MIB Viewer

Wellfleet-SMDS-MIB

20 objects
No module-level DESCRIPTION found.
OIDNameAccessStatusDescription
1.3.6.1.4.1.18.3.5.9.3TablewfSmdsCircuitTablenot-accessiblemandatoryThe Wellfleet SMDS Circuit Record
1.3.6.1.4.1.18.3.5.9.3.1RowwfSmdsCircuitEntrynot-accessiblemandatoryper Wellfleet circuit SMDS configuration parameters and counters
1.3.6.1.4.1.18.3.5.9.3.1.1ColumnwfSmdsCircuitDeleteread-writemandatorycreate/delete parameter, dflt = created
1.3.6.1.4.1.18.3.5.9.3.1.2ColumnwfSmdsCircuitDisableread-writemandatoryenable/disable parameter, dflt = enabled
1.3.6.1.4.1.18.3.5.9.3.1.3ColumnwfSmdsCircuitStateread-onlymandatorySMDS state variable, Up, Down Init, Not Present
1.3.6.1.4.1.18.3.5.9.3.1.4ColumnwfSmdsCircuitIDread-onlymandatorycct number for this instance
1.3.6.1.4.1.18.3.5.9.3.1.5ColumnwfSmdsCircuitIndivAddrread-writemandatorySMDS E.164 Individual address for this Wellfleet circuit - must be 8 octets long
1.3.6.1.4.1.18.3.5.9.3.1.6ColumnwfSmdsCircuitGroupAddrread-writemandatorySMDS E.164 Group address for this Wellfleet circuit - must be 8 octets long
1.3.6.1.4.1.18.3.5.9.3.1.7ColumnwfSmdsCircuitArpAddrread-writemandatorySMDS E.164 ARP address for this Wellfleet circuit - must be 8 octets long
1.3.6.1.4.1.18.3.5.9.3.1.8ColumnwfSmdsCircuitDisableHrtbtPollread-writemandatorydetermine use of DXI heartbeat poll
1.3.6.1.4.1.18.3.5.9.3.1.9ColumnwfSmdsCircuitHrtbtPollIntervalread-writemandatoryheartbeat polling messages get sent every this many seconds - we don't want the polling interval to be less than or equal to the unacknowledgment timer, which …
1.3.6.1.4.1.18.3.5.9.3.1.10ColumnwfSmdsCircuitHrtbtPollDownCountread-writemandatoryif this many consecutive heartbeat polling messages go unacknowledged, log an event declaring the line down
1.3.6.1.4.1.18.3.5.9.3.1.11ColumnwfSmdsCircuitDisableNetMgmtread-writemandatorydetermine use of LMI network management
1.3.6.1.4.1.18.3.5.9.3.1.12ColumnwfSmdsCircuitSipL3ReceivedIndividualDAsread-onlymandatoryThe total number of individually addressed SIP Level 3 PDUs received from the remote system across the SNI. The total includes only unerrored L3PDUs.
1.3.6.1.4.1.18.3.5.9.3.1.13ColumnwfSmdsCircuitSipL3ReceivedGAsread-onlymandatoryThe total number of group addressed SIP Level 3 PDUs received from the remote system across the SNI. The total includes only unerrored L3PDUs.
1.3.6.1.4.1.18.3.5.9.3.1.14ColumnwfSmdsCircuitSipL3SentIndividualDAsread-onlymandatoryThe number of individually addressed SIP Level 3 PDUs that have been sent by this system across the SNI.
1.3.6.1.4.1.18.3.5.9.3.1.15ColumnwfSmdsCircuitSipL3SentGAsread-onlymandatoryThe number of group addressed SIP L3PDUs that have been sent by this system across the SNI.
1.3.6.1.4.1.18.3.5.9.3.1.16ColumnwfSmdsCircuitSipL3VersionSupportread-onlymandatoryA value which indicates the version(s) of SIP that this interface supports. The value is a sum. This sum initially takes the value zero. For each version, V, t…
1.3.6.1.4.1.18.3.5.9.3.1.17ColumnwfSmdsCircuitDisableAddrVerifyread-writemandatoryThis object enables/disables verification checking of destination addresses in received packets.
1.3.6.1.4.1.18.3.5.9.3.1.18ColumnwfSmdsCircuitAddrVerifyDiscardsread-onlymandatoryThis is the count of SMDS PDUs discarded due to mismatched group or individual addresses