.1.2007.1.4.83.1.36 | IdentityslEventObjects36 | current | Event SL.36 The interface is on mode loopback or echo and the timeout as expired. | |
| 1.3.6.1.4.1.2007.1.4.83.1.36.1 | Scalarsl36-interface | accessible-for-notify | current | Parameter 'interface' in event SL.36 |
| 1.3.6.1.4.1.2007.1.4.83.2 | NodeslNotifications | |||
| 1.3.6.1.4.1.2007.1.4.83.2.0 | NodeslNotificationsPrefix | |||
| 1.3.6.1.4.1.2007.1.4.83.2.0.1 | NotificationslNotification1 | current | Notification of Event SL.1 Message: 'no buffer available for selftest interface $1' Parameters list: $1: sl1-interface A packet buffer was not available when t… | |
| 1.3.6.1.4.1.2007.1.4.83.2.0.2 | NotificationslNotification2 | current | Notification of Event SL.2 Message: 'modem error with no DCD/DTS detected during selftest interface $1' Parameters list: $1: sl2-interface During the self-test… | |
| 1.3.6.1.4.1.2007.1.4.83.2.0.3 | NotificationslNotification3 | current | Notification of Event SL.3 Message: 'no echo acknowledgement received, timeout selftest interface $1' Parameters list: $1: sl3-interface During self-test, an E… | |
| 1.3.6.1.4.1.2007.1.4.83.2.0.4 | NotificationslNotification4 | current | Notification of Event SL.4 Message: 'bad length in DECNet packet actual $1 claimed $2 interface $3' Parameters list: $1: sl4-actual-length $2: sl4-claimed-leng… | |
| 1.3.6.1.4.1.2007.1.4.83.2.0.5 | NotificationslNotification5 | current | Notification of Event SL.5 Message: 'bad received packet header opcode $1 interface $2' Parameters list: $1: sl5-opcode $2: sl5-interface A network control pac… | |
| 1.3.6.1.4.1.2007.1.4.83.2.0.6 | NotificationslNotification6 | current | Notification of Event SL.6 Message: 'bad received packet header protocol $1 interface $2' Parameters list: $1: sl6-protocol $2: sl6-interface A serial line pac… | |
| 1.3.6.1.4.1.2007.1.4.83.2.0.7 | NotificationslNotification7 | current | Notification of Event SL.7 Message: 'start selftest interface $1' Parameters list: $1: sl7-interface Self-test is being started on the serial line. | |
| 1.3.6.1.4.1.2007.1.4.83.2.0.8 | NotificationslNotification8 | current | Notification of Event SL.8 Message: 'send echo packet interface $1' Parameters list: $1: sl8-interface An echo request is being sent on the serial line. | |
| 1.3.6.1.4.1.2007.1.4.83.2.0.9 | NotificationslNotification9 | current | Notification of Event SL.9 Message: 'receive test packet interface $1' Parameters list: $1: sl9-interface A test packet has been received on the serial line. | |
| 1.3.6.1.4.1.2007.1.4.83.2.0.10 | NotificationslNotification10 | current | Notification of Event SL.10 Message: 'receive echo acknowledgement packet interface $1' Parameters list: $1: sl10-interface An echo acknowledgement packet has … | |
| 1.3.6.1.4.1.2007.1.4.83.2.0.11 | NotificationslNotification11 | current | Notification of Event SL.11 Message: 'receive echo request packet interface $1' Parameters list: $1: sl11-interface An echo acknowledgement packet has been rec… | |
| 1.3.6.1.4.1.2007.1.4.83.2.0.12 | NotificationslNotification12 | current | Notification of Event SL.12 Message: 'sending maintenance test packet interface $1' Parameters list: $1: sl12-interface A test packet used for network maintene… | |
| 1.3.6.1.4.1.2007.1.4.83.2.0.13 | NotificationslNotification13 | current | Notification of Event SL.13 Message: 'Dropping the received Spanning Tree Bridged packet but bridging is disabled on interface $1' Parameters list: $1: sl13-in… | |
| 1.3.6.1.4.1.2007.1.4.83.2.0.14 | NotificationslNotification14 | current | Notification of Event SL.14 Message: 'Dual Serial Line board in slot $1 firmware download $2' Parameters list: $1: sl14-slot-num $2: sl14-ld-code Dual Serial L… | |
| 1.3.6.1.4.1.2007.1.4.83.2.0.15 | NotificationslNotification15 | current | Notification of Event SL.15 Message: 'Dual Serial Line board slot $1 Power-On Diagnostics status $2' Parameters list: $1: sl15-slot-num $2: sl15-pud-stat Dual … | |
| 1.3.6.1.4.1.2007.1.4.83.2.0.16 | NotificationslNotification16 | current | Notification of Event SL.16 Message: '$1 type pakcet filtered for protocol = $2 interface $3' Parameters list: $1: sl16-protocol-type $2: sl16-protocol $3: sl1… | |
| 1.3.6.1.4.1.2007.1.4.83.2.0.17 | NotificationslNotification17 | current | Notification of Event SL.17 Message: 'Dropped, protocol = $1 enabled but packet arrived as bridged from address $2, interface $3' Parameters list: $1: sl17-pro… | |
| 1.3.6.1.4.1.2007.1.4.83.2.0.18 | NotificationslNotification18 | current | Notification of Event SL.18 Message: 'Dropped, dsap = $1, Protocol filtreing applies, interface $2' Parameters list: $1: sl18-protocol-type $2: sl18-interface … | |
| 1.3.6.1.4.1.2007.1.4.83.2.0.19 | NotificationslNotification19 | current | Notification of Event SL.19 Message: 'Cable of type $1 is not compatible with level converter of type $2, interface $3' Parameters list: $1: sl19-cable-type $2… | |
| 1.3.6.1.4.1.2007.1.4.83.2.0.20 | NotificationslNotification20 | current | Notification of Event SL.20 Message: '$1 cable cannot be used with $2 clocking enabled, interface $3' Parameters list: $1: sl20-cable-type $2: sl20-internal-ex… | |
| 1.3.6.1.4.1.2007.1.4.83.2.0.21 | NotificationslNotification21 | current | Notification of Event SL.21 Message: 'Self test failed because of modem status, CTS = $1, DSR = $2, DCD = $3, ifc $4' Parameters list: $1: sl21-cts $2: sl21-ds… | |
| 1.3.6.1.4.1.2007.1.4.83.2.0.22 | NotificationslNotification22 | current | Notification of Event SL.22 Message: 'Modem status change CTS = $1, DSR = $2, DCD = $3, on interface $4' Parameters list: $1: sl22-cts $2: sl22-dsr $3: sl22-dc… | |
| 1.3.6.1.4.1.2007.1.4.83.2.0.23 | NotificationslNotification23 | current | Notification of Event SL.23 Message: 'Interface down because of modem status, CTS = $1, DSR = $2, DCD = $3, ifc $4' Parameters list: $1: sl23-cts $2: sl23-dsr … | |
| 1.3.6.1.4.1.2007.1.4.83.2.0.24 | NotificationslNotification24 | current | Notification of Event SL.24 Message: 'Configured frame size of $1 bytes too large, reducing to $2 bytes, interface $3' Parameters list: $1: sl24-configured-siz… | |
| 1.3.6.1.4.1.2007.1.4.83.2.0.25 | NotificationslNotification25 | current | Notification of Event SL.25 Message: 'bad length in SRT packet actual $1 claimed $2 interface $3' Parameters list: $1: sl25-actual-length $2: sl25-claimed-leng… | |
| 1.3.6.1.4.1.2007.1.4.83.2.0.26 | NotificationslNotification26 | current | Notification of Event SL.26 Message: 'Packet received is shorter than Serial line header, actual $1 interface $2' Parameters list: $1: sl26-actual-length $2: s… | |
| 1.3.6.1.4.1.2007.1.4.83.2.0.27 | NotificationslNotification27 | current | Notification of Event SL.27 Message: 'No level converter, disabling interface $1' Parameters list: $1: sl27-interface There is no level converter on this port … | |
| 1.3.6.1.4.1.2007.1.4.83.2.0.28 | NotificationslNotification28 | current | Notification of Event SL.28 Message: 'Unknown level converter type $1, disabling interface $2' Parameters list: $1: sl28-converter-type $2: sl28-interface Ther… | |
| 1.3.6.1.4.1.2007.1.4.83.2.0.29 | NotificationslNotification29 | current | Notification of Event SL.29 Message: 'Configured frame size of $1 bytes too small, increasing to $2 bytes, interface $3' Parameters list: $1: sl29-configured-s… | |
| 1.3.6.1.4.1.2007.1.4.83.2.0.30 | NotificationslNotification30 | current | Notification of Event SL.30 Message: 'Maintenance buffer busy, interface $1' Parameters list: $1: sl30-interface The maintenance routine is attempting to send … | |
| 1.3.6.1.4.1.2007.1.4.83.2.0.31 | NotificationslNotification31 | current | Notification of Event SL.31 Message: 'No packet for reading counters, interface $1' Parameters list: $1: sl31-interface A buffer could not be allocated when ne… | |
| 1.3.6.1.4.1.2007.1.4.83.2.0.32 | NotificationslNotification32 | current | Notification of Event SL.32 Message: 'Packet buffer allocation number $1 failed, interface $2' Parameters list: $1: sl32-buffer-number $2: sl32-interface The a… | |
| 1.3.6.1.4.1.2007.1.4.83.2.0.33 | NotificationslNotification33 | current | Notification of Event SL.33 Message: 'Packet buffer number $1 crossed 64 Kbyte page boundary, dropped, ifc $2' Parameters list: $1: sl33-buffer-number $2: sl33… | |
| 1.3.6.1.4.1.2007.1.4.83.2.0.34 | NotificationslNotification34 | current | Notification of Event SL.34 Message: 'No cable installed or installed cable broken or non-compatible, interface $1' Parameters list: $1: sl34-interface The sys… | |
| 1.3.6.1.4.1.2007.1.4.83.2.0.35 | NotificationslNotification35 | current | Notification of Event SL.35 Message: 'Protocol $1 ($2) can not be bridged over Proteon Serial Line using the pseudo-ethernet bridging method. Interface $3' Par… | |
| 1.3.6.1.4.1.2007.1.4.83.2.0.36 | NotificationslNotification36 | current | Notification of Event SL.36 Message: 'warning: test on ifc $1' Parameters list: $1: sl36-interface The interface is on mode loopback or echo and the timeout as… |