MIB Viewer

fcfIsdnDTimT310CallProceedingTimer

OBJECT-TYPE
1.3.6.1.4.1.866.20.1.10.5.11.1.15
Access
read-write
Status
mandatory
Source
PCE-MIB
Sub-identifiers
0
The value of this object is the T310 timer in seconds for this basic rate interface. This timer starts when a CALL PROCEEDING call establishment message is received and it is normally stopped when an ALERTING, CONNECT, DISCONNECT or PROGRESS message is received. The DISCONNECT message is sent when this timer runs out. This is a decimal integer in the range 1 to 255. The default value is '40'.
INTEGER (1..255)