MIB Viewer

TIARA-HSSI-MIB

27 objects
MIB definitions for Tiara HSSI modules.
OIDNameAccessStatusDescription
1.3.6.1.4.1.3174.2.7.2IdentitytiaraHssiMibMIB definitions for Tiara HSSI modules.
1.3.6.1.4.1.3174.2.7.2.1TablehssiConfigTablenot-accessiblecurrentThe HSSI interface configurable parameters are listed in this table.
1.3.6.1.4.1.3174.2.7.2.1.1RowhssiConfigTableEntrynot-accessiblecurrentHSSI table entry.
1.3.6.1.4.1.3174.2.7.2.1.1.1ColumnhssiIfIndexnot-accessiblecurrentAn integer value that is an index in the entries of the ifTable (MIB-II) with a HSSI interface type.
1.3.6.1.4.1.3174.2.7.2.1.1.2ColumnhssiConfigClockRateread-writecurrentConfigures the clock rate (in Hertz) for the HSSI interface.
1.3.6.1.4.1.3174.2.7.2.1.1.3ColumnhssiConfigClockSourceread-writecurrentConfigures the clock source for the HSSI interface to either internal or line.
1.3.6.1.4.1.3174.2.7.2.1.1.4ColumnhssiConfigTxClockSourceread-writecurrentConfigures the transmit clock source for the HSSI interface to either internal or terminal. This variable is valid only for the HSSI interface on the USSI card.
1.3.6.1.4.1.3174.2.7.2.1.1.5ColumnhssiConfigRxClockSourceread-writecurrentConfigures the receive clock source for the HSSI interface to either internal or terminal. This variable is valid only for the HSSI interface on the USSI card
1.3.6.1.4.1.3174.2.7.2.1.1.6ColumnhssiConfigModeread-writecurrentConfigures the mode for the HSSI to either DCE or DTE.
1.3.6.1.4.1.3174.2.7.2.1.1.7ColumnhssiConfigDataModeread-writecurrentConfigures the data mode for the HSSI interface. This variable is valid only for the HSSI interface on the USSI card.
1.3.6.1.4.1.3174.2.7.2.1.1.8ColumnhssiConfigCRCread-writecurrentConfigures the cyclic redundancy check for the HSSI interface to either 16 or 32 bits.
1.3.6.1.4.1.3174.2.7.2.1.1.9ColumnhssiConfigProcessCtrlSignalread-writecurrentConfigures the processing of control signals (CA/TA) for the HSSI interface. This variable is valid only for the HSSI interface on the USSI card.
1.3.6.1.4.1.3174.2.7.2.1.1.10ColumnhssiDteLoopbackread-writecurrentConfigures the local DTE for loopback operation: TRUE : request local DTE to go into line loopback FALSE : request local DTE to abandon line loopback These com…
1.3.6.1.4.1.3174.2.7.2.1.1.11ColumnhssiDceLoopbackTestread-writecurrentConfigures the local/remote DCE for loopback operation. Three DCE loopback modes are available: line, cable, and remote. Use noTest to abandon any of the DCE l…
1.3.6.1.4.1.3174.2.7.2.2NodehssiTraps
1.3.6.1.4.1.3174.2.7.2.2.1NodehssiAlarmOnTrapHSSI alarm traps for the Alarm-On state.
1.3.6.1.4.1.3174.2.7.2.2.1NodehssiTrapVariables
1.3.6.1.4.1.3174.2.7.2.2.1.1ScalarhssiAlarmTypenot-accessiblecurrentSpecifies the type of alarm generated by the agent for the HSSI interface. Alarms are mode dependent; they are interpreted as follows: hssi-alarms-CA - CA not …
1.3.6.1.4.1.3174.2.7.2.2.2NodehssiAlarmOffTrapHSSI alarm traps for the Alarm-Off state.
1.3.6.1.4.1.3174.2.7.2.3TablehssiStatsTablenot-accessiblecurrentThe HSSI interface status parameters are listed in this table.
1.3.6.1.4.1.3174.2.7.2.3.1RowhssiStatsTableEntrynot-accessiblecurrentHSSI Statistics table entry.
1.3.6.1.4.1.3174.2.7.2.3.1.1ColumnhssiStatsAlarmStatusread-onlycurrentSpecifies the status of the HSSI alarm. If the particular bit is set, then it indicates that the alarm is in ON state. Alarm bits are mode dependent; they are …
1.3.6.1.4.1.3174.2.7.2.3.1.2ColumnhssiStatsFramesInread-onlycurrentSpecifies the number of incoming frames.
1.3.6.1.4.1.3174.2.7.2.3.1.3ColumnhssiStatsFramesOutread-onlycurrentSpecifies the number of outgoing frames.
1.3.6.1.4.1.3174.2.7.2.3.1.4ColumnhssiStatsOctetsInread-onlycurrentSpecifies the number of incoming octets.
1.3.6.1.4.1.3174.2.7.2.3.1.5ColumnhssiStatsOctetsOutread-onlycurrentSpecifies the number of outgoing octets.
1.3.6.1.4.1.3174.2.7.2.3.1.6ColumnhssiStatsCRCErrorsread-onlycurrentSpecifies the number of CRC errors that have been identified.