MIB Viewer

fcfLineV11DceControl105

OBJECT-TYPE
1.3.6.1.4.1.866.20.1.10.2.16.1.2
Access
read-write
Status
mandatory
Source
PCE-MIB
Sub-identifiers
0
The value of this object defines how the circuit 105 (C, control) is monitored to eventually generate the corresponding event when its state changes and, when it is monitored, how it is scanned to determine whether this serial line interface is up or down. notMonitored : this circuit is not used, monitoredNotSignificant : this circuit is monitored (eventually events are generated) but it is not scanned to determine the state of this serial line interface, monitoredOff : this circuit is monitored (eventually events are generated) and it must be in the OFF condition to determine that this serial line interface is in the UP state, monitoredOn : this circuit is monitored (eventually events are generated) and it must be in the ON condition to determine that this serial line interface is in the UP state. The default value is 'monitoredOn'.
INTEGER { notMonitored(1), monitoredNotSignificant(2), monitoredOff(3), monitoredOn(4) }