MIB Viewer

VOLIUS-OR-MIB

93 objects
This MIB describes all SNMP-enabled hardware produced by Volius, such as Fiber optical receivers, Erbium-doped fiber amplifiers, Optical switches, CATV optical transmitters.
Imported Objects
OIDNameAccessStatusDescription
1.3.6.1.4.1.34652Nodevolius
1.3.6.1.4.1.34652.1IdentityvlsGlobalModuleThis MIB describes all SNMP-enabled hardware produced by Volius, such as Fiber optical receivers, Erbium-doped fiber amplifiers, Optical switches, CATV optical…
1.3.6.1.4.1.34652.2NodevlsSystem
1.3.6.1.4.1.34652.2.10NodevlsSystemGeneral
1.3.6.1.4.1.34652.2.10.1ScalarvlsModelNameread-onlycurrentDevice model name
1.3.6.1.4.1.34652.2.10.2ScalarvlsSerialNumberread-onlycurrentDevice serial number
1.3.6.1.4.1.34652.2.10.3ScalarvlsFirmwareVersionread-onlycurrentMain firmware version (monitoring PCB)
1.3.6.1.4.1.34652.2.10.4ScalarvlsDateAndTimeread-onlycurrentCurrent date and time, only valid when SNTP time syncronization is operational
1.3.6.1.4.1.34652.2.10.5ScalarvlsTimeZoneread-writecurrentTime zone expressed in minutes relative to UTC, used when reporting date and time, including event log
1.3.6.1.4.1.34652.2.10.6ScalarvlsCaseTemperatureread-onlycurrentCase temperature
1.3.6.1.4.1.34652.2.10.7TablevlsSupplyVoltageTablenot-accessiblecurrent
1.3.6.1.4.1.34652.2.10.7.1RowvlsSupplyVoltageEntrynot-accessiblecurrent
1.3.6.1.4.1.34652.2.10.7.1.1ColumnvlsSupplyVoltageIndexread-onlycurrentPower supply input number (1..2)
1.3.6.1.4.1.34652.2.10.7.1.2ColumnvlsSupplyVoltageNominalread-onlycurrentNominal value of supply voltage
1.3.6.1.4.1.34652.2.10.7.1.3ColumnvlsSupplyVoltageActualread-onlycurrentActually measured value of supply voltage
1.3.6.1.4.1.34652.2.10.8ScalarvlsSupplySelectModeread-writecurrentMode of operation of power supply selection logic
1.3.6.1.4.1.34652.2.10.9ScalarvlsSupplySelectedInputread-onlycurrentCurrently selected power supply (1..2)
1.3.6.1.4.1.34652.2.10.10ScalarvlsBootLoaderVersionread-onlycurrentVersion of the boot loader
1.3.6.1.4.1.34652.2.10.11ScalarvlsRfFwVerread-onlyobsolete
1.3.6.1.4.1.34652.2.10.12ScalarvlsOperatingMinutesread-onlycurrentTotal number of minutes in operation
1.3.6.1.4.1.34652.2.10.14ScalarvlsMonPcbRevisionread-onlyobsolete
1.3.6.1.4.1.34652.2.10.15ScalarvlsRfPcbRevisionread-onlyobsolete
1.3.6.1.4.1.34652.2.10.16ScalarvlsNumOpticalInputsread-onlycurrentNumber of optical inputs (1 or 2)
1.3.6.1.4.1.34652.2.11NodevlsNetworkServices
1.3.6.1.4.1.34652.2.11.5NodevlsNetworkAddress
1.3.6.1.4.1.34652.2.11.5.1ScalarvlsMacAddressread-onlycurrentDevice MAC address
1.3.6.1.4.1.34652.2.11.5.2ScalarvlsIpAddressread-writecurrentIP address
1.3.6.1.4.1.34652.2.11.5.3ScalarvlsNetMaskread-writecurrentSubnet mask
1.3.6.1.4.1.34652.2.11.5.4ScalarvlsDefaultGatewayread-writecurrentDefault gateway
1.3.6.1.4.1.34652.2.11.5.5ScalarvlsDhcpread-onlyobsolete
1.3.6.1.4.1.34652.2.11.6NodevlsHttp
1.3.6.1.4.1.34652.2.11.6.1ScalarvlsHttpPasswordread-onlyobsolete
1.3.6.1.4.1.34652.2.11.6.2ScalarvlsHttpPasswordEnabledread-writecurrentEnable/disable web interface password protection
1.3.6.1.4.1.34652.2.11.6.3ScalarvlsHttpPortread-onlydeprecated
1.3.6.1.4.1.34652.2.11.6.4ScalarvlsHttpEnabledread-onlydeprecated
1.3.6.1.4.1.34652.2.11.7NodevlsSnmp
1.3.6.1.4.1.34652.2.11.7.1ScalarvlsSnmpPortread-onlydeprecated
1.3.6.1.4.1.34652.2.11.7.2TablevlsTrapDestTablenot-accessiblecurrent
1.3.6.1.4.1.34652.2.11.7.2.1RowvlsTrapDestEntrynot-accessiblecurrent
1.3.6.1.4.1.34652.2.11.7.2.1.1ColumnvlsTrapDestIndexread-onlycurrentSNMP trap destination index (1..4)
1.3.6.1.4.1.34652.2.11.7.2.1.2ColumnvlsTrapDestAddrread-writecurrentSNMP trap destination IP address
1.3.6.1.4.1.34652.2.11.7.2.1.3ColumnvlsTrapDestPortread-onlydeprecated
1.3.6.1.4.1.34652.2.11.7.2.1.4ColumnvlsTrapDestEnableread-writecurrentEnable/disable sending of SNMP traps to this destination
1.3.6.1.4.1.34652.2.11.8NodevlsSntp
1.3.6.1.4.1.34652.2.11.8.1ScalarvlsSntpServerAddrread-writecurrentIP address of the SNTP server
1.3.6.1.4.1.34652.2.11.8.2ScalarvlsSntpServerPortread-onlydeprecated
1.3.6.1.4.1.34652.2.11.8.3ScalarvlsSntpEnabledread-writecurrentEnable/disable time synchronization with an SNTP server
1.3.6.1.4.1.34652.2.13NodevlsEventLog
1.3.6.1.4.1.34652.2.13.1ScalarvlsLastEventCoderead-onlycurrentEvent code of the latest recorder event
1.3.6.1.4.1.34652.2.13.2ScalarvlsLastEventIndexread-onlycurrentSequence number of the latest recorded event
1.3.6.1.4.1.34652.2.13.3ScalarvlsEventLogSizeread-onlycurrentThe number of events currently recorded in the log
1.3.6.1.4.1.34652.2.13.4TablevlsEventLogTablenot-accessiblecurrent
1.3.6.1.4.1.34652.2.13.4.1RowvlsEventLogEntrynot-accessiblecurrent
1.3.6.1.4.1.34652.2.13.4.1.1ColumnvlsEventIndexread-onlycurrentSequence number of the event in the log entry
1.3.6.1.4.1.34652.2.13.4.1.2ColumnvlsEventCoderead-onlycurrentEvent code of the event in the log entry
1.3.6.1.4.1.34652.2.13.4.1.3ColumnvlsEventTimeStampread-onlycurrentUp time when the event in the log entry was recorded
1.3.6.1.4.1.34652.2.13.4.1.4ColumnvlsEventDateTimeread-onlycurrentDate and time when the event in the log entry was recorded. Only valid when SNTP time syncronization is operational.
1.3.6.1.4.1.34652.2.13.4.1.5ColumnvlsEventMessageread-onlycurrentMessage string of the event in the log entry
1.3.6.1.4.1.34652.2.13.8NotificationvlsEventTrapcurrent
1.3.6.1.4.1.34652.3NodevlsEdfa
1.3.6.1.4.1.34652.4NodevlsOpticalSwitch
1.3.6.1.4.1.34652.5NodevlsCatvTransmitter
1.3.6.1.4.1.34652.6NodevlsOpticalReceiver
1.3.6.1.4.1.34652.6.1TablevlsReceiverInputTablenot-accessiblecurrent
1.3.6.1.4.1.34652.6.1.1RowvlsReceiverInputEntrynot-accessiblecurrent
1.3.6.1.4.1.34652.6.1.1.1ColumnvlsReceiverInputIndexread-onlycurrentOptical input number (1..2)
1.3.6.1.4.1.34652.6.1.1.2ColumnvlsReceiverInputPowerread-onlycurrentOptical power at the input
1.3.6.1.4.1.34652.6.2ScalarvlsReceiverSelectedInputread-onlycurrentCurrently selected optical input
1.3.6.1.4.1.34652.6.3ScalarvlsReceiverRfOutputPowerread-onlycurrent
1.3.6.1.4.1.34652.6.4ScalarvlsReceiverSwitchModeread-onlycurrentMode of operation of optical input selection logic
1.3.6.1.4.1.34652.6.5ScalarvlsReceiverInputLowThresholdread-writecurrentThe low threshold of optical input power for optical input selection logic
1.3.6.1.4.1.34652.6.6ScalarvlsReceiverInputHighThresholdread-writecurrentThe high threshold of optical input power for optical input selection logic
1.3.6.1.4.1.34652.6.7ScalarvlsReceiverManualGainread-writecurrentGain setting when AGC is off
1.3.6.1.4.1.34652.6.9ScalarvlsReceiverAgcOffsetread-writecurrentGain offset when AGC is on
1.3.6.1.4.1.34652.6.10ScalarvlsReceiverAgcStateread-writecurrentEnable/disable AGC (automatic gain control)
1.3.6.1.4.1.34652.6.11ScalarvlsReceiverCurrentGainread-onlycurrentCurrent gain of the optical receiver. This is adjusted automatically when AGC is on, or is fixed at vlsRecieverManualGain when AGC is off.
1.3.6.1.4.1.34652.6.12ScalarvlsReceiverEqualizerread-writecurrentOutput spectrum tilt adjustment
1.3.6.1.4.1.34652.6.15TablevlsReceiverSpectrumTablenot-accessiblecurrent
1.3.6.1.4.1.34652.6.15.1RowvlsReceiverSpectrumEntrynot-accessiblecurrent
1.3.6.1.4.1.34652.6.15.1.1ColumnvlsReceiverSpectrumIndexread-onlycurrent
1.3.6.1.4.1.34652.6.15.1.2ColumnvlsCenterFrequencyread-onlycurrent
1.3.6.1.4.1.34652.6.15.1.3ColumnvlsChannelTyperead-onlycurrent
1.3.6.1.4.1.34652.6.15.1.4ColumnvlsChannelLevelread-onlycurrent
Type Definitions
NameSyntaxStatusDescription
VlsDbInteger32currentThis data type represents gain expressed in dB (no fractional part).
VlsEventINTEGER { vlsEventBlinking (6), vlsEventFirmwareUpload (7), vlsEventStartUp (8), vlsEventPowerSw1 (27), vlsEventPowerSw2 (28) }current
VlsInputSwitchModeINTEGER { vlsForce1 (1), vlsForce2 (2), vlsPrefer1 (3), vlsPrefer2 (4), vlsAutoLatching (5) }current
VlsKiloHertzInteger32currentData type representing frequency in units of kHz.
VlsMilliVoltInteger32current
VlsPowerSwitchModeINTEGER { vlsForce1 (1), vlsForce2 (2), vlsAuto (3) }current
VlsTenthCelsiusInteger32currentThis data type represents temperature values that are normally expressed in degrees Celsius. Units are in tenths of a degree; for example, -5.1 degrees will be represented as -51.
VlsTenthDbInteger32currentThis data type represents power levels (or power gain) that are normally expressed in dBm (dB). Units are in tenths of a dBm (db);for example, -5.1 dB will be represented as -51
VlsTenthVoltInteger32currentThis data type represents voltage levels that are normally expressed in volts. Units are in tenths of a volt; for example, 5.1 volts will be represented as 51.
VlsTvChannelTypeINTEGER { vlsTvChannelSkip (1), vlsTvChannelAnalog (2), vlsTvChannelDigital (3), vlsTvChannelNoise (4) }current