MIB Viewer

cfgWlanHoDistanceMeasurementPeriod

OBJECT-TYPE
1.3.6.1.4.1.16177.1.400.1.1.3.3.1.22
Access
read-write
Status
current
Sub-identifiers
0
Distance ranging measurement period in milliseconds. Setting zero disables distance handoff. This value is only active when `cfgWlanHoProfile` is set to T2Gv3. Typical ranging measurement period values are in the range from 200 ms to 1000 ms. Values lower than 100 ms are not recommended. Applies to STA. 802.11n products only.
Integer32 (0..100000)