fcfIsdnDTimT305DisconnectResponseTimer

OBJECT-TYPE
1.3.6.1.4.1.866.20.1.10.5.11.1.12
Access
read-write
Status
mandatory
Source
PCE-MIB
Sub-identifiers
0
The value of this object is the T305 timer in seconds for this basic rate interface. This timer starts when a DISCONNECT call clearing message is sent and it is normally stopped when a RELEASE or DISCONNECT message is received. When this timer runs out the equipment sent a RELEASE message. This is a decimal integer in the range 1 to 255. The default value is '30'.