19 objects
No module-level DESCRIPTION found.
OIDNameAccessStatusDescription
1.3.6.1.4.1.2338Nodevertical
1.3.6.1.4.1.2338.11Nodeenvironment
1.3.6.1.4.1.2338.11.1TableiOFanTablenot-accessiblecurrentTable of status information about all Instant Office cooling fans
1.3.6.1.4.1.2338.11.1.1RowiOFanEntrynot-accessiblemandatoryAn entry in the Fan Table.
1.3.6.1.4.1.2338.11.1.1.1ColumnfanIndexread-onlymandatoryThe index of the cooling fan within the system
1.3.6.1.4.1.2338.11.1.1.2ColumnfanOperStatusread-onlymandatoryThe operational status of this fan. The following are valid values: running =1,(the normal operational state), stopped =2, unknown =3
1.3.6.1.4.1.2338.11.2TableiOPSTablenot-accessiblecurrentTable of status information about all Instant Office power supplies
1.3.6.1.4.1.2338.11.2.1RowiOPSEntrynot-accessiblemandatoryAn entry in the Power Supply Table.
1.3.6.1.4.1.2338.11.2.1.1ColumnpsIndexread-onlymandatoryThe index of the power supply unit within the system
1.3.6.1.4.1.2338.11.2.1.2ColumnpsOperStatusread-onlymandatoryThe operational status of this power supply. The following are valid values: on=1, off=2, unknown=3
1.3.6.1.4.1.2338.11.3NodeiOFaultMonitorGroup
1.3.6.1.4.1.2338.11.3.1ScalariOFaultMonitorStatusread-onlymandatoryThe operational status of the Fault Monitor. The following are valid values: RAMFull =1, NotResponding =2, Ok =3, ModemFailed =4
1.3.6.1.4.1.2338.11.4NodeiOTrapInfoGroup
1.3.6.1.4.1.2338.11.4.1ScalariOLastFanTrapread-onlymandatoryThis object describes,in more detail,the last Fan Trap event that occured. Since traps for all fans are combined into one Trap, this string describes each fan …
1.3.6.1.4.1.2338.11.4.2ScalariOLastPowerSupplyTrapread-onlymandatoryThis object describes,in more detail,the last Power Supply Trap event that occured. Since traps for all power supplies are combined into one Trap, this string …
1.3.6.1.4.1.2338.11.4.3ScalariOLastFaultMonitorTrapread-onlymandatoryThis object describes,in more detail,the last Fault Monitor Trap event that occured. Since traps for all Fault Monitor events are combined into one Trap,this s…
1.3.6.1.4.1.2338.47NodeiOFanStatusThis notification is sent when one (or more) cooling fans changes state (i.e. it goes from an ON state to OFF state or vice-versa. Even if more than one fan ch…
1.3.6.1.4.1.2338.48NodeiOPowerSupplyStatusThis notification is sent when one (or more) power supply units changs state (i.e it goes from an ON state to an OFF state, or vice versa). Even if more than o…
1.3.6.1.4.1.2338.49NodeiOFaultMonitorStatusTrapThis notification is sent when or more of the following Fault Monitor Events occur: RAM full, Fault Monitor NotResponding or Modem Failed. Information about th…