MIB Viewer

WIENER-CRATE-MIB

173 objects
Introduction of the communication.can branch.
Imported Objects
OIDNameAccessStatusDescription
1.3.6.1.4.1.19947IdentitywienerIntroduction of the communication.can branch.
1.3.6.1.4.1.19947.1IdentitycratecurrentSNMP control for electronic crates. A crate is a complete electronic system and consists of the mechanical rack, a power supply, a fan tray and a backplane. Al…
1.3.6.1.4.1.19947.1.1IdentitysystemcurrentA collection of objects which affect the complete crate
1.3.6.1.4.1.19947.1.1.1ScalarsysMainSwitchread-writecurrentRead: An enumerated value which shows the current state of the crates main switch. Write: Try to switch the complete crate ON or OFF. Only the values ON or OFF…
1.3.6.1.4.1.19947.1.1.2ScalarsysStatusread-onlycurrentA bit string which shows the status (health) of the complete crate. If a bit is set (1), the explanation is satisfied mainOn (0), system is switched on, indivi…
1.3.6.1.4.1.19947.1.1.3ScalarsysVmeSysResetread-writecurrentRead: Always 0. Write: Trigger the generation of the VME SYSRESET or CPIC RESET signal. This signal will be active for a time of 200 ms
1.3.6.1.4.1.19947.1.1.4ScalarsysHardwareResetread-writecurrentTriggered a Reset via Watchdog or ResetLine.
1.3.6.1.4.1.19947.1.1.5ScalarsysFactoryDefaultsread-writecurrentA set operation performs a complete factory reset of ALL data stored in the controller (e.g. community names, passwords, ...).
1.3.6.1.4.1.19947.1.1.10ScalarsysConfigDoMeasurementCurrentread-writecurrentCSet the analog inputs to measure voltage or current.
1.3.6.1.4.1.19947.1.1.11ScalarsysOperatingTimeread-writecurrentThe time in seconds for how long the controller was in action.
1.3.6.1.4.1.19947.1.1.1024ScalarsysDebugMemory8read-writecurrentDebug 16-bit memory access.
1.3.6.1.4.1.19947.1.1.1025ScalarsysDebugMemory16read-writecurrentDebug 16-bit memory access.
1.3.6.1.4.1.19947.1.1.1026ScalarsysDebugMemory32read-writecurrentDebug 32-bit memory access.
1.3.6.1.4.1.19947.1.1.1027ScalarsysDebugread-writecurrentDebug communication with the MPOD. This is a direct map to the ancient functions which are accessible via USB (without SLIP/SNMP).
1.3.6.1.4.1.19947.1.1.1028ScalarsysDebugDisplayread-writecurrentDebug communication with the MPOD display.
1.3.6.1.4.1.19947.1.1.1029ScalarsysDebugBootread-writecurrentDebug communication with the simple debug interface / bootloader.
1.3.6.1.4.1.19947.1.2IdentityinputcurrentAll objects which are associated with the power input of the crate
1.3.6.1.4.1.19947.1.3IdentityoutputcurrentAll objects which are associated with the power output of the crate
1.3.6.1.4.1.19947.1.3.1ScalaroutputNumberread-onlycurrentThe number of output channels of the crate.
1.3.6.1.4.1.19947.1.3.2TableoutputTablenot-accessiblecurrentA list of output entries.
1.3.6.1.4.1.19947.1.3.2.1RowoutputEntrynot-accessiblecurrentA table row
1.3.6.1.4.1.19947.1.3.2.1.1ColumnoutputIndexnot-accessiblecurrentA unique number for each power output channel. Its value ranges between 1 and total number of output channels. This value is equivalent to the output channel n…
1.3.6.1.4.1.19947.1.3.2.1.2ColumnoutputNameread-onlycurrentA textual string containing a short name of the output. If the crate is equipped with an alphanumeric display, this string is shown to identify a output channe…
1.3.6.1.4.1.19947.1.3.2.1.3ColumnoutputGroupread-writecurrentThe group number (1...63) assigned to each channel. If commands shall be sent to all channels with a specific group number (e.g. with the groupsSwitch command …
1.3.6.1.4.1.19947.1.3.2.1.4ColumnoutputStatusread-onlycurrentA bit string which shows the status (health and operating conditions) of one output channel. If a bit is set (1), the explanation is satisfied: outputOn (0), o…
1.3.6.1.4.1.19947.1.3.2.1.5ColumnoutputMeasurementSenseVoltageread-onlycurrentThe measured voltage at the sense input lines.
1.3.6.1.4.1.19947.1.3.2.1.6ColumnoutputMeasurementTerminalVoltageread-onlycurrentThe measured voltage at the output terminals.
1.3.6.1.4.1.19947.1.3.2.1.7ColumnoutputMeasurementCurrentread-onlycurrentThe measured output current.
1.3.6.1.4.1.19947.1.3.2.1.8ColumnoutputMeasurementTemperatureread-onlycurrentThe measured temperature of the power module.
1.3.6.1.4.1.19947.1.3.2.1.9ColumnoutputSwitchread-writecurrentRead: An enumerated value which shows the current state of the output channel. Write: Change the state of the channel. If the channel is On, and the write valu…
1.3.6.1.4.1.19947.1.3.2.1.10ColumnoutputVoltageread-writecurrentThe nominal output voltage of the channel.
1.3.6.1.4.1.19947.1.3.2.1.11ColumnoutputAdjustVoltageread-writeobsoleteA posibillity to make small changes of the output voltage.
1.3.6.1.4.1.19947.1.3.2.1.12ColumnoutputCurrentread-writecurrentThe current limit of the channel.
1.3.6.1.4.1.19947.1.3.2.1.13ColumnoutputVoltageRiseRateread-writecurrentVoltage Fall Slew Rate [V/s]. The slew rate of the output voltage if it increases (after switch on or if the Voltage has been changed).
1.3.6.1.4.1.19947.1.3.2.1.14ColumnoutputVoltageFallRateread-writecurrentVoltage Rise Slew Rate [V/s]. The slew rate of the output voltage if it decreases (after switch off or if the Voltage has been changed).
1.3.6.1.4.1.19947.1.3.2.1.15ColumnoutputSupervisionBehaviorread-writecurrentA bit field packed into an integer which define the behavior of the output channel / power supply after failures. For each supervision value, a two-bit field e…
1.3.6.1.4.1.19947.1.3.2.1.16ColumnoutputSupervisionMinSenseVoltageread-writecurrentIf the measured sense voltage is below this value, the power supply performs the function defined by SupervisionAction.
1.3.6.1.4.1.19947.1.3.2.1.17ColumnoutputSupervisionMaxSenseVoltageread-writecurrentIf the measured sense voltage is above this value, the power supply performs the function defined by SupervisionAction.
1.3.6.1.4.1.19947.1.3.2.1.18ColumnoutputSupervisionMaxTerminalVoltageread-writecurrentIf the measured voltage at the power supply output terminals is above this value, the power supply performs the function defined by SupervisionAction.
1.3.6.1.4.1.19947.1.3.2.1.19ColumnoutputSupervisionMaxCurrentread-writecurrentIf the measured current is above this value, the power supply performs the function defined by SupervisionAction.
1.3.6.1.4.1.19947.1.3.2.1.20ColumnoutputSupervisionMaxTemperatureread-writecurrentIf the measured module temperature is above this value, the power supply performs the function defined by SupervisionAction.
1.3.6.1.4.1.19947.1.3.2.1.21ColumnoutputConfigMaxSenseVoltageread-writecurrentThe maximum possible value of the sense voltage
1.3.6.1.4.1.19947.1.3.2.1.22ColumnoutputConfigMaxTerminalVoltageread-writecurrentThe maximum possible value of the terminal voltage
1.3.6.1.4.1.19947.1.3.2.1.23ColumnoutputConfigMaxCurrentread-writecurrentThe maximum possible value of the output current
1.3.6.1.4.1.19947.1.3.2.1.24ColumnoutputSupervisionMaxPowerread-writecurrentIf the measured power (measured current * measured terminal voltage) is above this value, the power supply performs the function defined by SupervisionAction.
1.3.6.1.4.1.19947.1.3.2.1.25ColumnoutputCurrentRiseRateread-writecurrentCurrent Fall Slew Rate [A/s]. The slew rate of the output current if it increases (after switch on or if the Current has been changed).
1.3.6.1.4.1.19947.1.3.2.1.26ColumnoutputCurrentFallRateread-writecurrentCurrent Rise Slew Rate [A/s]. The slew rate of the output current if it decreases (after switch off or if the Current has been changed).
1.3.6.1.4.1.19947.1.3.2.1.27ColumnoutputTripTimeMaxCurrentread-writecurrentMinimum time the outputSupervisionMaxCurrent threshold must be violated to activate the trip action [ms]. The trip action is defined in outputSupervisionBehavi…
1.3.6.1.4.1.19947.1.3.2.1.28ColumnoutputHardwareLimitVoltageread-onlycurrentHardware Voltage Limit [V]. Potentiometer to adjust the global hardware voltage limit (for all channels of a module).
1.3.6.1.4.1.19947.1.3.2.1.29ColumnoutputHardwareLimitCurrentread-onlycurrentHardware Current Limit [A]. Potentiometer to adjust the global hardware current limit (for all channels of a module).
1.3.6.1.4.1.19947.1.3.2.1.30ColumnoutputConfigGainSenseVoltageread-writecurrentThe gain value of the sense voltage
1.3.6.1.4.1.19947.1.3.2.1.31ColumnoutputConfigOffsetSenseVoltageread-writecurrentThe offset value of the sense voltage
1.3.6.1.4.1.19947.1.3.2.1.32ColumnoutputConfigGainTerminalVoltageread-writecurrentThe gain value of the sense voltage
1.3.6.1.4.1.19947.1.3.2.1.33ColumnoutputConfigOffsetTerminalVoltageread-writecurrentThe offset value of the sense voltage
1.3.6.1.4.1.19947.1.3.2.1.34ColumnoutputConfigGainCurrentread-writecurrentThe gain value of the sense voltage
1.3.6.1.4.1.19947.1.3.2.1.35ColumnoutputConfigOffsetCurrentread-writecurrentThe offset value of the sense voltage
1.3.6.1.4.1.19947.1.3.2.1.37ColumnoutputUserConfigread-writecurrentDefinition of user-changeable items. A bit field packed into an integer which define the behavior of the output channel. Usable for WIENER LV devices only. The…
1.3.6.1.4.1.19947.1.3.2.1.38ColumnoutputRegulationModeread-writecurrentDefinition of the regulation mode. Deprecated, use outputUserConfig for this function in the future! It is possible to set different regulation modes, dependen…
1.3.6.1.4.1.19947.1.3.2.1.39ColumnoutputConfigMaxTemperatureread-writecurrentThe maximum possible value of outputSupervisionMaxTemperature.
1.3.6.1.4.1.19947.1.3.2.1.40ColumnoutputResistanceread-writecurrentItem to specify an external resistor. For instance a wire resistor or an external resistor to protect the detectot which is supplied by a cascaded HV module.
1.3.6.1.4.1.19947.1.3.2.1.41ColumnoutputTripTimeMinSenseVoltageread-writecurrentMinimum time the outputSupervisionMinSenseVoltage threshold must be violated to activate the trip action [ms]. The trip action is defined in outputSupervisionB…
1.3.6.1.4.1.19947.1.3.2.1.42ColumnoutputTripTimeMaxSenseVoltageread-writecurrentMinimum time the outputSupervisionMaxSenseVoltage threshold must be violated to activate the trip action [ms]. The trip action is defined in outputSupervisionB…
1.3.6.1.4.1.19947.1.3.2.1.43ColumnoutputTripTimeMaxTerminalVoltageread-writecurrentMinimum time the outputSupervisionMaxTerminalVoltage threshold must be violated to activate the trip action [ms]. The trip action is defined in outputSupervisi…
1.3.6.1.4.1.19947.1.3.2.1.44ColumnoutputTripTimeMaxTemperatureread-writecurrentMinimum time the outputSupervisionMaxTemperature threshold must be violated to activate the trip action [ms]. The trip action is defined in outputSupervisionBe…
1.3.6.1.4.1.19947.1.3.2.1.45ColumnoutputTripTimeMaxPowerread-writecurrentMinimum time the outputSupervisionMaxPower threshold must be violated to activate the trip action [ms]. The trip action is defined in outputSupervisionBehavior…
1.3.6.1.4.1.19947.1.3.2.1.46ColumnoutputTripTimeTimeoutread-writecurrentMaximum time the communication between module and controller can paused before activation the trip action [ms]. The trip action is defined in outputSupervision…
1.3.6.1.4.1.19947.1.3.2.1.47ColumnoutputTripActionMinSenseVoltageread-writecurrentTrip action if outputSuperisionMinSenseVoltage threshold has been violated. The enumerated value is: WIENER LV devices 0 ignore the failure 1 switch off this c…
1.3.6.1.4.1.19947.1.3.2.1.48ColumnoutputTripActionMaxSenseVoltageread-writecurrentTrip action if outputSuperisionMaxSenseVoltage threshold has been violated. The enumerated value is: WIENER LV devices 0 ignore the failure 1 switch off this c…
1.3.6.1.4.1.19947.1.3.2.1.49ColumnoutputTripActionMaxTerminalVoltageread-writecurrentTrip action if outputSuperisionMaxTerminalVoltage threshold has been violated. The enumerated value is: WIENER LV devices 0 ignore the failure 1 switch off thi…
1.3.6.1.4.1.19947.1.3.2.1.50ColumnoutputTripActionMaxCurrentread-writecurrentTrip action if outputSuperisionMaxCurrent threshold has been violated. The enumerated value is: WIENER LV devices 0 ignore the failure 1 switch off this channe…
1.3.6.1.4.1.19947.1.3.2.1.51ColumnoutputTripActionMaxTemperatureread-writecurrentTrip action if outputSuperisionMaxTemperature threshold has been violated. The enumerated value is: WIENER LV devices 0 ignore the failure 1 switch off this ch…
1.3.6.1.4.1.19947.1.3.2.1.52ColumnoutputTripActionMaxPowerread-writecurrentTrip action if outputSuperisionMaxPower threshold has been violated. The enumerated value is: WIENER LV devices 0 ignore the failure 1 switch off this channel …
1.3.6.1.4.1.19947.1.3.2.1.53ColumnoutputTripActionExternalInhibitread-writecurrentTrip action if the external inhibit input has been activated. The enumerated value is: WIENER LV devices 0 ignore the failure 1 switch off this channel 2 switc…
1.3.6.1.4.1.19947.1.3.2.1.54ColumnoutputTripActionTimeoutread-writecurrentTrip action if the communication between module and controller has been paused longer than outputTripTimeTimeout. The enumerated value is: WIENER LV devices 0 …
1.3.6.1.4.1.19947.1.3.2.1.1024ColumnoutputConfigDataSread-writecurrentConfiguration Data raw access. This allows to read / write output channel specific user configuration data. This OID is intended for use by WIENER system softw…
1.3.6.1.4.1.19947.1.3.2.1.1025ColumnoutputConfigDataUread-writecurrentConfiguration Data raw access. This allows to read / write output channel specific user configuration data. This OID is intended for use by WIENER system softw…
1.3.6.1.4.1.19947.1.3.3ScalargroupsNumberread-onlycurrentThe number of output groups of the crate.
1.3.6.1.4.1.19947.1.3.4TablegroupsTablenot-accessiblecurrentA list of output groups entries.
1.3.6.1.4.1.19947.1.3.4.1RowgroupsEntrynot-accessiblecurrentA table row
1.3.6.1.4.1.19947.1.3.4.1.1ColumngroupsIndexnot-accessiblecurrentA unique number for each power output group. Its value ranges between 1 and 1999. The special group 0 is predefined and gives access to all channels.
1.3.6.1.4.1.19947.1.3.4.1.9ColumngroupsSwitchread-writecurrentRead: This function is not defined with groups of output channels. Write: Switch the state of all channels of a group. If any channel is On, and the write valu…
1.3.6.1.4.1.19947.1.3.5ScalarmoduleNumberread-onlycurrentThe number of HV/LV modules of the crate.
1.3.6.1.4.1.19947.1.3.6TablemoduleTablenot-accessiblecurrentA list of output module entries.
1.3.6.1.4.1.19947.1.3.6.1RowmoduleEntrynot-accessiblecurrentA row in the table of HV/LV modules
1.3.6.1.4.1.19947.1.3.6.1.1ColumnmoduleIndexnot-accessiblecurrentA unique number for each HV/LV module. Its value ranges between 1 and the total number of HV/LV modules. Note, index 1 corresponds to ma0.
1.3.6.1.4.1.19947.1.3.6.1.2ColumnmoduleDescriptionread-onlycurrentVendor, FirmwareName, ChannelNumber, SerialNumber, FirmwareRelease Vendor WIENER or iseg FirmwareName: 'E16D0' EDS 16 channels per PCB, distributor module, ran…
1.3.6.1.4.1.19947.1.3.6.1.3IdentitymoduleAuxiliaryMeasurementVoltagecurrentThe measured module auxiliary voltages.
1.3.6.1.4.1.19947.1.3.6.1.3.1ScalarmoduleAuxiliaryMeasurementVoltage0read-onlycurrentThe measured module auxiliary voltage.
1.3.6.1.4.1.19947.1.3.6.1.3.2ScalarmoduleAuxiliaryMeasurementVoltage1read-onlycurrentThe measured module auxiliary voltage.
1.3.6.1.4.1.19947.1.3.6.1.4ColumnmoduleHardwareLimitVoltageread-onlycurrentThe module hardware voltage limit.
1.3.6.1.4.1.19947.1.3.6.1.5ColumnmoduleHardwareLimitCurrentread-onlycurrentThe module hardware current limit.
1.3.6.1.4.1.19947.1.3.6.1.6ColumnmoduleRampSpeedVoltageread-writecurrentThe module voltage ramp speed (iseg HV modules have the same ramp speed value for all channels).
1.3.6.1.4.1.19947.1.3.6.1.7ColumnmoduleRampSpeedCurrentread-writecurrentThe module current ramp speed (iseg HV modules have the same ramp speed value for all channels).
1.3.6.1.4.1.19947.1.3.6.1.8ColumnmoduleStatusread-onlycurrentA bit string which shows the current module status. If a bit is set (1), the explanation is satisfied: moduleIsFineAdjustment (0), Module has reached state fin…
1.3.6.1.4.1.19947.1.3.6.1.9ColumnmoduleEventStatusread-onlycurrentA bit string which shows the current module status. If a bit is set (1), the explanation is satisfied: moduleEventPowerFail (0), Event power fail generated by …
1.3.6.1.4.1.19947.1.3.6.1.10ColumnmoduleEventChannelStatusread-onlycurrentBit field that reserves one bit for every channel. bit 0 HV channel 0 bit 1 HV channel 1 bit x HV channel x
1.3.6.1.4.1.19947.1.3.6.1.11ColumnmoduleDoClearread-writecurrentAll events of the module will be cleared.
1.3.6.1.4.1.19947.1.3.6.1.12IdentitymoduleAuxiliaryMeasurementTemperaturecurrentThe number of auxiliary temperature sensors in the module.
1.3.6.1.4.1.19947.1.3.6.1.12.1ScalarmoduleAuxiliaryMeasurementTemperature0read-onlycurrentThe measured module temperature of sensor 1.
1.3.6.1.4.1.19947.1.3.6.1.12.2ScalarmoduleAuxiliaryMeasurementTemperature1read-onlycurrentThe measured module temperature of sensor 2.
1.3.6.1.4.1.19947.1.3.6.1.12.3ScalarmoduleAuxiliaryMeasurementTemperature2read-onlycurrentThe measured module temperature of sensor 3.
1.3.6.1.4.1.19947.1.3.6.1.12.4ScalarmoduleAuxiliaryMeasurementTemperature3read-onlycurrentThe measured module temperature of sensor 4.
1.3.6.1.4.1.19947.1.3.6.1.1024ColumnmoduleConfigDataSread-writecurrentConfiguration Data raw access. This allows to read / write output channel specific system configuration data. This OID is intended for use by WIENER system sof…
1.3.6.1.4.1.19947.1.3.6.1.1025ColumnmoduleConfigDataUread-writecurrentConfiguration Data raw access. This allows to read / write output channel specific user configuration data. This OID is intended for use by WIENER system softw…
1.3.6.1.4.1.19947.1.4IdentitysensorcurrentAll objects which are associated with temperature sensors in the crate
1.3.6.1.4.1.19947.1.4.1ScalarsensorNumberread-onlycurrentThe number of temperature sensors of the crate.
1.3.6.1.4.1.19947.1.4.2TablesensorTablenot-accessiblecurrentA (conceptual table) of temperature sensor data.
1.3.6.1.4.1.19947.1.4.2.1RowsensorEntrynot-accessiblecurrentAn entry (conceptual row) of the sensorTable.
1.3.6.1.4.1.19947.1.4.2.1.1ColumnsensorIndexnot-accessiblecurrentA unique number for each temperature sensor in the crate
1.3.6.1.4.1.19947.1.4.2.1.2ColumnsensorTemperatureread-onlycurrentThe measured temperature of the sensor. Unused temperature probes have the special value -128
1.3.6.1.4.1.19947.1.4.2.1.3ColumnsensorWarningThresholdread-writecurrentIf the measured temperature of the sensor is higher than this value, the fan speed of the connected fan tray is increased. The value 127 has the special meanin…
1.3.6.1.4.1.19947.1.4.2.1.4ColumnsensorFailureThresholdread-writecurrentIf the measured temperature of the sensor is higher than this value, the power supply switches off. The value 127 has the special meaning: channel disabled.
1.3.6.1.4.1.19947.1.4.2.1.6ColumnsensorAlarmThresholdread-writecurrentIf the measured temperature of the sensor is much higher than this value, the fans rotate in full speed. The value 127 has the special meaning: channel disable…
1.3.6.1.4.1.19947.1.4.2.1.7ColumnsensorNameread-writecurrentA textual string containing a short name of the sensor. If the crate is equipped with an alphanumeric display, this string is shown to identify a sensor channe…
1.3.6.1.4.1.19947.1.4.2.1.8ColumnsensorIDread-writecurrentShows the 1-Wire Id of the corresponding Sensor.
1.3.6.1.4.1.19947.1.4.2.1.9ColumnsensorStatusread-onlycurrentA bit field packed into an integer which define the Status of the Sensors after failures. For each Status value, a two-bit field exists. Bits-Value 00 Temperat…
1.3.6.1.4.1.19947.1.5IdentitycommunicationcurrentAll objects which affect the remote control of the crate
1.3.6.1.4.1.19947.1.5.1IdentitysnmpcurrentSNMP configuration.
1.3.6.1.4.1.19947.1.5.1.1TablesnmpCommunityTablenot-accessiblecurrentThe SNMP community string table for different views.
1.3.6.1.4.1.19947.1.5.1.1.1RowsnmpCommunityEntrynot-accessiblecurrentOne table row.
1.3.6.1.4.1.19947.1.5.1.1.1.1ColumnsnmpAccessRightnot-accessiblecurrentA unique number for each access right
1.3.6.1.4.1.19947.1.5.1.1.1.2ColumnsnmpCommunityNameread-writecurrentThe SNMP community names for different views. The rights of the different communities are: public no write access private can switch power on/off, generate sys…
1.3.6.1.4.1.19947.1.5.1.2ScalarsnmpPortread-writecurrentThe UDP port number of the SNMP protocol. A value of 0 disables all future SNMP communication!
1.3.6.1.4.1.19947.1.5.1.3ScalarhttpPortread-writecurrentThe TCP port number of the HTTP (web) protocol. A value of 0 disables all HTTP access.
1.3.6.1.4.1.19947.1.5.1.10ScalarfirmwareUpdateread-writecurrentSend a update String
1.3.6.1.4.1.19947.1.5.1.11ScalaripDynamicAddressread-onlycurrentShows the Ip which is currently used
1.3.6.1.4.1.19947.1.5.1.12ScalaripStaticAddressread-writecurrentShows the Ip which is setted by user
1.3.6.1.4.1.19947.1.5.1.13ScalarmacAddressread-writecurrentShows the MAC of the corresponding device
1.3.6.1.4.1.19947.1.5.2IdentitycancurrentCAN-Bus tunnel via SNMP.
1.3.6.1.4.1.19947.1.5.2.1ScalarcanBitRateread-writecurrentControl of the CAN-Bus. The value defines the bit rate of the CAN-bus interface. A write disconnects the CAN interface from the ISEG modules and connects it to…
1.3.6.1.4.1.19947.1.5.2.2ScalarcanReceiveread-onlycurrentControl of the CAN-Bus Receive FIFO. A read access returns the total number of CAN messages stored in the receive fifo and the oldest message. This message is …
1.3.6.1.4.1.19947.1.5.2.3ScalarcanTransmitread-writecurrentControl of the CAN-Bus Transmit FIFO. A read access returns the total number of CAN messages stored in the transmit fifo and a NULL message. A write inserts th…
1.3.6.1.4.1.19947.1.5.2.4ScalarcanReceiveHvread-onlycurrentControl of the internal HV CAN-Bus on the backplane Receive FIFO. A read access returns the total number of CAN messages stored in the receive fifo and the old…
1.3.6.1.4.1.19947.1.5.2.5ScalarcanTransmitHvread-writecurrentControl of the internal HV CAN-Bus on the backplane. A write access with: CANID=0x600 DLC=4 DATAID=0x1001 CONTROL will switch the HV modules into a special sta…
1.3.6.1.4.1.19947.1.5.2.6ScalarcanBitRateHvread-writecurrentControl of the bit rate of the HV CAN-Bus. The value defines the bit rate of the CAN-bus interface. Possible Values are 125000 and 250000. Changing this value …
1.3.6.1.4.1.19947.1.6IdentitypowersupplycurrentAll objects which are specific for the power supply of the crate
1.3.6.1.4.1.19947.1.6.2ScalarpsSerialNumberread-onlycurrentThe serial number of the power supply.
1.3.6.1.4.1.19947.1.6.3ScalarpsOperatingTimeread-writecurrentThe time in seconds for how long the power supply was switched on.
1.3.6.1.4.1.19947.1.6.4ScalarpsAuxiliaryNumberread-onlycurrentThe number of auxiliary channels of the power supply.
1.3.6.1.4.1.19947.1.6.5TablepsAuxiliaryTablenot-accessiblecurrentA list of psAuxiliary entries.
1.3.6.1.4.1.19947.1.6.5.1RowpsAuxiliaryEntrynot-accessiblecurrentA table row
1.3.6.1.4.1.19947.1.6.5.1.1ColumnpsAuxiliaryIndexnot-accessiblecurrentA unique number for each power supply auxiliary channel. Its value ranges between 1 and total number of output channels. SMI index starts at 1, so index 1 corr…
1.3.6.1.4.1.19947.1.6.5.1.3ColumnpsAuxiliaryMeasurementVoltageread-onlycurrentThe measured power supply auxiliary output voltage.
1.3.6.1.4.1.19947.1.6.5.1.4ColumnpsAuxiliaryMeasurementCurrentread-onlycurrentThe measured power supply auxiliary output current.
1.3.6.1.4.1.19947.1.6.1024ScalarpsDirectAccessread-writecurrentDirect data transfer to the UEP6000 power supply. A read access returns nothing, a write access returns the response of the power supply.
1.3.6.1.4.1.19947.1.7IdentityfantraycurrentAll objects which are specific for the fan tray of the crate
1.3.6.1.4.1.19947.1.7.2ScalarfanSerialNumberread-writecurrentThe serial number of the fan tray.
1.3.6.1.4.1.19947.1.7.3ScalarfanOperatingTimeread-writecurrentThe time in seconds for how long the fan tray was switched on.
1.3.6.1.4.1.19947.1.7.4ScalarfanAirTemperatureread-onlycurrentThe temperature of the fan tray inlet air.
1.3.6.1.4.1.19947.1.7.5ScalarfanSwitchOffDelayread-writecurrentThe maximum time in seconds for which the fans will continue running after the power supply has been switched off. This feature is used to cool down the electr…
1.3.6.1.4.1.19947.1.7.6ScalarfanNominalSpeedread-writecurrentThe nominal fan rotation speed (RPM, Revolutions Per Minute) Value 0 does switch off the fans (only allowed if at least one rack temperature sensor is present)…
1.3.6.1.4.1.19947.1.7.7ScalarfanNumberOfFansread-writecurrentThe number of installed fans
1.3.6.1.4.1.19947.1.7.8TablefanSpeedTablenot-accessiblecurrentA list of fanSpeedEntries.
1.3.6.1.4.1.19947.1.7.8.1RowfanSpeedEntrynot-accessiblecurrentA table row
1.3.6.1.4.1.19947.1.7.8.1.1ColumnfanNumbernot-accessiblecurrentA unique number for each fan.
1.3.6.1.4.1.19947.1.7.8.1.2ColumnfanSpeedread-onlycurrentThe measured fan rotation speed (RPM, Revolutions Per Minute)
1.3.6.1.4.1.19947.1.7.9ScalarfanMaxSpeedread-writecurrentThe highest allowed rotationspeed of fan.
1.3.6.1.4.1.19947.1.7.10ScalarfanMinSpeedread-writecurrentThe lowest allowed Rotationspeed of fan.
1.3.6.1.4.1.19947.1.7.11ScalarfanConfigMaxSpeedread-writecurrentHardwarelimits. Can only set by WIENER.
1.3.6.1.4.1.19947.1.7.12ScalarfanConfigMinSpeedread-writecurrentHardwarelimits Can only set by WIENER.
1.3.6.1.4.1.19947.1.8IdentityrackcurrentAll objects which are specific for the crate (BIN) of the crate
1.3.6.1.4.1.19947.1.9IdentitysignalcurrentAll objects which are associated with analog/digtal input/output in the crate
1.3.6.1.4.1.19947.1.9.1ScalarnumberOfAnalogInputsread-onlycurrentThe number of additional analog inputs of the crate.
1.3.6.1.4.1.19947.1.9.2TableanalogInputTablenot-accessiblecurrentA (conceptual table) of analog input data.
1.3.6.1.4.1.19947.1.9.2.1RowanalogInputEntrynot-accessiblecurrentAn entry (conceptual row) of the analogInputTable.
1.3.6.1.4.1.19947.1.9.2.1.1ColumnanalogInputIndexnot-accessiblecurrentA unique number for each analog input of the crate
1.3.6.1.4.1.19947.1.9.2.1.2ColumnanalogMeasurementVoltageread-onlycurrentThe measured voltage of the analog input.
1.3.6.1.4.1.19947.1.9.2.1.3ColumnanalogMeasurementCurrentread-onlycurrentThe measured current of the analog input.
1.3.6.1.4.1.19947.1.9.5ScalardigitalInputread-onlycurrentThe value of the digital inputs.
1.3.6.1.4.1.19947.1.9.6ScalardigitalOutputread-onlycurrentThe value of the digital outputs.
Type Definitions
NameSyntaxStatusDescription
FloatOpaque (SIZE (7))currentA single precision floating-point number. The semantics and encoding are identical for type 'single' defined in IEEE Standard for Binary Floating-Point, ANSI/IEEE Std 754-1985. The value is restricted to the BER seriali…
OutputTripActionINTEGER { ignore (0), channelOff (1), specialOff (2), allOff (3) } crate OBJECT-IDENTITY STATUS current DESCRIPTION "SNMP control for electronic crates. A crate is a complete electronic system and consists of the mechanical rack, a power supply, a fan tray and a backplane. All this things are necessary to provide an adequate housing for electronic modules (e.g. VME CPU's)" ::= { wiener 1 } system OBJECT-IDENTITY STATUS current DESCRIPTION "A collection of objects which affect the complete crate" ::= { crate 1 } input OBJECT-IDENTITY STATUS current DESCRIPTION "All objects which are associated with the power input of the crate" ::= { crate 2 } output OBJECT-IDENTITY STATUS current DESCRIPTION "All objects which are associated with the power output of the crate" ::= { crate 3 } sensor OBJECT-IDENTITY STATUS current DESCRIPTION "All objects which are associated with temperature sensors in the crate" ::= { crate 4 } communication OBJECT-IDENTITY STATUS current DESCRIPTION "All objects which affect the remote control of the crate" ::= { crate 5 } powersupply OBJECT-IDENTITY STATUS current DESCRIPTION "All objects which are specific for the power supply of the crate" ::= { crate 6 } fantray OBJECT-IDENTITY STATUS current DESCRIPTION "All objects which are specific for the fan tray of the crate" ::= { crate 7 } rack OBJECT-IDENTITY STATUS current DESCRIPTION "All objects which are specific for the crate (BIN) of the crate" ::= { crate 8 } signal OBJECT-IDENTITY STATUS current DESCRIPTION "All objects which are associated with analog/digtal input/output in the crate" ::= { crate 9 } System ::= SEQUENCE { sysMainSwitch INTEGER, sysStatus BITS, sysVmeSysReset INTEGER, sysHardwareReset Integer32, sysFactoryDefaults INTEGER, sysConfigDoMeasurementCurrent BITS, sysOperatingTime Integer32, sysDebugMemory8 Integer32, sysDebugMemory16 Integer32, sysDebugMemory32 Integer32, sysDebug OCTET STRING, sysDebugDisplay OCTET STRING, sysDebugBoot OCTET STRING }currentSpecial data type used for outpot trip action OIDs.
OutputTripTimeInteger32 (0..65535)currentSpecial data type used for output trip time OIDs. Represents a 16 bit unsigned integer value. BER-coded as INTEGER