UBQS-AFSMGR-MIB

122 objects
AFSMGR Event Group
OIDNameAccessStatusDescription
1.3.6.1.4.1.7800.100.7IdentityubiAFSMGREventMIBAFSMGR Event Group
1.3.6.1.4.1.7800.100.7.1TablecurrentAlarmTablenot-accessiblecurrentDescription.
1.3.6.1.4.1.7800.100.7.1.1RowcurrentAlarmEntrynot-accessiblecurrentDescription.
1.3.6.1.4.1.7800.100.7.1.1.1ColumnalarmIndexread-onlycurrentcurrent Alarm index.
1.3.6.1.4.1.7800.100.7.1.1.2ColumnalarmIdread-onlycurrentDescription
1.3.6.1.4.1.7800.100.7.1.1.3ColumnalarmTyperead-onlycurrentDescription 1 : equipment 2 : communications 3 : QoS 4 : processing 5 : environment
1.3.6.1.4.1.7800.100.7.1.1.4ColumnalarmSeverityread-onlycurrentDescription 1 : critical 2 : major 3 : minor 4 : warning 5 : indeterminate
1.3.6.1.4.1.7800.100.7.1.1.5ColumnalarmPhysicalLocread-onlycurrentDescription
1.3.6.1.4.1.7800.100.7.1.1.6ColumnalarmLogicalLocread-onlycurrentDescription
1.3.6.1.4.1.7800.100.7.1.1.7ColumnalarmCurStatusread-onlycurrentDescription
1.3.6.1.4.1.7800.100.7.1.1.8ColumnalarmAuxinforead-onlycurrentDescription
1.3.6.1.4.1.7800.100.7.1.1.9ColumnalarmDateTimeread-onlycurrentDescription
1.3.6.1.4.1.7800.100.7.1.1.10ColumnalarmStatusread-onlycurrentDescription
1.3.6.1.4.1.7800.100.7.2TableeventLogTablenot-accessiblecurrentDescription.
1.3.6.1.4.1.7800.100.7.2.1RoweventLogEntrynot-accessiblecurrentDescription.
1.3.6.1.4.1.7800.100.7.2.1.1ColumneventIndexread-onlycurrentDescription
1.3.6.1.4.1.7800.100.7.2.1.2ColumneventIdread-onlycurrentDescription
1.3.6.1.4.1.7800.100.7.2.1.3ColumneventTyperead-onlycurrentDescription 1 : equipment 2 : communications 3 : QoS 4 : processing 5 : environment
1.3.6.1.4.1.7800.100.7.2.1.4ColumneventSeverityread-onlycurrentDescription 1 : critical 2 : major 3 : minor 4 : warning 5 : indeterminate
1.3.6.1.4.1.7800.100.7.2.1.5ColumneventValueread-onlycurrentDescription
1.3.6.1.4.1.7800.100.7.2.1.6ColumneventDateTimeread-onlycurrentDescription
1.3.6.1.4.1.7800.100.7.2.1.7ColumneventStatusread-onlycurrentDescription
1.3.6.1.4.1.7800.100.7.3NodeafsmgrEventManagerTrap
1.3.6.1.4.1.7800.100.7.3.1NotificationsysWarmStartNoticurrentSystem Warm-Start Notification.
1.3.6.1.4.1.7800.100.7.3.2NotificationsysColdStartNoticurrentSystem Cold-Start Notification.
1.3.6.1.4.1.7800.100.7.3.3NotificationlinkUpNoticurrentLink Up Notification.
1.3.6.1.4.1.7800.100.7.3.4NotificationlinkDownNoticurrentLink Down Notification.
1.3.6.1.4.1.7800.100.7.3.5NotificationcpuOverloadFallingNoticurrentCPU Overload Falling Notification.
1.3.6.1.4.1.7800.100.7.3.6NotificationcpuOverloadRisingNoticurrentCPU Overload Rising Notification.
1.3.6.1.4.1.7800.100.7.3.7NotificationgbicOperNoticurrentGbic Equip/Unequip Operation Notification.
1.3.6.1.4.1.7800.100.7.3.8NotificationmemoryOverloadNoticurrentMemory Overload Notification.
1.3.6.1.4.1.7800.100.7.3.9NotificationslotOperNoticurrentSlot Equip/Unequip Operation Notification.
1.3.6.1.4.1.7800.100.7.3.10NotificationtempLowNoticurrentTemperature Low Alarm Notification.
1.3.6.1.4.1.7800.100.7.3.11NotificationtempHighNoticurrentTemperature High Alarm Notification.
1.3.6.1.4.1.7800.100.7.3.12NotificationfanAlarmNoticurrentFan Alarm Notification.
1.3.6.1.4.1.7800.100.7.3.13NotificationfmuEquipStatusNoticurrentFan Module Unit Equip/Unequip Status Notification.
1.3.6.1.4.1.7800.100.7.3.14NotificationpsuAlarmNoticurrentPower Alarm Notification.
1.3.6.1.4.1.7800.100.7.3.15NotificationpsuEquipStatusNoticurrentPower Supply Unit Equip/Unequip Status Notification.
1.3.6.1.4.1.7800.100.7.3.16NotificationportAdminNoticurrentPort Administration Status Notification.
1.3.6.1.4.1.7800.100.7.3.17NotificationfanOperStatusNoticurrentFan Operational Status Notification.
1.3.6.1.4.1.7800.100.7.3.18NotificationrmonRisingNoticurrentRmon Rising Notification.
1.3.6.1.4.1.7800.100.7.3.19NotificationrmonFallingNoticurrentRmon Falling Notification.
1.3.6.1.4.1.7800.100.7.3.20NotificationportSLDNoticurrentPort Self-Loop Detection Notification.
1.3.6.1.4.1.7800.100.7.3.30NotificationremoteConnectioncurrentRemote connection Notification.
1.3.6.1.4.1.7800.100.7.3.41NotificationponDriftWindowNoticurrentOnu Drift Window Notification.
1.3.6.1.4.1.7800.100.7.3.42NotificationponGemChannelLossNoticurrentLoss of GEM channel delineation Notification.
1.3.6.1.4.1.7800.100.7.3.43NotificationponAckLossNoticurrentLoss of acknowledge with ONUi Notification.
1.3.6.1.4.1.7800.100.7.3.44NotificationponSigDegradeNoticurrentSignal Degraded of ONUi Notification.
1.3.6.1.4.1.7800.100.7.3.45NotificationponSigFailNoticurrentSignal Fail of ONUi Notification.
1.3.6.1.4.1.7800.100.7.3.46NotificationponPhysEquipErrNoticurrentPhysical Equipment Error of ONUi Notification.
1.3.6.1.4.1.7800.100.7.3.47NotificationponKeySyncLossNoticurrentLoss of Key sync with ONUi Notification.
1.3.6.1.4.1.7800.100.7.3.48NotificationponTransIfWarmNoticurrentTransmission Interference Warning Notification.
1.3.6.1.4.1.7800.100.7.3.49NotificationponTransIfAlarmNoticurrentTransmission Interference Alarm Notification.
1.3.6.1.4.1.7800.100.7.3.50NotificationponRemoDefectIndNoticurrentRemote Defect Indication of ONUi Notification.
1.3.6.1.4.1.7800.100.7.3.51NotificationonuOperStatusNoticurrentOnu Operation Status Notification.
1.3.6.1.4.1.7800.100.7.3.52NotificationoltAlarmNoticurrentOlt Alarm Notification.
1.3.6.1.4.1.7800.100.7.3.53NotificationoltLinkFaultNoticurrentOlt Link Fault Notification.
1.3.6.1.4.1.7800.100.7.3.54NotificationontDyingGaspNoticurrentOnt Dying Gasp Notification.
1.3.6.1.4.1.7800.100.7.3.55NotificationponLinkStatusNoticurrentPon Link Status Notification.
1.3.6.1.4.1.7800.100.7.3.57NotificationlinkLoopbackTestNoticurrentLink Loopback Test Notification.
1.3.6.1.4.1.7800.100.7.3.68NotificationponOltOperStatusNoticurrentPon Olt Oper Status Notification.
1.3.6.1.4.1.7800.100.7.3.69NotificationponOltAdminStatusNoticurrentPon Olt Administrator Status Notification.
1.3.6.1.4.1.7800.100.7.3.70NotificationponOnuAdminStatusNoticurrentOnu Admin Status Notification.
1.3.6.1.4.1.7800.100.7.3.71NotificationponOnuRegisterSubMacNoticurrentOnu Subscriber Mac Registration Notification.
1.3.6.1.4.1.7800.100.7.3.73NotificationlinkLoopbackTestFailNoticurrentLink Loopback Test Fail Notification.
1.3.6.1.4.1.7800.100.7.3.93NotificationponOnuRegOverloadNoticurrentPon Onu Register Overload Notification. (onu too many registration)
1.3.6.1.4.1.7800.100.7.3.96NotificationponLinkRegNoticurrentPon Link Register Notification.
1.3.6.1.4.1.7800.100.7.3.97NotificationponOnuLoopDetectNoticurrentOnu Loop Detect Notification.
1.3.6.1.4.1.7800.100.7.3.98NotificationponOltImageUpgrageNoticurrentOlt Image Upgrade Notification.
1.3.6.1.4.1.7800.100.7.3.99NotificationponOltImageUpgrageFailNoticurrentOlt Image Upgrade Fail Notification.
1.3.6.1.4.1.7800.100.7.3.100NotificationonuImageUpgradeNoticurrentONU Image Upgrade Notification.
1.3.6.1.4.1.7800.100.7.3.101NotificationonuImageUpgradeFailNoticurrentONU Image Upgrade Fail Notification.
1.3.6.1.4.1.7800.100.7.3.102NotificationonuLdShutdownNoticurrentONU LD shutdown Notification.
1.3.6.1.4.1.7800.100.7.3.103NotificationponUnadminMacRegNoticurrentUnadmin Mac-address Register Notification.
1.3.6.1.4.1.7800.100.7.3.104NotificationponDupMacRegNoticurrentDuplicated Mac-address Register Notification.
1.3.6.1.4.1.7800.100.7.3.105NotificationponOnuTypeMismatchNoticurrentOnu Type Mismatch Notification.
1.3.6.1.4.1.7800.100.7.3.106NotificationponOltDyingGaspNoticurrentPon Olt DyingGasp Notification.
1.3.6.1.4.1.7800.100.7.3.107NotificationponOltCableDownNoticurrentOlt Cable Down Notification.
1.3.6.1.4.1.7800.100.7.3.108NotificationponPMCcrc32MonitorNoticurrentPMC CRC32 Monitor Notification.
1.3.6.1.4.1.7800.100.7.3.109NotificationimageUpDownloadStatusNoticurrentImage Up/Download Status Notification.
1.3.6.1.4.1.7800.100.7.3.110NotificationimageUpDownloadFailNoticurrentImage Up/Download Fail Notification.
1.3.6.1.4.1.7800.100.7.3.111NotificationconfigUpDownloadStatusNoticurrentConfig Up/Download Status Notification.
1.3.6.1.4.1.7800.100.7.3.112NotificationsysRebootMaxTempNoticurrentSystem Reboot by Max Temperature Notification.
1.3.6.1.4.1.7800.100.7.3.113NotificationponRogueOnuLdShutdowncurrentRogue Onu Ld Shutdown Notification.
1.3.6.1.4.1.7800.100.7.3.114NotificationscuOperStatusNoticurrentSCU Operation Status Notification.
1.3.6.1.4.1.7800.100.7.3.115NotificationconfigUpDownloadFailNoticurrentConfig Up/Download Fail Notification.
1.3.6.1.4.1.7800.100.7.3.116NotificationponOntRxPowerStatusNoticurrentPon Ont Rx-optical-alarm Notification.
1.3.6.1.4.1.7800.100.7.3.117NotificationponOltRxPowerStatusNoticurrentPon Olt Rx-optical-alarm Notification.
1.3.6.1.4.1.7800.100.7.3.118NotificationponOntTxPowerStatusNoticurrentPon Ont Tx-optical-alarm Notification.
1.3.6.1.4.1.7800.100.7.3.119NotificationponOntTemperatureStatusNoticurrentPon Ont Temperature-alarm Notification.
1.3.6.1.4.1.7800.100.7.3.120NotificationponOntVoltageStatusNoticurrentPon Ont Voltage-alarm Notification.
1.3.6.1.4.1.7800.100.7.3.121NotificationponOntBiasStatusNoticurrentPon Ont Bias-alarm Notification.
1.3.6.1.4.1.7800.100.7.3.122NotificationponOltRedSlaveFaultNoticurrentPon Olt Redundancy Slave Link Fault Notification.
1.3.6.1.4.1.7800.100.7.3.123NotificationponOltRedSwitchoverNoticurrentPon Olt Redundancy Switchover Notification.
1.3.6.1.4.1.7800.100.7.3.124NotificationponOnuOpticRxPowerOnusNoticurrentPon Onus Low Optic Rx Power Notification.
1.3.6.1.4.1.7800.100.7.3.127NotificationponOnuDownThresholdNoticurrentPon Onu Down Threshold Notification.
1.3.6.1.4.1.7800.100.7.3.128NotificationponOnuFanStatusNoticurrentPon Onu Fan Status Notification.
1.3.6.1.4.1.7800.100.7.3.129NotificationexternalACAlarmcurrentExternal AC alarm
1.3.6.1.4.1.7800.100.7.3.130NotificationexternalUnitAlarmcurrentExternal unit alarm.
1.3.6.1.4.1.7800.100.7.3.131NotificationponLoopCntThresholdNoticurrentLoop-Count-Threshold-alarm Notification.
1.3.6.1.4.1.7800.100.7.3.132NotificationscuUnequipNoticurrentscu unequip alarm
1.3.6.1.4.1.7800.100.7.3.133NotificationliuUnequipNoticurrentliu unequip alarm
1.3.6.1.4.1.7800.100.7.3.134NotificationfmuUnequipNoticurrentfmu unequip alarm
1.3.6.1.4.1.7800.100.7.3.135NotificationponOltLineCodeErrorMonitorNoticurrentOLT line code errors monitor Notification
1.3.6.1.4.1.7800.100.7.3.136NotificationponOltAlignmentErrorMonitorNoticurrentOLT alignment errors monitor Notification
1.3.6.1.4.1.7800.100.7.3.137NotificationscuEjectorAlarmNoticurrentSCU ejector alarm Notification
1.3.6.1.4.1.7800.100.7.3.138NotificationsystemCheckAlarmcurrentEMS System Check Monitor Notification
1.3.6.1.4.1.7800.100.7.3.139NotificationponOnuRegThreshOverNoticurrentPon Onu Registration Threshold Over Notification
1.3.6.1.4.1.7800.100.7.3.140NotificationdcTempHighNoticurrentDc Board Temperature High Threshold Notification
1.3.6.1.4.1.7800.100.7.3.141NotificationdcTempLowNoticurrentDc Board Temperature Low Threshold Notification
1.3.6.1.4.1.7800.100.7.3.142NotificationhumidityHighNoticurrentMainboard Humidity High Threshold Notification
1.3.6.1.4.1.7800.100.7.3.143NotificationhumidityLowNoticurrentMainboard Humidity Low Threshold Notification
1.3.6.1.4.1.7800.100.7.3.144NotificationdcHumidityHighNoticurrentDc Board Humidity High Threshold Notification
1.3.6.1.4.1.7800.100.7.3.145NotificationdcHumidityLowNoticurrentDc Board Humidity Low Threshold Notification
1.3.6.1.4.1.7800.100.7.3.146NotificationsysRebootMaxDcTempNoticurrentSystem Reboot by Max Dc Board Temperature Notification.
1.3.6.1.4.1.7800.100.7.3.147NotificationsysRebootMaxHumidNoticurrentSystem Reboot by Max Humidity Notification.
1.3.6.1.4.1.7800.100.7.3.148NotificationsysRebootMaxDcHumidNoticurrentSystem Reboot by Max Dc Board Humidity Notification.
1.3.6.1.4.1.7800.100.7.3.149NotificationfanSpeedHighNoticurrentFan Speed High Notification.
1.3.6.1.4.1.7800.100.7.3.150NotificationpsuUnequipNoticurrentPsu Unequip Notification.
1.3.6.1.4.1.7800.100.7.3.151NotificationdoorOpenAlarmNoticurrentDoor Open Monitor Notification
1.3.6.1.4.1.7800.100.7.3.152NotificationexternalMajorAlarmcurrentExternal Power Major Alarm.
1.3.6.1.4.1.7800.100.7.3.157Notificationpiu10gFanFailAlarmcurrent10G PIU Fan Fail Alarm.