MIB Viewer

WWP-ENVIRON-MIB

90 objects
The MIB module for the WWP Specifc environment. It contains the environment variables for the WWP System.
Imported Objects
SNMPv2-SMICounter32 Integer32 MODULE-IDENTITY NOTIFICATION-TYPE OBJECT-TYPE
SNMPv2-TCDisplayString TEXTUAL-CONVENTION TruthValue
WWP-SMIwwpModules
OIDNameAccessStatusDescription
1.3.6.1.4.1.6141.2.13IdentitywwpEnvironMIBThe MIB module for the WWP Specifc environment. It contains the environment variables for the WWP System.
1.3.6.1.4.1.6141.2.13.1NodewwpEnvironMIBObjects
1.3.6.1.4.1.6141.2.13.1.1NodewwpEnviron
1.3.6.1.4.1.6141.2.13.1.1.1NodewwpEnvBatteryModule
1.3.6.1.4.1.6141.2.13.1.1.1.1ScalarwwpEnvBattStatusread-onlycurrentDescribes the battery hardware the device is configured with. For Portals, the Management station should use the new added object wwpEnvPortalCurrentBattStatus…
1.3.6.1.4.1.6141.2.13.1.1.2NodewwpEnvPowerSupplyModule
1.3.6.1.4.1.6141.2.13.1.1.2.1TablewwpEnvPowerTablenot-accessiblecurrentA list of power supply entries.
1.3.6.1.4.1.6141.2.13.1.1.2.1.1RowwwpEnvPowerEntrynot-accessiblecurrentAn entry in the powerTable providing objects for a power supply.
1.3.6.1.4.1.6141.2.13.1.1.2.1.1.1ColumnwwpEnvPowerSupplyNumread-onlycurrentDenotes the power supply.
1.3.6.1.4.1.6141.2.13.1.1.2.1.1.2ColumnwwpEnvPowerSupplyStateread-onlycurrentDenotes the power supply's state.
1.3.6.1.4.1.6141.2.13.1.1.2.1.1.3ColumnwwpEnvPowerSupplyTyperead-onlycurrentDenotes the power supply type.
1.3.6.1.4.1.6141.2.13.1.1.2.1.1.4ColumnwwpEnvPowerSupplyRedundancyread-onlycurrentDenotes whether or not the power supply is redundant.
1.3.6.1.4.1.6141.2.13.1.1.2.2ScalarwwpEnvRedPowerSupplyNotifEnabledread-writedeprecatedThis variable indicates whether the system generates the wwpEnvRedPowerSupplyNotification. A false value prevents this notifications from being generated by th…
1.3.6.1.4.1.6141.2.13.1.1.3NodewwpEnvFanModule
1.3.6.1.4.1.6141.2.13.1.1.3.1TablewwpEnvFanModuleTablenot-accessiblecurrentA list of fan module entries.
1.3.6.1.4.1.6141.2.13.1.1.3.1.1RowwwpEnvFanModuleEntrynot-accessiblecurrentAn entry in the fan module Table providing objects for a fan module.
1.3.6.1.4.1.6141.2.13.1.1.3.1.1.1ColumnwwpEnvFanModuleNumread-onlycurrentDenotes the Fan module.
1.3.6.1.4.1.6141.2.13.1.1.3.1.1.2ColumnwwpEnvFanModuleStateread-onlycurrentDenotes the fan modules state.
1.3.6.1.4.1.6141.2.13.1.1.3.1.1.3ColumnwwpEnvFanAvgSpeedread-onlycurrentThe fans average speed in RPM. The average is calculated on a continuous basis from system startup.
1.3.6.1.4.1.6141.2.13.1.1.3.1.1.4ColumnwwpEnvFanCurrentSpeedread-onlycurrentThe current speed of the fan in RPM.
1.3.6.1.4.1.6141.2.13.1.1.3.1.1.5ColumnwwpEnvFanMinSpeedread-onlycurrentThe minimum speed of the fan in RPM.
1.3.6.1.4.1.6141.2.13.1.1.3.2ScalarwwpEnvFanModuleNotifEnabledread-writecurrentThis variable indicates whether the system generates the wwpEnvFanModuleNotification. A false value prevents this notifications from being generated by this sy…
1.3.6.1.4.1.6141.2.13.1.1.4NodewwpEnvTempSensor
1.3.6.1.4.1.6141.2.13.1.1.4.1TablewwpEnvTempSensorTablenot-accessiblecurrentA list of Temp Sensors entries.
1.3.6.1.4.1.6141.2.13.1.1.4.1.1RowwwpEnvTempSensorEntrynot-accessiblecurrentAn entry in the Temp Sensor Table providing objects for a Temp Sensor.
1.3.6.1.4.1.6141.2.13.1.1.4.1.1.1ColumnwwpEnvTempSensorNumread-onlycurrentDenotes the Temp sensor module.
1.3.6.1.4.1.6141.2.13.1.1.4.1.1.2ColumnwwpEnvTempSensorValueread-onlycurrentThe value of temperature measured by the sensor inside the device in degrees C.
1.3.6.1.4.1.6141.2.13.1.1.4.1.1.3ColumnwwpEnvTempSensorHighThresholdread-writecurrentThe highest value that the object wwpEnvTempSensorValue may obtain at which a wwpEnvMIBTempNotification is sent.
1.3.6.1.4.1.6141.2.13.1.1.4.1.1.4ColumnwwpEnvTempSensorLowThresholdread-writecurrentThe Lowest value that the object wwpEnvTempSensorValue may obtain at which a wwpEnvMIBTempNotification is sent.
1.3.6.1.4.1.6141.2.13.1.1.4.1.1.5ColumnwwpEnvTempSensorStateread-onlycurrentThe state indicates whether the current temp is greater than, equal to or less than the threshold state.
1.3.6.1.4.1.6141.2.13.1.1.4.2ScalarwwpEnvTempNotifEnabledread-writecurrentThis variable indicates whether the system generates the wwpEnvTempNotification. A false value prevents this notifications from being generated by this system.
1.3.6.1.4.1.6141.2.13.1.1.5NodewwpEnvPortPowerMgmt
1.3.6.1.4.1.6141.2.13.1.1.5.1TablewwpPortPowerMgmtTablenot-accessiblecurrentA list of Port Power Management entries. This table affects the port power only when the input power supply is Battery.
1.3.6.1.4.1.6141.2.13.1.1.5.1.1RowwwpPortPowerMgmtEntrynot-accessiblecurrentAn entry in the Port Power Mgmt Table providing objects for Port Power Management.
1.3.6.1.4.1.6141.2.13.1.1.5.1.1.1ColumnwwpEnvPortBankIdread-onlycurrentDenotes the Port Bank module. A Bank is a set of ports for the power management when the source of the input power is switched to battery.
1.3.6.1.4.1.6141.2.13.1.1.5.1.1.2ColumnwwpEnvPortMapread-onlycurrentThe port map associated with this BankId.
1.3.6.1.4.1.6141.2.13.1.1.5.1.1.3ColumnwwpEnvPortBankOnread-writecurrentThe object to decide whether the port related to this Bank should be on or not if the input power supply is switched to Battery.
1.3.6.1.4.1.6141.2.13.1.1.6NodewwpEnvNotif
1.3.6.1.4.1.6141.2.13.1.1.6.1ScalarwwpPowerSwitchingOpread-onlycurrentThe object to notify whether the input power supply is switching from ac to Battery or vice versa.
1.3.6.1.4.1.6141.2.13.1.1.7NodewwpEnvPortalBatteryModule
1.3.6.1.4.1.6141.2.13.1.1.7.1ScalarwwpEnvPortalBatteryStatusread-onlycurrentDescribes the current status of the battery. If battery is connected then the status is indicated as 'present'.
1.3.6.1.4.1.6141.2.13.1.1.7.2ScalarwwpEnvPortalBatteryVoltageLevelread-onlycurrentDescribes the current voltage level of the battery.
1.3.6.1.4.1.6141.2.13.1.1.7.3ScalarwwpEnvPortalBatteryConditionread-onlycurrentDescribes the current condition of the battery.
1.3.6.1.4.1.6141.2.13.1.1.7.4ScalarwwpEnvPortalPowerSourceread-onlycurrentDescribes the current power source for the device.
1.3.6.1.4.1.6141.2.13.1.1.7.5ScalarwwpEnvBatteryNormalStateNameread-writecurrentThe state name associated with the low state of the battery.
1.3.6.1.4.1.6141.2.13.1.1.7.6ScalarwwpEnvBatteryLowStateNameread-writecurrentThe state name associated with the normal state of the battery.
1.3.6.1.4.1.6141.2.13.1.1.7.7ScalarwwpEnvBatteryGoodStateNameread-writecurrentThe state name associated with the good state of the battery.
1.3.6.1.4.1.6141.2.13.1.1.7.8ScalarwwpEnvBatteryBadStateNameread-writecurrentThe state name associated with the bad state of the battery.
1.3.6.1.4.1.6141.2.13.1.1.7.9ScalarwwpEnvBatteryPresentStateNameread-writecurrentThe state name associated with the battery state 'present'.
1.3.6.1.4.1.6141.2.13.1.1.7.10ScalarwwpEnvBatteryMissingStateNameread-writecurrentThe state name associated with the battery state 'missing'.
1.3.6.1.4.1.6141.2.13.1.1.7.11ScalarwwpEnvBatteryPowerPrimaryStateNameread-writecurrentThe state name associated with the state when the device is on primary power.
1.3.6.1.4.1.6141.2.13.1.1.7.12ScalarwwpEnvBatteryPowerBatteryStateNameread-writecurrentThe state name associated with the state when the device is on battery power.
1.3.6.1.4.1.6141.2.13.1.1.7.13ScalarwwpEnvBatteryLowStateNotifEnabledread-writecurrentThis variable indicates whether the system will generate the wwpEnvPortalBatteryStatusNotification in case of battery state changing from normal to low or vice…
1.3.6.1.4.1.6141.2.13.1.1.7.14ScalarwwpEnvBatteryBadStateNotifEnabledread-writecurrentThis variable indicates whether the system will generate the wwpEnvPortalBatteryStatusNotification in case of battery state changing from good to bad or vice v…
1.3.6.1.4.1.6141.2.13.1.1.7.15ScalarwwpEnvBatteryMissingStateNotifEnabledread-writecurrentThis variable indicates whether the system will generate the wwpEnvPortalBatteryStatusNotification in case of battery state changing from present to missing or…
1.3.6.1.4.1.6141.2.13.1.1.7.16ScalarwwpEnvBatteryPowerNotifEnabledread-writecurrentThis variable indicates whether the system will generate the wwpEnvPortalBatteryStatusNotification in case of input power changing from primary to battery or v…
1.3.6.1.4.1.6141.2.13.1.1.7.17ScalarwwpEnvBatteryPeriodicTrapsTimerread-writecurrentAdjusts the amount of time, in hours, when the current state of the battery is evaluated and status traps are automatically issued. When set to zero (0) no per…
1.3.6.1.4.1.6141.2.13.1.1.7.18ScalarwwpEnvBatteryPowerUpTrapsEnableread-writecurrentWhen set to true, upon portal power-up the state of the battery is evaluated and status traps are issued. When set to false, no portal power-up battery state t…
1.3.6.1.4.1.6141.2.13.1.1.8NodewwpEnvDoorModule
1.3.6.1.4.1.6141.2.13.1.1.8.1ScalarwwpEnvDoorStateread-onlycurrentThe state of the door.
1.3.6.1.4.1.6141.2.13.1.1.8.2ScalarwwpEnvDoorNotifEnabledread-writecurrentThis variable indicates whether the system generates the wwpEnvDoorStateChgNotification. A false value prevents this notifications from being generated by this…
1.3.6.1.4.1.6141.2.13.1.1.9NodewwpEnvDryContactModule
1.3.6.1.4.1.6141.2.13.1.1.9.1ScalarwwpEnvDryContactOpenStateNameread-writecurrentThe state name associated with the open state of the dry contact.
1.3.6.1.4.1.6141.2.13.1.1.9.2ScalarwwpEnvDryContactOpenStateChgAccumulateread-writecurrentSetting this object to 'enable' will cause the system to accumulate open state changes.
1.3.6.1.4.1.6141.2.13.1.1.9.3ScalarwwpEnvDryContactOpenStateCountread-onlycurrentThe number of times the dry contact has entered the open state.
1.3.6.1.4.1.6141.2.13.1.1.9.4ScalarwwpEnvDryContactOpenStateNotifEnabledread-writecurrentThis variable indicates whether the system generates the wwpEnvDryContactOpenStateNotification. A false value prevents this notifications from being generated …
1.3.6.1.4.1.6141.2.13.1.1.9.5ScalarwwpEnvDryContactCloseStateNameread-writecurrentThe state name associated with the close state of the dry contact.
1.3.6.1.4.1.6141.2.13.1.1.9.6ScalarwwpEnvDryContactCloseStateChgAccumulateread-writecurrentSetting this object to 'enable' will cause the system to accumulate close state changes.
1.3.6.1.4.1.6141.2.13.1.1.9.7ScalarwwpEnvDryContactCloseStateCountread-onlycurrentThe number of times the dry contact has entered the close state.
1.3.6.1.4.1.6141.2.13.1.1.9.8ScalarwwpEnvDryContactCloseStateNotifEnabledread-writecurrentThis variable indicates whether the system generates the wwpEnvDryContactCloseStateNotification. A false value prevents this notifications from being generated…
1.3.6.1.4.1.6141.2.13.1.1.10NodewwpEnvRFModule
1.3.6.1.4.1.6141.2.13.1.1.10.1ScalarwwpEnvRFModuleStateread-writecurrentSetting this object to 'enable' will set the the RF state to 'enable'.
1.3.6.1.4.1.6141.2.13.1.1.10.2ScalarwwpEnvRFModuleSignalDetectread-onlycurrentThe status of signal detect by the RF Module.
1.3.6.1.4.1.6141.2.13.2NodewwpEnvironMIBNotificationPrefix
1.3.6.1.4.1.6141.2.13.2.0NodewwpEnvironMIBNotifications
1.3.6.1.4.1.6141.2.13.2.0.1NotificationwwpEnvPowerSupplyStatusNotificationcurrentA wwpEnvPowerSupplyStatusNotification is sent if a power supply state is changed.
1.3.6.1.4.1.6141.2.13.2.0.2NotificationwwpEnvFanModuleNotificationcurrentA wwpEnvFanModuleNotification is sent if the fan state changes.
1.3.6.1.4.1.6141.2.13.2.0.3NotificationwwpEnvTempNotificationcurrentA wwpEnvTempNotification is sent if the wwpEnvTempSensorState is changed.
1.3.6.1.4.1.6141.2.13.2.0.4NotificationwwpEnvPowerSwitchNotificationcurrentA wwpEnvPowerSwitchNotification is sent if the input power supply is switched to Battery from the AC power or switched from the Battery to the AC Power.
1.3.6.1.4.1.6141.2.13.2.0.5NotificationwwpEnvPortalBatteryStatusNotificationcurrentA wwpEnvPortalBatteryStatusNotification is sent if the Battery status changes. If the device supports the configurable battery state names, then the correspond…
1.3.6.1.4.1.6141.2.13.2.0.6NotificationwwpEnvPortalBatteryVoltageLevelNotificationcurrentA wwpEnvPortalBatteryVoltageLevelNotification is sent if the Battery voltage level changes from normal to low or vice versa. If the device supports the configu…
1.3.6.1.4.1.6141.2.13.2.0.7NotificationwwpEnvPortalBatteryConditionNotificationcurrentA wwpEnvPortalBatteryConditionNotification is sent if the Battery condition changes from good to bad or vice versa. If the device supports the configurable bat…
1.3.6.1.4.1.6141.2.13.2.0.8NotificationwwpEnvPortalPowerSourceNotificationcurrentA wwpEnvPortalPowerSourceNotification is sent if the Battery input power source changes from battery to primary power or vice versa. A device which supports ww…
1.3.6.1.4.1.6141.2.13.2.0.9NotificationwwpEnvDoorStateChgNotificationcurrentA wwpEnvDoorStateChgNotification is sent if the door state changes.
1.3.6.1.4.1.6141.2.13.2.0.10NotificationwwpEnvDryContactOpenStateNotificationcurrentA wwpEnvDryContactOpenStateNotification is sent when the dry contact enters in the open state.
1.3.6.1.4.1.6141.2.13.2.0.11NotificationwwpEnvDryContactCloseStateNotificationcurrentA wwpEnvDryContactCloseStateNotification is sent when the dry contact enters in the close state.
1.3.6.1.4.1.6141.2.13.3NodewwpEnvironMIBConformance
1.3.6.1.4.1.6141.2.13.3.1NodewwpEnvironMIBCompliances
1.3.6.1.4.1.6141.2.13.3.2NodewwpEnvironMIBGroups
Type Definitions
NameSyntaxStatusDescription
PortListOCTET STRING (SIZE (0..255))currentEach octet within this value specifies a set of eight ports, with the first octet specifying ports 1 through 8, the second octet specifying ports 9 through 16, etc. Within each octet, the most significant bit represents…