Wellfleet-DS1-MIB
64 objects
No module-level DESCRIPTION found.
Imported Objects
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.18.3.4.12.1 | TablewfDs1Config | not-accessible | mandatory | The DS1 Configuration table |
| 1.3.6.1.4.1.18.3.4.12.1.1 | RowwfDs1ConfigEntry | not-accessible | mandatory | per circuit DS1 configuration objects; wfDs1LineIndex corresponds to Wellfleet circuit number |
| 1.3.6.1.4.1.18.3.4.12.1.1.1 | ColumnwfDs1LineIndex | read-only | mandatory | this corresponds to the Wellfleet circuit number |
| 1.3.6.1.4.1.18.3.4.12.1.1.2 | ColumnwfDs1TimeElapsed | read-only | mandatory | 1..900 seconds within the current 15-minute interval |
| 1.3.6.1.4.1.18.3.4.12.1.1.3 | ColumnwfDs1ValidIntervals | read-only | mandatory | 0..96 previous intervals that valid data were collected. This is 96 unless the CSU device was brought on line within the last 24 hours. |
| 1.3.6.1.4.1.18.3.4.12.1.1.4 | ColumnwfDs1LineType | read-only | mandatory | the variety of DS1 implementing this circuit |
| 1.3.6.1.4.1.18.3.4.12.1.1.5 | ColumnwfDs1ZeroCoding | read-only | mandatory | the variety of Zero Code Suppression used on the link |
| 1.3.6.1.4.1.18.3.4.12.1.1.6 | ColumnwfDs1SendCode | read-only | mandatory | the type of code being sent across the DS1 circuit by the CSU |
| 1.3.6.1.4.1.18.3.4.12.1.1.7 | ColumnwfDs1CircuitIdentifier | read-only | mandatory | the transmission vendor's circuit identifier |
| 1.3.6.1.4.1.18.3.4.12.1.1.8 | ColumnwfDs1LoopbackConfig | read-only | mandatory | the loopback state of the CSU |
| 1.3.6.1.4.1.18.3.4.12.1.1.9 | ColumnwfDs1LineStatus | read-only | mandatory | the state of the DS1 line |
| 1.3.6.1.4.1.18.3.4.12.2 | TablewfDs1Current | not-accessible | mandatory | The DS1 Current table |
| 1.3.6.1.4.1.18.3.4.12.2.1 | RowwfDs1CurrentEntry | not-accessible | mandatory | per circuit DS1 current objects - wfDs1CurrentIndex corresponds to Wellfleet circuit number |
| 1.3.6.1.4.1.18.3.4.12.2.1.1 | ColumnwfDs1CurrentIndex | read-only | mandatory | this corresponds to the Wellfleet circuit number |
| 1.3.6.1.4.1.18.3.4.12.2.1.2 | ColumnwfDs1CurrentESs | read-only | mandatory | the count of errored seconds in the current interval |
| 1.3.6.1.4.1.18.3.4.12.2.1.3 | ColumnwfDs1CurrentSESs | read-only | mandatory | the count of severely errored seconds in the current interval |
| 1.3.6.1.4.1.18.3.4.12.2.1.4 | ColumnwfDs1CurrentSEFs | read-only | mandatory | the count of severely errored framing seconds in the current interval |
| 1.3.6.1.4.1.18.3.4.12.2.1.5 | ColumnwfDs1CurrentUASs | read-only | mandatory | the number of unavailable seconds in the current interval |
| 1.3.6.1.4.1.18.3.4.12.2.1.6 | ColumnwfDs1CurrentBPVs | read-only | mandatory | the count of bipolar violations in the current interval |
| 1.3.6.1.4.1.18.3.4.12.2.1.7 | ColumnwfDs1CurrentCVs | read-only | mandatory | the count of code violation error events in the current interval |
| 1.3.6.1.4.1.18.3.4.12.3 | TablewfDs1Interval | not-accessible | mandatory | The DS1 Interval table |
| 1.3.6.1.4.1.18.3.4.12.3.1 | RowwfDs1IntervalEntry | not-accessible | mandatory | per circuit DS1 interval objects - wfDs1IntervalIndex corresponds to Wellfleet circuit number, wfDs1IntervalNumber is the numbered previous 15-minute interval |
| 1.3.6.1.4.1.18.3.4.12.3.1.1 | ColumnwfDs1IntervalIndex | read-only | mandatory | this corresponds to the Wellfleet circuit number |
| 1.3.6.1.4.1.18.3.4.12.3.1.2 | ColumnwfDs1IntervalNumber | read-only | mandatory | 1..96 where 1 is the most recent 15-minute interval and 96 is the least |
| 1.3.6.1.4.1.18.3.4.12.3.1.3 | ColumnwfDs1IntervalESs | read-only | mandatory | the count of errored seconds in the specified interval |
| 1.3.6.1.4.1.18.3.4.12.3.1.4 | ColumnwfDs1IntervalSESs | read-only | mandatory | the count of severely errored seconds in the specified interval |
| 1.3.6.1.4.1.18.3.4.12.3.1.5 | ColumnwfDs1IntervalSEFs | read-only | mandatory | the count of severely errored framing seconds in the specified interval |
| 1.3.6.1.4.1.18.3.4.12.3.1.6 | ColumnwfDs1IntervalUASs | read-only | mandatory | the number of unavailable seconds in the specified interval |
| 1.3.6.1.4.1.18.3.4.12.3.1.7 | ColumnwfDs1IntervalBPVs | read-only | mandatory | the count of bipolar violations in the specified interval |
| 1.3.6.1.4.1.18.3.4.12.3.1.8 | ColumnwfDs1IntervalCVs | read-only | mandatory | the count of code violation error events in the specified interval |
| 1.3.6.1.4.1.18.3.4.12.4 | TablewfDs1Total | not-accessible | mandatory | The DS1 Total table |
| 1.3.6.1.4.1.18.3.4.12.4.1 | RowwfDs1TotalEntry | not-accessible | mandatory | per circuit DS1 total objects - wfDs1TotalIndex corresponds to Wellfleet circuit number |
| 1.3.6.1.4.1.18.3.4.12.4.1.1 | ColumnwfDs1TotalIndex | read-only | mandatory | this corresponds to the Wellfleet circuit number |
| 1.3.6.1.4.1.18.3.4.12.4.1.2 | ColumnwfDs1TotalESs | read-only | mandatory | total count of errored seconds |
| 1.3.6.1.4.1.18.3.4.12.4.1.3 | ColumnwfDs1TotalSESs | read-only | mandatory | total count of severely errored seconds |
| 1.3.6.1.4.1.18.3.4.12.4.1.4 | ColumnwfDs1TotalSEFs | read-only | mandatory | total count of severely errored framing seconds |
| 1.3.6.1.4.1.18.3.4.12.4.1.5 | ColumnwfDs1TotalUASs | read-only | mandatory | total number of unavailable seconds |
| 1.3.6.1.4.1.18.3.4.12.4.1.6 | ColumnwfDs1TotalBPVs | read-only | mandatory | total count of bipolar violations |
| 1.3.6.1.4.1.18.3.4.12.4.1.7 | ColumnwfDs1TotalCVs | read-only | mandatory | total count of code violation error events |
| 1.3.6.1.4.1.18.3.4.12.5 | TablewfDs1FeCurrent | not-accessible | mandatory | The DS1 Far End Current table |
| 1.3.6.1.4.1.18.3.4.12.5.1 | RowwfDs1FeCurrentEntry | not-accessible | mandatory | per circuit DS1 far end current objects wfDs1CurrentIndex corresponds to Wellfleet circuit number |
| 1.3.6.1.4.1.18.3.4.12.5.1.1 | ColumnwfDs1FeCurrentIndex | read-only | mandatory | this corresponds to the Wellfleet circuit number |
| 1.3.6.1.4.1.18.3.4.12.5.1.2 | ColumnwfDs1FeCurrentESs | read-only | mandatory | the count of errored seconds in the current interval |
| 1.3.6.1.4.1.18.3.4.12.5.1.3 | ColumnwfDs1FeCurrentSESs | read-only | mandatory | the count of severely errored seconds in the current interval |
| 1.3.6.1.4.1.18.3.4.12.5.1.4 | ColumnwfDs1FeCurrentSEFs | read-only | mandatory | the count of severely errored framing seconds in the current interval |
| 1.3.6.1.4.1.18.3.4.12.5.1.5 | ColumnwfDs1FeCurrentBPVs | read-only | mandatory | the count of bipolar violations in the current interval |
| 1.3.6.1.4.1.18.3.4.12.5.1.6 | ColumnwfDs1FeCurrentCVs | read-only | mandatory | the count of code violation error events in the current interval |
| 1.3.6.1.4.1.18.3.4.12.6 | TablewfDs1FeInterval | not-accessible | mandatory | The DS1 Far End Interval table |
| 1.3.6.1.4.1.18.3.4.12.6.1 | RowwfDs1FeIntervalEntry | not-accessible | mandatory | per circuit DS1 far end interval objects - wfDs1FeIntervalIndex corresponds to Wellfleet circuit number, wfDs1FeIntervalNumber is the numbered previous 15-minu… |
| 1.3.6.1.4.1.18.3.4.12.6.1.1 | ColumnwfDs1FeIntervalIndex | read-only | mandatory | this corresponds to the Wellfleet circuit number |
| 1.3.6.1.4.1.18.3.4.12.6.1.2 | ColumnwfDs1FeIntervalNumber | read-only | mandatory | 1..96 where 1 is the most recent 15-minute interval and 96 is the least |
| 1.3.6.1.4.1.18.3.4.12.6.1.3 | ColumnwfDs1FeIntervalESs | read-only | mandatory | the count of errored seconds in the specified interval |
| 1.3.6.1.4.1.18.3.4.12.6.1.4 | ColumnwfDs1FeIntervalSESs | read-only | mandatory | the count of severely errored seconds in the specified interval |
| 1.3.6.1.4.1.18.3.4.12.6.1.5 | ColumnwfDs1FeIntervalSEFs | read-only | mandatory | the count of severely errored framing seconds in the specified interval |
| 1.3.6.1.4.1.18.3.4.12.6.1.6 | ColumnwfDs1FeIntervalBPVs | read-only | mandatory | the count of bipolar violations in the specified interval |
| 1.3.6.1.4.1.18.3.4.12.6.1.7 | ColumnwfDs1FeIntervalCVs | read-only | mandatory | the count of code violation error events in the specified interval |
| 1.3.6.1.4.1.18.3.4.12.7 | TablewfDs1FeTotal | not-accessible | mandatory | The DS1 Far End Total table |
| 1.3.6.1.4.1.18.3.4.12.7.1 | RowwfDs1FeTotalEntry | not-accessible | mandatory | per circuit DS1 far end total objects - wfDs1FeTotalIndex corresponds to Wellfleet circuit number |
| 1.3.6.1.4.1.18.3.4.12.7.1.1 | ColumnwfDs1FeTotalIndex | read-only | mandatory | this corresponds to the Wellfleet circuit number |
| 1.3.6.1.4.1.18.3.4.12.7.1.2 | ColumnwfDs1FeTotalESs | read-only | mandatory | total count of errored seconds |
| 1.3.6.1.4.1.18.3.4.12.7.1.3 | ColumnwfDs1FeTotalSESs | read-only | mandatory | total count of severely errored seconds |
| 1.3.6.1.4.1.18.3.4.12.7.1.4 | ColumnwfDs1FeTotalSEFs | read-only | mandatory | total count of severely errored framing seconds |
| 1.3.6.1.4.1.18.3.4.12.7.1.5 | ColumnwfDs1FeTotalBPVs | read-only | mandatory | total count of bipolar violations |
| 1.3.6.1.4.1.18.3.4.12.7.1.6 | ColumnwfDs1FeTotalCVs | read-only | mandatory | total count of code violation error events |