Wellfleet-SIP-MIB
24 objects
No module-level DESCRIPTION found.
Imported Objects
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.18.3.4.14.1 | TablewfSipL2 | not-accessible | mandatory | The SIP L2 Table |
| 1.3.6.1.4.1.18.3.4.14.1.1 | RowwfSipL2Entry | not-accessible | mandatory | per circuit SIP Level 2 objects - wfSipL2Index corresponds to Wellfleet circuit number |
| 1.3.6.1.4.1.18.3.4.14.1.1.1 | ColumnwfSipL2Index | read-only | mandatory | this corresponds to the Wellfleet circuit number |
| 1.3.6.1.4.1.18.3.4.14.1.1.2 | ColumnwfSipL2ReceivedCounts | read-only | mandatory | total of unerrored received SIP L2 PDUs |
| 1.3.6.1.4.1.18.3.4.14.1.1.3 | ColumnwfSipL2SentCounts | read-only | mandatory | total of unerrored SIP L2 PDU's sent across the SNI |
| 1.3.6.1.4.1.18.3.4.14.1.1.4 | ColumnwfSipHcsOrCRCErrors | read-only | mandatory | total SIP L2 PDUs with HCS or CRC errors |
| 1.3.6.1.4.1.18.3.4.14.1.1.5 | ColumnwfSipL2PayloadLengthErrors | read-only | mandatory | total SIP L2 PDUs with length errors |
| 1.3.6.1.4.1.18.3.4.14.1.1.6 | ColumnwfSipL2SequenceNumberErrors | read-only | mandatory | total SIP L2 PDUs with unexpected sequence numbers |
| 1.3.6.1.4.1.18.3.4.14.1.1.7 | ColumnwfSipL2MidCurrentlyActiveErrors | read-only | mandatory | number of SIP L2 PDUs with BOMs previously started |
| 1.3.6.1.4.1.18.3.4.14.1.1.8 | ColumnwfSipL2BomOrSSMsMIDErrors | read-only | mandatory | number of SIP L2 PDUs with zero BOMs or SSMs not zero |
| 1.3.6.1.4.1.18.3.4.14.1.1.9 | ColumnwfSipL2EomsMIDErrors | read-only | mandatory | number of SIP L2 PDUs with zero EOMs or EOMs without BOMs |
| 1.3.6.1.4.1.18.3.4.14.2 | NodewfSipPlcpGroup | |||
| 1.3.6.1.4.1.18.3.4.14.2.1 | TablewfSipDs1Plcp | not-accessible | mandatory | The SIP DS1 PLCP Table |
| 1.3.6.1.4.1.18.3.4.14.2.1.1 | RowwfSipDs1PlcpEntry | not-accessible | mandatory | per circuit DS1 PLCP objects - wfSipDs1PlcpIndex corresponds to Wellfleet circuit number |
| 1.3.6.1.4.1.18.3.4.14.2.1.1.1 | ColumnwfSipDs1PlcpIndex | read-only | mandatory | this corresponds to the Wellfleet circuit number |
| 1.3.6.1.4.1.18.3.4.14.2.1.1.2 | ColumnwfSipDs1PlcpSEFs | read-only | mandatory | number of second intervals containing one or more severely errored seconds |
| 1.3.6.1.4.1.18.3.4.14.2.1.1.3 | ColumnwfSipDs1PlcpAlarmState | read-only | mandatory | alarm state |
| 1.3.6.1.4.1.18.3.4.14.2.1.1.4 | ColumnwfSipDs1PlcpUASs | read-only | mandatory | number of second intervals containing one or more unavailable seconds |
| 1.3.6.1.4.1.18.3.4.14.2.2 | TablewfSipDs3Plcp | not-accessible | mandatory | The SIP DS3 PLCP Table |
| 1.3.6.1.4.1.18.3.4.14.2.2.1 | RowwfSipDs3PlcpEntry | not-accessible | mandatory | per circuit DS3 PLCP objects - wfSipDs3PlcpIndex corresponds to Wellfleet circuit number |
| 1.3.6.1.4.1.18.3.4.14.2.2.1.1 | ColumnwfSipDs3PlcpIndex | read-only | mandatory | this corresponds to the Wellfleet circuit number |
| 1.3.6.1.4.1.18.3.4.14.2.2.1.2 | ColumnwfSipDs3PlcpSEFs | read-only | mandatory | number of second intervals containing one or more severely errored seconds |
| 1.3.6.1.4.1.18.3.4.14.2.2.1.3 | ColumnwfSipDs3PlcpAlarmState | read-only | mandatory | alarm state |
| 1.3.6.1.4.1.18.3.4.14.2.2.1.4 | ColumnwfSipDs3PlcpUASs | read-only | mandatory | number of second intervals containing one or more unavailable seconds |