MIB Viewer

exNetPortLinkStatus

OBJECT-TYPE
1.3.6.1.4.1.66.1.3.2.3.1.1.3
Access
read-only
Status
mandatory
Source
DAVID-MIB
Sub-identifiers
0
For 10BASE-T ports: this is the link integrity test defined by the 10BASE-T standard. If link status test is enabled, this flag indicates whether the link is active or inactive. There are several reasons for an inactive link: . PC or workstation connected to the MAU has been turned off . disrupted link (e.g., wiring problem) . TP-MAU on the end of the link is missing, dead, or powered off . transmit and receive polarities are swapped For FOIRL ports: the link status is constantly tested; thus, this variable is always meaningful. A value of off(1) indicates a low-light condition (poor signal quality). The value on(2) indicates that signal quality on the link is ok. For AUI ports: the value other(3) is always returned since link status test does not apply.
INTEGER { off(1), on(2), other(3) }