MIB Viewer

ctTimeSlots

OBJECT-TYPE
1.3.6.1.4.1.226.3.2.1.1.1.1.1.2
Access
read-write
Status
current
Sub-identifiers
0
This object controls number of discrete sample intervals over which data shall be accessible in the CODIMA Express History Database Tables. When the ctSampleType = longTerm the value controls how many hours worth of statistics are accessible. When the ctSampleType = shortTerm the value controls how many minutes worth of statistics are accessible. Long Term databases use sample intervals of 15 minutes. Short Term databases use sample intervals of 15 seconds. For Long Term databases, setting this object to a value of 2 will allow 2 hours, i.e. 8 * 15 minutes, of data gathered by all the Long Term History Databases, to be collected via SNMP polling. Setting this object to the maximum value if 32 will give 32 hours worth of discrete 15 minute samples. For Short Term databases, setting this object to a value of 2 will allow 2 minutes, i.e. 8 * 15 seconds, of data gathered by all the Short Term History Databases, to be collected via SNMP polling. Setting this object to the maximum value if 32 will give 32 minutes worth of discrete 15 second samples.
INTEGER (1..32)