X25-OPT-MIB
158 objects
No module-level DESCRIPTION found.
Imported Objects
| RFC-1212 | OBJECT-TYPE |
| RFC1155-SMI | Counter enterprises Gauge |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.449 | Nodecodex | |||
| 1.3.6.1.4.1.449.2 | NodecdxProductSpecific | |||
| 1.3.6.1.4.1.449.2.1 | Nodecdx6500 | |||
| 1.3.6.1.4.1.449.2.1.2 | Nodecdx6500Configuration | |||
| 1.3.6.1.4.1.449.2.1.2.1 | Nodecdx6500CfgProtocolGroup | |||
| 1.3.6.1.4.1.449.2.1.2.1.1 | Nodecdx6500PCTPortProtocolGroup | |||
| 1.3.6.1.4.1.449.2.1.2.1.1.2 | Tablecdx6500PPCTX25PortTable | not-accessible | mandatory | A table of X.25 Port configuration entries. |
| 1.3.6.1.4.1.449.2.1.2.1.1.2.1 | Rowcdx6500PPCTX25PortEntry | not-accessible | mandatory | An X.25 Configuration Table entry. Each entry contains the configuration parameters for a single X.25 port. |
| 1.3.6.1.4.1.449.2.1.2.1.1.2.1.1 | Columncdx6500X25CfgPortNumber | read-only | mandatory | Port number for this X.25 port. |
| 1.3.6.1.4.1.449.2.1.2.1.1.2.1.2 | Columncdx6500X25CfgConnType | read-write | mandatory | Specify the control signal handshake and clocking required for a connection to be made to this port: simp - simple, no control signals required. dtr - dedicate… |
| 1.3.6.1.4.1.449.2.1.2.1.1.2.1.3 | Columncdx6500X25CfgPortCont | read-write | mandatory | Specify any of the following port control options: NONE - no option specified. MB - raise Pin 22 when the port becomes disabled. |
| 1.3.6.1.4.1.449.2.1.2.1.1.2.1.4 | Columncdx6500X25CfgClockSource | read-write | mandatory | int - internal clock source. ext - external clock source. extint - internal receive and external transmit clock source (DCE only). extlp - external receive and… |
| 1.3.6.1.4.1.449.2.1.2.1.1.2.1.5 | Columncdx6500X25CfgClockSpeed | read-write | mandatory | This is the speed of the port in bits per second, when using internal clocking. The highest available speed is dependant on the card type, and on the interface… |
| 1.3.6.1.4.1.449.2.1.2.1.1.2.1.6 | Columncdx6500X25CfgAdmnInterfaceMode | read-write | mandatory | The logical link address must be set to complementary values in devices at each end of the link: dte - link to have logical DTE address (A). dce - link to have… |
| 1.3.6.1.4.1.449.2.1.2.1.1.2.1.7 | Columncdx6500X25CfgAdmnNumberPVCs | read-write | mandatory | Number of logical channels used for Permanent Virtual Circuits. The total number of PVC and SVC channels on a link should be kept as small as possible and cons… |
| 1.3.6.1.4.1.449.2.1.2.1.1.2.1.8 | Columncdx6500X25CfgStartPVCChanNum | read-write | mandatory | This is the starting logical channel number for the Permanent Virtual Circuits on this link. Not used if the number of PVCs = 0. |
| 1.3.6.1.4.1.449.2.1.2.1.1.2.1.9 | Columncdx6500X25CfgNumberSVCs | read-write | mandatory | Number of logical channels used in Switched Virtual Circuits. The total number of PVC and SVC channels on a link should be kept as small as possible and consis… |
| 1.3.6.1.4.1.449.2.1.2.1.1.2.1.10 | Columncdx6500X25CfgStartSVCChanNum | read-write | mandatory | This is the starting logical channel number for the Switched Virtual Circuits on this link. Not used if the number of SVCs = 0. |
| 1.3.6.1.4.1.449.2.1.2.1.1.2.1.11 | Columncdx6500X25CfgInitFrame | read-write | mandatory | Specify the initial frame required by other end for link startup: none - do nothing (other end initiates link-up). sabm - send SABM. disc - send DISC, then SAB… |
| 1.3.6.1.4.1.449.2.1.2.1.1.2.1.12 | Columncdx6500X25CfgT1RetryTimer | read-write | mandatory | T1 link retry timer value in tenths of a second (e.g. 30 = 3.0 seconds). |
| 1.3.6.1.4.1.449.2.1.2.1.1.2.1.13 | Columncdx6500X25CfgT4PollTimer | read-write | mandatory | This sets the time an idle link is probed for assurance of connection to the remote device. 0 - disable the timer X - X is in tenths of a second (e.g. 40 = 4.0… |
| 1.3.6.1.4.1.449.2.1.2.1.1.2.1.14 | Columncdx6500X25CfgN2TransTries | read-write | mandatory | The maximum number of attempts allowed to complete a transmission. |
| 1.3.6.1.4.1.449.2.1.2.1.1.2.1.15 | Columncdx6500X25CfgFrameSeqCounting | read-write | mandatory | Port uses normal or extended frame sequence numbering norm - normal sequence counting (Modulo 8). ext - extended sequencing (Modulo 128). |
| 1.3.6.1.4.1.449.2.1.2.1.1.2.1.16 | Columncdx6500X25CfgKFrameWindow | read-write | mandatory | Frame level window size must be set to the same value in devices at each end of the link. |
| 1.3.6.1.4.1.449.2.1.2.1.1.2.1.17 | Columncdx6500X25CfgAdmnPacketSequencing | read-write | mandatory | Port uses normal or extended packet level sequence numbers : norm - normal sequencing (Modulo 8). ext - extended sequencing (Modulo 128). The value must be the… |
| 1.3.6.1.4.1.449.2.1.2.1.1.2.1.18 | Columncdx6500X25CfgWPacketWindow | read-write | mandatory | Packet level window size must be set to the same value in devices at each end of the link. |
| 1.3.6.1.4.1.449.2.1.2.1.1.2.1.19 | Columncdx6500X25CfgPPacketSize | read-write | mandatory | This is the maximum packet size used on X.25 links. For proper operation, the size must be the same in devices at each end of the link. |
| 1.3.6.1.4.1.449.2.1.2.1.1.2.1.20 | Columncdx6500X25CfgMaxNegotPacketSize | read-write | mandatory | This is the maximum negotiated packet size allowed for inbound and outbound calls on this X.25 link. |
| 1.3.6.1.4.1.449.2.1.2.1.1.2.1.21 | Columncdx6500X25CfgDataQueueUpper | read-write | mandatory | This is the maximum number of data packets a channel on this port will queue for transmission before invoking flow control to the attached channel |
| 1.3.6.1.4.1.449.2.1.2.1.1.2.1.22 | Columncdx6500X25CfgDataQueueLower | read-write | mandatory | This is the number of data packets a channel on this port will have queued for transmission when it releases flow control to the attached channel |
| 1.3.6.1.4.1.449.2.1.2.1.1.2.1.23 | Columncdx6500X25CfgAdmnRestartTimer | read-write | mandatory | Restart-Request timeout timer in seconds. If timer expires, request is sent again. |
| 1.3.6.1.4.1.449.2.1.2.1.1.2.1.24 | Columncdx6500X25CfgAdmnResetTimer | read-write | mandatory | Reset-Request timeout timer in seconds. If timer expires, request is sent again. |
| 1.3.6.1.4.1.449.2.1.2.1.1.2.1.25 | Columncdx6500X25CfgAdmnCallTimer | read-write | mandatory | Call-Request timeout timer in seconds. If timer expires, call is cleared. |
| 1.3.6.1.4.1.449.2.1.2.1.1.2.1.26 | Columncdx6500X25CfgAdmnClearTimer | read-write | mandatory | Clear-Request timeout timer in seconds. If timer expires, request is sent again. |
| 1.3.6.1.4.1.449.2.1.2.1.1.2.1.27 | Columncdx6500X25CfgOutDelFacilities | read-write | mandatory | Specify facilities deleted from an outbound call before it is forwarded: NONE - no facilities deleted. THRO - delete throughput class negotiation. NUI - delete… |
| 1.3.6.1.4.1.449.2.1.2.1.1.2.1.28 | Columncdx6500X25CfgOutAddFacilities | read-write | mandatory | Specify facilities added to an outbound call before it is forwarded: NONE - no facilities added. REV - add reverse charging. PACK - add packet size negotiation… |
| 1.3.6.1.4.1.449.2.1.2.1.1.2.1.29 | Columncdx6500X25CfgOutBarFacilities | read-write | mandatory | Specify facilities which, if present in an outbound call will be blocked by the port: NONE - no facility blocked. REV - bar reverse charging. FAST - bar fast s… |
| 1.3.6.1.4.1.449.2.1.2.1.1.2.1.30 | Columncdx6500X25CfgInBarFacilities | read-write | mandatory | Specify facilities which, if present in an inbound call, will be blocked by the port: NONE - no facility blocked. BCUG - bar Bilateral Closed User Group. DGRAM… |
| 1.3.6.1.4.1.449.2.1.2.1.1.2.1.31 | Columncdx6500X25CfgOptions | read-write | mandatory | Select options on this X.25 port as follows: NONE - no option specified. 1980 - use X.25 1980. NUI - perform network user identification validation check. PDN … |
| 1.3.6.1.4.1.449.2.1.2.1.1.2.1.32 | Columncdx6500X25CfgNumRoutDigits | read-write | mandatory | This specifies the number of routing digits in the call user data. It is used on X.25 links attached to a Public Data Network where the private network address… |
| 1.3.6.1.4.1.449.2.1.2.1.1.2.1.33 | Columncdx6500X25CfgPortDigitsToStrip | read-write | mandatory | For X.25 links connected to a Public Data Network, this parameter specifies the number of prefix digits to remove from the called address before forwarding the… |
| 1.3.6.1.4.1.449.2.1.2.1.1.2.1.34 | Columncdx6500X25CfgInDigitsToStrip | read-write | mandatory | For X.25 links connected to a Public Data Network, this parameter specifies the number of prefix digits to remove from the incoming calling address before forw… |
| 1.3.6.1.4.1.449.2.1.2.1.1.2.1.35 | Columncdx6500X25CfgRestrictConn | read-write | mandatory | All calls entering this port will be routed to the destination specified in this parameter, irrespective of route selection table entries. Blank this field to … |
| 1.3.6.1.4.1.449.2.1.2.1.1.2.1.36 | Columncdx6500X25CfgPortAddress | read-write | mandatory | On X.25 links: If the X.25 Option REGO or REGI is selected, this address is inserted into the calling address field of the outbound or inbound call packet. On … |
| 1.3.6.1.4.1.449.2.1.2.1.1.2.1.37 | Columncdx6500X25CfgCUGMember | read-write | mandatory | The port may be a member of up to 8 different Closed User Groups (CUGs). Each CUG membership must be a two digit number (except ` ( e.g. 12,34,56,09,02,03 ). `… |
| 1.3.6.1.4.1.449.2.1.2.1.1.2.1.38 | Columncdx6500X25CfgBillRec | read-write | mandatory | This controls whether billing (accounting) records will be created for calls on this port. |
| 1.3.6.1.4.1.449.2.1.2.1.1.2.1.39 | Columncdx6500X25CfgSubAddrSize | read-write | mandatory | For ports connected to a Public Data Network, this parameter specifies the number of digits in the subaddress of an X.25 address. |
| 1.3.6.1.4.1.449.2.1.2.1.1.2.1.40 | Columncdx6500X25CfgIdleDiscTimer | read-write | mandatory | The time in seconds that the port must be idle (no calls) before being automatically disconnected. A value of 0 disables the Idle Disconnect feature. This feat… |
| 1.3.6.1.4.1.449.2.1.2.1.1.2.1.41 | Columncdx6500X25CfgCallSecurity | read-write | mandatory | For ports used as V.25 bis backup, this parameter specifies the type of call security to use prior to the link being detected up : disable - Disable will allow… |
| 1.3.6.1.4.1.449.2.1.2.1.1.2.1.42 | Columncdx6500X25CfgProtectLevel | read-write | mandatory | This specifies the level of data or connection protection which will be applied to calls to or from this port. The actual level for a call will be negotiated t… |
| 1.3.6.1.4.1.449.2.1.2.1.1.2.1.43 | Columncdx6500X25CfgReconnTimeout | read-write | mandatory | This specifies the number of seconds that DCP on the originating side will wait between reconnection attempts. |
| 1.3.6.1.4.1.449.2.1.2.1.1.2.1.44 | Columncdx6500X25CfgReconnTriesLimit | read-write | mandatory | This specifies the number of times that DCP on the originating side will attempt to reconnect before clearing the call. If 0 is entered, it will not attempt to… |
| 1.3.6.1.4.1.449.2.1.2.1.1.2.1.45 | Columncdx6500X25CfgFacilSubscripCont | read-only | mandatory | NONE - Subscription to facilities not enforced. FCN-ON - Flow Control Negotiation enabled. Packet and Window size negotiation facilities in an inbound call wil… |
| 1.3.6.1.4.1.449.2.1.2.1.1.2.1.46 | Columncdx6500X25CfgAlarmPriority | read-write | mandatory | Specify the severity level of LINK UP and LINK DOWN alarms : network - Severity HIGH alarms will be generated. access - Severity LOW alarms will be generated. |
| 1.3.6.1.4.1.449.2.1.2.1.1.2.1.47 | Columncdx6500X25CfgAddrTrans | read-write | mandatory | Select any of the following address translation options NONE - no option specified Outbound Call Processing: DEDO - delete called address. DEGO - delete callin… |
| 1.3.6.1.4.1.449.2.1.2.1.1.2.1.48 | Columncdx6500X25CfgNumberInSVCs | read-write | mandatory | Number of logical channels used in One Way Incoming Switched Virtual Circuits. The total number of PVC, One Way Incoming, One Way Outgoing and Two Way SVC chan… |
| 1.3.6.1.4.1.449.2.1.2.1.1.2.1.49 | Columncdx6500X25CfgStartInSVCChanNum | read-write | mandatory | This is the starting logical channel number for the One Way Incoming Switched Virtual Circuits on this link. Not used if the number of One Way Incoming SVCs = … |
| 1.3.6.1.4.1.449.2.1.2.1.1.2.1.50 | Columncdx6500X25CfgNumberOutSVCs | read-write | mandatory | Number of logical channels used in One Way Outgoing Switched Virtual Circuits. The total number of PVC, One Way Outgoing, One Way Outgoing and Two Way SVC chan… |
| 1.3.6.1.4.1.449.2.1.2.1.1.2.1.51 | Columncdx6500X25CfgStartOutSVCChanNum | read-write | mandatory | This is the starting logical channel number for the One Way Outgoing Switched Virtual Circuits on this link. Not used if the number of One Way Outgoing SVCs = … |
| 1.3.6.1.4.1.449.2.1.2.1.1.2.1.52 | Columncdx6500X25CfgChargeInfoReq | read-write | mandatory | This parameter specifies whether Charging Information has to be sent even without requesting. |
| 1.3.6.1.4.1.449.2.1.2.1.1.2.1.53 | Columncdx6500X25CfgVerfnTimer | read-write | mandatory | Specify the NUI verification timer in seconds. The call is cleared if timer expires. |
| 1.3.6.1.4.1.449.2.1.2.1.1.2.1.54 | Columncdx6500X25CfgValdFailures | read-write | mandatory | The maximum number of successive NUI verification failures an X.25 DTE can tolerate when making verification attempts timer expires. |
| 1.3.6.1.4.1.449.2.1.2.1.1.2.1.55 | Columncdx6500X25CfgActionType | read-write | mandatory | This specifies the course of action to be taken if the NUI violations exceed the configured threshold count. This parameter is effective only if the X25 option… |
| 1.3.6.1.4.1.449.2.1.2.1.1.2.1.56 | Columncdx6500X25CfgLineIdleMode | read-write | mandatory | Specify any of the following line idle mode options: FLAG - Flag fill between frames MARK - Mark idle between frames |
| 1.3.6.1.4.1.449.2.1.2.1.1.2.1.57 | Columncdx6500X25CfgConfOption | read-write | mandatory | Select any of the following conformance control options: NONE - no option specified CHKFAC - Checking of facility codes enabled. |
| 1.3.6.1.4.1.449.2.1.2.1.1.2.1.58 | Columncdx6500X25CfgInvertTxClk | read-write | mandatory | This parameter specifies whether the phase of the transmit clock should be inverted. NO - Don't invert YES - Invert |
| 1.3.6.1.4.1.449.2.1.2.1.1.2.1.59 | Columncdx6500X25CfgDimType | read-write | mandatory | Specify the physical interface type to be used for this port: V.36 - V.36 physical interface EIA-530A - EIA-530A physical interface V.35 - V.35 physical interf… |
| 1.3.6.1.4.1.449.2.1.2.1.1.2.1.60 | Columncdx6500X25CfgMoreOptions | read-write | mandatory | Select more options on this X.25 port as follows: NONE - no option specified INLB - set with INL option to improve performance if inter-node link is a high spe… |
| 1.3.6.1.4.1.449.2.1.2.1.1.2.1.61 | Columncdx6500X25CfgPsfFlag | read-write | mandatory | Enable or Disable Port Selection Facility feature. Used to control access to ports for Select user group applications. |
| 1.3.6.1.4.1.449.2.1.2.1.1.2.1.62 | Columncdx6500X25CfgElectricalInterfaceType | read-write | mandatory | Specify the Electrical Interface Type: V.24 - V.24 Electrical Interface Type V.35 - V.35 Electrical Interface Type V.36 - V.36 Electrical Interface Type X.21 -… |
| 1.3.6.1.4.1.449.2.1.2.1.1.2.1.63 | Columncdx6500X25CfgV24ElectricalInterfaceOption | read-write | mandatory | Specify the Pin 22 option: RI - V.24 uses Pin 22 for Ring Indicator output signal TM - V.24 uses Pin 22 for Test Mode input signal |
| 1.3.6.1.4.1.449.2.1.2.1.1.2.1.64 | Columncdx6500X25CfgHighSpeedElectricalInterfaceOption | read-write | mandatory | Specify the cable type: NONE - V.35/V.36/X.21 DCE with straight through cable XOVER - V.35/V.36/X.21 DCE with crossover adapter cable |
| 1.3.6.1.4.1.449.2.1.2.2 | Nodecdx6500CfgGeneralGroup | |||
| 1.3.6.1.4.1.449.2.1.2.2.2 | Tablecdx6500CGTInboundCallTranTable | not-accessible | mandatory | All of the configuration parameters relevant to the Inbound Call Translation table. |
| 1.3.6.1.4.1.449.2.1.2.2.2.1 | Rowcdx6500CGTInboundCallTranEntry | not-accessible | mandatory | A row of Inbound Call Translation configuration parameters. |
| 1.3.6.1.4.1.449.2.1.2.2.2.1.1 | Columncdx6500InCallTranEntryNum | read-only | mandatory | This is not a configuration parameter. Instead, it identifies the particular Inbound Call Translation Table entry being configured by the other parameters in t… |
| 1.3.6.1.4.1.449.2.1.2.2.2.1.2 | Columncdx6500InCallTranInSubAddr | read-write | mandatory | This is the subaddress contained in an inbound call from another network, usually a public data network (PDN). It will be translated into a private network add… |
| 1.3.6.1.4.1.449.2.1.2.2.2.1.3 | Columncdx6500InCallTranPrivNetAddr | read-write | mandatory | This is the private network address to translate to, before forwarding calls from a PDN. |
| 1.3.6.1.4.1.449.2.1.2.2.3 | Tablecdx6500CGTOutboundCallTranTable | not-accessible | mandatory | All of the configuration parameters relevant to the Outbound Call Translation table. |
| 1.3.6.1.4.1.449.2.1.2.2.3.1 | Rowcdx6500CGTOutboundCallTranEntry | not-accessible | mandatory | A row of Outbound Call Translation configuration parameters. |
| 1.3.6.1.4.1.449.2.1.2.2.3.1.1 | Columncdx6500OutCallTranEntryNum | read-only | mandatory | This is not a configuration parameter. Instead, it identifies the particular Outbound Call Translation Table entry being configured by the other parameters in … |
| 1.3.6.1.4.1.449.2.1.2.2.3.1.2 | Columncdx6500OutCallTranPrivNetAddr | read-write | mandatory | This is the private network address contained in an outbound call to another network, usually a public data network (PDN). It will be translated into a PDN add… |
| 1.3.6.1.4.1.449.2.1.2.2.3.1.3 | Columncdx6500OutCallTranOutNetAddr | read-write | mandatory | This is the public network address to translate to, before forwarding calls to a PDN. |
| 1.3.6.1.4.1.449.2.1.2.2.3.1.4 | Columncdx6500OutCallTranOptions | read-write | mandatory | This parameter specifies options for outbound call address translation as follows: olda - insert the original called address into outbound call user data. newv… |
| 1.3.6.1.4.1.449.2.1.2.2.13 | Tablecdx6500CGTCallingAddrTranTable | not-accessible | mandatory | All of the configuration parameters relevant to the Calling AddressTranslation table. |
| 1.3.6.1.4.1.449.2.1.2.2.13.1 | Rowcdx6500CGTCallingAddrTranEntry | not-accessible | mandatory | A row of Calling Address Translation configuration parameters. |
| 1.3.6.1.4.1.449.2.1.2.2.13.1.1 | Columncdx6500CalladdrtranEntryNum | read-only | mandatory | This is not a configuration parameter. Instead, it identifies the entry being configured by the other parameters in the record. |
| 1.3.6.1.4.1.449.2.1.2.2.13.1.2 | Columncdx6500CalladdrtranInCallAddr | read-write | mandatory | This is the calling address contained in an inbound call, it will be translated into a private network address (if a match is found in the Translation Table), … |
| 1.3.6.1.4.1.449.2.1.2.2.13.1.3 | Columncdx6500CalladdrtranPrivNetAddr | read-write | mandatory | This is the private network address to translate to, before forwarding the call. |
| 1.3.6.1.4.1.449.2.1.2.2.23 | Tablecdx6500CGTCudBaseAddrTranTable | not-accessible | mandatory | All of the configuration parameters relevant to the CUD Base AddressTranslation table. |
| 1.3.6.1.4.1.449.2.1.2.2.23.1 | Rowcdx6500CGTCudBaseAddrTranEntry | not-accessible | mandatory | A row of CUD Base Address Translation configuration parameters. |
| 1.3.6.1.4.1.449.2.1.2.2.23.1.1 | Columncdx6500CudBaseaddrtranEntryNum | read-only | mandatory | This is not a configuration parameter. Instead, it identifies the entry being configured by the other parameters in the record. |
| 1.3.6.1.4.1.449.2.1.2.2.23.1.2 | Columncdx6500CudBaseStr | read-write | mandatory | Enter the sub-string to search in the CUD for the incoming call for translating it into Called address. For searching from index in the CUD the name can be spe… |
| 1.3.6.1.4.1.449.2.1.2.2.23.1.3 | Columncdx6500CudBaseAddr | read-write | mandatory | Enter the X.25 Address which will be inserted for called address of incoming X.25 call packet if the configured CUD string is matched in the CUD of the incomin… |
| 1.3.6.1.4.1.449.2.1.3 | Nodecdx6500Statistics | |||
| 1.3.6.1.4.1.449.2.1.3.1 | Nodecdx6500StatProtocolGroup | |||
| 1.3.6.1.4.1.449.2.1.3.1.1 | Nodecdx6500PSTPortProtocolGroup | |||
| 1.3.6.1.4.1.449.2.1.3.1.1.2 | Tablecdx6500PPSTX25PortTable | not-accessible | mandatory | A table of X.25 Port statistics. |
| 1.3.6.1.4.1.449.2.1.3.1.1.2.1 | Rowcdx6500PPSTX25PortEntry | not-accessible | mandatory | An X.25 Statistics Table entry. Each entry contains the statistics for a single X.25 port. |
| 1.3.6.1.4.1.449.2.1.3.1.1.2.1.1 | Columncdx6500X25StatPortNumber | read-only | mandatory | The port number for this X.25 port. |
| 1.3.6.1.4.1.449.2.1.3.1.1.2.1.2 | Columncdx6500X25StatPortStatus | read-only | mandatory | Status of this port : Up - Port is active Down - Port Is inactive Disabled - An operator has disabled the port Busy Out - an operator has busied out the port |
| 1.3.6.1.4.1.449.2.1.3.1.1.2.1.3 | Columncdx6500X25StatPortState | read-only | mandatory | discPhase - Disconnect Phase. linkDisk - Link Disconnect. linkSetup - The port is sending SABM frames and waiting for a UA response. sabmColl - SABM Collision.… |
| 1.3.6.1.4.1.449.2.1.3.1.1.2.1.4 | Columncdx6500X25StatActualPortSpeed | read-only | mandatory | This is the speed of the port when Clock = INT; this is the detected clock speed if Clock = EXT. If Port Speed is 0, Clock = EXT, but clocking is not being rec… |
| 1.3.6.1.4.1.449.2.1.3.1.1.2.1.5 | Columncdx6500X25StatPortUtilIn | read-only | mandatory | Percentage of port bandwidth in use. |
| 1.3.6.1.4.1.449.2.1.3.1.1.2.1.6 | Columncdx6500X25StatPortUtilOut | read-only | mandatory | Percentage of port bandwidth in use. |
| 1.3.6.1.4.1.449.2.1.3.1.1.2.1.7 | Columncdx6500X25StatMaxSVCCount | read-only | mandatory | Maximum number of SVCs in use since last node, port or statistics reset. |
| 1.3.6.1.4.1.449.2.1.3.1.1.2.1.8 | Columncdx6500X25StatCurrSVCCount | read-only | mandatory | Current number of SVCs in use. |
| 1.3.6.1.4.1.449.2.1.3.1.1.2.1.9 | Columncdx6500X25StatInChars | read-only | mandatory | Number of characters received since last node, port or statistics reset. |
| 1.3.6.1.4.1.449.2.1.3.1.1.2.1.10 | Columncdx6500X25StatOutChars | read-only | mandatory | Number of characters sent since last node, port or statistics reset. |
| 1.3.6.1.4.1.449.2.1.3.1.1.2.1.11 | Columncdx6500X25StatInPkts | read-only | mandatory | Number of packets received since last node, port or statistics reset. |
| 1.3.6.1.4.1.449.2.1.3.1.1.2.1.12 | Columncdx6500X25StatOutPkts | read-only | mandatory | Number of packets sent since last node, port or statistics reset. |
| 1.3.6.1.4.1.449.2.1.3.1.1.2.1.13 | Columncdx6500X25StatInDataFrames | read-only | mandatory | Number of frames received since last node, port or statistics reset. |
| 1.3.6.1.4.1.449.2.1.3.1.1.2.1.14 | Columncdx6500X25StatOutDataFrames | read-only | mandatory | Number of frames sent since last node, port or statistics reset. |
| 1.3.6.1.4.1.449.2.1.3.1.1.2.1.15 | Columncdx6500X25StatNumPktsQueued | read-only | mandatory | Number of packets currently queued. |
| 1.3.6.1.4.1.449.2.1.3.1.1.2.1.16 | Columncdx6500X25StatCharRateIn | read-only | mandatory | Summary of the characters being received by the port. |
| 1.3.6.1.4.1.449.2.1.3.1.1.2.1.17 | Columncdx6500X25StatCharRateOut | read-only | mandatory | Summary of the characters being sent by the port. |
| 1.3.6.1.4.1.449.2.1.3.1.1.2.1.18 | Columncdx6500X25StatPktRateIn | read-only | mandatory | Summary of the packets being received by the port. |
| 1.3.6.1.4.1.449.2.1.3.1.1.2.1.19 | Columncdx6500X25StatPktRateOut | read-only | mandatory | Summary of the packets being sent by the port. |
| 1.3.6.1.4.1.449.2.1.3.1.1.2.1.20 | Columncdx6500X25StatFrameRateIn | read-only | mandatory | Summary of the frames being received by the port. |
| 1.3.6.1.4.1.449.2.1.3.1.1.2.1.21 | Columncdx6500X25StatFrameRateOut | read-only | mandatory | Summary of the frames being sent by the port. |
| 1.3.6.1.4.1.449.2.1.3.1.1.2.1.22 | Columncdx6500X25StatOverrunErrs | read-only | mandatory | Number of Overrun errors since the last node or statistics reset. |
| 1.3.6.1.4.1.449.2.1.3.1.1.2.1.23 | Columncdx6500X25StatUnderrunErrs | read-only | mandatory | Number of Underrun errors since the last node or statistics reset. |
| 1.3.6.1.4.1.449.2.1.3.1.1.2.1.24 | Columncdx6500X25StatCRCErrs | read-only | mandatory | Number of CRC errors since the last node or statistics reset. |
| 1.3.6.1.4.1.449.2.1.3.1.1.2.1.25 | Columncdx6500X25StatInInfoFrames | read-only | mandatory | Number of Info frames received since last node, port or statistics reset. |
| 1.3.6.1.4.1.449.2.1.3.1.1.2.1.26 | Columncdx6500X25StatOutInfoFrames | read-only | mandatory | Number of Info frames sent since last node, port or statistics reset. |
| 1.3.6.1.4.1.449.2.1.3.1.1.2.1.27 | Columncdx6500X25StatInRNRFrames | read-only | mandatory | Number of frames received since last node, port or statistics reset indicating RNR. |
| 1.3.6.1.4.1.449.2.1.3.1.1.2.1.28 | Columncdx6500X25StatOutRNRFrames | read-only | mandatory | Number of frames sent since last node, port or statistics reset indicating RNR. |
| 1.3.6.1.4.1.449.2.1.3.1.1.2.1.29 | Columncdx6500X25StatInRRFrames | read-only | mandatory | Number of frames received since last node, port or statistics reset indicating RR. |
| 1.3.6.1.4.1.449.2.1.3.1.1.2.1.30 | Columncdx6500X25StatOutRRFrames | read-only | mandatory | Number of frames sent since last node, port or statistics reset indicating RR. |
| 1.3.6.1.4.1.449.2.1.3.1.1.2.1.31 | Columncdx6500X25StatInREJFrames | read-only | mandatory | Number of frames received since last node, port or statistics reset indicating REJ. |
| 1.3.6.1.4.1.449.2.1.3.1.1.2.1.32 | Columncdx6500X25StatOutREJFrames | read-only | mandatory | Number of frames sent since last node, port or statistics reset indicating REJ. |
| 1.3.6.1.4.1.449.2.1.3.1.1.2.1.33 | Columncdx6500X25StatInDataPkts | read-only | mandatory | Number of data packets received since last node, port or statistics reset. |
| 1.3.6.1.4.1.449.2.1.3.1.1.2.1.34 | Columncdx6500X25StatOutDataPkts | read-only | mandatory | Number of data packets sent since last node, port or statistics reset. |
| 1.3.6.1.4.1.449.2.1.3.1.1.2.1.35 | Columncdx6500X25StatNumRxCallsSinceLastReset | read-only | mandatory | The number of inbound calls that were attempted since the last statistics reset. |
| 1.3.6.1.4.1.449.2.1.3.1.1.2.1.36 | Columncdx6500X25StatNumRxCallsRejected | read-only | mandatory | The number of inbound calls that were rejected since the last statistics reset. |
| 1.3.6.1.4.1.449.2.1.3.1.1.2.1.37 | Columncdx6500X25StatRxLastCallFailureCause | read-only | mandatory | The reason the last inbound call was rejected, since the last statistics reset. The posssible values are: notAvailable : Value not available if not a (virtual)… |
| 1.3.6.1.4.1.449.2.1.3.1.1.2.1.38 | Columncdx6500X25StatRxLastCalledNumber | read-only | mandatory | The phone number of the virtual port of the last ISDN call made into this port. |
| 1.3.6.1.4.1.449.2.1.3.1.1.2.1.39 | Columncdx6500X25StatRxLastCallingNumber | read-only | mandatory | The phone number of last party to make an ISDN call into this port. |
| 1.3.6.1.4.1.449.2.1.3.1.1.2.1.40 | Columncdx6500X25StatRxMinCallDuration | read-only | mandatory | The minimum call duration of all inbound ISDN calls made into this port, since the last statistics reset. |
| 1.3.6.1.4.1.449.2.1.3.1.1.2.1.41 | Columncdx6500X25StatRxMaxCallDuration | read-only | mandatory | The maximum call duration of all inbound ISDN calls made into this port, since the last statistics reset. |
| 1.3.6.1.4.1.449.2.1.3.1.1.2.1.42 | Columncdx6500X25StatRxAvgCallDuration | read-only | mandatory | The average call duration of all inbound ISDN calls made into this port, since the last statistics reset. |
| 1.3.6.1.4.1.449.2.1.3.1.1.2.1.43 | Columncdx6500X25StatNumTxCallsSinceLastReset | read-only | mandatory | The number of outbound calls that were attempted since the last statistics reset. |
| 1.3.6.1.4.1.449.2.1.3.1.1.2.1.44 | Columncdx6500X25StatNumTxCallsRejected | read-only | mandatory | The number of outbound calls that were rejected since the last statistics reset. |
| 1.3.6.1.4.1.449.2.1.3.1.1.2.1.45 | Columncdx6500X25StatTxLastCallFailureCause | read-only | mandatory | The reason the last inbound call was rejected, since the last statistics reset. The posssible values are: notAvailable : Value not available if not a (virtual)… |
| 1.3.6.1.4.1.449.2.1.3.1.1.2.1.46 | Columncdx6500X25StatTxLastCalledNumber | read-only | mandatory | The phone number of the last ISDN call made by a virtual port from this port. |
| 1.3.6.1.4.1.449.2.1.3.1.1.2.1.47 | Columncdx6500X25StatTxLastCallingNumber | read-only | mandatory | The phone number of the virtual port that made the last ISDN call from this port. |
| 1.3.6.1.4.1.449.2.1.3.1.1.2.1.48 | Columncdx6500X25StatTxMinCallDuration | read-only | mandatory | The minimum call duration of all outbound ISDN calls made from this port, since the last statistics reset. |
| 1.3.6.1.4.1.449.2.1.3.1.1.2.1.49 | Columncdx6500X25StatTxMaxCallDuration | read-only | mandatory | The maximum call duration of all outbound ISDN calls made from this port, since the last statistics reset. |
| 1.3.6.1.4.1.449.2.1.3.1.1.2.1.50 | Columncdx6500X25StatTxAvgCallDuration | read-only | mandatory | The average call duration of all outbound ISDN calls made from this port, since the last statistics reset. |
| 1.3.6.1.4.1.449.2.1.3.1.1.2.1.51 | Columncdx6500X25StatSignalingState | read-only | mandatory | ISDN call signaling state. The possible values are: idle : No ISDN call present. ringing : Pending outgoing ISDN call request. connected : ISDN call is connect… |
| 1.3.6.1.4.1.449.2.1.3.1.1.2.1.52 | Columncdx6500X25StatMaxPortUtilIn | read-only | mandatory | Max percentage of port bandwidth in use since last node, port or statistics reset. |
| 1.3.6.1.4.1.449.2.1.3.1.1.2.1.53 | Columncdx6500X25StatMaxPortUtilOut | read-only | mandatory | Max percentage of port bandwidth in use since last node, port or statistics reset. |
| 1.3.6.1.4.1.449.2.1.3.1.1.2.1.54 | Columncdx6500X25StatMaxPortUtilInTime | read-only | mandatory | Time stamp of Max percentage of port bandwidth in use since last node, port or statistics reset. |
| 1.3.6.1.4.1.449.2.1.3.1.1.2.1.55 | Columncdx6500X25StatMaxPortUtilOutTime | read-only | mandatory | Time stamp of Max percentage of port bandwidth in use since last node, port or statistics reset. |
| 1.3.6.1.4.1.449.2.1.3.1.1.2.1.56 | Columncdx6500X25StatMaxSVCCountTime | read-only | mandatory | Time stamp of Maximum number of SVCs in use since last node, port or statistics reset. |
| 1.3.6.1.4.1.449.2.1.4 | Nodecdx6500Controls |
Type Definitions
| Name | Syntax | Status | Description |
|---|---|---|---|
| Counter16 | INTEGER (0..65535) | ||
| DisplayString | OCTET STRING |