MIB Viewer

csuAISLoopdown

OBJECT-TYPE
1.3.6.1.4.1.498.2.1.1.9
Access
read-write
Status
mandatory
Sub-identifiers
0
This variable is used to set the AIS Loop-Down option for remotely-initiated DS1 loopbacks. 4, inhibit, refers to when a continuous received AIS does not terminate the loopback. 5-60, enable, refers to when a continuous received AIS terminates the loopback. The value is used to determine the loop-down activation time in seconds. GDCPRODUCT EQUIVALENT POSSIBLESELECTIONS 552a-1 AIS Loopdown inhibit, Enable-30seconds, Enable-<n> seconds 552a AIS Loopdown inhibit, Enable-30seconds, Enable-<n> seconds 552a V1.1 AIS Loopdown inhibit, Enable-30seconds, Enable-<n> seconds 551 None
INTEGER (4..60)