MIB Viewer

USR-GWCBSP-MIB

33 objects
The commWorks enterprise defined MIB objects for the GWC BSP specific platform
Imported Objects
SNMPv2-SMIInteger32 IpAddress MODULE-IDENTITY OBJECT-TYPE
USR-DEFINITIONS-MIBcommon UsrConfigStatus UsrDisplayString
OIDNameAccessStatusDescription
1.3.6.1.4.1.429.4.38IdentityusrGWCBSPThe commWorks enterprise defined MIB objects for the GWC BSP specific platform
1.3.6.1.4.1.429.4.38.1ScalarusrGWCBSPProductCoderead-onlycurrentThe Code number assigned for the product
1.3.6.1.4.1.429.4.38.2ScalarusrGWCBSPHWVersionread-onlycurrentHardware version number
1.3.6.1.4.1.429.4.38.3ScalarusrGWCBSPSerialNumberread-onlycurrentSerial number of the product
1.3.6.1.4.1.429.4.38.4ScalarusrGWCBSPCardIDread-onlycurrentAssigned card ID
1.3.6.1.4.1.429.4.38.5ScalarusrGWCBSPFeatureKeyread-onlycurrentBitmap of the features supported in the product
1.3.6.1.4.1.429.4.38.6ScalarusrGWCBSPNICIDread-onlycurrentNIC card Identifier
1.3.6.1.4.1.429.4.38.7ScalarusrGWCBSPNICNameread-onlycurrentNIC card name
1.3.6.1.4.1.429.4.38.8ScalarusrGWCBSPNACIDread-onlycurrentNAC card Identifier
1.3.6.1.4.1.429.4.38.9ScalarusrGWCBSPNACNameread-onlycurrentNAC Card Name
1.3.6.1.4.1.429.4.38.10ScalarusrGWCBSPCPUTyperead-onlycurrentCPU of the product
1.3.6.1.4.1.429.4.38.11ScalarusrGWCBSPCPUSpeedread-onlycurrentThe speed in Mhz in which the CPU runs
1.3.6.1.4.1.429.4.38.12ScalarusrGWCBSPBootModeread-writecurrentThis variable decides the booting type. The possible booting types are FLASH ( the boot image is taken from the flash memory) or NETWORK (the boot image is dow…
1.3.6.1.4.1.429.4.38.13ScalarusrGWCBSPIPConfigSourceread-writecurrentThe IP configuration source
1.3.6.1.4.1.429.4.38.14TableusrGWCBSPIPTablenot-accessiblecurrentIP Interface Table
1.3.6.1.4.1.429.4.38.14.1RowusrGWCBSPIPEntrynot-accessiblecurrentIP interface Table
1.3.6.1.4.1.429.4.38.14.1.1ColumnusrGWCBSPInterfaceIndexnot-accessiblecurrentThe boot interface of the product. The possible values are eth:1 or eth:2
1.3.6.1.4.1.429.4.38.14.1.2ColumnusrGWCBSPTFTPServerread-writecurrentTFTP server used to down load the application image or upload crashdump file
1.3.6.1.4.1.429.4.38.14.1.3ColumnusrGWCBSPIPAddressread-writecurrentIP address of the selected interface
1.3.6.1.4.1.429.4.38.14.1.4ColumnusrGWCBSPIPGatewayread-writecurrentIP gateway for the selected interface
1.3.6.1.4.1.429.4.38.14.1.5ColumnusrGWCBSPNetMaskread-writecurrentIP netmask of the selected interface
1.3.6.1.4.1.429.4.38.14.1.6ColumnusrGWCBSPCrashDumpFileread-writecurrentFile name to which the crashdump will be uploaded - maximum length is 127 chars + terminator
1.3.6.1.4.1.429.4.38.14.1.7ColumnusrGWCBSPNetworkFileread-writecurrentThe download application image file name - the maximum length is 127 characters + terminator
1.3.6.1.4.1.429.4.38.14.1.8ColumnusrGWCBSPTFTPStatusread-writecurrentTFTP download config type
1.3.6.1.4.1.429.4.38.15ScalarusrGWCBSPCrashEnableread-writecurrentSays whether the crashupload option is Enabled or Disabled
1.3.6.1.4.1.429.4.38.16ScalarusrGWCBSPDiagread-writecurrentTo enable or disable Mfg Diagnostics
1.3.6.1.4.1.429.4.38.17ScalarusrGWCBSPDipSwitchesread-onlycurrentThe current DIP switch settings
1.3.6.1.4.1.429.4.38.18ScalarusrGWCBSPCrashDumpread-onlycurrentInformation about the previous crash - not accessible via SNMP, CLI only.
1.3.6.1.4.1.429.4.38.19ScalarusrGWCBSPInterfaceread-writecurrentThe boot interface of the product. The possible values are eth:1 or eth:2
1.3.6.1.4.1.429.4.38.20ScalarusrGWCBSPCrashDumpResetread-writecurrentTo Reset the Last Crash Dump
1.3.6.1.4.1.429.4.38.21ScalarusrGWCBSPCommandLineParametersread-writecurrentContains the command line parameters which are passed to the router at startup
1.3.6.1.4.1.429.4.38.22ScalarusrGWCBSPCFMStatusFlagread-writecurrentThis variable controls saving and loading of configuration information for the bsp manager Module. The value can be set to either save or load by a management …
1.3.6.1.4.1.429.4.38.23ScalarusrGWCBSPKernelVersionread-onlycurrentThe Kernel Version