fcfIsdnDSigUnuseTimer

OBJECT-TYPE
1.3.6.1.4.1.866.20.1.10.5.10.1.3
Access
read-write
Status
mandatory
Source
PCE-MIB
Sub-identifiers
0
The value of this object is the unuse timer in seconds for this basic rate interface. This function is specified in order to clear a call when no communications are established on it. This timer starts upon the clearing of the last communication using this call and it is normally stopped when a new one is initiated. The equipment clears the call when this timer runs out. The value '0' disables the processing of this timer. This is a decimal integer in the range 0 to 2550 by step of 10. The default value is '10'.