1.3.6.1.4.1.18.3.4.26.10TablewfDs3E3ConfigTablenot-accessiblemandatoryThe DS3/E3 Configuration table
1.3.6.1.4.1.18.3.4.26.10.1RowwfDs3E3ConfigEntrynot-accessiblemandatoryper circuit DS3/E3 configuration objects; wfDs3E3ConfigLineIndex corresponds to Wellfleet circuit number
1.3.6.1.4.1.18.3.4.26.10.1.1ColumnwfDs3E3ConfigDeleteread-writemandatoryCreate/Delete parameter
1.3.6.1.4.1.18.3.4.26.10.1.2ColumnwfDs3E3ConfigDisableread-writemandatoryEnable/Disable parameter
1.3.6.1.4.1.18.3.4.26.10.1.3ColumnwfDs3E3ConfigStateread-onlymandatoryState of the DS3 Port.
1.3.6.1.4.1.18.3.4.26.10.1.4ColumnwfDs3E3ConfigLastChangeread-onlymandatoryThe value of sysUpTime at the time the interface entered its current operational state.
1.3.6.1.4.1.18.3.4.26.10.1.5ColumnwfDs3E3ConfigLineIndexread-onlymandatorythis corresponds to the Wellfleet circuit number
1.3.6.1.4.1.18.3.4.26.10.1.6ColumnwfDs3E3ConfigIfIndexread-onlymandatorythis is value of ifIndex from the Interfaces table of MIB II (RFC 1213).
1.3.6.1.4.1.18.3.4.26.10.1.7ColumnwfDs3E3ConfigLineTyperead-writemandatorythe variety of DS3/E3 application implementing this circuit
1.3.6.1.4.1.18.3.4.26.10.1.8ColumnwfDs3E3ConfigLineCodingread-writemandatorythe variety of Zero Code Suppression used on the link
1.3.6.1.4.1.18.3.4.26.10.1.9ColumnwfDs3E3ConfigLoopbackConfigread-writemandatorythe loopback configuration of the DS3/E3 interface
1.3.6.1.4.1.18.3.4.26.10.1.10ColumnwfDs3E3ConfigLineStatusread-onlymandatorythe status of the DS3/E3 line
1.3.6.1.4.1.18.3.4.26.10.1.11ColumnwfDs3E3ConfigPrimaryClockSourceread-writemandatorySelects the Primary source of the Tx Clock for the DS3/E3 interface
1.3.6.1.4.1.18.3.4.26.10.1.12ColumnwfDs3E3ConfigSecondaryClockSourceread-writemandatorySelects the Secondary source of the Tx Clock for the DS3/E3 interface
1.3.6.1.4.1.18.3.4.26.10.1.13ColumnwfDs3E3ConfigMturead-writemandatoryMTU parameter for all channels on DS3 .
1.3.6.1.4.1.18.3.4.26.10.1.14ColumnwfDs3E3ConfigLineBuildOutread-writemandatorySet according to cable length, short (less than 225 feet) or long (greater than 225 feet).
1.3.6.1.4.1.18.3.4.26.10.1.15ColumnwfDs3E3ConfigCurrentClockread-onlymandatoryIndicates the clock source currently in use by the DS1
1.3.6.1.4.1.18.3.4.26.10.1.16ColumnwfDs3E3ConfigExtClockOperationalread-onlymandatoryIndicates whether the External clock is operational
1.3.6.1.4.1.18.3.4.26.10.1.17ColumnwfDs3E3ConfigSetupAlarmThresholdread-writemandatorySpecifies setup time for performance failure conditions, in seconds. When a performance defect is present for greater than the time specified by this parameter…
1.3.6.1.4.1.18.3.4.26.10.1.18ColumnwfDs3E3ConfigClearAlarmThresholdread-writemandatorySpecifies clear time for performance failure conditions, in seconds. When a performance failure condition has been cleared for greater than the time specified …
1.3.6.1.4.1.18.3.4.26.10.1.19ColumnwfDs3E3ConfigLoopbackStateread-onlymandatoryIndicates the current loopback state of this interface. The interface can be in one the following states: Line Loopback Payload Loopback no loopback Loopback m…
1.3.6.1.4.1.18.3.4.26.10.1.20ColumnwfDs3E3ConfigSendCoderead-onlymandatoryThis variable is currently read-only and it indicates what type of code has been sent across the DS3 interface by the device. The values mean: SENDNOCODE - sen…
1.3.6.1.4.1.18.3.4.26.17TablewfDs3E3ActionTablenot-accessiblemandatoryDS3E3 configuration Action record - write only Configuration parameters
1.3.6.1.4.1.18.3.4.26.17.1RowwfDs3E3ActionEntrynot-accessiblemandatoryAn entry in the DS3E3 Config table
1.3.6.1.4.1.18.3.4.26.17.1.1ColumnwfDs3E3ActionPortLineNumberread-onlymandatoryInstance ID LineNumber, filled in by driver
1.3.6.1.4.1.18.3.4.26.17.1.2ColumnwfDs3E3ActionSendFeacLoopCoderead-writemandatorySelects a Far End Alarm and Control Channel code to be sent to the remote end.
1.3.6.1.4.1.18.3.4.26.17.1.3ColumnwfDs3E3ActionSendFeacDs1LoopUpCoderead-writemandatorySelects Loop Up code to be sent to the remote end for a DS1. Value passed through this attribute is the DS1 Port number (1 through 28).
1.3.6.1.4.1.18.3.4.26.17.1.4ColumnwfDs3E3ActionSendFeacDs1LoopDownCoderead-writemandatorySelects Loop Down code to be sent to the remote end for a DS1. Value passed through this attribute is the DS1 Port number (1 through 28).
1.3.6.1.4.1.18.3.4.26.17.1.5ColumnwfDs3E3ActionClearCurrentStatsread-writemandatoryClears this port's Current 15 minute Statistics.
1.3.6.1.4.1.18.3.4.26.17.1.6ColumnwfDs3E3ActionClearFarEndCurrentStatsread-writemandatoryClears this port's Far End, Current 15 minute Statistics.
1.3.6.1.4.1.18.3.4.26.17.1.7ColumnwfDs3E3ActionClearDayCurrentStatsread-writemandatoryClears this port's Current Day Statistics.
1.3.6.1.4.1.18.3.4.26.17.1.8ColumnwfDs3E3ActionClearFarEndDayCurrentStatsread-writemandatoryClears this port's Far End, Current Day Statistics.
1.3.6.1.4.1.18.3.4.26.17.1.9ColumnwfDs3E3ActionClearIntervalStatsread-writemandatoryClears All Interval Statistics (15 minute and day) of this port.
1.3.6.1.4.1.18.3.4.26.17.1.10ColumnwfDs3E3ActionClearFarEndIntervalStatsread-writemandatoryClears All Far End Interval Statistics (15 minute and day) of this port.