MIB Viewer

fcfIsdnDTimT308ReleaseResponseTimer

OBJECT-TYPE
1.3.6.1.4.1.866.20.1.10.5.11.1.13
Access
read-write
Status
mandatory
Source
PCE-MIB
Sub-identifiers
0
The value of this object is the T308 timer in seconds for this basic rate interface. This timer starts when a RELEASE call clearing message is sent and it is normally stopped when a RELEASE COMPLETE or RELEASE message is received. When this timer runs out for the first time the equipment retransmits the RELEASE message and restarts this timer. When this timer runs out for the second time the equipment places the B-channel in maintenance condition. This is a decimal integer in the range 1 to 255. The default value is '4'.
INTEGER (1..255)