MIB Viewer

TP5000E

285 objects
This MIB is the equipment-specific subset MIB for the TP5000e system.
OIDNameAccessStatusDescription
1.3.6.1.4.1.9070.1.2.5.7.1Identitytp5000eThis MIB is the equipment-specific subset MIB for the TP5000e system.
1.3.6.1.4.1.9070.1.2.5.7.1.1Nodetp5000eSystemStatus
1.3.6.1.4.1.9070.1.2.5.7.1.1.1Tabletp5000eLedTablenot-accessiblecurrentThis is a table of the front panel LED status for a specified module. The module can be IMC, IOC1, IOC2, or an expansion shelf.
1.3.6.1.4.1.9070.1.2.5.7.1.1.1.1Rowtp5000eLedEntrynot-accessiblecurrentAn entry of the LED table contains status for one of the LEDs in a specified module. This table has a double index: entPhysicalIndex and tp5000LEDID.
1.3.6.1.4.1.9070.1.2.5.7.1.1.1.1.1Columntp5000eLedIDread-onlycurrentLED ID are LED names on the module front panel. Currently, the TP5000E system has 14 unique LED names. Some LED names (ALM and MGMT) are used on different modu…
1.3.6.1.4.1.9070.1.2.5.7.1.1.1.1.2Columntp5000eLedStatusread-onlycurrentLED status can be one of the following: Off(0), On(1), Red(2), Redblink(3), Green(4), Greenblink(5), Amber(6), Amberblink(7)
1.3.6.1.4.1.9070.1.2.5.7.1.1.2Tabletp5000eHWStatusTablenot-accessiblecurrentTable of hardware status for a specified module (IMC, IOC1, IOC2, or an expansion shelf). It includes power supply voltages and other status information for th…
1.3.6.1.4.1.9070.1.2.5.7.1.1.2.1Rowtp5000eHWStatusEntrynot-accessiblecurrentAn entry of hardware status table. The table index is entPhysicalIndex.
1.3.6.1.4.1.9070.1.2.5.7.1.1.2.1.1Columntp5000eHWStatusIndexnot-accessiblecurrentLocal index of the TP5000E hardware status table.
1.3.6.1.4.1.9070.1.2.5.7.1.1.2.1.2Columntp5000eHWStatusInforead-onlycurrentFor each module, the hardware status information is DisplayString type, and has a list of hardware status (power supply voltages, etc.). Example for IMC: -48V-…
1.3.6.1.4.1.9070.1.2.5.7.1.1.3Tabletp5000eModUpTimeTablenot-accessiblecurrentModule up time for a specified module (IMC, IOC1, IOC2, or an expansion shelf).
1.3.6.1.4.1.9070.1.2.5.7.1.1.3.1Rowtp5000eModUpTimeEntrynot-accessiblecurrentAn entry of the module up time table. The table index is entPhysicalIndex.
1.3.6.1.4.1.9070.1.2.5.7.1.1.3.1.1Columntp5000eModUpTimeIndexnot-accessiblecurrentLocal index of the module up time table.
1.3.6.1.4.1.9070.1.2.5.7.1.1.3.1.2Columntp5000eModuleUpTimeread-onlycurrentModule up time status for the module is a DisplayString type. Example for IMC: IMC uptime: 7 days 2 hrs 18 mins
1.3.6.1.4.1.9070.1.2.5.7.1.1.4Tabletp5000eModWarmUpTablenot-accessiblecurrentTable of warm-up status for a specified module (IMC, IOC1, IOC2, or an expansion shelf).
1.3.6.1.4.1.9070.1.2.5.7.1.1.4.1Rowtp5000eModWarmUpEntrynot-accessiblecurrentAn entry of the module warm-up status table. The table index is entPhysicalIndex.
1.3.6.1.4.1.9070.1.2.5.7.1.1.4.1.1Columntp5000eModWarmUpIndexnot-accessiblecurrentLocal index of the module warm-up status table.
1.3.6.1.4.1.9070.1.2.5.7.1.1.4.1.2Columntp5000eModWarmUpStatusread-onlycurrentModule warm-up status for the module is a DisplayString type. Example for an IOC: IOC1 warm-up status: complete (total 1651 secs)
1.3.6.1.4.1.9070.1.2.5.7.1.1.5Tabletp5000eModStatusTablenot-accessiblecurrentTable of operating status for a specified module in the system (IMC, IOC1, IOC2, or an expansion shelf).
1.3.6.1.4.1.9070.1.2.5.7.1.1.5.1Rowtp5000eModStatusEntrynot-accessiblecurrentAn entry of the module operating status table. The table index is entPhysicalIndex.
1.3.6.1.4.1.9070.1.2.5.7.1.1.5.1.1Columntp5000eModStatusIndexnot-accessiblecurrentLocal index of the module general status table.
1.3.6.1.4.1.9070.1.2.5.7.1.1.5.1.2Columntp5000eModStatusInforead-onlycurrentA list of operating status parameters for the module. Example for main shelf status information: System name: TP5000 IMC time: 2010-03-08 20:33:30 IMC uptime: …
1.3.6.1.4.1.9070.1.2.5.7.1.2Nodetp5000eAlarmAndEvent
1.3.6.1.4.1.9070.1.2.5.7.1.2.1Tabletp5000eActAlarmTablenot-accessiblecurrentList of alarms that are still active in the TP5000E system.
1.3.6.1.4.1.9070.1.2.5.7.1.2.1.1Rowtp5000eActAlarmEntrynot-accessiblecurrentEntry for one active alarm in the active alarm table. The table index is the local index.
1.3.6.1.4.1.9070.1.2.5.7.1.2.1.1.1Columntp5000eActAlarmIndexread-onlycurrentThe access (local) index of the active alarm table. The range of the table index is 1 to 500.
1.3.6.1.4.1.9070.1.2.5.7.1.2.1.1.2Columntp5000eActAlarmModIDread-onlycurrentName of the hardware module that generated this active alarm. In TP5000E system, the module name can be one of the following: SYS, IMC, IOC1, IOC2, IO, Exp0, E…
1.3.6.1.4.1.9070.1.2.5.7.1.2.1.1.3Columntp5000eActAlarmIDread-onlycurrentThe alarm ID uniquely identifies an alarm type. All alarm IDs are listed and described in the User Guide.
1.3.6.1.4.1.9070.1.2.5.7.1.2.1.1.4Columntp5000eActAlarmInternalIndexread-onlycurrentSee alarm second index in User Guide.
1.3.6.1.4.1.9070.1.2.5.7.1.2.1.1.5Columntp5000eActAlarmDateTimeread-onlycurrentThe date and time stamp for this active alarm. It is the time when the alarm was reported.
1.3.6.1.4.1.9070.1.2.5.7.1.2.1.1.6Columntp5000eActAlarmSeverityread-onlycurrentThe alarm severity level can be one of the following: -critical(2), critical condition -major(3), error condition -minor(4), warning condition -event(5), norma…
1.3.6.1.4.1.9070.1.2.5.7.1.2.1.1.7Columntp5000eActAlarmDescread-onlycurrentA description for the alarm. For a complete description of all alarms, please see the User Guide. A portion of the alarm and event table is shown below: ID Lev…
1.3.6.1.4.1.9070.1.2.5.7.1.2.2Tabletp5000eActEventTablenot-accessiblecurrentList of events that are still active in the TP5000E system.
1.3.6.1.4.1.9070.1.2.5.7.1.2.2.1Rowtp5000eActEventEntrynot-accessiblecurrentAn entry for one active event in the active event table. The table index is the local index.
1.3.6.1.4.1.9070.1.2.5.7.1.2.2.1.1Columntp5000eActEventIndexread-onlycurrentThe access (local) index of the active event table. The range of the table index is 1 to 500.
1.3.6.1.4.1.9070.1.2.5.7.1.2.2.1.2Columntp5000eActEventModIDread-onlycurrentName of the hardware module that reported the event. Module ID can be one of the following: SYS, IMC, IOC1, IOC2, or Exp0, Exp1,... Exp9. The module ID is only…
1.3.6.1.4.1.9070.1.2.5.7.1.2.2.1.3Columntp5000eActEventIDread-onlycurrentThe event ID uniquely identifies an event type. All event IDs are listed and described in the User Guide.
1.3.6.1.4.1.9070.1.2.5.7.1.2.2.1.4Columntp5000eActEventInternlIndexread-onlycurrentSee alarm second index in User Guide.
1.3.6.1.4.1.9070.1.2.5.7.1.2.2.1.5Columntp5000eActEventDateTimeread-onlycurrentThe date and time stamp for this active event. It is the time when the event was reported.
1.3.6.1.4.1.9070.1.2.5.7.1.2.2.1.6Columntp5000eActEventDescread-onlycurrentA description for the event. For a complete description of all events, please see the User Guide.
1.3.6.1.4.1.9070.1.2.5.7.1.2.3Tabletp5000eAlarmConfigTablenot-accessiblecurrentThe alarm configuration table. Each alarm is defined by five alarm configuration parameters: alarm id, alarm severity level, delay time, enable state, and a de…
1.3.6.1.4.1.9070.1.2.5.7.1.2.3.1Rowtp5000eAlarmConfigEntrynot-accessiblecurrentEntries of the alarm configuration table. Table index is a local index.
1.3.6.1.4.1.9070.1.2.5.7.1.2.3.1.1Columntp5000eAlarmConfigIndexread-onlycurrentThe index of the alarm configuration table. The range of the table index is 1 to 500.
1.3.6.1.4.1.9070.1.2.5.7.1.2.3.1.2Columntp5000eAlarmConfigAIDread-onlycurrentThis value is the Alarm ID. The alarm definition for each ID is defined in the User Guide.
1.3.6.1.4.1.9070.1.2.5.7.1.2.3.1.3Columntp5000eAlarmLevelSettingread-writecurrentThe alarm severity level can be one of the following: 2 Critical: critical condition 3 Major: error condition 4 Minor: warning condition 5 Event: normal but si…
1.3.6.1.4.1.9070.1.2.5.7.1.2.3.1.4Columntp5000eAlarmSettingDelayread-writecurrentAlarm delay in seconds. The alarm is not reported if the alarm condition disappears before this delay time is up. The purpose of the alarm delay is to prevent …
1.3.6.1.4.1.9070.1.2.5.7.1.2.3.1.5Columntp5000eEnableAlarmStateread-writecurrentAlarm state control flag. The flag can be Enable (1) or Disable (2). The default value is Enable. If an alarm is disabled, the system will never report conditi…
1.3.6.1.4.1.9070.1.2.5.7.1.2.3.1.6Columntp5000eAlarmConfigDescread-onlycurrentAlarm description (from hardcoded alarm definition table).
1.3.6.1.4.1.9070.1.2.5.7.1.2.4Scalartp5000eNumofStandingAlarmread-onlycurrentThe total number of currently active alarms in the TP5000E system, including those generated by the expansion shelves.
1.3.6.1.4.1.9070.1.2.5.7.1.2.5Scalartp5000eMessageGenerateread-writecurrentThis flag is used to generate all TP5000E alarm and event messages with this one action. The messages are sent to the alarm and event logs. This feature is use…
1.3.6.1.4.1.9070.1.2.5.7.1.3Nodetp5000eGlobalConfig
1.3.6.1.4.1.9070.1.2.5.7.1.3.1Tabletp5000eLogFileConfigTablenot-accessiblecurrentThe log file table is used to configure the sizes of various log files. There are four log files: alarm log, event log, command log, and security log.
1.3.6.1.4.1.9070.1.2.5.7.1.3.1.1Rowtp5000eLogFileConfigEntrynot-accessiblecurrentAn entry of the log file configuration table. Table index is the local index.
1.3.6.1.4.1.9070.1.2.5.7.1.3.1.1.1Columntp5000eLogFileConfigIndexread-onlycurrentThe local index of the log file configuration table.
1.3.6.1.4.1.9070.1.2.5.7.1.3.1.1.2Columntp5000eLogFileTypeNameread-onlycurrentThe log file name can be one of the following: Alarm, Event, Command, or Security. All alarm messages go into the alarm log. All event messages go into the eve…
1.3.6.1.4.1.9070.1.2.5.7.1.3.1.1.3Columntp5000eLogFileBufferSizeread-writecurrentThe size for the specified log file. Log file size is specified in unit of Kbytes. The default and the maximum size is 100 KB per log.
1.3.6.1.4.1.9070.1.2.5.7.1.3.2Tabletp5000eRemoteSyslogTablenot-accessiblecurrentRemote syslog file control table. It is used to configure a remote syslog server to receive log messages from TP5000K system. Only one remote syslog server is …
1.3.6.1.4.1.9070.1.2.5.7.1.3.2.1Rowtp5000eRemoteSyslogEntrynot-accessiblecurrentAn entry of the remote syslog file control table.
1.3.6.1.4.1.9070.1.2.5.7.1.3.2.1.1Columntp5000eRemoteSyslogIndexread-onlycurrentThe local index of the remote syslog file control table. At this time only the index value of 1 is supported.
1.3.6.1.4.1.9070.1.2.5.7.1.3.2.1.2Columntp5000eRemoteSyslogStateread-writecurrentThe remote syslog state control. The setting can be either Enable (1) or Disable (2). Once this is set to Enable, all TP5000E log messages (intended for any of…
1.3.6.1.4.1.9070.1.2.5.7.1.3.2.1.3Columntp5000eRemoteSyslogAddrread-writecurrentThe IP address of the remote syslog machine. The format is xxx.xxx.xxx.xxx. It suports only IPv4 format. 0.0.0.0 denotes remote-syslog address is IPv6
1.3.6.1.4.1.9070.1.2.5.7.1.3.3Tabletp5000eRedundTablenot-accessiblecurrentThe port redundancy table for IOC modules. Currently the system is hardcoded for card redundancy. The only redundancy selection is whether to enable port redun…
1.3.6.1.4.1.9070.1.2.5.7.1.3.3.1Rowtp5000eRedundEntrynot-accessiblecurrentAn entry of the IOC port redundancy table. Table index is module index
1.3.6.1.4.1.9070.1.2.5.7.1.3.3.1.1Columntp5000eRedundModuleIDread-onlycurrentThe module ID can be either IOC1 or IOC2. The system is currently hardcoded for card redundancy (if two IOC cards are present, they are always configured as a …
1.3.6.1.4.1.9070.1.2.5.7.1.3.3.1.2Columntp5000eRedundModStateread-writecurrentPort redundancy state can be either Enable (1) or Disable (2). When it is Enable, the two Ethernet ports on the specified IOC module will form a bonded pair. W…
1.3.6.1.4.1.9070.1.2.5.7.1.3.3.1.3Columntp5000eRedundActivePortread-writecurrentThe port ID of the active port on an IOC module. The active port ID is either Eth1 (1) or Eth2 (2). This object can be used to set the desired port to be the a…
1.3.6.1.4.1.9070.1.2.5.7.1.3.4Tabletp5000eImageTablenot-accessiblecurrentFirmware image information for the selected module (IMC, IOC1, IOC2, or an expansion shelf). In TP5000E, each module can store two firmware images. The image t…
1.3.6.1.4.1.9070.1.2.5.7.1.3.4.1Rowtp5000eImageEntrynot-accessiblecurrentEntry of the firmware image table. Each entry contains objects of each module image information. The image table index is the entPhysicalIndex.
1.3.6.1.4.1.9070.1.2.5.7.1.3.4.1.1Columntp5000eImageIndexnot-accessiblecurrentLocal index of the firmware image table.
1.3.6.1.4.1.9070.1.2.5.7.1.3.4.1.2Columntp5000eImageNextBootread-writecurrentThis field indicates whether the board will be booted from this firmware image next time. Values can be either 'yes' or 'no.' Only one of the images can be sel…
1.3.6.1.4.1.9070.1.2.5.7.1.3.4.1.3Columntp5000eImageIDread-onlycurrentFor each module, there are up to two images. The range of image ID is 1 and 2.
1.3.6.1.4.1.9070.1.2.5.7.1.3.4.1.4Columntp5000eImageCurrStateread-onlycurrentThe current state of whether an image active or not. The value is either active (1) or inactive (2).
1.3.6.1.4.1.9070.1.2.5.7.1.3.4.1.5Columntp5000eImageInfoMsgread-onlycurrentThe information message for an image.
1.3.6.1.4.1.9070.1.2.5.7.1.3.5Tabletp5000eRebootTablenot-accessiblecurrentThe action to reboot a specified module (IMC, IOC1, IOC2, or an expansion shelf).
1.3.6.1.4.1.9070.1.2.5.7.1.3.5.1Rowtp5000eRebootEntrynot-accessiblecurrentAn entry contains objects of the module reboot information. The table index is entPhysicalIndex. Depending on the entPhysicalIndex, reboot can apply to the who…
1.3.6.1.4.1.9070.1.2.5.7.1.3.5.1.1Columntp5000eRebootIndexnot-accessiblecurrentLocal index of the module reboot table.
1.3.6.1.4.1.9070.1.2.5.7.1.3.5.1.2Columntp5000eRebootActionread-writecurrentThe action to reboot the module. Value is either Apply (1) or Nonapply (2). The active firmware image is used when the module is rebooted. Use tp5000eImageTabl…
1.3.6.1.4.1.9070.1.2.5.7.1.3.6Tabletp5000eAuthRADIUSTablenot-accessiblecurrentThis table contains IP addresses and access keys for the Radius authentication server. Radius enable state is set in tp5000eRadiusState outside of this table.
1.3.6.1.4.1.9070.1.2.5.7.1.3.6.1Rowtp5000eAuthRADIUSEntrynot-accessiblecurrentAn entry of the RADIUS table.
1.3.6.1.4.1.9070.1.2.5.7.1.3.6.1.1Columntp5000eAuthRADIUSIndexread-onlycurrentA local index to the RADIUS table. Currently the system only supports RADIUS index value of 1.
1.3.6.1.4.1.9070.1.2.5.7.1.3.6.1.2Columntp5000eServerRADIUSIPAddressread-writecurrentThe RADIUS server's IP address. Format for IPv4 address is xxx.xxx.xxx.xxx. An IP address cannot be set up if authRADIUS key value is none.
1.3.6.1.4.1.9070.1.2.5.7.1.3.6.1.3Columntp5000eAuthRADIUSKeyread-writecurrentAuthentication key for RADIUS server access.
1.3.6.1.4.1.9070.1.2.5.7.1.3.7Scalartp5000eAssetNumread-writecurrentUser assigned inventory asset number for the system.
1.3.6.1.4.1.9070.1.2.5.7.1.3.8Scalartp5000eIntraCommIPSetread-writecurrentIntra-communication IP set between IMC, IOCs and Expansion shelves. Value can be class A (1), B (2), C (3). Their ranges are: A: IP address range 10.0.250.8 to…
1.3.6.1.4.1.9070.1.2.5.7.1.3.9Scalartp5000eRadiusStateread-writecurrentThe RADIUS state can be either Enable (1) or Disable (2). Use tp5000eAuthRadiusTable to configure access to the Radius server.
1.3.6.1.4.1.9070.1.2.5.7.1.3.10Scalartp5000eLastConfigread-onlycurrentThe Last Config Update.
1.3.6.1.4.1.9070.1.2.5.7.1.4Nodetp5000eGlobalService
1.3.6.1.4.1.9070.1.2.5.7.1.4.1Tabletp5000ePacketServiceTablenot-accessiblecurrentThis table defines packet service for the specified Ethernet interface on the IOC (main shelf). Currently, this table only applies to the main shelf IOC ports …
1.3.6.1.4.1.9070.1.2.5.7.1.4.1.1Rowtp5000ePacketServiceEntrynot-accessiblecurrentAn entry of the packet service table. Table index is ifIndex (index for interfaces and ports). The system is currently hardcoded for card redundancy (if two IO…
1.3.6.1.4.1.9070.1.2.5.7.1.4.1.1.1Columntp5000ePacketServiceIndexnot-accessiblecurrentLocal index of the packet service selection table.
1.3.6.1.4.1.9070.1.2.5.7.1.4.1.1.2Columntp5000ePacketServiceModeread-writecurrentThe packet service for this port. Value can be PTP Grandmaster (1), PTP probe (2), NTP server (3), or NTP probe (4). Note that packet service selection is done…
1.3.6.1.4.1.9070.1.2.5.7.1.4.2Tabletp5000eSSMOptionTablenot-accessiblecurrentThis is the table for selecting SSM network option for a specified shelf (IOC or Expansion shelf). Main shelf and expansion shelves can each have its own selec…
1.3.6.1.4.1.9070.1.2.5.7.1.4.2.1Rowtp5000eSSMOptionEntrynot-accessiblecurrentAn entry of the SSM option table. Table index is entPhysicalIndex.
1.3.6.1.4.1.9070.1.2.5.7.1.4.2.1.1Columntp5000eSSMOptionIndexnot-accessiblecurrentLocal index of the SSM option selection table.
1.3.6.1.4.1.9070.1.2.5.7.1.4.2.1.2Columntp5000eSSMOptionread-writecurrentNetwork option for SSM can be Option 1 (1) or Option 2 (2). Option 1 is for E1 based network. Option 2 is for DS1 based network. ITU-T G.781 and G.8265.1 speci…
1.3.6.1.4.1.9070.1.2.5.7.1.4.3Scalartp5000ePTPClientDataTableLockread-writecurrentThe ptpClientDataTableLock will control the internal semaphore to lock or unlock the ptpClientDataTable. The table must be locked before it can be read. When t…
1.3.6.1.4.1.9070.1.2.5.7.1.4.4Scalartp5000ePacketServiceExtendedModeread-writecurrentFixed configuration. IOC1-1: PTP-GM IOC1-2: NTP-Server
1.3.6.1.4.1.9070.1.2.5.7.1.5Nodetp5000ePTPClientMgmt
1.3.6.1.4.1.9070.1.2.5.7.1.6Nodetp5000eReferenceStatus
1.3.6.1.4.1.9070.1.2.5.7.1.6.1Tabletp5000eInputPQLTablenot-accessiblecurrentStatus table for a specified reference input. PQL (priority quality level) is reference quality used internally by the TP5000E system. Input SSM and other refe…
1.3.6.1.4.1.9070.1.2.5.7.1.6.1.1Rowtp5000eInputPQLEntrynot-accessiblecurrentAn entry of the reference input status table. Index of the table is ifIndex.
1.3.6.1.4.1.9070.1.2.5.7.1.6.1.1.1Columntp5000eInputRefNameread-onlycurrentThe name of the reference. Currently supported references are GNSS, GPS, 1PPS+TOD1, 1PPS+TOD2, Span input 1, and Span input 2.
1.3.6.1.4.1.9070.1.2.5.7.1.6.1.1.2Columntp5000eInputRefActualPQLread-onlycurrentThis PQL value either corresponds to the actual SSM value in the reference (when SSM is available) or the default PQL value for the reference.
1.3.6.1.4.1.9070.1.2.5.7.1.6.1.1.3Columntp5000eInputRefQualifiedread-onlycurrentThis is the selection status for the reference. Its value is one of the following: Disabled, Disqualified, Qualified, or Selected.
1.3.6.1.4.1.9070.1.2.5.7.1.6.2Nodetp5000eSymmMetrics
1.3.6.1.4.1.9070.1.2.5.7.1.7Nodetp5000eRefConfig
1.3.6.1.4.1.9070.1.2.5.7.1.7.1Scalartp5000eRefTimingModeread-writecurrentThe timing mode of the entire TP5000E system, and it can be either Time (1) or Frequency (2). Whether the system is in Time or Frequency mode affects how time …
1.3.6.1.4.1.9070.1.2.5.7.1.7.2Scalartp5000eRefSelectionCriteriaread-writecurrentReference selection criteria applies to the entire TP5000E system, and it can be Priority based (2) or SSM based (3). Manual mode (1) is currently not supporte…
1.3.6.1.4.1.9070.1.2.5.7.1.7.3Tabletp5000eRefConfigTablenot-accessiblecurrentThe reference configuration table is used to configure reference selection parameters for a specified reference input. Configuration parameters include referen…
1.3.6.1.4.1.9070.1.2.5.7.1.7.3.1Rowtp5000eRefConfigEntrynot-accessiblecurrentAn entry of the reference configuration table. Table index is the ifIndex (port index).
1.3.6.1.4.1.9070.1.2.5.7.1.7.3.1.1Columntp5000eRefNameread-onlycurrentName of the reference. Examples: GNSS, GPS, E1, 1PPS+TOD.
1.3.6.1.4.1.9070.1.2.5.7.1.7.3.1.2Columntp5000eRefStateread-writecurrentReference input state can be either Enable (1) or Disable (2). Only enabled references are used in reference selection.
1.3.6.1.4.1.9070.1.2.5.7.1.7.3.1.3Columntp5000eRefPriorityread-writecurrentPriority value assigned to a reference. Its range is 1 to 16. It is used as one of the selection criteria for reference selection.
1.3.6.1.4.1.9070.1.2.5.7.1.7.3.1.4Columntp5000eRefPQLStateread-writecurrentThe PQL state of a reference can be either Enable (1) or Disable (2). If PQL is enabled for a reference, the actual PQL value that the system uses either corre…
1.3.6.1.4.1.9070.1.2.5.7.1.7.3.1.5Columntp5000eRefPQLread-writecurrentConfigured reference PQL value. Its range is 1 to 3, with 1 indicating the highest quality level. This PQL value is used when the reference PQL state is disabl…
1.3.6.1.4.1.9070.1.2.5.7.1.8Nodetp5000eClock
1.3.6.1.4.1.9070.1.2.5.7.1.8.1Nodetp5000eClockStatus
1.3.6.1.4.1.9070.1.2.5.7.1.8.1.1Tabletp5000eClockStatusTablenot-accessiblecurrentThis table contains status information for the clock in each shelf.
1.3.6.1.4.1.9070.1.2.5.7.1.8.1.1.1Rowtp5000eClockStatusEntrynot-accessiblecurrentAn entry in the Clock Status Table. Table index is entPhysicalIndex (a shelf or a module).
1.3.6.1.4.1.9070.1.2.5.7.1.8.1.1.1.1Columntp5000eClockStatusIndexnot-accessiblecurrentLocal index of the module clock status table.
1.3.6.1.4.1.9070.1.2.5.7.1.8.1.1.1.2Columntp5000eServoControlStatusread-onlycurrentThe clock servo status of clock module (IOC or expansion). This status is also called clock status in CLI. For expansion shelves, the clock status is the combi…
1.3.6.1.4.1.9070.1.2.5.7.1.8.1.1.1.3Columntp5000ePhaseOffsetread-onlycurrentThis is the phase offset in ns between the reference and output. This is applicable only when the selected reference is a time reference.
1.3.6.1.4.1.9070.1.2.5.7.1.8.2Nodetp5000eClockConfig
1.3.6.1.4.1.9070.1.2.5.7.1.8.2.1Scalartp5000eBridgingTimeread-writecurrentBridging time in seconds. Range 100-200000. Default value Bridging is a clock state between normal tracking and holdover. When all references are lost, the clo…
1.3.6.1.4.1.9070.1.2.5.7.1.8.2.2Scalartp5000eAutoSyncread-writecurrentThe auto sync state can be either Enable (1) or Disable (2). Auto sync allows IOC time and IMC time to synchronize when IOC is in time mode passed warmup. If a…
1.3.6.1.4.1.9070.1.2.5.7.1.8.2.3Scalartp5000eSyncread-writecurrentThis object is used to force system time and phase to synchronize to the selected reference (synchronize between IMC and IOC). This object is write-only, and t…
1.3.6.1.4.1.9070.1.2.5.7.1.8.2.4Scalartp5000eHoldoverExceededTimeQzread-writecurrentholdover time in seconds for holdover-exceeded-time-qz, Range (0|900-3000000). 0 is disable
1.3.6.1.4.1.9070.1.2.5.7.1.8.2.5Scalartp5000eHoldoverExceededTimeRbread-writecurrentholdover time in seconds for holdover-exceeded-time-rb, Range (0|900-3000000). 0 is disable
1.3.6.1.4.1.9070.1.2.5.7.1.9Nodetp5000eHardwareHierarchy
1.3.6.1.4.1.9070.1.2.5.7.1.9.1Tabletp5000eIfTablenot-accessiblecurrentThis table describes physical hierarchy of TP5000E system down to the individual logical interface which can be a physical interface (like GPS port) or a virtu…
1.3.6.1.4.1.9070.1.2.5.7.1.9.1.1Rowtp5000eIfEntrynot-accessiblecurrentAn entry of the TP5000E interface table. Table index is ifIndex.
1.3.6.1.4.1.9070.1.2.5.7.1.9.1.1.1Columntp5000eIfIndexread-onlycurrentLocal index of this table.
1.3.6.1.4.1.9070.1.2.5.7.1.9.1.1.2Columntp5000eIfModuleIDread-onlycurrentModule ID is the name of the physical module. Its value can be one of the following: IMC (2), IOC1 (3), IOC2 (4), IO (5), exp0 (6),... exp9 (15). Module ID is …
1.3.6.1.4.1.9070.1.2.5.7.1.9.1.1.3Columntp5000eIfPortIDread-onlycurrentThe current inventory port ID. The range depends on the module ID and P/N index that together uniquely identify port configuration for each module. Example: ra…
1.3.6.1.4.1.9070.1.2.5.7.1.9.1.1.4Columntp5000eIfTableIndexread-onlycurrentThe current interface index from ifTable. Each local index is mapped to a corresponding index in the ifTable.
1.3.6.1.4.1.9070.1.2.5.7.1.9.2Tabletp5000eEntPhysicalTablenot-accessiblecurrentThis table describes physical hierarchy of TP5000K system down to the module (container) level.
1.3.6.1.4.1.9070.1.2.5.7.1.9.2.1Rowtp5000eEntPhysicalEntrynot-accessiblecurrentAn entry of the TP5000E physical entity table. Each entry uniquely identifies the connector configuration (a module may have multiple versions with different c…
1.3.6.1.4.1.9070.1.2.5.7.1.9.2.1.1Columntp5000eEntPhysicalIndexread-onlycurrentLocal index of the TP5000E physical entity table.
1.3.6.1.4.1.9070.1.2.5.7.1.9.2.1.2Columntp5000eEntPhysicalModuleIDread-onlycurrentModule ID is the name of the physical module. Its value can be one of the following: IMC (2), IOC1 (3), IOC2 (4), IO (5), exp0 (6),... exp9 (15). Module ID is …
1.3.6.1.4.1.9070.1.2.5.7.1.9.2.1.3Columntp5000eEntPhysicalStackIDread-onlycurrentStack ID is the ID of the TP5000E system that the current module resides in. Stack ID is currently hardcoded to 1, and NMS needs to use other means (such as IP…
1.3.6.1.4.1.9070.1.2.5.7.1.9.2.1.4Columntp5000eEntPhysicalChassisIDread-onlycurrentChassis ID is the equipment shelf ID. In TP5000E system, there is one main shelf (chassis ID = 1) and up to ten expansion shelves (chassis ID range 2 to 11).
1.3.6.1.4.1.9070.1.2.5.7.1.9.2.1.5Columntp5000eEntPhysicalPartIndexread-onlycurrentPart number index uniquely identifies the connector configuration of a given module type. Currently, there are four versions of IMC, and the valid part number …
1.3.6.1.4.1.9070.1.2.5.7.1.9.2.1.6Columntp5000eEntPhysicalTableIndexread-onlycurrentEach entry (module) in this table is mapped to an entity index in the entityPhysicalTable in the Entity-MIB.
1.3.6.1.4.1.9070.1.2.5.7.1.10Nodetp5000eVlanConfig
1.3.6.1.4.1.9070.1.2.5.7.1.10.1Tabletp5000eNonfixedVlanTablenot-accessiblecurrentIn the non-fixed VLAN table, VLANs can be added or removed. As a VLAN is added or removed, the table index is updated. The non-fixed VLAN table can hold 484 VL…
1.3.6.1.4.1.9070.1.2.5.7.1.10.1.1Rowtp5000eNonfixedVlanEntrynot-accessiblecurrentAn entry of the non-fixed VLAN table. Table index is the local index, but each entry uniquely identifies a VLAN through the IfIndex.
1.3.6.1.4.1.9070.1.2.5.7.1.10.1.1.1Columntp5000eNonfixedVlanIndexnot-accessiblecurrentLocal index of the non-fixed VLAN table.
1.3.6.1.4.1.9070.1.2.5.7.1.10.1.1.2Columntp5000eNonfixedVlanIfIndexread-onlycurrentIfIndex of the current non-fixed VLAN (17-500).
1.3.6.1.4.1.9070.1.2.5.7.1.10.1.1.3Columntp5000eNonfixedVlanModuleIDread-createcurrentModule ID is the name of the physical module (the inventory module ID) in which the current non-fixed VLAN is defined. Module ID is the name of the physical mo…
1.3.6.1.4.1.9070.1.2.5.7.1.10.1.1.4Columntp5000eNonfixedVlanPortIDread-createcurrentPhysical port ID where the current non-fixed VLAN is defined. The range depends on the module ID and P/N index which together uniquely identify port configurat…
1.3.6.1.4.1.9070.1.2.5.7.1.10.1.1.5Columntp5000eNonfixedVlanIdread-createcurrentThe VLAN ID of the current VLAN interface. The range is 0~4094. If a VLAN ID is set to 0, the associated VLAN interface of this VLAN index will be removed from…
1.3.6.1.4.1.9070.1.2.5.7.1.10.1.1.6Columntp5000eNonfixedVlanPriorityread-createcurrentThe priority of the VLAN ID. The range is 0 to 7. VLAN priority and VLAN ID must be configured at same time when a VLAN interface row is added. Once a VLAN pri…
1.3.6.1.4.1.9070.1.2.5.7.1.10.1.1.7Columntp5000eNonfixedVlanIPv4Addrread-createcurrentThe IPv4 address to which this entry's addressing information pertains. Implementers need to be aware that if the size of ipAddressAddr exceeds 116 octets, OID…
1.3.6.1.4.1.9070.1.2.5.7.1.10.1.1.8Columntp5000eNonfixedVlanNetmaskread-createcurrentThe mask of an IPv4 interface. The address format is : xxx.xxx.xxx.xxx.
1.3.6.1.4.1.9070.1.2.5.7.1.10.1.1.9Columntp5000eNonfixedVlanStateread-createcurrentThis is the state of an individual non-fixed VLAN. Value can be Enable (1) or Disable (2). Setting an individual VLAN state to Enable is not enough for the VLA…
1.3.6.1.4.1.9070.1.2.5.7.1.10.1.1.10Columntp5000eNonfixedVlanRowStatusread-createcurrentThe row status of non-fixed VLAN table is used to control row actions. The status column has six defined actions (values): -`active(1)', which indicates that t…
1.3.6.1.4.1.9070.1.2.5.7.1.10.2Tabletp5000eFixedVlanTablenot-accessiblecurrentIn the fixed VLAN table, VLANs are pre-assigned to the VLAN table index. They cannot be added or removed from the table.
1.3.6.1.4.1.9070.1.2.5.7.1.10.2.1Rowtp5000eFixedVlanEntrynot-accessiblecurrentAn entry of the fixed VLAN table. Table index is ifIndex and local index.
1.3.6.1.4.1.9070.1.2.5.7.1.10.2.1.1Columntp5000eFixedVlanIndexnot-accessiblecurrentLocal index of the fixed VLAN table.
1.3.6.1.4.1.9070.1.2.5.7.1.10.2.1.2Columntp5000eFixedVlanIdread-writecurrentThe VLAN ID of the current VLAN interface. The range is 0~4094. If a VLAN ID is set to 0, the associated VLAN interface of this VLAN index will be removed from…
1.3.6.1.4.1.9070.1.2.5.7.1.10.2.1.3Columntp5000eFixedVlanPriorityread-writecurrentThe priority of the VLAN ID. The range is 0 to 7. VLAN priority and VLAN ID must be configured at same time when a VLAN interface row is added. Once a VLAN pri…
1.3.6.1.4.1.9070.1.2.5.7.1.10.2.1.4Columntp5000eFixedVlanIPv4Addrread-writecurrentThe IPv4 address to which this entry's addressing information pertains. Implementers need to be aware that if the size of ipAddressAddr exceeds 116 octets, OID…
1.3.6.1.4.1.9070.1.2.5.7.1.10.2.1.5Columntp5000eFixedVlanNetmaskread-writecurrentThe mask of an IPv4 interface. The address format is : xxx.xxx.xxx.xxx.
1.3.6.1.4.1.9070.1.2.5.7.1.10.2.1.6Columntp5000eFixedVlanGatewayread-writecurrentThe gateway of an IPv4 interface. The address format is : xxx.xxx.xxx.xxx.
1.3.6.1.4.1.9070.1.2.5.7.1.10.2.1.7Columntp5000eFixedVlanStateread-writecurrentThis is the state of an individual fixed VLAN. Value can be Enable (1) or Disable (2). Setting an individual VLAN state to Enable is not enough for the VLAN to…
1.3.6.1.4.1.9070.1.2.5.7.1.10.3Tabletp5000eVlanModeTablenot-accessiblecurrentVLAN mode table. The VLAN mode table is used to enable or disable all VLANs in a physical port.
1.3.6.1.4.1.9070.1.2.5.7.1.10.3.1Rowtp5000eVlanModeEntrynot-accessiblecurrentAn entry of the VLAN mode table. Table index is ifIndex (port and interface index) and local index.
1.3.6.1.4.1.9070.1.2.5.7.1.10.3.1.1Columntp5000eVlanModeIndexnot-accessiblecurrentLocal index of the VLAN mode table.
1.3.6.1.4.1.9070.1.2.5.7.1.10.3.1.2Columntp5000eVlanModeModuleIDread-onlycurrentModule ID is the name of the physical module (the inventory module ID) in which the current VLAN is defined. Module ID is the name of the physical module. Its …
1.3.6.1.4.1.9070.1.2.5.7.1.10.3.1.3Columntp5000eVlanModePortIDread-onlycurrentPhysical port ID where the current VLAN is defined.
1.3.6.1.4.1.9070.1.2.5.7.1.10.3.1.4Columntp5000eVlanModeValueread-writecurrentVLAN mode for the specified physical port. Value can be Enable or Disable. This parameter can enable or disable all VLANs in this physical port, but setting th…
1.3.6.1.4.1.9070.1.2.5.7.1.10.4Tabletp5000eIPv6NonfixedVlanTablenot-accessiblecurrentDescription.
1.3.6.1.4.1.9070.1.2.5.7.1.10.4.1Rowtp5000eIPv6NonfixedVlanEntrynot-accessiblecurrentDescription.
1.3.6.1.4.1.9070.1.2.5.7.1.10.4.1.1Columntp5000eIPv6NonfixedVlanIndexnot-accessiblecurrentDescription.
1.3.6.1.4.1.9070.1.2.5.7.1.10.4.1.2Columntp5000eIPv6NonfixedVlanIfIndexread-onlycurrentDescription.
1.3.6.1.4.1.9070.1.2.5.7.1.10.4.1.3Columntp5000eIPv6NonfixedVlanModuleIDread-createcurrentDescription.
1.3.6.1.4.1.9070.1.2.5.7.1.10.4.1.4Columntp5000eIPv6NonfixedVlanPortIDread-createcurrentDescription.
1.3.6.1.4.1.9070.1.2.5.7.1.10.4.1.5Columntp5000eIPv6NonfixedVlanIdread-createcurrentDescription.
1.3.6.1.4.1.9070.1.2.5.7.1.10.4.1.6Columntp5000eIPv6NonfixedVlanPriorityread-createcurrentDescription.
1.3.6.1.4.1.9070.1.2.5.7.1.10.4.1.7Columntp5000eIPv6NonfixedVlanAddrread-createcurrentDescription.
1.3.6.1.4.1.9070.1.2.5.7.1.10.4.1.8Columntp5000eIPv6NonfixedVlanPrefixread-createcurrentDescription.
1.3.6.1.4.1.9070.1.2.5.7.1.10.4.1.9Columntp5000eIPv6NonfixedVlanStateread-createcurrentDescription.
1.3.6.1.4.1.9070.1.2.5.7.1.10.4.1.10Columntp5000eIPv6NonfixedVlanRowStatusread-createcurrentDescription.
1.3.6.1.4.1.9070.1.2.5.7.1.10.5Tabletp5000eIPv6FixedVlanTablenot-accessiblecurrentDescription.
1.3.6.1.4.1.9070.1.2.5.7.1.10.5.1Rowtp5000eIPv6FixedVlanEntrynot-accessiblecurrentDescription.
1.3.6.1.4.1.9070.1.2.5.7.1.10.5.1.1Columntp5000eIPv6FixedVlanIndexnot-accessiblecurrentDescription.
1.3.6.1.4.1.9070.1.2.5.7.1.10.5.1.2Columntp5000eIPv6FixedVlanIdread-writecurrentDescription.
1.3.6.1.4.1.9070.1.2.5.7.1.10.5.1.3Columntp5000eIPv6FixedVlanPriorityread-writecurrentDescription.
1.3.6.1.4.1.9070.1.2.5.7.1.10.5.1.4Columntp5000eIPv6FixedVlanAddrread-writecurrentDescription.
1.3.6.1.4.1.9070.1.2.5.7.1.10.5.1.5Columntp5000eIPv6FixedVlanPrefixread-writecurrentDescription.
1.3.6.1.4.1.9070.1.2.5.7.1.10.5.1.6Columntp5000eIPv6FixedVlanDefaultRouterread-writecurrentDescription.
1.3.6.1.4.1.9070.1.2.5.7.1.10.5.1.7Columntp5000eIPv6FixedVlanStateread-writecurrentDescription.
1.3.6.1.4.1.9070.1.2.5.7.1.11Nodetp5000eAlarmNotification
1.3.6.1.4.1.9070.1.2.5.7.1.11.1Nodetp5000eNotifyElements
1.3.6.1.4.1.9070.1.2.5.7.1.11.1.1Scalartp5000eNotifyModuleIdread-onlycurrentModule ID is the name of the physical module that generated the notification.
1.3.6.1.4.1.9070.1.2.5.7.1.11.1.2Scalartp5000eNotifyAlarmEventIDread-onlycurrentThe alarm or event ID of the notification.
1.3.6.1.4.1.9070.1.2.5.7.1.11.1.3Scalartp5000eNotifyIndexread-onlycurrentInternal alarm index for a notification.
1.3.6.1.4.1.9070.1.2.5.7.1.11.1.4Scalartp5000eNotifySeverityread-onlycurrentAlarm severity: 0 - clear alarm or event 2 - critical alarm (set, if non-transient) 3 - major alarm (set, if non-transient) 4 - minor alarm (set, if non-transi…
1.3.6.1.4.1.9070.1.2.5.7.1.11.1.5Scalartp5000eNotifyTransientread-onlycurrentThe transient state of an alarm or event. It is either a state event (non-transient) or a transient event (transient).
1.3.6.1.4.1.9070.1.2.5.7.1.11.1.6Scalartp5000eNotifyDateTimeread-onlycurrentDate and time of the notification.
1.3.6.1.4.1.9070.1.2.5.7.1.11.1.7Scalartp5000eNotifyDescriptionread-onlycurrentDescription of this alarm or event (from the TP5000 internal alarm/event definition table).
1.3.6.1.4.1.9070.1.2.5.7.1.11.1.8Scalartp5000eNotifyClientAddrread-onlycurrentThe IPv4 address of TP5000's PTP client that generated the notification.
1.3.6.1.4.1.9070.1.2.5.7.1.11.1.9Scalartp5000eNotifySequenceNumread-onlycurrentThe sequence number of a notification. Each notification OID (tp5000TrapAlarm, tp5000TrapEvent, and tp5000ClientNotification) has an independently incrementing…
1.3.6.1.4.1.9070.1.2.5.7.1.11.1.10Scalartp5000eNotifyClientClockIDread-onlycurrentClock ID of the TP5000's PTP client that generated the notification.
1.3.6.1.4.1.9070.1.2.5.7.1.11.2Notificationtp5000eTrapAlarmcurrentTimeProvider 5000 alarm trap for the current notification. It contains the OID and value for module ID, alarm ID, notify index, severity, transient, date and t…
1.3.6.1.4.1.9070.1.2.5.7.1.11.3Notificationtp5000eTrapEventcurrentTimeProvider 5000 event trap for the current notification. It contains the OIDs and values for module ID, event ID, notify index, severity, transient, date and…
1.3.6.1.4.1.9070.1.2.5.7.1.11.4Notificationtp5000eClientNotificationcurrentTimeProvider 5000 PTP client trap for the current client notification. It contains the OID and value for alarm ID, index, severity, transient, date and time an…
1.3.6.1.4.1.9070.1.2.5.7.1.11.5Notificationtp5000ePtpMgmtEventcurrentDescription.
1.3.6.1.4.1.9070.1.2.5.7.1.12Nodetp5000eIPv6GlobalConfig
1.3.6.1.4.1.9070.1.2.5.7.1.12.1TablesnmpIPv4IPv6ManagerTablenot-accessiblecurrentThis table is used to display SNMP manager info, such as managerID, EngineID, manager IP addresses, etc. This table's row only can be added or deleted. The exi…
1.3.6.1.4.1.9070.1.2.5.7.1.12.1.1RowsnmpIPv4IPv6ManagerEntrynot-accessiblecurrentThis is an entry in the Manager table.
1.3.6.1.4.1.9070.1.2.5.7.1.12.1.1.1ColumnsnmpIPv4IPv6ManagerIndexnot-accessiblecurrentA unique value for each user entry. This value ranges should be from 1 to 3.
1.3.6.1.4.1.9070.1.2.5.7.1.12.1.1.2ColumnsnmpIPv4IPv6ManagerIDread-onlycurrentSNMP manager ID or name which is used for SNMP v2 or v3 trap or notification.
1.3.6.1.4.1.9070.1.2.5.7.1.12.1.1.3ColumnsnmpIPv4IPv6ManagerAddressread-writecurrentSNMP manager IP address. It can be IPv4 IPv6
1.3.6.1.4.1.9070.1.2.5.7.1.12.1.1.4ColumnsnmpIPv4IPv6ManagerEngineIDread-onlycurrentThe SNMP management engineID. The format should be 0xDDDDDDDDDDDDDDDD, and minimum length is 14 and maximum length is 32 (including 0x as prefix).
1.3.6.1.4.1.9070.1.2.5.7.1.12.1.1.5ColumnsnmpIPv4IPv6ManagerRowStatusread-writecurrentThe row status of SNMP manager table to control row actions. It has the following actions: The status column has six defined values: - `active(1)', which indic…
1.3.6.1.4.1.9070.1.2.5.7.1.12.2Tabletp5000eIPv4IPv6RemoteSyslogTablenot-accessiblecurrentRemote syslog file control table. It is used to configure a remote syslog server to receive log messages from TP5000K system. Only one remote syslog server is …
1.3.6.1.4.1.9070.1.2.5.7.1.12.2.1Rowtp5000eIPv4IPv6RemoteSyslogEntrynot-accessiblecurrentAn entry of the remote syslog file control table.
1.3.6.1.4.1.9070.1.2.5.7.1.12.2.1.1Columntp5000eIPv4IPv6RemoteSyslogIndexread-onlycurrentThe local index of the remote syslog file control table. At this time only the index value of 1 is supported.
1.3.6.1.4.1.9070.1.2.5.7.1.12.2.1.2Columntp5000eIPv4IPv6RemoteSyslogStateread-writecurrentThe remote syslog state control. The setting can be either Enable (1) or Disable (2). Once this is set to Enable, all TP5000E log messages (intended for any of…
1.3.6.1.4.1.9070.1.2.5.7.1.12.2.1.3Columntp5000eIPv4IPv6RemoteSyslogAddrread-writecurrentThe IP address of the remote syslog machine. It can be IPv4 or IPv6
1.3.6.1.4.1.9070.1.2.5.7.1.12.3Tabletp5000eIPv4IPv6AuthRADIUSTablenot-accessiblecurrentThis table contains IP addresses and access keys for the Radius authentication server. Radius enable state is set in tp5000eRadiusState outside of this table.
1.3.6.1.4.1.9070.1.2.5.7.1.12.3.1Rowtp5000eIPv4IPv6AuthRADIUSEntrynot-accessiblecurrentAn entry of the RADIUS table.
1.3.6.1.4.1.9070.1.2.5.7.1.12.3.1.1Columntp5000eIPv4IPv6AuthRADIUSIndexread-onlycurrentA local index to the RADIUS table. Currently the system only supports RADIUS index value of 1.
1.3.6.1.4.1.9070.1.2.5.7.1.12.3.1.2Columntp5000eIPv4IPv6ServerRADIUSIPAddressread-writecurrentThe RADIUS server's IP address. It can be IPv4 or IPv6. An IP address cannot be set up if authRADIUS key value is none.
1.3.6.1.4.1.9070.1.2.5.7.1.12.3.1.3Columntp5000eIPv4IPv6AuthRADIUSKeyread-writecurrentAuthentication key for RADIUS server access.
1.3.6.1.4.1.9070.1.2.5.7.1.13Identitytp5000eConformancecurrentThis subtree contains conformance statements for the Tp5000e MIB module.
1.3.6.1.4.1.9070.1.2.5.7.1.13.1Nodetp5000eCompliances
1.3.6.1.4.1.9070.1.2.5.7.1.13.1.1Compliancetp5000eBasicCompliancecurrentDescription.
1.3.6.1.4.1.9070.1.2.5.7.1.13.2Nodetp5000eUocGroups
1.3.6.1.4.1.9070.1.2.5.7.1.13.2.1Grouptp5000eLEDGroupcurrentDescription.
1.3.6.1.4.1.9070.1.2.5.7.1.13.2.2Grouptp5000eHWGroupcurrentDescription.
1.3.6.1.4.1.9070.1.2.5.7.1.13.2.3Grouptp5000eModeUpTimeGroupcurrentDescription.
1.3.6.1.4.1.9070.1.2.5.7.1.13.2.4Grouptp5000eModWarmUpGroupcurrentDescription.
1.3.6.1.4.1.9070.1.2.5.7.1.13.2.5Grouptp5000eModStatusGroupcurrentDescription.
1.3.6.1.4.1.9070.1.2.5.7.1.13.2.6Grouptp5000eActiveAlarmGroupcurrentDescription.
1.3.6.1.4.1.9070.1.2.5.7.1.13.2.7Grouptp5000eActiveEventGroupcurrentDescription.
1.3.6.1.4.1.9070.1.2.5.7.1.13.2.8Grouptp5000eAlarmConfigGroupcurrentDescription.
1.3.6.1.4.1.9070.1.2.5.7.1.13.2.9Grouptp5000eGeneralAlarmGroupcurrentDescription.
1.3.6.1.4.1.9070.1.2.5.7.1.13.2.10Grouptp5000eLogFileConfigGroupcurrentDescription.
1.3.6.1.4.1.9070.1.2.5.7.1.13.2.11Grouptp5000eRemoteSyslogGroupcurrentDescription.
1.3.6.1.4.1.9070.1.2.5.7.1.13.2.12Grouptp5000eRedundGroupcurrentDescription.
1.3.6.1.4.1.9070.1.2.5.7.1.13.2.13Grouptp5000eImageGroupcurrentDescription.
1.3.6.1.4.1.9070.1.2.5.7.1.13.2.15Grouptp5000eRebootGroupcurrentDescription.
1.3.6.1.4.1.9070.1.2.5.7.1.13.2.16Grouptp5000eRadiusGroupcurrentDescription.
1.3.6.1.4.1.9070.1.2.5.7.1.13.2.17Grouptp5000eAssetGroupcurrentDescription.
1.3.6.1.4.1.9070.1.2.5.7.1.13.2.18Grouptp5000ePacketServiceGroupcurrentDescription.
1.3.6.1.4.1.9070.1.2.5.7.1.13.2.19Grouptp5000eReferenceStatusGroupcurrentDescription.
1.3.6.1.4.1.9070.1.2.5.7.1.13.2.20Grouptp5000eReferenceConfigGroupcurrentDescription.
1.3.6.1.4.1.9070.1.2.5.7.1.13.2.21Grouptp5000eClockStatusGroupcurrentDescription.
1.3.6.1.4.1.9070.1.2.5.7.1.13.2.22Grouptp5000eClockConfigGroupcurrentDescription.
1.3.6.1.4.1.9070.1.2.5.7.1.13.2.23Grouptp5000eModuleIfGroupcurrentDescription.
1.3.6.1.4.1.9070.1.2.5.7.1.13.2.24Grouptp5000eModuleEntityGroupcurrentDescription.
1.3.6.1.4.1.9070.1.2.5.7.1.13.2.25Grouptp5000eFixedVlanGroupcurrentDescription.
1.3.6.1.4.1.9070.1.2.5.7.1.13.2.26Grouptp5000eNonfixedVlanGroupcurrentDescription.
1.3.6.1.4.1.9070.1.2.5.7.1.13.2.27Grouptp5000eNotifyGroupcurrentDescription.
1.3.6.1.4.1.9070.1.2.5.7.1.13.2.28Grouptp5000eNotificationGroupcurrentDescription.
1.3.6.1.4.1.9070.1.2.5.7.1.13.2.29Grouptp5000eVlanModeGroupcurrentDescription.
1.3.6.1.4.1.9070.1.2.5.7.1.13.2.30Grouptp5000eLastConfigGroupcurrentDescription.
1.3.6.1.4.1.9070.1.2.5.7.1.13.2.31Grouptp5000eIPv6NonfixedVlanGroupcurrentDescription.
1.3.6.1.4.1.9070.1.2.5.7.1.13.2.32Grouptp5000eIPv6FixedVlanGroupcurrentDescription.
1.3.6.1.4.1.9070.1.2.5.7.1.13.2.33Grouptp5000eIPv4IPv6SnmpManagerGroupcurrentElements of tp5000eIPv4IPv6SnmpManagerTable
1.3.6.1.4.1.9070.1.2.5.7.1.13.2.34Grouptp5000eIPv4IPv6RemoteSyslogGroupcurrentElements of tp5000eIPv4IPv6RemoteSyslogTable
1.3.6.1.4.1.9070.1.2.5.7.1.13.2.35Grouptp5000eIPv4IPv6AuthRADIUSGroupcurrentElements of tp5000eIPv4IPv6ServerRADIUSTable
Type Definitions
NameSyntaxStatusDescription
ALARMLEVELTYPEINTEGER { clear(0), critical(2), major(3), minor(4), event(5) }
DateAndTimeOCTET STRING (SIZE (8 | 11))currentA date-time specification. field octets contents range 1 1-2 year* 0..65536 2 3 month 1..12 3 4 day 1..31 4 5 hour 0..23 5 6 minutes 0..59 6 7 seconds 0..60 (use 60 for leap-second) 7 8 deci-seconds 0..9 8 9 direction f…
TAntHeightOCTET STRING (SIZE (4))currentantenna height specification. field octets contents range 1 1 +/- '+' / '-' 2 2-3 meter 0..10000 3 4 meter fraction 0..99 +/- hh.hh
TLatAndLonOCTET STRING (SIZE (5))currentantenna latitude and longitude specification. field octets contents range 1 1 +/-180 deg '+' / '-' 2 2 degree 0..180 3 3 minute 0..59 4 4 second 0..59 5 5 second fraction 0..99 +/- dd:mm:ss.ss
TLocalTimeOffsetOCTET STRING (SIZE (3))currentA local time offset specification. field octets contents range 1 1 direction from UTC '+' / '-' 2 2 hours from UTC* 0..13 3 3 minutes from UTC 0..59 * Notes: - the value of year is in network-byte order - The hours rang…
TP5000IMAGEACTIVEINTEGER { active(1), inactive(2) }
TP5000INTRAIPSETINTEGER { setA(0), setB(1), setC(2) }
TP5000IOCPORTIDINTEGER { eth1(1), eth2(2), none(5) }
TP5000IOPORTIDINTEGER { port1(1), port2(2), port3(3), port4(4), none(5) }
TP5000IOTYPEINTEGER { input(1), output(2) }
TP5000LEDIDINTEGER { bta(1), btb(2), sys(3), alm(4), gpsOrGnss(5), mgmt(6), act(7), alarm(8), eth1(9), eth2(10), holdover(11), ref(12), pwra(13), pwrb(14), shelfPower(15), shelfBatA(16), shelfBatB(17), shelfAlarm(18), shelfMgmt(19), shelfRef(20) }
TP5000LEDTYPEINTEGER { off(0), on(1), red(2), redblink(3), green(4), greenblink(5), amber(6), amberblink(7) }
TP5000PACKETSERVICEINTEGER { ptpGM(1), ptpProbe(2), ntpServer(3), ntpProbe(4) }
TP5000REFQUALIFICATIONINTEGER { disable(0), qualified(1), disqualified(2), selected(3) }
TP5000REFSELECTMODEINTEGER { manual(1), priority(2), ssm(3) }
TP5000REFTIMINGMODEINTEGER { time(1), frequency(2) }
TP5000SERVOCTLINTEGER { warmup(1), freerun(2), fasttrack(3), normaltrack(4), holdover(5), bridge(6), fail(7), offline(8), extHoldover(9), localFreerun(10), localHoldover(11) }
TP5000SSMOPTIONINTEGER { option1(1), option2(2) }
TP5000SSMVALUEINTEGER (1..15)
TP5000TRANSIENTINTEGER { stateEvent(0), transientEvent(1) }
TSsmINTEGER (0..255)currentThe ssm hex code