MIB Viewer

dlgDsx1TransmitClockSource

OBJECT-TYPE
1.3.6.1.4.1.3028.3.1.1.6.1.12
Access
read-write
Status
mandatory
Sub-identifiers
0
The source of Transmit Clock. This is not the Clock source which you can set form the Dialogic Configuration Manager 1 - 'loopTiming' as the transmit clock, the recovered clock is from the network. 2 - 'localTiming' used, 1.544MhzforT1 or 2.048Mhz for E1. 3 - 'No Timing' interface. The set request with this value will set the clock On this interface to No clock.
INTEGER { loopTiming (1), localTiming (2), noOrExternalTiming (3) }