Wellfleet-OCX-MIB
18 objects
No module-level DESCRIPTION found.
Imported Objects
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.18.3.4.24.21 | TablewfOcxConfigTable | not-accessible | mandatory | Ocx Configuration Table |
| 1.3.6.1.4.1.18.3.4.24.21.1 | RowwfOcxConfigEntry | not-accessible | mandatory | An entry in the Ocx Configuration table |
| 1.3.6.1.4.1.18.3.4.24.21.1.1 | ColumnwfOcxConfigDelete | read-write | mandatory | Create/Delete parameter |
| 1.3.6.1.4.1.18.3.4.24.21.1.2 | ColumnwfOcxConfigDisable | read-write | mandatory | Create/Delete parameter |
| 1.3.6.1.4.1.18.3.4.24.21.1.3 | ColumnwfOcxConfigIndex | read-only | mandatory | Index for this physical Sonet interface. |
| 1.3.6.1.4.1.18.3.4.24.21.1.4 | ColumnwfOcxConfigIfIndex | read-only | mandatory | this is value of ifIndex from the Interfaces table of MIB II (RFC 1213). |
| 1.3.6.1.4.1.18.3.4.24.21.1.5 | ColumnwfOcxConfigState | read-only | mandatory | State of the OCX Port. |
| 1.3.6.1.4.1.18.3.4.24.21.1.6 | ColumnwfOcxConfigLineStatus | read-only | mandatory | the status of the OCX |
| 1.3.6.1.4.1.18.3.4.24.21.1.7 | ColumnwfOcxConfigLastChange | read-only | mandatory | The value of sysUpTime at the time the interface entered its current operational state. |
| 1.3.6.1.4.1.18.3.4.24.21.1.8 | ColumnwfOcxConfigConnType | read-write | mandatory | This variable describes the Connector Type for this interface. This Mib is used for various types, OC3, OC12, etc... |
| 1.3.6.1.4.1.18.3.4.24.21.1.9 | ColumnwfOcxConfigType | read-only | mandatory | This variable identifies whether a SONET or a SDH signal is used across this interface. |
| 1.3.6.1.4.1.18.3.4.24.21.1.10 | ColumnwfOcxConfigLineCoding | read-write | mandatory | This variable describes the line coding for this interface. |
| 1.3.6.1.4.1.18.3.4.24.21.1.11 | ColumnwfOcxConfigLineType | read-write | mandatory | This variable describes the line type for this interface. |
| 1.3.6.1.4.1.18.3.4.24.21.1.12 | ColumnwfOcxConfigLoopbackConfig | read-write | mandatory | the loopback configuration of the OCX interface |
| 1.3.6.1.4.1.18.3.4.24.21.1.13 | ColumnwfOcxConfigManagerMethod | read-write | mandatory | This attribute has no affect on the Hardware configuration. This attribute is purely for any Network Management Tool to determine whether it configured the OCX… |
| 1.3.6.1.4.1.18.3.4.24.21.1.14 | ColumnwfOcxConfigApsEnable | read-write | mandatory | This attribute Enables or Disables the APS failover. |
| 1.3.6.1.4.1.18.3.4.24.21.1.15 | ColumnwfOcxConfigScrambling | read-write | mandatory | This attribute turns scrambling on or off. |
| 1.3.6.1.4.1.18.3.4.24.21.1.16 | ColumnwfOcxConfigClkSource | read-write | mandatory | The source of the physical interface clocking signal, either internal or external. |