MIB Viewer

TY1250I-MIB

120 objects
No module-level DESCRIPTION found.
OIDNameAccessStatusDescription
1.3.6.1.4.1.466Nodetylink
1.3.6.1.4.1.466.1Nodedsucsu
1.3.6.1.4.1.466.2Nodetyview
1.3.6.1.4.1.466.3Nodety1250
1.3.6.1.4.1.466.3.0Nodety1250TrapA ty1250Trap trap signifies that the sending node had its `ty1250AlarmType` variable modified.
1.3.6.1.4.1.466.3.1Nodety1250LineFailureTrapThe line has failed.
1.3.6.1.4.1.466.3.1Nodety1250SysTable
1.3.6.1.4.1.466.3.1.1Scalarty1250SysTyperead-onlymandatoryA textual description of the system model identifier. for example: TYLINK1250
1.3.6.1.4.1.466.3.1.2Scalarty1250SysSoftRevread-onlymandatoryDisplays the Software Revision installed in this node.
1.3.6.1.4.1.466.3.1.3Scalarty1250SysHardRevread-onlymandatoryDisplays the Hardware Revision of the node.
1.3.6.1.4.1.466.3.1.4Scalarty1250SysNumNetInstalledread-onlymandatoryThe number of Network (DDS) ports that are installed. There is 1 on the 1250.
1.3.6.1.4.1.466.3.1.5Scalarty1250SysNumDteInstalledread-onlymandatoryThe number of channels (DTE) that are installed. There is 1 on the 1250.
1.3.6.1.4.1.466.3.1.6Scalarty1250SysNumMaintInstalledread-onlymandatoryThe number of Maintenance ports that are installed. There are 2 on the 1250.
1.3.6.1.4.1.466.3.1.7Scalarty1250SysNameread-writemandatoryThe user supplied name of the node. This object does not affect operation, but may be useful for network management.
1.3.6.1.4.1.466.3.2Nodety1250CfgAppTable
1.3.6.1.4.1.466.3.2Nodety1250LineInServiceTrapThe line is back in service.
1.3.6.1.4.1.466.3.2.2Scalarty1250CfgAppClockSourceread-writemandatoryDefault timing, or clock, source. There must be only one source on a DDS line. Node should always be network (2) timed on a point-to-network application. Line …
1.3.6.1.4.1.466.3.2.3Scalarty1250CfgAppCircuitIdread-writemandatoryCircuit identifier provided by the service provider.
1.3.6.1.4.1.466.3.3Nodety1250CfgNetTable
1.3.6.1.4.1.466.3.3Nodety1250ConnectedTrapThe 1250 unit is connected.
1.3.6.1.4.1.466.3.3.4Scalarty1250CfgNetGlareTyperead-writemandatoryIn switched applications, defines who wins when there are simultanious incomming and outgoing calls. If in doubt, select external-glare (2).
1.3.6.1.4.1.466.3.3.5Scalarty1250CfgNetEchoCanread-writemandatoryIn switched applications, some carriers, such as Sprint, require you to disable-echo-cancellors (2) for data apps on most lines. Calls take longer to come up w…
1.3.6.1.4.1.466.3.3.6Scalarty1250CfgNetAnsModeread-writemandatoryIn switched applications, allows for manual-answer (1) or automatic-answer (2) of inbound calls. Calls may be answered in manual mode via vt100, DTR, or the fr…
1.3.6.1.4.1.466.3.3.7Scalarty1250CfgNetDialTimeoutread-writemandatoryIn switched applications, time in seconds to wait for far end to answer before giving up, and possibly redialing.
1.3.6.1.4.1.466.3.3.8Scalarty1250CfgNetNumRedialread-writemandatoryIn switched applications, number of times to redial if the call fails.
1.3.6.1.4.1.466.3.3.9Scalarty1250CfgNetRedialDelayread-writemandatoryIn switched applications, delay in seconds between redial attempts.
1.3.6.1.4.1.466.3.3.10Scalarty1250CfgNetDefNum2Dialread-writemandatoryIn switched applications, default phone number to dial. Numbers and dashes are allowed.
1.3.6.1.4.1.466.3.3.11Scalarty1250CfgNetTyperead-writemandatoryIndicates type of service purchased on the attached network line (DDS or SW56). Valid selections are dedicated (1) and switch56 (2).
1.3.6.1.4.1.466.3.3.12Scalarty1250CfgNetBPVThresholdingread-writemandatoryAllows the user to turn on and off the BPV thresholding function. Valid values are thresholding_at_10E-4 (1) and disable-thresholding (2).
1.3.6.1.4.1.466.3.4Nodety1250CfgDteTable
1.3.6.1.4.1.466.3.4Nodety1250ConnectFailureTrapThe attempted connection failed.
1.3.6.1.4.1.466.3.4.1Scalarty1250CfgDteTyperead-onlymandatoryThe Dte channel type identifies the electrical specification of the interface. Read-only.
1.3.6.1.4.1.466.3.4.5Scalarty1250CfgDteClockInvertread-writemandatoryClock Inversion, invert-dte-clock (2), can be used to solve out of phase timing problems on DTE link. normal-dte-clock (1) can be used in most cases.
1.3.6.1.4.1.466.3.4.6Scalarty1250CfgDteTimingread-writemandatoryThe DTE channel Timing mode. Use loop2-timing (2) when in doubt.
1.3.6.1.4.1.466.3.5Nodety1250CfgDialTable
1.3.6.1.4.1.466.3.5Nodety1250IncomingCallTrapIncoming call.
1.3.6.1.4.1.466.3.5.1Scalarty1250CfgDialButtonread-writemandatoryIn switched applications, Enables/Disables the button on front of unit. This button can used to manual answer an incomming call, or dial out the default number…
1.3.6.1.4.1.466.3.5.2Scalarty1250CfgDialDtrread-writemandatoryIn switched applications, Enables/Disables dialing on DTR signal transition. Valid values enable-dtr (1) and disable-dtr (2).
1.3.6.1.4.1.466.3.5.3Scalarty1250CfgDialRtsDiscread-writemandatoryIn switched applications, Enables/Disables disconnecting on RTS signal transition. Valid values are enable-rts (1) and disable-rts (2).
1.3.6.1.4.1.466.3.5.4Scalarty1250CfgDialRiread-writemandatoryIn switched applications, Enables/Disables incoming call notification to DTE via RI signal. Valid values are enable-ri (1) and disable-ri (2).
1.3.6.1.4.1.466.3.6Tablety1250CfgMaintTablenot-accessiblemandatoryThe Maintenance Port Configuration table contains parameters for the Maintenance ports on the 1250. The Terminal Port is Index=1; SLIP port is 2
1.3.6.1.4.1.466.3.6Nodety1250DisconnectedTrapDisconnected.
1.3.6.1.4.1.466.3.6.1Rowty1250CfgMaintEntrynot-accessiblemandatoryMaintenance Port Configuration Object
1.3.6.1.4.1.466.3.6.1.1Columnty1250CfgMaintIndexread-onlymandatoryThe Maintenance port under consideration. On the 1250, the Terminal Port is Index=1; SLIP port is 2.
1.3.6.1.4.1.466.3.6.1.2Columnty1250CfgMaintModeread-writemandatoryThe Mode for this Maintenance Port. Values include ascii-vt100 (4), slip (7), and cslip (8).
1.3.6.1.4.1.466.3.6.1.3Columnty1250CfgMaintBaudread-writemandatoryBaud rate for this Maintenance port. Values are baud-2400 (2), baud-9600 (4), baud-19200 (5).
1.3.6.1.4.1.466.3.6.1.4Columnty1250CfgMaintDataBitsread-writemandatoryDatabits for this Maintenance port. Values are databits-7 (1) and databits-8 (2).
1.3.6.1.4.1.466.3.6.1.5Columnty1250CfgMaintStopBitsread-writemandatoryNumber of Stopbits for this Maintenance port. Values are stopbits-1 (1), stopbits-1-5 (2), and stopbits-2 (3).
1.3.6.1.4.1.466.3.6.1.6Columnty1250CfgMaintParityread-writemandatoryParity for this Maintenance port. Values are no-parity (1), odd-parity (2), even-parity (3).
1.3.6.1.4.1.466.3.6.1.7Columnty1250CfgMaintFlowCtrlread-writemandatoryFlow Control for this Maintenance port. Values are no-flow-control (1), software-flow-control (2), and hardware-flow-control (3).
1.3.6.1.4.1.466.3.7Nodety1250BadConfigTrapThe configuration specified in the SET command was bad. SET failed.
1.3.6.1.4.1.466.3.8Nodety1250CfgSlipTable
1.3.6.1.4.1.466.3.8Nodety1250LocalConfigTrapThe configuration has been changed by a means other than SNMP.
1.3.6.1.4.1.466.3.8.1Scalarty1250CfgSlipMyIPread-writemandatoryThe IP address for this node.
1.3.6.1.4.1.466.3.8.2Scalarty1250CfgSlipPeerIPread-writemandatoryThe IP address for other end of slip connection.
1.3.6.1.4.1.466.3.8.3Scalarty1250CfgSlipMaskread-writemandatoryThe IP Network Mask (eg 255.255.255.0) for the SLIP link.
1.3.6.1.4.1.466.3.8.4Scalarty1250CfgSlipMaxMTUread-writemandatoryThe Maximum Transmission Unit is the size of the largest IP packet supported. This value should be set to the lowest value supported by any equipment in the tr…
1.3.6.1.4.1.466.3.9Nodety1250BPVThresholdExceededTrapBPV threshold exceeded.
1.3.6.1.4.1.466.3.9Nodety1250CallTable
1.3.6.1.4.1.466.3.9.1Scalarty1250CallStatusread-onlymandatoryThe call status is shown here.
1.3.6.1.4.1.466.3.9.2Scalarty1250CallNumberread-writemandatoryThe last phone number dialed out.
1.3.6.1.4.1.466.3.9.3Scalarty1250CallUpTimeread-onlymandatoryNumber of seconds the call has been up.
1.3.6.1.4.1.466.3.9.4Scalarty1250CallStatewrite-onlymandatoryCall-related actions: a: Connect (initiate a call), b: Disconnect (terminate a call) c: Answer (answer an incoming call).
1.3.6.1.4.1.466.3.10Nodety1250BPVThresholdAcceptableTrapBPV threshold acceptable.
1.3.6.1.4.1.466.3.10Nodety1250DiagUnitTable
1.3.6.1.4.1.466.3.10.1Scalarty1250DiagUnitLocLoopread-writemandatoryEnables the operator to control and examine the UNIT local loopback. This loopback occurs on all network ports transmit and receive logic. The unit will transm…
1.3.6.1.4.1.466.3.10.2Scalarty1250DiagUnitResetwrite-onlymandatoryEnables the operator to remotely reset the unit. Using this command will cause the unit to terminate all its connections and drop data.
1.3.6.1.4.1.466.3.11Nodety1250DiagNetTable
1.3.6.1.4.1.466.3.11Nodety1250LocalUnitLoopbackEnabledTrapLocal unit loopback enabled.
1.3.6.1.4.1.466.3.11.1Scalarty1250DiagNetLineStatusread-onlymandatoryThe Current status of the physical interface. Your network carrier can send Out-of-Service or Maintenance Mode codes.
1.3.6.1.4.1.466.3.11.2Scalarty1250DiagNetLclLpbkread-writemandatoryEnables the operator to control and examine the network local loopback. This loopback occurs on the net side of the local transmit and receive logic. The unit …
1.3.6.1.4.1.466.3.11.3Scalarty1250DiagNetRmtLpbkread-onlymandatoryEnables the operator to examine (ONLY) the status of network loopbacks placed by external equipment, such as your local CO. These loopbacks will loop received …
1.3.6.1.4.1.466.3.12Nodety1250DiagDteTable
1.3.6.1.4.1.466.3.12Nodety1250LocalUnitLoopbackDisabledTrapLocal unit loopback disabled.
1.3.6.1.4.1.466.3.12.1Scalarty1250DiagDteSigRTSread-onlymandatoryThe Dte Channel RTS signal. Values are rts-signal-on (1) and rts-signal-off (2).
1.3.6.1.4.1.466.3.12.2Scalarty1250DiagDteSigDTRread-onlymandatoryThe Dte Channel DTR signal. Values are dtr-signal-on (1) and dtr-signal-off (2).
1.3.6.1.4.1.466.3.12.5Scalarty1250DiagDteLclLpbkread-writemandatoryThis selection displays the status or controls the Local DTE Channel Loopback for the selected channel. This is will loop DTE data back towards the DTE interfa…
1.3.6.1.4.1.466.3.12.6Scalarty1250DiagDteV54Lpbkread-onlymandatoryThis selection displays the status of the DTE Channel V.54 Loopback for the channel. This loopback is initiated by the remote node, causing this node to loop d…
1.3.6.1.4.1.466.3.12.7Scalarty1250DiagDteBerStatewrite-onlymandatoryBERT test related actions: a: Starts a BERT test on a channel, b: Stops a BERT test on a channel, c: Inject Errors while the BERT test is running, d: Clears BE…
1.3.6.1.4.1.466.3.12.8Scalarty1250DiagDteBerStatusread-onlymandatoryDisplays the current BERT test sync status.
1.3.6.1.4.1.466.3.12.9Scalarty1250DiagDteBerErrorsread-onlymandatoryDisplays the number of errors detected in Bert Test.
1.3.6.1.4.1.466.3.12.10Scalarty1250DiagDteBerErrSecread-onlymandatoryDisplays the number of seconds containing errors in BERT Test.
1.3.6.1.4.1.466.3.12.11Scalarty1250DiagDteBerTimeElapsread-onlymandatoryElapsed time since BERT test was started or cleared.
1.3.6.1.4.1.466.3.12.12Scalarty1250DiagDteBerResyncsread-onlymandatoryDisplays the number of times BERT test has synched up on the pattern.
1.3.6.1.4.1.466.3.12.13Scalarty1250DiagDteRmtV54Lpbkwrite-onlymandatoryThis selection controls the DTE Channel V.54 Remote Loopback. Transmit-code-enable (3) will cause the node to transmit a V.54 code to the remote node which wil…
1.3.6.1.4.1.466.3.13Scalarty1250AlarmTyperead-onlymandatoryThe type of alarms that are generated on the node
1.3.6.1.4.1.466.3.13Nodety1250LocalNetLoopbackEnabledTrapLocal network loopback enabled.
1.3.6.1.4.1.466.3.14Nodety1250CfgSnmpTable
1.3.6.1.4.1.466.3.14Nodety1250LocalNetLoopbackDisabledTrapLocal network loopback disabled.
1.3.6.1.4.1.466.3.14.1Scalarty1250CfgSnmpManagerIPread-writemandatoryThe IP address for the SNMP manager to receive this node's TRAPs.
1.3.6.1.4.1.466.3.15Nodety1250SimplexCurrentLoopbackEnabledTrapSimplex current loopback enabled.
1.3.6.1.4.1.466.3.15Nodety1250StatsDteTable
1.3.6.1.4.1.466.3.15.1Scalarty1250StatsDteTxByteCountread-onlymandatoryThe statistic counting the number of bytes transmitted on the DTE channel.
1.3.6.1.4.1.466.3.15.2Scalarty1250StatsDteRxByteCountread-onlymandatoryThe statistic counting the number of bytes received on the DTE channel.
1.3.6.1.4.1.466.3.15.3Scalarty1250StatsDteClearStatswrite-onlymandatoryAllows the user to zero out all the statistics in the DTE statistics table.
1.3.6.1.4.1.466.3.16Nodety1250SimplexCurrentLoopbackDisabledTrapSimplex current loopback disabled.
1.3.6.1.4.1.466.3.16Nodety1250StatsNetTable
1.3.6.1.4.1.466.3.16.1Scalarty1250StatsNetLoopLengthread-onlymandatoryThe statistic that estimates line attentuation on the network channel.
1.3.6.1.4.1.466.3.16.2Scalarty1250StatsNetBpvCountread-onlymandatoryThe statistic counting the number of BPV errors on the network channel.
1.3.6.1.4.1.466.3.16.3Scalarty1250StatsNetTxByteCountread-onlymandatoryThe statistic counting the number of bytes transmitted on the network channel.
1.3.6.1.4.1.466.3.16.4Scalarty1250StatsNetRxByteCountread-onlymandatoryThe statistic counting the number of bytes received on the network channel.
1.3.6.1.4.1.466.3.16.5Scalarty1250StatsNetClearStatswrite-onlymandatoryAllows the user to zero out all the statistics in the network statistics table.
1.3.6.1.4.1.466.3.17Nodety1250CfgTelnetTable
1.3.6.1.4.1.466.3.17Nodety1250NonLatchingLoopbackEnabledTrapNonlatching loopback enabled.
1.3.6.1.4.1.466.3.17.1Scalarty1250CfgTelnetEnableread-writemandatoryEnables/Disables the telnet feature. Valid values are enable-telnet (1) and disable-telnet (2).
1.3.6.1.4.1.466.3.17.2Scalarty1250CfgTelnetAutoLogOutread-writemandatoryEnables/Disables the telnet auto-logout, logging out the user after a certain length of idle time. Valid values are autologout-at-15-minutes (1) and disable-au…
1.3.6.1.4.1.466.3.18Nodety1250NonLatchingLoopbackDisabledTrapNonlatching loopback disabled.
1.3.6.1.4.1.466.3.19Nodety1250V54LoopUpInitiatedTrapStarting to loop up a V54 loopback on the remote unit.
1.3.6.1.4.1.466.3.20Nodety1250V54LoopDownCompletedTrapCompleted the loop down of a V54 loopback on the remote unit.
1.3.6.1.4.1.466.3.21Nodety1250V54LoopbackEnabledTrapV54 loopback enabled by remote unit.
1.3.6.1.4.1.466.3.22Nodety1250V54LoopbackDisabledTrapV54 loopback disabled by remote unit.
1.3.6.1.4.1.466.3.23Nodety1250BertInitiatedTrapBERT test pattern initiated.
1.3.6.1.4.1.466.3.24Nodety1250BertCompletedTrapBERT test pattern completed.
1.3.6.1.4.1.466.3.25Nodety1250LocalDteLoopbackEnabledTrapLocal DTE loopback enabled.
1.3.6.1.4.1.466.3.26Nodety1250LocalDteLoopbackDisabledTrapLocal DTE loopback disabled.
1.3.6.1.4.1.466.3.27Nodety1250LocalUnitLoopbackFailedTrapUnable to do a local unit loopback.
1.3.6.1.4.1.466.3.28Nodety1250LocalNetLoopbackFailedTrapUnable to do a local network loopback.
1.3.6.1.4.1.466.3.29Nodety1250BertFailedTrapUnable to do a BERT.
1.3.6.1.4.1.466.3.30Nodety1250LocalDteLoopbackFailedTrapUnable to do a local DTE loopback.
1.3.6.1.4.1.466.3.31Nodety1250V54LoopbackFailedTrapUnable to do a V54 loopback.