MIB Viewer

cdmaFaultStatus

OBJECT-TYPE
1.3.6.1.4.1.13827.1.1.1
Access
read-only
Status
current
Sub-identifiers
0
This is a bit string contained in one character representing the least significant two nibbles of the CDMA fault status word. Unfortunately, SNMP numbers the bits in the reverse order, so that the enumerated values are backwards from the description contained in the User's Manual for the fault status field returned by the cdmastat command. Each bit indicates a fault when set. Currently defined fault states encoded in this value: Bit 7: DAC controlling the TCXO is near the high or low limit. Bit 6: Time Figure of Merit has been 9 (unsynchronized) for 1 hour. Bit 5: Field Programmable Gate Array (FPGA) did not configure properly. Bit 4: FLASH memory had a write fault. Bit 3: Local Oscillator PLL fault. Bit 2: Local Oscillator PLL failed. Bit 1: NTP daemon is not polling the CDMA reference clock. Bit 0: Not Used.
BITS { cdmaNotUsed (0), cdmaNTPNotPolling (1), cdmaLOFailure (2), cdmaLOPLLFlt (3), cdmaFLASHWriteFlt (4), cdmaFPGACfgFlt (5), cdmaNoSignalTimeout (6), cdmaDACNearLimit (7) }