MIB Viewer

esiOrSecLinkAssignCfgTerminateCallonDeactivation

OBJECT-TYPE
1.3.6.1.4.1.335.1.2.1.3.5.2.3.1.9
Access
read-write
Status
mandatory
Sub-identifiers
0
This parameter allows the option of leaving a link up if a switched voice call is in place even if the time of day configuration indicates it is time to deactivate the link. Setting this parameter to NO will bring down the link only when all switched voice calls have hung up. The default is NO.
INTEGER { yes (1), no (2) }