MIB Viewer

controlSwAdminStatus

OBJECT-TYPE
1.3.6.1.4.1.285.5.13
Access
read-write
Status
optional
Sub-identifiers
0
This object controls the state of the SW images in systems where more than one image is present. In the OC-9100 the state of each image may be: empty(1) - no image is present, future1(2) - the image may be used later, futureTest(3) - the image will be used once on the next restart, future2(4) - the image may be used later, current1(5) - the image is in use now, past(6) - the image was previously used, current2(7) - the image is in use now, checksumError(8) - the image is faulty, erased(9) - the image has been erased. Because this information is stored in flash each state cannot be used arbitrarily. For example, the future state can only be used twice, namely as state future1 and future2. Normally, the state of a SW image progresses through numerically increasing states. In the OC-8500 and OC-8700 series the status word is stored in BBS RAM. This releases the constraints to the sequence of states, thus only a subset of the above is needed: empty(1) - no image is present, future1(2) - the image may be used later, futureTest(3) - the image will be used once on the next restart, current1(5) - the image is in use now, past(6) - the image was previously used, checksumError(8) - the image is faulty, erased(9) - the image has been erased. The value actually stored in this object is state1*256+state2, where state1 and state2 are the values of the two SW image states. Note that a number of combinations are illegal. For example, the value 6*256+6 (indicating two 'past' images) may not be written.
INTEGER