MIB Viewer

e3LoopbackConfig

OBJECT-TYPE
1.3.6.1.4.1.326.2.2.1.1.5.1.1.1.8
Access
read-write
Status
current
Sub-identifiers
0
This variable represents the loopback configuration of the E3 interface. This variable is defined in the rfc1407 configuration table as dsx3LoopbackConfig, with slightly different values. e3NoLoop (1) means that the interface is not in a loopback state. e3CellLoop (2) means that cells that are processed by the receiving component are not written into the receive FIFO, but into the transmit FIFO for retransmission. e3PayloadLoop (3) means that the receive signal is looped back for retransmission after it has passed through the port's reframing function. e3DiagLoop (4) means that the transmit data stream is looped back to the receiver. e3LineLoop (5) means that the received data stream is reflected back to the sender. e3OtherLoop (6) means that the interface is in a loopback that is not defined here.
INTEGER { e3NoLoop (1), e3CellLoop (2), e3PayloadLoop (3), e3DiagLoop (4), e3LineLoop (5), e3OtherLoop (6) }