MIB Viewer

chasSlotModuleOperStatus

OBJECT-TYPE
1.3.6.1.4.1.36.2.18.11.1.1.1.1.6.1.8
Access
read-only
Status
mandatory
Sub-identifiers
0
Indicates the operational state of the module. up(1) indicates that the module is performing as expected. disabled(2) indicates that the module has been disabled. insufficient-power(3) indicates that the chassis lacks the power needed by the module. fatal-error(4) indicates that the module encountered an error which prevents its operation. non-fatal-error(5) indicates that the module encountered an error which may inhibit its operation, but does not prevent its operating in a diminished capacity.
INTEGER { up(1), disabled(2), insufficient-power(3), fatal-error(4), non-fatal-error(5) }